HSHenry Shin

Henry Shin

*This is an algorithmically generated author record based on publicly available information.

Henry Shin has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    StimEMG: An Electromyogram Recording System With Real-Time Removal of Time-Varying Electrical Stimulation Artifacts

    by Jiashun Zhao, Rui Yuan, Henry Shin, Run Ji, Yang Zheng

    A closed-loop Functional Electrical Stimulation (FES) system that incorporates electromyogram (EMG) signal feedback provides more effective assistance to paralytic patients in maintaining and recovering their motor abilities. However, the closed-loop FES system with real-time adjustment of stimulation parameters tends to introduce time-varying stimulation artifacts in EMG signals, challenging the removal of stimulation artifacts that aims at more accurate monitoring of muscle contraction status. Therefore, an EMG acquisition system that embeds a stimulation artifact generation (SAG) circuit and the Recursive Least Squares (RLS) adaptive filter was developed in this study and named StimEMG. The SAG-RLS strategy was tested using the simulated contaminated EMG signals and the StimEMG system was tested in an experimental study with 8 subjects. Both the simulation and the experimental study showed that the SAG-RLS method obtained a higher correlation (R2) between the denoised EMG and the corresponding clean EMG or EMG segments compared with the current Gram-Schmidt-based (GSB) method (simulation study, 0.98±0.0044 v.s. 0.65±0.3217; experimental study, 0.99±0.0024 v.s. 0.52±0.2105). Meanwhile, the SAG-RLS method can suppress stimulation artifact more effectively, resulting a higher signal-to-noise ratio (simulation study: 12.83±2.1745 v.s. 1.54±1.3106) and higher noise rejection ratio (experimental study:2.32±0.7046 v.s. 1.92±0.8014). The significantly improved performance is speculated to result from the ability of the SAG unit to precisely and timely capture the variation of the stimulation artifacts caused by the change of stimulation parameters, unlike previous methods relying on the stability of the characteristic of stimulation artifacts in the contaminated EMG signals. The developed StimEMG system provides a robust EMG acquisition module for the closed-loop FES system.


  • Quantifying Muscle Co-Activation for Impaired Finger Independence in Stroke Survivors

    by Yuwen Ruan, Henry Shin, Xiaogang Hu

    Objective: Hand impairment frequently occurs in individuals following a stroke. There is evidence of abnormal muscle co-activation that contributes to impaired control of finger independence. This study quantitatively analyzed hand muscle co-activation patterns of chronic stroke survivors. Systematically quantifying the degree of muscle co-activation patterns in stroke survivors can help us to better understand the mechanisms behind compromised finger independence and enables a more accurate assessment of hand impairment. Methods: We analyzed muscle co-activation patterns both macroscopically and microscopically using high-density surface electromyographic (HD-sEMG) signals and decomposed motor unit signals from extrinsic and intrinsic flexor/extensor muscles. The muscle co-activation patterns between both sides of stroke survivors and neurologically intact controls were compared. Results: We observed increased levels of co-activation in the affected sides of stroke survivors compared with their contralateral sides and the control groups, with a higher degree in the extrinsic muscles than the intrinsic muscles. The asymmetry in muscle co-activation between hands correlated with impaired finger force independence and clinical assessment scales. In the micro-level analysis of motor unit action potentials (MUAPs) distributions, we observed a notable increase in action potential spread of MUAPs in the individual affected extrinsic muscles, but the altered MUAP distribution did not correlate with clinical assessment scales. Conclusion: We systematically quantified abnormal muscle co-activation patterns in impaired finger independence after stroke. Significance: With further development, the outcomes provide a comprehensive understanding of hand dexterity deficits in stroke survivors, which may provide guidance for targeted rehabilitation strategies and offer a potential for automated impairment evaluations.


  • Activation of Superficial and Deep Finger Flexors Through Transcutaneous Nerve Stimulation

    by Henry Shin, Marwan A. Hawari, Xiaogang Hu

    Objective: Functional electrical stimulation (FES) is a common technique to elicit muscle contraction and help improve muscle strength. Traditional FES over the muscle belly typically only activates superficial muscle regions. In the case of hand FES, this prevents the activation of the deeper flexor muscles which control the distal finger joints. Here, we evaluated whether an alternative transcutaneous nerve-bundle stimulation approach can activate both superficial and deep extrinsic finger flexors using a high-density stimulation grid. Methods: Transverse ultrasound of the forearm muscles was used to obtain cross-sectional images of the underlying finger flexors during stimulated finger flexions and kinematically-matched voluntary motions. Finger kinematics were recorded, and an image registration method was used to capture the large deformation of the muscle regions during each flexion. This deformation was used as a surrogate measure of the contraction of muscle tissue, and the regions of expanding tissue can identify activated muscles. Results: The nerve-bundle stimulation elicited contractions in the superficial and deep finger flexors. Both separate and concurrent activation of these two muscles were observed. Joint kinematics of the fingers also matched the expected regions of muscle contractions. Conclusions: Our results showed that the nerve-bundle stimulation technique can activate the deep extrinsic finger flexors, which are typically not accessible via traditional surface FES. Significance: Our nerve-bundle stimulation method enables us to produce the full range of motion of different joints necessary for various functional grasps, which could benefit future neuroprosthetic applications.


