Simon Bernard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Simon Bernard has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Quentin Grimal
Sorbonne Université, Inserm, CNRS, Laboratoire d'Imagerie Biomédicale, LIB, Paris, France
8 shared publications - Pascal Laugier
Sorbonne Universités, UPMC Univ Paris 06, CNRS, INSERM, Laboratoire d'Imagerie Biomédicale (LIB), 15 rue de l'école de médecine, 75006, Paris, France
7 shared publications - Guy Cloutier
University of Montreal
4 shared publications - Pierre Maréchal
Laboratory of Waves and Complex Media (LOMC), UMR 6294, CNRS, University of Le Havre Normandy, Le Havre, France
3 shared publications Kay Raum
Julius-Wolff-Institute & Berlin Brandenburg School for Regenerative Therapies, Charité-Universitätsmedizin Berlin, Berlin, Germany
2 shared publicationsLia Gomes Paim
Univ. of Montreal Hospital Res. Ctr., Montreal, QC, Canada
2 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Resonant ultrasound spectroscopy for the viscoelastic characterization of cortical bone
Spectroscopie par résonance ultrasonore pour la caractérisation viscoélastique de l'os cortical: Une meilleure compréhension des relations entre la structure complexe de l'os cortical et ses propriétés mécaniques est nécessaire à l'évaluation de la qualité osseuse. Les méthodes conventionnelles ex vivo de mesure de l'élasticité à l'échelle du millimètre ont des limitations liées à l'anisotropie du tissu, à son inhomogénéité et à la petite taille des échantillons. Au contraire, la spectroscopie par résonance ultrasonore (RUS) est bien adaptée à la mesure de petits échantillons anisotropes. Cette méthode estime l'élasticité à partir des fréquences de résonance de l'échantillon, et l'amortissement à partir de la largeur des pics de résonance. Son application à l'os était considérée difficile, du fait de l'amortissement important des modes de vibration, qui induit un recouvrement des pics de résonance et complique la mesure des fréquences. Pour surmonter cette difficulté, des adaptions de la méthode - dans la mesure, le traitement du signal et l'estimation des propriétés du matériau - ont été proposées. Elles ont été validées sur de l'os cortical et sur des échantillons de polymère et de matériau composite imitant l'os. La précision de la méthode a été démontrée, ainsi que sa capacité à mesurer tous les termes du tenseur d'élasticité à partir d'un seul échantillon. De plus, une nouvelle formulation Bayésienne de l'inversion apporte une solution automatique à un problème qui nécessitait une stratégie fastidieuse d'essai-erreur ou de complexes modifications du dispositif expérimental. Finalement, l'application à une grande collection d'échantillons de tibias humains démontre que la méthode RUS pourrait être utilisée en routine pour la mesure de la viscoélasticité de l'os.
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Resonant ultrasound spectroscopy for the viscoelastic characterization of cortical bone
Spectroscopie par résonance ultrasonore pour la caractérisation viscoélastique de l'os cortical: Une meilleure compréhension des relations entre la structure complexe de l'os cortical et ses propriétés mécaniques est nécessaire à l'évaluation de la qualité osseuse. Les méthodes conventionnelles ex vivo de mesure de l'élasticité à l'échelle du millimètre ont des limitations liées à l'anisotropie du tissu, à son inhomogénéité et à la petite taille des échantillons. Au contraire, la spectroscopie par résonance ultrasonore (RUS) est bien adaptée à la mesure de petits échantillons anisotropes. Cette méthode estime l'élasticité à partir des fréquences de résonance de l'échantillon, et l'amortissement à partir de la largeur des pics de résonance. Son application à l'os était considérée difficile, du fait de l'amortissement important des modes de vibration, qui induit un recouvrement des pics de résonance et complique la mesure des fréquences. Pour surmonter cette difficulté, des adaptions de la méthode - dans la mesure, le traitement du signal et l'estimation des propriétés du matériau - ont été proposées. Elles ont été validées sur de l'os cortical et sur des échantillons de polymère et de matériau composite imitant l'os. La précision de la méthode a été démontrée, ainsi que sa capacité à mesurer tous les termes du tenseur d'élasticité à partir d'un seul échantillon. De plus, une nouvelle formulation Bayésienne de l'inversion apporte une solution automatique à un problème qui nécessitait une stratégie fastidieuse d'essai-erreur ou de complexes modifications du dispositif expérimental. Finalement, l'application à une grande collection d'échantillons de tibias humains démontre que la méthode RUS pourrait être utilisée en routine pour la mesure de la viscoélasticité de l'os.
