Richard Leslie Abel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard Leslie Abel has a total of 103 co-authors. Here are the top co-authors by number of shared publications:
- Justin Peter Cobb
MSK Lab, Imperial College London, London, UK
6 shared publications Ulrich Hansen
5 shared publications- Ulrich Hansen
Department of Mechanical Engineering, Faculty of Engineering, Imperial College London, London SW7 2AZ, UK
3 shared publications Alan Courtney
Clinical Biochemistry, North West London Pathology, Charing Cross Hospital, Imperial College NHS Healthcare, London, UK
2 shared publicationsAngelo Karunaratne
Department of Mechanical Engineering, Faculty of Engineering, University of Moratuwa, Moratuwa, 10400, Sri Lanka
2 shared publicationsFrancesca Bladt
Faculty of Medicine, MSk Lab, Department of Surgery and Cancer, Imperial College, London, UK
2 shared publications
Latest Publications
- Open Access
- 3 July 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (3) , 63
Quantifying Brittle Crack Opening in Human Trabecular Bone Using Synchrotron XCT–DVC
Background/Objectives: Trabecular bone exhibits brittle behaviour governed by microscale deformation and damage, yet quantifying crack progression is difficult because classical fracture-mechanics approaches do not apply to architecturally discontinuous porous tissue. This pilot study evaluates whether synchrotron X-ray computed tomography (XCT) combined with digital volume correlation (DVC) can provide a practical, geometry-normalised approach for quantifying crack-opening behaviour in human trabecular bone. Methods: Semicylindrical specimens from femoral heads of hip-fracture donors (n = 5) and non-fracture controls (n = 5) underwent stepwise three-point bending during XCT imaging. Full-field displacement maps were used to measure crack mouth opening displacement (CMOD), crack length (a), and their ratio CMOD/a, used here as a geometry-normalised comparative descriptor of brittle response rather than an intrinsic material property. Automated phase-congruency crack detection (PCCD) was compared with manual measurement. Results: XCT–DVC resolved three-dimensional displacement discontinuities during crack initiation and propagation in all specimens. Hip-fracture donors exhibited significantly lower critical crack-opening ratios (CMOD/a)* than Controls (median 0.31 vs. 0.47; p = 0.008) and reached instability at lower applied loads. Total crack extension (Δa*) was similar between groups. Automated crack tracking using phase-congruency-based segmentation showed excellent agreement with manual measurements (r2 = 0.98), supporting reliable extraction of crack geometry from DVC displacement fields. Conclusions: In this small pilot sample, XCT–DVC provided a feasible, geometry-normalised approach for comparing crack-opening behaviour where classical fracture-mechanics parameters cannot be applied. The close agreement between automated and manual crack measurements supports the reproducibility of the displacement-based measurement pipeline. The lower critical CMOD/a in hip-fracture specimens may indicate a more brittle comparative response. However, given the small sample, differing sex distribution, and lower bone volume fraction in the hip-fracture group, these findings are preliminary and require confirmation in larger cohorts. Establishing whether the observed difference reflects intrinsic tissue brittleness, architectural factors, or both is an important objective for future work in microstructure-matched cohorts.