  • Object stiffness recognition using haptic feedback delivered through transcutaneous proximal nerve stimulation

    by Luis Vargas, Henry Shin, He (Helen) Huang, Yong Zhu, Xiaogang Hu

    Objective . Haptic feedback is crucial when we manipulate objects. Information pertaining to an object’s stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous electrical stimulation of peripheral nerves. Approach . Using a stimulation electrode grid placed along the medial side of the upper arm, the median and ulnar nerve bundles were targeted to evoke haptic sensation on the palmar side of the hand. Stimulation current amplitude was modulated in real-time with the fingertip force recorded from a sensorized prosthetic hand. In order to evaluate which stimulation pattern was more critical, object stiffness was encoded either by the rate of change of the stimulus amplitude or the level of peak stimulus amplitude, as the prosthesis grasped the objects. Main results . Both encoding methods allowed the subjects to differentiate objects of different stiffness levels with >90% accuracy. No significant difference was observed between the two encoding methods, which indicated that both the rate of change of the stimulation amplitude and the peak stimulation amplitude could effectively provide stiffness information of the objects. Significance . The outcomes suggest that it is possible to elicit haptic sensations describing various object stiffness levels using transcutaneous nerve stimulation. The haptic feedback associated with object stiffness can facilitate object manipulation/interactions. It may also improve user experience during human–machine interactions, when object stiffness information is incorporated.


  • Delayed fatigue in finger flexion forces through transcutaneous nerve stimulation

    by Henry Shin, Ryan Chen, Xiaogang Hu

    Objective . Weakness of the hand is a major impairment which limits independent living. Neuromuscular electrical stimulation (NMES) is a common approach to help restore muscle strength. Traditional NMES directly over the muscle often leads to a rapid onset of muscle fatigue. In this study, we investigated the force sustainability of finger flexor muscles using a transcutaneous nerve stimulation approach. Approach . Finger flexion forces and high-density electromyogram (HD EMG) signals were obtained while electrical stimulation was applied to the ulnar and median nerve bundles through a stimulation grid on the proximal arm segment. Stimulation was also applied to the finger flexor muscle belly targeting the motor point, serving as a control condition. The force produced from the two stimulation approaches were initially matched, and muscle fatigue was subsequently induced with 5 min of continuous stimulation. The rate of decay of the force and EMG amplitude were quantified, and the spatial distribution of the muscle activation during the sustained contraction was also evaluated. Main results . The proximal nerve stimulation approach induced a slower decay in both force and EMG, compared with the stimulation at the motor point. The spatial distribution of the elicited muscle activation showed that the proximal nerve stimulation led to a distributed activation across the intrinsic and extrinsic finger flexor muscles and also activated a wider area within the extrinsic muscle. Significance . Our findings demonstrated that the stimulation of the proximal nerve bundles can elicit sustained force output and delayed decrease in the rate of force decline. This is potentially due to a spatially distributed activation of the muscle fibers, compared with the traditional motor point stimulation. Future development of our nerve stimulation approach may enable prolonged usage during rehabilitation or assistance for better functional outcomes.


  • Evoked haptic sensations in the hand via non-invasive proximal nerve stimulation

    by Henry Shin, Zach Watkins, He (Helen) Huang, Yong Zhu, Xiaogang Hu

    Objective . Haptic perception of a prosthetic limb or hand is a crucial, but often unmet, need which impacts the utility of the prostheses. In this study, we seek to evaluate the feasibility of a non-invasive transcutaneous nerve stimulation method in generating haptic feedback in a transradial amputee subject as well as intact able-bodied subjects. Approach . An electrode grid was placed on the skin along the medial side of the upper arm beneath the short head of the biceps brachii, in proximity to the median and ulnar nerves. Varying stimulation patterns were delivered to different electrode pairs, in order to emulate different types of sensations (Single Tap, Press-and-Hold, Double Tap) at different regions of the hand. Subjects then reported the magnitude of sensation by pressing on a force transducer to transform the qualitative haptic perception into a quantitative measurement. Main results . Altering current stimulations through electrode pairs on the grid resulted in repeatable alterations in the percept regions of the hand. Most subjects reported spatial coverage of individual fingers or phalanges, which can resemble the whole hand through different pairs of stimulation electrodes. The different stimulation patterns were also differentiable by all subjects. The amputee subject also reported haptic sensations similar to the able-bodied subjects. Significance . Our findings demonstrated the capabilities of our transcutaneous stimulation method. Subjects were able to perceive spatially distinct sensations with graded magnitudes that emulated tapping and holding sensation in their hands. The elicitation of haptic sensations in the phantom hand of an amputee is a significant step in the development of our stimulation method, and provides insight into the future adaptation and implementation of prostheses with non-invasive sensory feedback to the users.


