Ramesh Sanga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ramesh Sanga has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
G Prabhakara Rao
EIG, Indira Gandhi Centre for Atomic Research, Kalpakkam, TAMILNADU, INDIA
2 shared publicationsM Sivaramakrishna
EIG, Indira Gandhi Centre for Atomic Research, Kalpakkam, TAMILNADU, INDIA
2 shared publicationsG. Prabhakara Rao
Innovative Sensors Section, Security and Innovative Sensors Division, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam, Tamil Nadu 603102, India
1 shared publication- G. Prabhakara Rao
Security and Innovative sensors division, Electronics and Instrumentation Group
1 shared publication M. Sivaramakrishna
Innovative Sensors Section, Security and Innovative Sensors Division, Indira Gandhi Centre for Atomic Research, HBNI, Kalpakkam, Tamil Nadu 603102, India
1 shared publication- M. Sivaramakrishna
Security and Innovative sensors division, Electronics and Instrumentation Group
1 shared publication
Latest Publications
- 6 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (11) , 115106
Design and development of a quasi-digital sensor and instrument for water turbidity measurement
In this paper, the design, realization, fabrication and assembly of a prototype water turbidity monitoring instrument based on an opto-resistive quasi-digital sensor has been proposed. The turbidity sensor has been constructed with LED (590 nm) as the light source, a light-dependent resistor, fixed capacitor and logic gate inverter. The primary output signal from the sensor is in the form of a transistor–transistor-logic pulse stream with 50% duty cycle. This form of the output signal can be directly interfaced with the microcontroller. To process pulse stream from the sensor, to convert into turbidity value in NTU and to display on an LCD, a microcontroller (PIC18f4550)-based embedded system has been developed. The turbidity monitoring instrument has been constructed, calibrated and experimentally tested by measuring the turbidity of the water in the range of 0–1000 NTU. The turbidity of 0–1000 NTU corresponded to the output frequency of 40.6–18.8 kHz with sensitivity of 22 Hz/NTU. This is a high-precision, low-power, portable instrument with low manufacturing costs compared to commercial turbidity monitoring instruments.
- 6 September 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 30 (11) , 115106
Design and development of a quasi-digital sensor and instrument for water turbidity measurement
In this paper, the design, realization, fabrication and assembly of a prototype water turbidity monitoring instrument based on an opto-resistive quasi-digital sensor has been proposed. The turbidity sensor has been constructed with LED (590 nm) as the light source, a light-dependent resistor, fixed capacitor and logic gate inverter. The primary output signal from the sensor is in the form of a transistor–transistor-logic pulse stream with 50% duty cycle. This form of the output signal can be directly interfaced with the microcontroller. To process pulse stream from the sensor, to convert into turbidity value in NTU and to display on an LCD, a microcontroller (PIC18f4550)-based embedded system has been developed. The turbidity monitoring instrument has been constructed, calibrated and experimentally tested by measuring the turbidity of the water in the range of 0–1000 NTU. The turbidity of 0–1000 NTU corresponded to the output frequency of 40.6–18.8 kHz with sensitivity of 22 Hz/NTU. This is a high-precision, low-power, portable instrument with low manufacturing costs compared to commercial turbidity monitoring instruments.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (17) , 7499-7506
Design and Development of Opto-Resistive Type Quasi-Digital Sensor and Instrument for Online Assessment of the Quality of Lubricant Oil
In rotating machinery, the color of lubricant oil changes due to oxidation, degradation and contamination. It is a crucial parameter to cognize the healthiness of lubricant oil. This paper presents the design and development of a low cost, high precision quasi-digital sensor with an opto-resistive technique to detect the color of lubricant oil with a microcontroller( PIC18F4550) based instrument. The developed instrument reads the sensor output, displays the condition of lubricant oil on LCD, announces the alarm to alert the operator and communicates the healthiness of lubricant oil to the computer. As per the ASTM D1500 standard, the color scale of lubricant oil varies from 0.5 to 8.0. In the studies conducted at the laboratory, this color scale corresponds to the sensor output frequency in the range of 76.87 kHz-61.63 kHz.The sensitivity of the color sensor is 1905Hz/Color code. Apart from this, an additional sensor is provided to measure the turbidity of the lubricant oil, which helps in compensating the error in color scale due to turbidity. In addition to revealing of lube oil color, it can also detect the size of the particles in the lubricant oil. To perform these tasks an algorithm and application software have been developed and loaded into the flash memory of the microcontroller.
