Wei-Feng Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei-Feng Fang has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Jing-Tang Yang
8 shared publicationsYu-Tzu Chen
Department of Mechanical Engineering, National Taiwan University, No.1, Sec. 4, Roosevelt Road, Taipei 10617, Taiwan
7 shared publications- Jing-Tang Yang
Department of Mechanical Engineering, National Taiwan University, Taipei 10617, Taiwan
5 shared publications Miao-Hsing Hsu
National Taiwan University Department of Mechanical Engineering Taipei 10617, Taiwan
3 shared publications- Jim-Min Fang
Department of Chemistry, National Taiwan University, Taipei 106, Taiwan
2 shared publications Shang-Chieh Ting
National Taiwan University
2 shared publications
Latest Publications
- 1 March 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 192, 77-82
Colorimetric determination of DNA concentration and mismatches using hybridization-mediated growth of gold nanoparticle probes
- 1 March 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 192, 77-82
Colorimetric determination of DNA concentration and mismatches using hybridization-mediated growth of gold nanoparticle probes
- 1 December 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 50, 8-13
DNA diagnosis in a microseparator based on particle aggregation
- 1 December 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 50, 8-13
DNA diagnosis in a microseparator based on particle aggregation
- 21 November 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 14 (5) , 785-795
Droplets coalescence and mixing with identical and distinct surface tension on a wettability gradient surface
- 21 November 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 14 (5) , 785-795
Droplets coalescence and mixing with identical and distinct surface tension on a wettability gradient surface
- 6 September 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (22) , 4870-4876
Particle chain display – an optofluidic electronic paper
A particle-based display medium and a driving mechanism insensitive to the charge polarity of those particles, based on the transformation of particle chains, are developed for reflective electronic paper displays. Particle chains are formed by dipole–dipole interactions between polarized particles with an appropriate electric field applied across the tested display medium, i.e. the solution that regulates the light in the field of display technology, containing neutral polystyrene (PS) particles dispersed in water. Formation of the particle chains results in a large change in optical transmittance and reflectance of the display medium. The performance of the particle chain displays (PCD) was evaluated according to macroscopic (device), microscopic (particle) and optical (reflectance) points of view. A display medium (thickness 100 μm) containing colored PS particles (3 μm, 2.5% w/v) was polarized to display the fixed images of the directly driven electrodes and programmable images of arrayed (5 × 5) electrodes with electric fields (0.48 MV m−1 and 0.09 MV m−1, 500 kHz, respectively). The formation of particle chains under electric fields (0.2 MV m−1 and 0.4 MV m−1, 500 kHz) was observed in the microscopic images of a display medium (thickness 100 μm) with fluorescent PS particles (5 μm, 1%). Images recorded with a confocal microscope demonstrated the particle chains. The opacity, a common parameter serving to characterize a display medium, was derived by measuring the reflectance ratio of a black background to a white background of the display medium with varied thickness and particle concentration. The temporal response of a display medium (thickness 50 μm) with black PS particles (3 μm, 5%) was tested. When an electric field (0.6 MV m−1, 500 kHz) was applied, the reflectance increased twice at the first data point in 0.7 s, attaining a contrast ratio of 2. Application of a voltage (20 s) yielded a contrast ratio of 10. The performance of a tested display medium, composed of simple PS particles and water and driven to form particle chains by polarization, is reported.
- 6 September 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (22) , 4870-4876
Particle chain display – an optofluidic electronic paper
A particle-based display medium and a driving mechanism insensitive to the charge polarity of those particles, based on the transformation of particle chains, are developed for reflective electronic paper displays. Particle chains are formed by dipole–dipole interactions between polarized particles with an appropriate electric field applied across the tested display medium, i.e. the solution that regulates the light in the field of display technology, containing neutral polystyrene (PS) particles dispersed in water. Formation of the particle chains results in a large change in optical transmittance and reflectance of the display medium. The performance of the particle chain displays (PCD) was evaluated according to macroscopic (device), microscopic (particle) and optical (reflectance) points of view. A display medium (thickness 100 μm) containing colored PS particles (3 μm, 2.5% w/v) was polarized to display the fixed images of the directly driven electrodes and programmable images of arrayed (5 × 5) electrodes with electric fields (0.48 MV m−1 and 0.09 MV m−1, 500 kHz, respectively). The formation of particle chains under electric fields (0.2 MV m−1 and 0.4 MV m−1, 500 kHz) was observed in the microscopic images of a display medium (thickness 100 μm) with fluorescent PS particles (5 μm, 1%). Images recorded with a confocal microscope demonstrated the particle chains. The opacity, a common parameter serving to characterize a display medium, was derived by measuring the reflectance ratio of a black background to a white background of the display medium with varied thickness and particle concentration. The temporal response of a display medium (thickness 50 μm) with black PS particles (3 μm, 5%) was tested. When an electric field (0.6 MV m−1, 500 kHz) was applied, the reflectance increased twice at the first data point in 0.7 s, attaining a contrast ratio of 2. Application of a voltage (20 s) yielded a contrast ratio of 10. The performance of a tested display medium, composed of simple PS particles and water and driven to form particle chains by polarization, is reported.
