JFJohannes Friedrich

Johannes Friedrich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Johannes Friedrich has a total of 125 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    GIAnT: a Glutamate Imaging Analysis Toolbox

    by Michael E. Xie, Johannes Friedrich, Elizabeth Wirsching, Caleb Jones Shibu, Maedeh Seyedolmohadesin, Naveen Ouellette, Tim Wang, Karel Svoboda, Adam S. Charles, Kaspar Podgorski

    Recent advances in fluorescent indicators and optical microscopy now enable in vivo synaptic imaging of glutamate, which transmits the majority of signals between neurons in the brain. Extracting fluorescence signals from these recordings is complicated by the minuscule scale and dense clustering of synapses on dendrites, as well as brain motion in behaving animals. Here we present the Glutamate Imaging Analysis Toolbox (GIAnT), a set of automated tools for glutamate imaging data that corrects sample motion, identifies active synapses with super-resolution precision, and extracts synaptic fluorescence signals. Compared to methods designed for cellular imaging, GIAnT reduces motion artifacts, more accurately identifies active synapses, and improves extracted signal quality by reducing contamination from overlapping synapses. By pairing in vivo glutamate imaging with post hoc expansion microscopy, we find that >70% of the putative synapses extracted using GIAnT matched one-to-one with glutamatergic synapses onto the postsynaptic cell. Our results establish GIAnT as an automated and validated pipeline for processing synaptic glutamate imaging data at scale.


  • Open Access

    FIOLA: an accelerated pipeline for fluorescence imaging online analysis

    by Changjia Cai, Cynthia Dong, Johannes Friedrich, Marton Rozsa, Eftychios A. Pnevmatikakis, Andrea Giovannucci

    Optical microscopy methods such as calcium and voltage imaging enable fast activity readout of large neuronal populations using light. However, the lack of corresponding advances in online algorithms has slowed progress in retrieving information about neural activity during or shortly after an experiment. This gap not only prevents the execution of real-time closed-loop experiments, but also hampers fast experiment–analysis–theory turnover for high-throughput imaging modalities. Reliable extraction of neural activity from fluorescence imaging frames at speeds compatible with indicator dynamics and imaging modalities poses a challenge. We therefore developed FIOLA, a framework for fluorescence imaging online analysis that extracts neuronal activity from calcium and voltage imaging movies at speeds one order of magnitude faster than state-of-the-art methods. FIOLA exploits algorithms optimized for parallel processing on GPUs and CPUs. We demonstrate reliable and scalable performance of FIOLA on both simulated and real calcium and voltage imaging datasets. Finally, we present an online experimental scenario to provide guidance in setting FIOLA parameters and to highlight the trade-offs of our approach.


  • Open Access

    VolPy: Automated and scalable analysis pipelines for voltage imaging datasets

    by Changjia Cai, Johannes Friedrich, Amrita Singh, M. Hossein Eybposh, Eftychios A. Pnevmatikakis, Kaspar Podgorski, Andrea Giovannucci

    Voltage imaging enables monitoring neural activity at sub-millisecond and sub-cellular scale, unlocking the study of subthreshold activity, synchrony, and network dynamics with unprecedented spatio-temporal resolution. However, high data rates (>800MB/s) and low signal-to-noise ratios create bottlenecks for analyzing such datasets. Here we present VolPy, an automated and scalable pipeline to pre-process voltage imaging datasets. VolPy features motion correction, memory mapping, automated segmentation, denoising and spike extraction, all built on a highly parallelizable, modular, and extensible framework optimized for memory and speed. To aid automated segmentation, we introduce a corpus of 24 manually annotated datasets from different preparations, brain areas and voltage indicators. We benchmark VolPy against ground truth segmentation, simulations and electrophysiology recordings, and we compare its performance with existing algorithms in detecting spikes. Our results indicate that VolPy’s performance in spike extraction and scalability are state-of-the-art.


