Javad Ansari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Javad Ansari has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Ahad Kazemi
6 shared publicationsMehdi Ghazavi Dozein
Univ Tehran, Dept Elect & Comp Engn, Coll Engn, Tehran, Iran
6 shared publications- Amin Gholami
School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
3 shared publications Mohsen Kalantar
Centre of Excellence for Power System Automation and Operation, Iran University of Science & Technology, Tehran, Iran
3 shared publicationsMahdi Jamei
College of Engineering and Computing, Electrical and Computer Engineering Department; Florida International University; Miami FL U.S.A.
2 shared publicationsAmin Gholami
Department of Electrical Engineering Iran University of Science and Technology Tehran Iran
1 shared publication
Latest Publications
- 16 July 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (11) , e12096
A joint energy and reserve scheduling framework based on network reliability using smart grids applications
This paper presents a new method based on a probabilistic scheduling reserve for smart grids, which include renewable energy sources (RESs), thermal units, and energy storage systems (ESSs). The method is divided into two main parts. The first part is based on spinning reserve to overcome the load-generation imbalance in the network, while the second part is related to the spinning reserve for the outage of generation units. The total expected energy not supplied (TEENS) is the reliability criterion that determines the required spinning reserve. In the proposed formulation, generation units, the demand response (DR) program, and ESSs are capable of providing both types of reserves. The proposed method is evaluated using The Institute of Electrical and Electronics Engineers (IEEE) standard 30-bus and IEEE reliability test networks. The suggested structure has been implemented by General Algebraic Modeling System (GAMS), and the results indicate the appropriate performance of the proposed method.
- 16 July 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (11) , e12096
A joint energy and reserve scheduling framework based on network reliability using smart grids applications
This paper presents a new method based on a probabilistic scheduling reserve for smart grids, which include renewable energy sources (RESs), thermal units, and energy storage systems (ESSs). The method is divided into two main parts. The first part is based on spinning reserve to overcome the load-generation imbalance in the network, while the second part is related to the spinning reserve for the outage of generation units. The total expected energy not supplied (TEENS) is the reliability criterion that determines the required spinning reserve. In the proposed formulation, generation units, the demand response (DR) program, and ESSs are capable of providing both types of reserves. The proposed method is evaluated using The Institute of Electrical and Electronics Engineers (IEEE) standard 30-bus and IEEE reliability test networks. The suggested structure has been implemented by General Algebraic Modeling System (GAMS), and the results indicate the appropriate performance of the proposed method.
- 1 December 2016
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 83, 411-425
Multi-agent systems for reactive power control in smart grids
- 1 December 2016
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 83, 411-425
Multi-agent systems for reactive power control in smart grids
- 8 January 2016
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 26 (8) , 1752-1782
Integration of the wind power plants through a novel, multi-objective control scheme under the normal and emergency conditions
- 8 January 2016
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 26 (8) , 1752-1782
Integration of the wind power plants through a novel, multi-objective control scheme under the normal and emergency conditions
- 1 January 2016
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 24 (5) , 4242-4253
A novel voltage control strategy in collaboration with information technology domains through the holonic architecture
- 1 January 2016
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in Turkish Journal of Electrical Engineering and Computer Sciences
- Vol. 24 (5) , 4242-4253
A novel voltage control strategy in collaboration with information technology domains through the holonic architecture
- Open Access
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 9 (14) , 1922-1934
Holonic structure: a state‐of‐the‐art control architecture based on multi‐agent systems for optimal reactive power dispatch in smart grids
This study presents a hierarchical distributed structure based on the Holonic concept for reactive power control in smart grids. Holons, as the main parts of the proposed framework, are able to negotiate together, change their boundaries, and alter the role of their members. These abilities improve the flexibility and performance of the novel structure in order to adapt itself to different situations. The proposed methodology is successfully scrutinised through different case studies based on a transmission test system connected to seven distribution networks. The new method is compared with two structures using a set of evaluation indices. The simulation results have revealed that improving the computational efficiency, minimising the active power losses and voltage deviations, optimal utilisation of reactive power sources, less data traffic loads, and increasing the fault tolerance are some key features of the proposed approach.
- 1 November 2015
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 9 (14) , 1922-1934
Open AccessHolonic structure: a state‐of‐the‐art control architecture based on multi‐agent systems for optimal reactive power dispatch in smart grids
This study presents a hierarchical distributed structure based on the Holonic concept for reactive power control in smart grids. Holons, as the main parts of the proposed framework, are able to negotiate together, change their boundaries, and alter the role of their members. These abilities improve the flexibility and performance of the novel structure in order to adapt itself to different situations. The proposed methodology is successfully scrutinised through different case studies based on a transmission test system connected to seven distribution networks. The new method is compared with two structures using a set of evaluation indices. The simulation results have revealed that improving the computational efficiency, minimising the active power losses and voltage deviations, optimal utilisation of reactive power sources, less data traffic loads, and increasing the fault tolerance are some key features of the proposed approach.