- 1 August 2012
- Published by Elsevier in Chemical Engineering Journal
- Vol. 198-199, 33-37
Microflow synthesis of saccharide nucleoside diphosphate with cross-coupling reactions of monophosphate components
- 1 August 2012
- Published by Elsevier in Chemical Engineering Journal
- Vol. 198-199, 33-37
Microflow synthesis of saccharide nucleoside diphosphate with cross-coupling reactions of monophosphate components
- 22 February 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (2) , 239-247
Fission and fusion of droplets in a 3-D crossing microstructure
- 22 February 2012
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 13 (2) , 239-247
Fission and fusion of droplets in a 3-D crossing microstructure
- 1 January 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (5) , 923-931
Locally enhanced concentration and detection of oligonucleotides in a plug-based microfluidic device
We propose a novel technique that allows oligonucleotides with specific end-modification within a plug in a plug-based microfluidic device to undergo a locally enhanced concentration at the rear of the plug as the plug moves downstream. DNA was enriched and detected in situ upon exploiting a combined effect underlain by an entropic force induced through fluid shear (i.e. a hydrodynamic-repellent effect) and the interfacial adsorption (aqueous/oil interface) attributed to affinity. Flow fields within a plug were visualized quantitatively using micro-particle image velocimetry (micro-PIV); the distribution of the fluid shear strain rate explains how the hydrodynamic-repellent effect engenders a dumbbell-like region with an increased concentration of DNA. The concentration of FAM (6-carboxy-fluorescein)-labeled DNA (FC-DNA) and of TAMRA (tetramethyl-6-carboxyrhodamine)-labeled DNA (TC-DNA), respectively, and the hybridization of probe DNA (modified with FAM) with target DNA (modified with TAMRA) were investigated in devices; a confocal fluorescence microscope (CFM) was utilized to monitor the processes and to resolve the corresponding 2D patterns and 3D reconstruction of the DNA distribution in a plug. TC-DNA, but not FC-DNA, concentrating within a plug was affected by the combined effect so as to achieve a concentration factor (Cr) twice that of FC-DNA because of the lipophilicity of TAMRA. Using fluorescence resonance-energy transfer (FRET), we characterized the hybridization of the DNA in a plug; the detection limit of a system, improved by virtue of the proposed technique (the locally enhanced concentration), for DNA detection was estimated to be 20–50 nM. This technique enables DNA to concentrate locally in a nL–pL free-solution plug, the locally enhanced concentration to profit the hybridization efficiency and the detection of DNA, prospectively serving as a versatile means to accomplish a rapid DNA detection in a small volume for a Lab-on-a-Chip (LOC) system.