  • Open Access

    Online analysis of microendoscopic 1-photon calcium imaging data streams

    by Johannes Friedrich, Andrea Giovannucci, Eftychios A. Pnevmatikakis

    In vivo calcium imaging through microendoscopic lenses enables imaging of neuronal populations deep within the brains of freely moving animals. Previously, a constrained matrix factorization approach (CNMF-E) has been suggested to extract single-neuronal activity from microendoscopic data. However, this approach relies on offline batch processing of the entire video data and is demanding both in terms of computing and memory requirements. These drawbacks prevent its applicability to the analysis of large datasets and closed-loop experimental settings. Here we address both issues by introducing two different online algorithms for extracting neuronal activity from streaming microendoscopic data. Our first algorithm, OnACID-E, presents an online adaptation of the CNMF-E algorithm, which dramatically reduces its memory and computation requirements. Our second algorithm proposes a convolution-based background model for microendoscopic data that enables even faster (real time) processing. Our approach is modular and can be combined with existing online motion artifact correction and activity deconvolution methods to provide a highly scalable pipeline for microendoscopic data analysis. We apply our algorithms on four previously published typical experimental datasets and show that they yield similar high-quality results as the popular offline approach, but outperform it with regard to computing time and memory requirements. They can be used instead of CNMF-E to process pre-recorded data with boosted speeds and dramatically reduced memory requirements. Further, they newly enable online analysis of live-streaming data even on a laptop.


  • Open Access

    Online analysis of microendoscopic 1-photon calcium imaging data streams

    by Johannes Friedrich, Andrea Giovannucci, Eftychios A. Pnevmatikakis

    In-vivo calcium imaging through microendoscopic lenses enables imaging of neuronal populations deep within the brains of freely moving animals. Previously, a constrained matrix factorization approach (CNMF-E) has been suggested to extract single-neuronal activity from microendoscopic data. However, this approach relies on offline batch processing of the entire video data and is demanding both in terms of computing and memory requirements. These drawbacks prevent its applicability to the analysis of large datasets and closed-loop experimental settings. Here we address both issues by introducing two different online algorithms for extracting neuronal activity from streaming microendoscopic data. Our first algorithm presents an online adaptation of the CNMF-E algorithm, which dramatically reduces its memory and computation requirements. Our second algorithm proposes a convolution-based background model for microendoscopic data that enables even faster (real time) processing on GPU hardware. Our approach is modular and can be combined with existing online motion artifact correction and activity deconvolution methods to provide a highly scalable pipeline for microendoscopic data analysis. We apply our algorithms on two previously published typical experimental datasets and show that they yield similar high-quality results as the popular offline approach, but outperform it with regard to computing time and memory requirements. Author summary: Calcium imaging methods enable researchers to measure the activity of genetically-targeted large-scale neuronal subpopulations. Whereas previous methods required the specimen to be stable, e.g. anesthetized or head-fixed, new brain imaging techniques using microendoscopic lenses and miniaturized microscopes have enabled deep brain imaging in freely moving mice. However, the very large background fluctuations, the inevitable movements and distortions of imaging field, and the extensive spatial overlaps of fluorescent signals complicate the goal of efficiently extracting accurate estimates of neural activity from the observed video data. Further, current activity extraction methods are computationally expensive due to the complex background model and are typically applied to imaging data after the experiment is complete. Moreover, in some scenarios it is necessary to perform experiments in real-time and closed-loop – analyzing data on-the-fly to guide the next experimental steps or to control feedback –, and this calls for new methods for accurate real-time processing. Here we address both issues by adapting a popular extraction method to operate online and extend it to utilize GPU hardware that enables real time processing. Our algorithms yield similar high-quality results as the original offline approach, but outperform it with regard to computing time and memory requirements. Our results enable faster and scalable analysis, and open the door to new closed-loop experiments in deep brain areas and on freely-moving preparations.


  • Open Access

    VolPy: automated and scalable analysis pipelines for voltage imaging datasets

    by Changjia Cai, Johannes Friedrich, Eftychios A Pnevmatikakis, Kaspar Podgorski, Andrea Giovannucci

    Voltage imaging enables monitoring neural activity at sub-millisecond and sub-compartment scale, and therefore opens the path to studying sub-threshold activity, synchrony, and network dynamics with unprecedented spatio-temporal resolution. However, high data rates (>800MB/s) and low signal-to-noise ratios have created a severe bottleneck for analysis of such datasets. Here we presentVolPy, the first turn-key, automated and scalable pipeline to pre-process voltage imaging datasets.VolPyfeatures fast motion correction, memory mapping, segmentation, and spike inference, all built on a highly parallelized and computationally efficient framework that optimizes memory and speed. Given the lack of single cell voltage imaging ground truth examples, we introduce a corpus of 24 manually annotated datasets from different preparations and voltage indicators. We benchmarkVolPyagainst this corpus and electrophysiology recordings, demonstrating excellent performance in neuron localization, spike extraction, and scalability.


  • Top Cited Papers

    Bright and photostable chemigenetic indicators for extended in vivo voltage imaging

    by Ahmed S. Abdelfattah, Takashi Kawashima, Amrita Singh, Ondrej Novak, Hui Liu, Yichun Shuai, Yi-Chieh Huang, Luke Campagnola, Stephanie C. Seeman, Jianing Yu, et al.