- 28 September 2015
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 26 (6) , 1184-1209
An effective decentralized scheme to monitor and control the reactive power flow: a holonic-based strategy
To determine an appropriate command in order to solve a problem throughout the power system operation, a comprehensive monitoring system must be in existence. Indeed, the operator must prioritize the monitoring of system at different levels to be capable of making a suitable decision. Like all of emerging problems concerned with the smart grid concept in the future power system, a need for continuous optimal reactive power dispatch (ORPD) forces the operator to monitor and control the gird, systematically. In this paper, a holonic-based framework for monitoring and control of the reactive power flow is presented. The holonic architecture has some interesting features by which objective functions of the ORPD could be optimized through a timely proposed strategy. At first, a holonic model is presented for all reactive power resources of the system. Then, some communication and calculation holon are considered, of which these holons have a transfer function application to monitor a related area according to the territory of their holon. Also, to decrease the number of corrective actions during the ORPD strategy, a priority list is defined for each medium voltage feeder holon. Deliberately, the Lagrangian relaxation algorithm is considered for each holon to optimize the reactive power flow locally. This method also is compatible with the proposed holonic-based reactive power framework. Finally, to assess the efficiency of the proposed framework, the suggested method is compared with previous reactive power control methods in a case study. Copyright © 2015 John Wiley & Sons, Ltd.
- 28 September 2015
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 26 (6) , 1184-1209
An effective decentralized scheme to monitor and control the reactive power flow: a holonic-based strategy
To determine an appropriate command in order to solve a problem throughout the power system operation, a comprehensive monitoring system must be in existence. Indeed, the operator must prioritize the monitoring of system at different levels to be capable of making a suitable decision. Like all of emerging problems concerned with the smart grid concept in the future power system, a need for continuous optimal reactive power dispatch (ORPD) forces the operator to monitor and control the gird, systematically. In this paper, a holonic-based framework for monitoring and control of the reactive power flow is presented. The holonic architecture has some interesting features by which objective functions of the ORPD could be optimized through a timely proposed strategy. At first, a holonic model is presented for all reactive power resources of the system. Then, some communication and calculation holon are considered, of which these holons have a transfer function application to monitor a related area according to the territory of their holon. Also, to decrease the number of corrective actions during the ORPD strategy, a priority list is defined for each medium voltage feeder holon. Deliberately, the Lagrangian relaxation algorithm is considered for each holon to optimize the reactive power flow locally. This method also is compatible with the proposed holonic-based reactive power framework. Finally, to assess the efficiency of the proposed framework, the suggested method is compared with previous reactive power control methods in a case study. Copyright © 2015 John Wiley & Sons, Ltd.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 42-47
An observability based monitoring scheme for voltage stability margin: A practical system case study
This paper presents a practical approach for voltage stability margin (VSM) monitoring in a pilot project, in which two related steps are considered. Through the planning stage of a practical project, it is necessary to make the grid observable to actualize the VSM monitoring during the operation. So, an observability based VSM monitoring scheme is proposed in this work. Firstly, using observability analysis and state estimation requirement, optimal location of metering devices is determined for the Hormoz distribution grid as a practical system case study. Secondly, using the information sent by metering devices, the VSM monitoring is evaluated using artificial neural network (ANN) application during the operation. To assess the performance of the proposed method, it is compared with a case, in which metering infrastructures are connected to the whole of buses. For further simulation, input data combinations of the ANN application are varied throughout two different scenarios.
- 1 April 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 42-47
An observability based monitoring scheme for voltage stability margin: A practical system case study
This paper presents a practical approach for voltage stability margin (VSM) monitoring in a pilot project, in which two related steps are considered. Through the planning stage of a practical project, it is necessary to make the grid observable to actualize the VSM monitoring during the operation. So, an observability based VSM monitoring scheme is proposed in this work. Firstly, using observability analysis and state estimation requirement, optimal location of metering devices is determined for the Hormoz distribution grid as a practical system case study. Secondly, using the information sent by metering devices, the VSM monitoring is evaluated using artificial neural network (ANN) application during the operation. To assess the performance of the proposed method, it is compared with a case, in which metering infrastructures are connected to the whole of buses. For further simulation, input data combinations of the ANN application are varied throughout two different scenarios.