- 13 May 2025
- Published by Springer Nature
- p. 317-326
Influence of the Number of Contours of a Specimen Manufactured by FFF on the Propagation of Acoustic Waves
- 13 May 2025
- Published by Springer Nature
- p. 317-326
Influence of the Number of Contours of a Specimen Manufactured by FFF on the Propagation of Acoustic Waves
- Open Access
- 17 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (3)
Efficient asymmetrical transmission through a metagrating for underwater acoustic waves
Acoustic asymmetrical transmission is a theoretical and engineering challenge because of the reciprocity of the linear acoustic wave equation. It can be achieved by systems breaking reciprocity or by reciprocal systems relying solely on spatial symmetry breaking. Metagratings are planar structures relying on Bragg's diffraction to reroute wave energy toward a desired direction and are eventually able to achieve asymmetrical transmission when build from an asymmetrical pattern of multiple basic elements. The challenge for water-like media is to combine the geometrical complexity of the structure with good acoustic impedance contrast and practical feasibility. In this work, we build a reciprocal metagrating from brass cylinders arranged according to a numerically optimized pattern and obtain highly efficient asymmetrical transmission for underwater acoustic waves. Around 200 kHz, the structure transmits nearly all incident energy toward a 45° angle when insonified from one side, but act as a near perfect reflector when insonified from the other. The effect relies entirely on the simple phenomena of linear wave diffraction and interference. The generality and efficiency of this device could be of interest for applications in underwater acoustics or medical ultrasounds.
- 17 July 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (3)
Open AccessEfficient asymmetrical transmission through a metagrating for underwater acoustic waves
Acoustic asymmetrical transmission is a theoretical and engineering challenge because of the reciprocity of the linear acoustic wave equation. It can be achieved by systems breaking reciprocity or by reciprocal systems relying solely on spatial symmetry breaking. Metagratings are planar structures relying on Bragg's diffraction to reroute wave energy toward a desired direction and are eventually able to achieve asymmetrical transmission when build from an asymmetrical pattern of multiple basic elements. The challenge for water-like media is to combine the geometrical complexity of the structure with good acoustic impedance contrast and practical feasibility. In this work, we build a reciprocal metagrating from brass cylinders arranged according to a numerically optimized pattern and obtain highly efficient asymmetrical transmission for underwater acoustic waves. Around 200 kHz, the structure transmits nearly all incident energy toward a 45° angle when insonified from one side, but act as a near perfect reflector when insonified from the other. The effect relies entirely on the simple phenomena of linear wave diffraction and interference. The generality and efficiency of this device could be of interest for applications in underwater acoustics or medical ultrasounds.