- 3 July 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (3) , 63
Open AccessQuantifying Brittle Crack Opening in Human Trabecular Bone Using Synchrotron XCT–DVC
Background/Objectives: Trabecular bone exhibits brittle behaviour governed by microscale deformation and damage, yet quantifying crack progression is difficult because classical fracture-mechanics approaches do not apply to architecturally discontinuous porous tissue. This pilot study evaluates whether synchrotron X-ray computed tomography (XCT) combined with digital volume correlation (DVC) can provide a practical, geometry-normalised approach for quantifying crack-opening behaviour in human trabecular bone. Methods: Semicylindrical specimens from femoral heads of hip-fracture donors (n = 5) and non-fracture controls (n = 5) underwent stepwise three-point bending during XCT imaging. Full-field displacement maps were used to measure crack mouth opening displacement (CMOD), crack length (a), and their ratio CMOD/a, used here as a geometry-normalised comparative descriptor of brittle response rather than an intrinsic material property. Automated phase-congruency crack detection (PCCD) was compared with manual measurement. Results: XCT–DVC resolved three-dimensional displacement discontinuities during crack initiation and propagation in all specimens. Hip-fracture donors exhibited significantly lower critical crack-opening ratios (CMOD/a)* than Controls (median 0.31 vs. 0.47; p = 0.008) and reached instability at lower applied loads. Total crack extension (Δa*) was similar between groups. Automated crack tracking using phase-congruency-based segmentation showed excellent agreement with manual measurements (r2 = 0.98), supporting reliable extraction of crack geometry from DVC displacement fields. Conclusions: In this small pilot sample, XCT–DVC provided a feasible, geometry-normalised approach for comparing crack-opening behaviour where classical fracture-mechanics parameters cannot be applied. The close agreement between automated and manual crack measurements supports the reproducibility of the displacement-based measurement pipeline. The lower critical CMOD/a in hip-fracture specimens may indicate a more brittle comparative response. However, given the small sample, differing sex distribution, and lower bone volume fraction in the hip-fracture group, these findings are preliminary and require confirmation in larger cohorts. Establishing whether the observed difference reflects intrinsic tissue brittleness, architectural factors, or both is an important objective for future work in microstructure-matched cohorts.
- Open Access
The Molecular Origin of Water-Mediated Collagen Contraction
The mechanical toughness of bone and teeth relies on residual stresses generated during mineralisation, where the dehydration of collagen fibrils leads to contraction, putting the mineral phase under compression. While macroscopic stiffening of collagen upon drying is well-documented, the atomic-level structural rearrangements driving this phenomenon have remained elusive. By performing molecular dynamics simulations, we demonstrate that collagen contraction is not homogeneous but is driven by specific charged motifs. We identify a critical sequence-dependent rule for contraction: oppositely charged side chains must be separated by at least four residues to drive backbone contraction. While salt bridges can form between side chains at a distance less than four residues without perturbing the helix, those at greater distances cannot form without rupturing backbone hydrogen bonds. Consequently, dehydration forces these distant charges together, breaking local backbone structure and driving collagen contraction. These findings imply that collagen sequences are evolutionarily tuned to actively control tissue mechanics and redefines collagen as an active mechanical element rather than a passive scaffold. Furthermore, this framework provides a molecular basis for understanding mechanical failure associated with pathologies and ageing, while simultaneously opening avenues for designing bio-inspired materials with tunable pre-stress and fracture resistance.
Open AccessThe Molecular Origin of Water-Mediated Collagen Contraction
The mechanical toughness of bone and teeth relies on residual stresses generated during mineralisation, where the dehydration of collagen fibrils leads to contraction, putting the mineral phase under compression. While macroscopic stiffening of collagen upon drying is well-documented, the atomic-level structural rearrangements driving this phenomenon have remained elusive. By performing molecular dynamics simulations, we demonstrate that collagen contraction is not homogeneous but is driven by specific charged motifs. We identify a critical sequence-dependent rule for contraction: oppositely charged side chains must be separated by at least four residues to drive backbone contraction. While salt bridges can form between side chains at a distance less than four residues without perturbing the helix, those at greater distances cannot form without rupturing backbone hydrogen bonds. Consequently, dehydration forces these distant charges together, breaking local backbone structure and driving collagen contraction. These findings imply that collagen sequences are evolutionarily tuned to actively control tissue mechanics and redefines collagen as an active mechanical element rather than a passive scaffold. Furthermore, this framework provides a molecular basis for understanding mechanical failure associated with pathologies and ageing, while simultaneously opening avenues for designing bio-inspired materials with tunable pre-stress and fracture resistance.