- Open Access
- 1 December 2014
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 8 (12) , 2183-2198
Environmental/economic dispatch incorporating renewable energy sources and plug‐in vehicles
Transportation and electricity industries are considered as major sources of greenhouse gases (GHGs) emission. Different methods have been proposed to deal with the increasing rate of the emission, such as employing plug‐in electric vehicles (PEVs) and integrating renewable energy sources (RESs). However, it is important to scrutinise different scenarios of incorporating the mentioned elements to decrease the concerning emission rate while considering the economic constraints. In this study, a combined economic emission dispatch (CEED) is employed to investigate the effectiveness of using PEVs and RESs from different aspects. A sensitivity analysis is executed to survey the influence of emission and cost coefficients. Two test cases each including different scenarios are simulated to determine the efficacy of different types of integration in the proposed model. To have a more accurate and realistic survey, an extended model of the wind farm's cost function is employed in economic dispatch calculations. The particle swarm optimisation algorithm is applied to solve the CEED non‐linear problem. The obtained results indicate that the integration of PEVs cannot necessarily reduce the net emission of two industries. In fact, the optimum solution should include the incorporation of PEVs along with RESs to return the desired results.
- 1 December 2014
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 8 (12) , 2183-2198
Open AccessEnvironmental/economic dispatch incorporating renewable energy sources and plug‐in vehicles
Transportation and electricity industries are considered as major sources of greenhouse gases (GHGs) emission. Different methods have been proposed to deal with the increasing rate of the emission, such as employing plug‐in electric vehicles (PEVs) and integrating renewable energy sources (RESs). However, it is important to scrutinise different scenarios of incorporating the mentioned elements to decrease the concerning emission rate while considering the economic constraints. In this study, a combined economic emission dispatch (CEED) is employed to investigate the effectiveness of using PEVs and RESs from different aspects. A sensitivity analysis is executed to survey the influence of emission and cost coefficients. Two test cases each including different scenarios are simulated to determine the efficacy of different types of integration in the proposed model. To have a more accurate and realistic survey, an extended model of the wind farm's cost function is employed in economic dispatch calculations. The particle swarm optimisation algorithm is applied to solve the CEED non‐linear problem. The obtained results indicate that the integration of PEVs cannot necessarily reduce the net emission of two industries. In fact, the optimum solution should include the incorporation of PEVs along with RESs to return the desired results.
- Open Access
- 1 January 2014
- Published by Science and Engineering Publishing Company in International Journal of Energy Science
- Vol. 4 (2) , 60
Combined Economic and Emission Dispatch Incorporating Renewable Energy Sources and Plug-In Hybrid Electric Vehicles
- 1 January 2014
- Published by Science and Engineering Publishing Company in International Journal of Energy Science
- Vol. 4 (2) , 60
Open AccessCombined Economic and Emission Dispatch Incorporating Renewable Energy Sources and Plug-In Hybrid Electric Vehicles
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 153-159
Optimal distribution voltage control through a sub-framework in the reactive power management on the Smart Grid
The large-scale deployment of the Smart Grid will support the evolution of conventional electrical power systems toward active, flexible and automatic troubleshooter energy networks composed of renewable energy resources. With the increasing penetration of renewable energies as distributed generation (DG) in smart grid scheme, technical problems arise in both distribution and transmission system level. The undesirable voltage is the main problem for connection of DGs in distribution systems, while excessive reactive power demand from transmission system is the major concern for Transmission System Operators (TSO). This paper presents a new sub-framework in the reactive power management to optimal control of voltage in the suitable range by decreasing the voltage deviation and obtain high voltage stability margin, simultaneously. In this work, the required voltage profile, by set of controllable variables in power system such as tap of transformers, value of capacitors is investigated. To determination the value of elements in the mentioned sub-framework, the Particle Swarm Optimization (PSO) method is employed to rapidly obtain the optimum parameters due to improvement of voltage profile. Finally, the proposed method is implemented on the standard IEEE- 24 bus and IEEE-16 bus distribution system the results are compared to each other.
- 1 December 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 153-159
Optimal distribution voltage control through a sub-framework in the reactive power management on the Smart Grid
The large-scale deployment of the Smart Grid will support the evolution of conventional electrical power systems toward active, flexible and automatic troubleshooter energy networks composed of renewable energy resources. With the increasing penetration of renewable energies as distributed generation (DG) in smart grid scheme, technical problems arise in both distribution and transmission system level. The undesirable voltage is the main problem for connection of DGs in distribution systems, while excessive reactive power demand from transmission system is the major concern for Transmission System Operators (TSO). This paper presents a new sub-framework in the reactive power management to optimal control of voltage in the suitable range by decreasing the voltage deviation and obtain high voltage stability margin, simultaneously. In this work, the required voltage profile, by set of controllable variables in power system such as tap of transformers, value of capacitors is investigated. To determination the value of elements in the mentioned sub-framework, the Particle Swarm Optimization (PSO) method is employed to rapidly obtain the optimum parameters due to improvement of voltage profile. Finally, the proposed method is implemented on the standard IEEE- 24 bus and IEEE-16 bus distribution system the results are compared to each other.