- 1 January 2012
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 12 (5) , 923-931
Locally enhanced concentration and detection of oligonucleotides in a plug-based microfluidic device
We propose a novel technique that allows oligonucleotides with specific end-modification within a plug in a plug-based microfluidic device to undergo a locally enhanced concentration at the rear of the plug as the plug moves downstream. DNA was enriched and detected in situ upon exploiting a combined effect underlain by an entropic force induced through fluid shear (i.e. a hydrodynamic-repellent effect) and the interfacial adsorption (aqueous/oil interface) attributed to affinity. Flow fields within a plug were visualized quantitatively using micro-particle image velocimetry (micro-PIV); the distribution of the fluid shear strain rate explains how the hydrodynamic-repellent effect engenders a dumbbell-like region with an increased concentration of DNA. The concentration of FAM (6-carboxy-fluorescein)-labeled DNA (FC-DNA) and of TAMRA (tetramethyl-6-carboxyrhodamine)-labeled DNA (TC-DNA), respectively, and the hybridization of probe DNA (modified with FAM) with target DNA (modified with TAMRA) were investigated in devices; a confocal fluorescence microscope (CFM) was utilized to monitor the processes and to resolve the corresponding 2D patterns and 3D reconstruction of the DNA distribution in a plug. TC-DNA, but not FC-DNA, concentrating within a plug was affected by the combined effect so as to achieve a concentration factor (Cr) twice that of FC-DNA because of the lipophilicity of TAMRA. Using fluorescence resonance-energy transfer (FRET), we characterized the hybridization of the DNA in a plug; the detection limit of a system, improved by virtue of the proposed technique (the locally enhanced concentration), for DNA detection was estimated to be 20–50 nM. This technique enables DNA to concentrate locally in a nL–pL free-solution plug, the locally enhanced concentration to profit the hybridization efficiency and the detection of DNA, prospectively serving as a versatile means to accomplish a rapid DNA detection in a small volume for a Lab-on-a-Chip (LOC) system.
- 1 October 2011
- Published by Elsevier in Chemical Engineering Journal
- Vol. 174 (1) , 421-424
Flash synthesis of carbohydrate derivatives in chaotic microreactors
- 1 October 2011
- Published by Elsevier in Chemical Engineering Journal
- Vol. 174 (1) , 421-424
Flash synthesis of carbohydrate derivatives in chaotic microreactors
- 17 April 2011
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 11 (3) , 339-352
Analysis of chaos and FRET reaction in split-and-recombine microreactors
- 17 April 2011
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 11 (3) , 339-352
Analysis of chaos and FRET reaction in split-and-recombine microreactors
- 1 March 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (1) , 014111
Characterization of microfluidic mixing and reaction in microchannels via analysis of cross-sectional patterns
For the diagnosis of biochemical reactions, the investigation of microflow behavior, and the confirmation of simulation results in microfluidics, experimentally quantitative measurements are indispensable. To characterize the mixing and reaction of fluids in microchannel devices, we propose a mixing quality index to quantify the cross-sectional patterns (also called mixing patterns) of fluids, captured with a confocal-fluorescence microscope (CFM). The operating parameters of the CFM for quantification were carefully tested. We analyzed mixing patterns, flow advection, and mass exchange of fluids in the devices with overlapping channels of two kinds. The mixing length of the two devices derived from the analysis of is demonstrated to be more precise than that estimated with a commonly applied method of blending dye liquors. By means of fluorescence resonance-energy transfer (FRET), we monitored the hybridization of two complementary oligonucleotides (a FRET pair) in the devices. The captured patterns reveal that hybridization is a progressive process along the downstream channel. The FRET reaction and the hybridization period were characterized through quantification of the reaction patterns. This analytical approach is a promising diagnostic tool that is applicable to the real-time analysis of biochemical and chemical reactions such as polymerase chain reaction (PCR), catalytic, or synthetic processes in microfluidic devices.- 1 March 2011
- Published by AIP Publishing in Biomicrofluidics
- Vol. 5 (1) , 014111
Characterization of microfluidic mixing and reaction in microchannels via analysis of cross-sectional patterns
For the diagnosis of biochemical reactions, the investigation of microflow behavior, and the confirmation of simulation results in microfluidics, experimentally quantitative measurements are indispensable. To characterize the mixing and reaction of fluids in microchannel devices, we propose a mixing quality index to quantify the cross-sectional patterns (also called mixing patterns) of fluids, captured with a confocal-fluorescence microscope (CFM). The operating parameters of the CFM for quantification were carefully tested. We analyzed mixing patterns, flow advection, and mass exchange of fluids in the devices with overlapping channels of two kinds. The mixing length of the two devices derived from the analysis of is demonstrated to be more precise than that estimated with a commonly applied method of blending dye liquors. By means of fluorescence resonance-energy transfer (FRET), we monitored the hybridization of two complementary oligonucleotides (a FRET pair) in the devices. The captured patterns reveal that hybridization is a progressive process along the downstream channel. The FRET reaction and the hybridization period were characterized through quantification of the reaction patterns. This analytical approach is a promising diagnostic tool that is applicable to the real-time analysis of biochemical and chemical reactions such as polymerase chain reaction (PCR), catalytic, or synthetic processes in microfluidic devices.