  • Relative contribution of different altered motor unit control to muscle weakness in stroke: a simulation study

    by Henry Shin, Nina L Suresh, William Zev Rymer, Xiaogang Hu

    Objective . Chronic muscle weakness impacts the majority of individuals after a stroke. The origins of this hemiparesis is multifaceted, and an altered spinal control of the motor unit (MU) pool can lead to muscle weakness. However, the relative contribution of different MU recruitment and discharge organization is not well understood. In this study, we sought to examine these different effects by utilizing a MU simulation with variations set to mimic the changes of MU control in stroke. Approach . Using a well-established model of the MU pool, this study quantified the changes in force output caused by changes in MU recruitment range and recruitment order, as well as MU firing rate organization at the population level. We additionally expanded the original model to include a fatigue component, which variably decreased the output force with increasing length of contraction. Differences in the force output at both the peak and fatigued time points across different excitation levels were quantified and compared across different sets of MU parameters. Main results . Across the different simulation parameters, we found that the main driving factor of the reduced force output was due to the compressed range of MU recruitment. Recruitment compression caused a decrease in total force across all excitation levels. Additionally, a compression of the range of MU firing rates also demonstrated a decrease in the force output mainly at the higher excitation levels. Lastly, changes to the recruitment order of MUs appeared to minimally impact the force output. Significance . We found that altered control of MUs alone, as simulated in this study, can lead to a substantial reduction in muscle force generation in stroke survivors. These findings may provide valuable insight for both clinicians and researchers in prescribing and developing different types of therapies for the rehabilitation and restoration of lost strength after stroke.


  • Open Access

    Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation

    by Henry Shin, Zach Watkins, Xiaogang Hu

    Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (<5 mA and 100 µs pulse width) stimulation, our results show that all of our subjects demonstrated a variety of consistent hand grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.


  • Open Access

    Alterations in Localized Electrical Impedance Myography of Biceps Brachii Muscles Paralyzed by Spinal Cord Injury

    by Le Li, Argyrios Stampas, Henry Shin, Xiaoyan Li, Ping Zhou

    This study assessed electrical impedance myography (EIM) changes after spinal cord injury (SCI) with a localized multi-frequency technology. The EIM measurement was performed on the biceps brachii muscle at rest condition of 22 cervical SCI, and 23 neurologically intact subjects as control group. The results showed that there was a significant decrease in muscle reactance (X) and phase (θ) at selected frequencies (i.e. 50 kHz and 100 kHz) in SCI compared to control. There was no significant difference in muscle resistance (R) between the two groups. The anisotropy examination revealed that SCI group had a decreased anisotropy ratio in resistance. In addition, the multi-frequency spectrum analysis showed a decreased slope of the resistance-logarithm frequency in SCI group when compared to healthy control. Findings of the EIM changes are related to inherit muscle changes after the injury. Since EIM requires no patient effort and is quick and convenient to conduct, it may provide a useful tool for examination of paralyzed muscle changes after SCI.


  • Open Access

    Electrical Impedance Myography for Evaluating Paretic Muscle Changes After Stroke

    by Xiaoyan Li, Le Li, Henry Shin, Sheng Li, Ping Zhou

    Electrical impedance myography (EIM) was used to assess the paretic muscle intrinsic electrical properties post stroke. Twenty-seven subjects with chronic hemiparesis participated in this study. Muscle impedance was measured by applying high-frequency, low-intensity alternating current to biceps brachii muscles. Major EIM parameters, resistance (R), reactance (X), phase angle (8), and electrical anisotropy ratios (AR) of the three parameters, were examined at 50 kHz. Statistical analysis demonstrated significant reduction of reactance, phase angle, AR of resistance, and AR of reactance in the paretic muscle compared with the contralateral side (Paretic X: 6.16 ± 0.55 Q, contralateral X: 7.62 ± 0.46 Ω, and p <; 0.001; Paretic θ: 10.97 ± 0.84°, contralateral θ: 14.5 ± 0.82°, and p <; 0.001; Paretic AR of R: 0.969 ± 0.013, contralateral AR of R: 1.008 ± 0.011, and p <; 0.02; and Paretic AR of X: 0.981 ± 0.066, contralateral AR of X: 1.114 ± 0.041, and p <; 0.02). Correlation analysis, however, did not show any significant-relationship between EIM parameters and clinical assessments. Findings of this paper indicated significant changes in the muscular intrinsic electrical properties after stroke, possibly related to structural modifications induced by loss of muscle fibers or fat infiltration as well as changes in the quality of cell membranes post stroke.