- 7 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (17) , 7499-7506
Design and Development of Opto-Resistive Type Quasi-Digital Sensor and Instrument for Online Assessment of the Quality of Lubricant Oil
In rotating machinery, the color of lubricant oil changes due to oxidation, degradation and contamination. It is a crucial parameter to cognize the healthiness of lubricant oil. This paper presents the design and development of a low cost, high precision quasi-digital sensor with an opto-resistive technique to detect the color of lubricant oil with a microcontroller( PIC18F4550) based instrument. The developed instrument reads the sensor output, displays the condition of lubricant oil on LCD, announces the alarm to alert the operator and communicates the healthiness of lubricant oil to the computer. As per the ASTM D1500 standard, the color scale of lubricant oil varies from 0.5 to 8.0. In the studies conducted at the laboratory, this color scale corresponds to the sensor output frequency in the range of 76.87 kHz-61.63 kHz.The sensitivity of the color sensor is 1905Hz/Color code. Apart from this, an additional sensor is provided to measure the turbidity of the lubricant oil, which helps in compensating the error in color scale due to turbidity. In addition to revealing of lube oil color, it can also detect the size of the particles in the lubricant oil. To perform these tasks an algorithm and application software have been developed and loaded into the flash memory of the microcontroller.
- 24 May 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075102
Deployment of an inductance-based quasi-digital sensor to detect metallic wear debris in lubricant oil of rotating machinery
In rotating machinery due to continuous rotational induced wear and tear, metallic debris will be produced and mixes with the in-service lubricant oil over the course of time. This debris gives the sign of potential machine failure due to the aging of critical parts like gears and bearings. The size and type of wear debris has a direct relationship with the degree of wear in the machine and gives information about the healthiness of equipment. This article presents an inductive quasi-digital sensor to detect the metallic debris, its type; size in the lubrication oil of rotating machinery. A microcontroller based low cost, low power, high resolution and high precise instrument with alarm indication and LCD is developed to detect ferrous debris of sizes from 30 µ m and non-ferrous debris of 50 µ m. It is thoroughly tested and calibrated with ferrous, non-ferrous debris of different sizes in the air environment. Finally, an experiment is conducted to check the performance of the instrument by circulating lubricant oil containing ferrous, non-ferrous debris through the sensor.
- 24 May 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (7) , 075102
Deployment of an inductance-based quasi-digital sensor to detect metallic wear debris in lubricant oil of rotating machinery
In rotating machinery due to continuous rotational induced wear and tear, metallic debris will be produced and mixes with the in-service lubricant oil over the course of time. This debris gives the sign of potential machine failure due to the aging of critical parts like gears and bearings. The size and type of wear debris has a direct relationship with the degree of wear in the machine and gives information about the healthiness of equipment. This article presents an inductive quasi-digital sensor to detect the metallic debris, its type; size in the lubrication oil of rotating machinery. A microcontroller based low cost, low power, high resolution and high precise instrument with alarm indication and LCD is developed to detect ferrous debris of sizes from 30 µ m and non-ferrous debris of 50 µ m. It is thoroughly tested and calibrated with ferrous, non-ferrous debris of different sizes in the air environment. Finally, an experiment is conducted to check the performance of the instrument by circulating lubricant oil containing ferrous, non-ferrous debris through the sensor.
- 1 April 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (4) , 045007
Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.
- 1 April 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (4) , 045007
Deployment of quasi-digital sensor for high temperature molten salt level measurement in pyroprocessing plants
Development of a liquid molten salt level sensor device that can detect the level of liquid molten salt in the process vessels of pyrochemical reprocessing of spent metallic fuels is detailed. It is proposed to apply a resistive-type pulsating sensor-based level measurement approach. There are no commercially available sensors due to limitations of high temperature, radiation, and physical dimensions. A compact, simple, rugged, low power, and high precise pulsating sensor-based level probe and simple instrumentation for the molten salt liquid level sensor to work in the extreme conditions has been indigenously developed, with high precision and accuracy. The working principle, design concept, and results have been discussed. This level probe is mainly composed of the variable resistor made up of ceramic rods. This resistor constitutes the part of resistance-capacitance-type Logic Gate Oscillator (LGO). A change in the molten salt level inside the tank causes a small change in the resistance which in turn changes the pulse frequency of the LGO. Thus the frequency, the output of the instrument that is displayed on the LCD of an embedded system, is a function of molten salt level. In the present design, the range of level measurement is about 10 mm. The sensitivity in position measurement up to 10 mm is ∼2.5 kHz/mm.