- Open Access
- 4 March 2026
- Published by Elsevier in SSRN Electronic Journal
A Computationally Efficient Fibril-Scale Finite Element Model Bridges Molecular Mechanisms and Collagen Fibril Nonlinearity and Failure
Collagen fibrils exhibit nonlinear tensile behavior governed by tropocollagen molecule (TCM) stretching, intermolecular sliding, and cross-link–mediated load transfer. As cross-link accumulation is a hallmark of aging, diabetes, and several pathologies, resolving how cross-link chemistry, density, and network organization regulate fibril mechanics is central to explaining—and ultimately predicting—changes in tissue stiffness, strength, and failure. However, attributing the nonlinear tensile response to specific cross-link features remains difficult to isolate experimentally and computationally. Here we present a fibril-scale finite element (FE) model for large-deformation tension of a single type I collagen fibril that explicitly represents TCM backbones, stochastic cross-link networks, and friction-mediated intermolecular interactions. The model reproduces the nonlinear stress–strain response of human patellar tendon fibrils and predicts tangent moduli and strength in close agreement with experiment. Its computational efficiency enables length-converged ensemble simulations across cross-link realizations. Parametric studies identify cross-links as a key determinant of fibril mechanics: increasing cross-link density elevates low- and high-strain tangent moduli and ultimate tensile strength; enzymatic maturation is most impactful when cross-links are sparse and with intermediate density, whereas non-enzymatic cross-links trigger earlier rupture and damage accumulation, consistent with increased brittleness.
- 4 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Computationally Efficient Fibril-Scale Finite Element Model Bridges Molecular Mechanisms and Collagen Fibril Nonlinearity and Failure
Collagen fibrils exhibit nonlinear tensile behavior governed by tropocollagen molecule (TCM) stretching, intermolecular sliding, and cross-link–mediated load transfer. As cross-link accumulation is a hallmark of aging, diabetes, and several pathologies, resolving how cross-link chemistry, density, and network organization regulate fibril mechanics is central to explaining—and ultimately predicting—changes in tissue stiffness, strength, and failure. However, attributing the nonlinear tensile response to specific cross-link features remains difficult to isolate experimentally and computationally. Here we present a fibril-scale finite element (FE) model for large-deformation tension of a single type I collagen fibril that explicitly represents TCM backbones, stochastic cross-link networks, and friction-mediated intermolecular interactions. The model reproduces the nonlinear stress–strain response of human patellar tendon fibrils and predicts tangent moduli and strength in close agreement with experiment. Its computational efficiency enables length-converged ensemble simulations across cross-link realizations. Parametric studies identify cross-links as a key determinant of fibril mechanics: increasing cross-link density elevates low- and high-strain tangent moduli and ultimate tensile strength; enzymatic maturation is most impactful when cross-links are sparse and with intermediate density, whereas non-enzymatic cross-links trigger earlier rupture and damage accumulation, consistent with increased brittleness.
- Open Access
- 24 February 2026
- Published by Wiley in Surface and Interface Analysis
- Vol. 58 (6) , 369-374
Exploratory XPS Evidence for Ca–N Environments at the Organic–Mineral Interface in Bone
Bone derives its remarkable mechanical properties from the nanoscale relationship between its organic matrix and mineral components. While interfacial interactions are known to affect bone mechanics, direct evidence of chemical bonding at this interface has been lacking. This exploratory study uses X‐ray photoelectron spectroscopy (XPS) to generate hypotheses about potential chemical bonding between the organic matrix and mineral components in human bone. Femoral tissue samples from five cadaveric donors with varying bone mineral density (BMD) were analysed. Core‐level electronic states of nitrogen and calcium were examined to explore potential chemical bonding signatures. XPS analysis revealed signatures consistent with calcium–nitrogen (Ca–N) interactions in all samples, with a 2.4‐fold higher frequency in normal bone compared to osteoporotic bone. Normal bone exhibited a component‐derived Ca–N:N–Ca ratio of 17:8 ± 0.75, while osteoporotic bone showed 1:1 ± 0.06. The N–Ca interaction showed binding energies of 398.4–398.9 eV, while Ca–N signatures in Ca 2p 3/2 appeared at 346.9–347.0 eV. These preliminary XPS‐based observations are consistent with potential chemical bonding between the organic matrix and mineral components. We propose this interaction may occur between Ca 2+ in extrafibrillar mineral and an iminic nitrogen moiety in the organic matrix between mineralized fibrils. The reduction of these signatures in osteoporotic bone suggests they may contribute to bone strength, though the causal relationship remains to be established and further complementary techniques are needed for confirmation.