    Visualizing neuronal activity in vivo: Imaging the changes in fluorescence of voltage-sensitive reagents would enable monitoring of the activity of neurons in vivo. Abdelfattah et al. created such a voltage indicator by designing a protein that combines the voltage sensor domain from microbial rhodopsin with a domain that captures a dye molecule with exceptional brightness and photostability. When the protein was expressed in mice, flies, or zebrafish, they could monitor single action potentials in dozens of neurons simultaneously for many minutes. Science , this issue p. 699


  • Top Cited Papers
    Open Access

    CaImAn an open source tool for scalable calcium imaging data analysis

    by Andrea Giovannucci, Johannes Friedrich, Pat Gunn, Jérémie Kalfon, Brandon L Brown, Sue Ann Koay, Jiannis Taxidis, Farzaneh Najafi, Jeffrey L Gauthier, Pengcheng Zhou, et al.

    Advances in fluorescence microscopy enable monitoring larger brain areas in-vivo with finer time resolution. The resulting data rates require reproducible analysis pipelines that are reliable, fully automated, and scalable to datasets generated over the course of months. We present CaImAn, an open-source library for calcium imaging data analysis. CaImAn provides automatic and scalable methods to address problems common to pre-processing, including motion correction, neural activity identification, and registration across different sessions of data collection. It does this while requiring minimal user intervention, with good scalability on computers ranging from laptops to high-performance computing clusters. CaImAn is suitable for two-photon and one-photon imaging, and also enables real-time analysis on streaming data. To benchmark the performance of CaImAn we collected and combined a corpus of manual annotations from multiple labelers on nine mouse two-photon datasets. We demonstrate that CaImAn achieves near-human performance in detecting locations of active neurons.


  • Open Access

    CalmAn: An open source tool for scalable Calcium Imaging data Analysis

    by Andrea Giovannucci, Johannes Friedrich, Pat Gunn, Jérémie Kalfon, Sue Ann Koay, Jiannis Taxidis, Farzaneh Najafi, Jeffrey L. Gauthier, Pengcheng Zhou, David W. Tank, et al.

    Advances in fluorescence microscopy enable monitoring larger brain areas in-vivo with finer time resolution. The resulting data rates require reproducible analysis pipelines that are reliable, fully automated, and scalable to datasets generated over the course of months. Here we present CaImAn, an open-source library for calcium imaging data analysis. CaImAn provides automatic and scalable methods to address problems common to pre-processing, including motion correction, neural activity identification, and registration across different sessions of data collection. It does this while requiring minimal user intervention, with good performance on computers ranging from laptops to high-performance computing clusters. CaImAn is suitable for two-photon and one-photon imaging, and also enables real-time analysis on streaming data. To benchmark the performance of CaImAn we collected a corpus of ground truth annotations from multiple labelers on nine mouse two-photon datasets. We demonstrate that CaImAn achieves near-human performance in detecting locations of active neurons.


  • Open Access

    Community-based benchmarking improves spike rate inference from two-photon calcium imaging data

    by Philipp Berens, Jeremy Freeman, Thomas Deneux, Nikolay Chenkov, Thomas McColgan, Artur Speiser, Jakob H Macke, Srinivas C Turaga, Patrick Mineault, Peter Rupprecht, et al.

    In recent years, two-photon calcium imaging has become a standard tool to probe the function of neural circuits and to study computations in neuronal populations. However, the acquired signal is only an indirect measurement of neural activity due to the comparatively slow dynamics of fluorescent calcium indicators. Different algorithms for estimating spike rates from noisy calcium measurements have been proposed in the past, but it is an open question how far performance can be improved. Here, we report the results of the spikefinder challenge, launched to catalyze the development of new spike rate inference algorithms through crowd-sourcing. We present ten of the submitted algorithms which show improved performance compared to previously evaluated methods. Interestingly, the top-performing algorithms are based on a wide range of principles from deep neural networks to generative models, yet provide highly correlated estimates of the neural activity. The competition shows that benchmark challenges can drive algorithmic developments in neuroscience. Two-photon calcium imaging is one of the major tools to study the activity of large populations of neurons in the brain. In this technique, a fluorescent calcium indicator changes its brightness when a neuron fires an action potential due to an associated increase in intracellular calcium. However, while a number of algorithms have been proposed for estimating spike rates from the measured signal, the problem is far from solved. We organized a public competition using a data set for which ground truth data was available. Participants were given a training set to develop new algorithms, and the performance of the algorithms was evaluated on a hidden test set. Here we report on the results of this competition and discuss the progress made towards better algorithms to infer spiking activity from imaging data.