- 22 February 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (2) , 024059
Broadband Negative Reflection of Underwater Acoustic Waves from a Simple Metagrating: Modeling and Experiment
Metagratings are periodic arrays of subwavelength scatterers, or atoms, engineered to refract or reflect waves toward anomalous directions with unit efficiency. Here, we design and build a metagrating to control the reflection direction of waterborne ultrasound waves impinging on a rigid or free surface. The grating and its atoms are designed to cancel the specular reflection and to redirect acoustic power toward a negative-reflection direction, through the first-negative-order Floquet mode. Despite a simple design, based on C-shaped brass particles acting as Helmholtz resonators, the grating is efficient () over a relatively broad range of frequencies (74–103 kHz) for a broad range of incidence angles (–). This good performance is obtained by tuning the distance between the atoms and the reflective surface. A multiple-scattering analytical model is presented to explain the phenomenon and a finite-element model is developed to further investigate the performance of the proposed design. Predictions from the model are confirmed experimentally in a water tank. The simplicity, reconfigurability, and scalability of the design, as well as its high efficiency, broadband behavior, and robustness to the incidence angle are all features that make the grating potentially useful for various applications in underwater acoustics, such as telemetry, communication, or noise mitigation.- 22 February 2022
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 17 (2) , 024059
Broadband Negative Reflection of Underwater Acoustic Waves from a Simple Metagrating: Modeling and Experiment
Metagratings are periodic arrays of subwavelength scatterers, or atoms, engineered to refract or reflect waves toward anomalous directions with unit efficiency. Here, we design and build a metagrating to control the reflection direction of waterborne ultrasound waves impinging on a rigid or free surface. The grating and its atoms are designed to cancel the specular reflection and to redirect acoustic power toward a negative-reflection direction, through the first-negative-order Floquet mode. Despite a simple design, based on C-shaped brass particles acting as Helmholtz resonators, the grating is efficient () over a relatively broad range of frequencies (74–103 kHz) for a broad range of incidence angles (–). This good performance is obtained by tuning the distance between the atoms and the reflective surface. A multiple-scattering analytical model is presented to explain the phenomenon and a finite-element model is developed to further investigate the performance of the proposed design. Predictions from the model are confirmed experimentally in a water tank. The simplicity, reconfigurability, and scalability of the design, as well as its high efficiency, broadband behavior, and robustness to the incidence angle are all features that make the grating potentially useful for various applications in underwater acoustics, such as telemetry, communication, or noise mitigation.- 25 November 2021
- Published by Springer Nature
- Vol. 1364, 253-277
Measurement of Cortical Bone Elasticity Tensor with Resonant Ultrasound Spectroscopy
Resonant Ultrasound Spectroscopy estimates the stiffness coefficients of a material from the free resonant frequencies of a single specimen. It is particularly suitable for complete stiffness characterization of anisotropic materials available only as small samples (typically a few mm), and it does not suffer from some limitations associated to quasi-static mechanical test and ultrasound wave velocity measurements. RUS has been used for decades on geological samples and single crystals, but was until recently not applied to mineralized tissues such as bone. The reason is the significant mechanical damping presents in these materials, which causes the resonant peaks to overlap and prevent a direct measurement of the resonant frequencies. This chapter describes the use of RUS for the elastic characterization of mineralized tissues, cortical bone in particular. All steps are described, from sample preparation and measurement setup to signal processing and data analysis, including the developments and adaptions necessary to overcome the difficulties linked to damping. Viscoelastic characterization, from the width of the resonant peaks, is also presented. Mostly technical aspects are developed in this chapter, while the data obtained from RUS on several collections of mineralized tissues specimens are presented and discussed in Chap. 13. Keywords Cortical bone Elasticity Tensor Viscoelasticity Damping Inverse problem Vibration
- 25 November 2021
- Published by Springer Nature
- Vol. 1364, 253-277
Measurement of Cortical Bone Elasticity Tensor with Resonant Ultrasound Spectroscopy