- 24 February 2026
- Published by Wiley in Surface and Interface Analysis
- Vol. 58 (6) , 369-374
Open AccessExploratory XPS Evidence for Ca–N Environments at the Organic–Mineral Interface in Bone
Bone derives its remarkable mechanical properties from the nanoscale relationship between its organic matrix and mineral components. While interfacial interactions are known to affect bone mechanics, direct evidence of chemical bonding at this interface has been lacking. This exploratory study uses X‐ray photoelectron spectroscopy (XPS) to generate hypotheses about potential chemical bonding between the organic matrix and mineral components in human bone. Femoral tissue samples from five cadaveric donors with varying bone mineral density (BMD) were analysed. Core‐level electronic states of nitrogen and calcium were examined to explore potential chemical bonding signatures. XPS analysis revealed signatures consistent with calcium–nitrogen (Ca–N) interactions in all samples, with a 2.4‐fold higher frequency in normal bone compared to osteoporotic bone. Normal bone exhibited a component‐derived Ca–N:N–Ca ratio of 17:8 ± 0.75, while osteoporotic bone showed 1:1 ± 0.06. The N–Ca interaction showed binding energies of 398.4–398.9 eV, while Ca–N signatures in Ca 2p 3/2 appeared at 346.9–347.0 eV. These preliminary XPS‐based observations are consistent with potential chemical bonding between the organic matrix and mineral components. We propose this interaction may occur between Ca 2+ in extrafibrillar mineral and an iminic nitrogen moiety in the organic matrix between mineralized fibrils. The reduction of these signatures in osteoporotic bone suggests they may contribute to bone strength, though the causal relationship remains to be established and further complementary techniques are needed for confirmation.
- Open Access
- 1 January 2026
- Published by Wiley in Advances in Orthopedics
- Vol. 2026 (1)
The Relationship Between Radiographic Metrics and Mechanical Properties of the Proximal Femur
Background: Bone mechanical properties, including strength and stiffness, influence intraoperative fracture risk and implant stability in hip arthroplasty. Surgeons frequently utilize radiographic metrics to evaluate bone quality and inform surgical strategies. This study investigates the correlation between radiographic bone metrics and the mechanical properties of the femoral neck. Methods: Femoral neck cortical bone samples from 23 patients undergoing elective hip arthroplasty were subjected to mechanical compression testing to measure elastic modulus and ultimate strength. Density was also measured. Radiographic metrics, including cortical thickness index, canal flare index, canal–bone ratio and canal–calcar ratio, were determined from preoperative radiographs. The correlations between these metrics and bone mechanical properties were analysed using linear regression, with intra‐ and interobserver reliability assessed. Results: Analysis included 19 of the 23 participants. Whilst cortical thickness index measurements demonstrated a weak positive correlation with bone density ( R 2 = 0.291; p = 0.013) and ultimate strength ( R 2 = 0.279; p = 0.015), canal–bone ratio showed a weak negative correlation with both factors ( R 2 = 0.291; p = 0.013 and R 2 = 0.279; p = 0.015, respectively). Both cortical thickness index and canal–bone ratio demonstrated excellent inter‐ and intraobserver reliability. Neither canal flare index nor canal–calcar ratio correlated with any mechanical properties, and none of the radiographic metrics correlated with elastic modulus. Conclusions: Cortical thickness index and canal–bone ratio correlate weakly with bone strength and density but not with elastic modulus. Given their limited utility, radiographs should be used with caution in surgical decision‐making regarding impaction force and implant fixation strategy.
- 1 January 2026
- Published by Wiley in Advances in Orthopedics
- Vol. 2026 (1)
Open AccessThe Relationship Between Radiographic Metrics and Mechanical Properties of the Proximal Femur
Background: Bone mechanical properties, including strength and stiffness, influence intraoperative fracture risk and implant stability in hip arthroplasty. Surgeons frequently utilize radiographic metrics to evaluate bone quality and inform surgical strategies. This study investigates the correlation between radiographic bone metrics and the mechanical properties of the femoral neck. Methods: Femoral neck cortical bone samples from 23 patients undergoing elective hip arthroplasty were subjected to mechanical compression testing to measure elastic modulus and ultimate strength. Density was also measured. Radiographic metrics, including cortical thickness index, canal flare index, canal–bone ratio and canal–calcar ratio, were determined from preoperative radiographs. The correlations between these metrics and bone mechanical properties were analysed using linear regression, with intra‐ and interobserver reliability assessed. Results: Analysis included 19 of the 23 participants. Whilst cortical thickness index measurements demonstrated a weak positive correlation with bone density ( R 2 = 0.291; p = 0.013) and ultimate strength ( R 2 = 0.279; p = 0.015), canal–bone ratio showed a weak negative correlation with both factors ( R 2 = 0.291; p = 0.013 and R 2 = 0.279; p = 0.015, respectively). Both cortical thickness index and canal–bone ratio demonstrated excellent inter‐ and intraobserver reliability. Neither canal flare index nor canal–calcar ratio correlated with any mechanical properties, and none of the radiographic metrics correlated with elastic modulus. Conclusions: Cortical thickness index and canal–bone ratio correlate weakly with bone strength and density but not with elastic modulus. Given their limited utility, radiographs should be used with caution in surgical decision‐making regarding impaction force and implant fixation strategy.
- Open Access
Leveraging topological data analysis to estimate bone strength from micro-CT as a surrogate for advanced imaging
Accurate bone strength prediction is essential for assessing fracture risk, particularly in aging populations and individuals with osteoporosis. Bone imaging has evolved from X-rays and DXA to clinical computed tomography (CT), and now to advanced modalities such as high-resolution peripheral quantitative CT and synchrotron radiation CT, which offer unprecedented resolution of bone microarchitecture. However, analytical methods have not kept pace with these imaging advances. This study applied topological data analysis (TDA) to extract biomechanically relevant features from high-resolution bone images, offering a new framework for bone strength prediction. We extracted topological features, specifically those derived from persistent homology, and combined them with standard bone morphometric descriptors to train machine learning models for apparent strength prediction. Models based solely on topological features outperformed those using traditional morphometrics, highlighting TDA's ability to capture biomechanically relevant structure. In particular, internal voids, often dismissed as imaging noise, proved to be the most predictive. While limited by dataset size and class imbalance, these results suggest that TDA offers a promising approach for advancing osteoporosis risk assessment.
Open AccessLeveraging topological data analysis to estimate bone strength from micro-CT as a surrogate for advanced imaging
Accurate bone strength prediction is essential for assessing fracture risk, particularly in aging populations and individuals with osteoporosis. Bone imaging has evolved from X-rays and DXA to clinical computed tomography (CT), and now to advanced modalities such as high-resolution peripheral quantitative CT and synchrotron radiation CT, which offer unprecedented resolution of bone microarchitecture. However, analytical methods have not kept pace with these imaging advances. This study applied topological data analysis (TDA) to extract biomechanically relevant features from high-resolution bone images, offering a new framework for bone strength prediction. We extracted topological features, specifically those derived from persistent homology, and combined them with standard bone morphometric descriptors to train machine learning models for apparent strength prediction. Models based solely on topological features outperformed those using traditional morphometrics, highlighting TDA's ability to capture biomechanically relevant structure. In particular, internal voids, often dismissed as imaging noise, proved to be the most predictive. While limited by dataset size and class imbalance, these results suggest that TDA offers a promising approach for advancing osteoporosis risk assessment.