Resonant Ultrasound Spectroscopy estimates the stiffness coefficients of a material from the free resonant frequencies of a single specimen. It is particularly suitable for complete stiffness characterization of anisotropic materials available only as small samples (typically a few mm), and it does not suffer from some limitations associated to quasi-static mechanical test and ultrasound wave velocity measurements. RUS has been used for decades on geological samples and single crystals, but was until recently not applied to mineralized tissues such as bone. The reason is the significant mechanical damping presents in these materials, which causes the resonant peaks to overlap and prevent a direct measurement of the resonant frequencies. This chapter describes the use of RUS for the elastic characterization of mineralized tissues, cortical bone in particular. All steps are described, from sample preparation and measurement setup to signal processing and data analysis, including the developments and adaptions necessary to overcome the difficulties linked to damping. Viscoelastic characterization, from the width of the resonant peaks, is also presented. Mostly technical aspects are developed in this chapter, while the data obtained from RUS on several collections of mineralized tissues specimens are presented and discussed in Chap. 13. Keywords Cortical bone Elasticity Tensor Viscoelasticity Damping Inverse problem Vibration
- 1 February 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 90, 40-44
Assessment of elastic coefficients of child cortical bone using resonant ultrasound spectroscopy
- 1 February 2019
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 90, 40-44
Assessment of elastic coefficients of child cortical bone using resonant ultrasound spectroscopy
- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Signal Processing
- Vol. 67 (1) , 4-16
Lorentzian-Model-Based Bayesian Analysis for Automated Estimation of Attenuated Resonance Spectrum
Extracting information from a signal exhibiting damped resonances is a challenging task in many practical cases due to the presence of noise and high-attenuation. The interpretation of the signal relies on a model whose order (\textit{i.e.}, the number of resonances) is in general unknown. In this study, the signal is modelled as a sum of Lorentzian lineshapes and a Bayesian framework is designed to simultaneously remove the baseline distortion, select the number of resonances and recover the parameters of each lineshape including frequency, damping factor, resonance amplitude, and noise magnitude. The Bayesian problem is solved resorting to a reversible jump Markov chain Monte Carlo (RJ-MCMC) technique. The algorithm is tested on synthetic signals as well as experimental data from a resonant ultrasound spectroscopy experiment aiming to measure elastic properties. The results show that, compared to the well-known linear prediction singular value decomposition (LPSVD) method, the RJ-MCMC method achieves a better performance with the advantages of joint model selection, high accuracy estimation, and uncertainty evaluation. We found that when the signal-to-noise-ratio is larger than 20~dB, the average relative error for frequency extraction is smaller than $0.5\%$ . Such an algorithm enables to estimate the number of resonances and extract tens of resonance parameters from a highly-attenuated spectrum, which can significantly facilitate the automated processing of the signals exhibiting damped resonances.- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Signal Processing
- Vol. 67 (1) , 4-16
Lorentzian-Model-Based Bayesian Analysis for Automated Estimation of Attenuated Resonance Spectrum
Extracting information from a signal exhibiting damped resonances is a challenging task in many practical cases due to the presence of noise and high-attenuation. The interpretation of the signal relies on a model whose order (\textit{i.e.}, the number of resonances) is in general unknown. In this study, the signal is modelled as a sum of Lorentzian lineshapes and a Bayesian framework is designed to simultaneously remove the baseline distortion, select the number of resonances and recover the parameters of each lineshape including frequency, damping factor, resonance amplitude, and noise magnitude. The Bayesian problem is solved resorting to a reversible jump Markov chain Monte Carlo (RJ-MCMC) technique. The algorithm is tested on synthetic signals as well as experimental data from a resonant ultrasound spectroscopy experiment aiming to measure elastic properties. The results show that, compared to the well-known linear prediction singular value decomposition (LPSVD) method, the RJ-MCMC method achieves a better performance with the advantages of joint model selection, high accuracy estimation, and uncertainty evaluation. We found that when the signal-to-noise-ratio is larger than 20~dB, the average relative error for frequency extraction is smaller than $0.5\%$ . Such an algorithm enables to estimate the number of resonances and extract tens of resonance parameters from a highly-attenuated spectrum, which can significantly facilitate the automated processing of the signals exhibiting damped resonances.- 1 September 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (3_Suppleme) , 1746
Cell quake elastography
- 1 September 2018
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 144 (3_Suppleme) , 1746
Cell quake elastography