- Open Access
Prevalence and Predictors of Silent Vertebral Compression Fractures: A Cross-Sectional Population-Based Study Using UK Biobank Imaging Data
Objectives: To estimate the prevalence of silent vertebral compression fractures (VCF) in an asymptomatic population and to assess the demographic and clinical predictors using data from the UK Biobank. Design: A cross-sectional study using artificial intelligence-assisted six-point morphometry of dual-energy x-ray absorptiometry spine images. Setting: UK Biobank imaging study at Stockport clinical research facility. Participants: 2,446 asymptomatic volunteers aged 40 to 79 years with no history of spinal trauma or vertebral fracture. Main outcome measures: VCFs were defined as greater than or equal to 20 percent height loss, measured by artificial intelligence, with manual correction of annotations and confirmation by a musculoskeletal radiologist. Association with age, sex, bone mineral density, body mass index, and back pain were analyzed. Results: Of 2,446 participants, 763 (31.1 percent) had at least one vertebra with greater than 20 percent height loss. Fracture prevalence increased with age: 26.8 percent (37 of 138) in those aged 40-49 years, 26.1 percent (196 of 752) at 50-59 years, 33.0 percent (380 of 1,153) at 60-69 years, and 37.2 percent (150 of 403) at 70-79 years. Excluding mild deformities, 18 percent of those aged 40-49 years had moderate or severe fractures (greater than 25 percent height loss). Fractures were 11.5 percent more common in men than in women. Age was a significant predictor, but bone mineral density (BMD) and body mass index (BMI) were not. Predictive models showed limited performance (sensitivity 44.4 percent, specificity 68.2 percent). Interobserver agreement was substantial (Fleiss kappa = 0.74). Conclusions: Silent VCFs are frequent by midlife, including among younger adults with normal bone density. Men are affected more often than women, and conventional risk factors inadequately identify those at risk. Earlier detection through opportunistic or population imaging may enable timely intervention and inform future screening and fracture-prevention strategies.
Open AccessPrevalence and Predictors of Silent Vertebral Compression Fractures: A Cross-Sectional Population-Based Study Using UK Biobank Imaging Data
Objectives: To estimate the prevalence of silent vertebral compression fractures (VCF) in an asymptomatic population and to assess the demographic and clinical predictors using data from the UK Biobank. Design: A cross-sectional study using artificial intelligence-assisted six-point morphometry of dual-energy x-ray absorptiometry spine images. Setting: UK Biobank imaging study at Stockport clinical research facility. Participants: 2,446 asymptomatic volunteers aged 40 to 79 years with no history of spinal trauma or vertebral fracture. Main outcome measures: VCFs were defined as greater than or equal to 20 percent height loss, measured by artificial intelligence, with manual correction of annotations and confirmation by a musculoskeletal radiologist. Association with age, sex, bone mineral density, body mass index, and back pain were analyzed. Results: Of 2,446 participants, 763 (31.1 percent) had at least one vertebra with greater than 20 percent height loss. Fracture prevalence increased with age: 26.8 percent (37 of 138) in those aged 40-49 years, 26.1 percent (196 of 752) at 50-59 years, 33.0 percent (380 of 1,153) at 60-69 years, and 37.2 percent (150 of 403) at 70-79 years. Excluding mild deformities, 18 percent of those aged 40-49 years had moderate or severe fractures (greater than 25 percent height loss). Fractures were 11.5 percent more common in men than in women. Age was a significant predictor, but bone mineral density (BMD) and body mass index (BMI) were not. Predictive models showed limited performance (sensitivity 44.4 percent, specificity 68.2 percent). Interobserver agreement was substantial (Fleiss kappa = 0.74). Conclusions: Silent VCFs are frequent by midlife, including among younger adults with normal bone density. Men are affected more often than women, and conventional risk factors inadequately identify those at risk. Earlier detection through opportunistic or population imaging may enable timely intervention and inform future screening and fracture-prevention strategies.
- 1 August 2025
- Published by Avestia Publishing
Traffic-Derived Metal Bioaccumulation in Bone Tissue as a Driver of Osteoporosis
- 1 August 2025
- Published by Avestia Publishing
Traffic-Derived Metal Bioaccumulation in Bone Tissue as a Driver of Osteoporosis
- Open Access
Balance in Dance: A Scoping Review
Balance is a fundamental component of dance performance, yet its definition and assessment in dance remain challenging. This scoping review aims to bridge the gap between existing balance research and practical applications by critically evaluating current measurement technologies, examining factors influencing balance performance, and exploring the mechanisms through which these factors interact with dance execution. A comprehensive search of PubMed and Embase databases identified 69 relevant papers published since 1999, focusing exclusively on studies on people who regularly engage in dance. Our analysis revealed limitations in standard balance assessment tools, with most current tests failing to sufficiently challenge skilled dancers. Recent developments in dance-specific assessments, particularly modifications of the Star Excursion Balance Test, show promise, though their effectiveness varies across different dance styles and skill levels. Force plate analysis combined with skill-based tests provide a more comprehensive assessment of capabilities, especially with respect to motor skill acquisition and injury recovery. Literature analysis identified several factors affecting balance in dance: aerobic capacity, muscle fatigue, lower extremity strength, and previous injuries. Additionally, technical considerations, such as pointe shoe degradation, significantly impact balance strategies and injury risk. Although strength training shows positive effects on balance and dance-specific skills, the influence of cognitive load, nutrition, and long-term training adaptation remains unclear. Future research should prioritize developing and validating dance-specific balance measures while investigating targeted interventions for different dance populations. This synthesis emphasizes the critical need for dance-specific approaches to balance assessment and training, with direct applications for both research methodology and dance education practices.
Open AccessBalance in Dance: A Scoping Review
Balance is a fundamental component of dance performance, yet its definition and assessment in dance remain challenging. This scoping review aims to bridge the gap between existing balance research and practical applications by critically evaluating current measurement technologies, examining factors influencing balance performance, and exploring the mechanisms through which these factors interact with dance execution. A comprehensive search of PubMed and Embase databases identified 69 relevant papers published since 1999, focusing exclusively on studies on people who regularly engage in dance. Our analysis revealed limitations in standard balance assessment tools, with most current tests failing to sufficiently challenge skilled dancers. Recent developments in dance-specific assessments, particularly modifications of the Star Excursion Balance Test, show promise, though their effectiveness varies across different dance styles and skill levels. Force plate analysis combined with skill-based tests provide a more comprehensive assessment of capabilities, especially with respect to motor skill acquisition and injury recovery. Literature analysis identified several factors affecting balance in dance: aerobic capacity, muscle fatigue, lower extremity strength, and previous injuries. Additionally, technical considerations, such as pointe shoe degradation, significantly impact balance strategies and injury risk. Although strength training shows positive effects on balance and dance-specific skills, the influence of cognitive load, nutrition, and long-term training adaptation remains unclear. Future research should prioritize developing and validating dance-specific balance measures while investigating targeted interventions for different dance populations. This synthesis emphasizes the critical need for dance-specific approaches to balance assessment and training, with direct applications for both research methodology and dance education practices.
- 19 February 2025
- Published by SAGE Publications in Journal of Dance Medicine & Science
- Vol. 29 (4) , 200-210
Pilot Study of Bone Turnover Biomarkers, Diet, and Exercise in Elite Female Ballet Dancers
Introduction: Elite ballet is one of the most demanding physical activities for the skeleton, making dancers susceptible to bone stress injuries. This pilot study compared bone remodeling in professional female ballet dancers from the Royal Ballet Company with controls from Imperial College London. Methods: The study included dancers (n = 5, median age 29 ± 16 years) and controls (n = 6, median age 24 ± 8.5 years). The main outcome measure was bone turnover, assessed by measuring the ratio of resorption (NTX) and formation (P1NP) markers in urine and serum. Estrogen metabolism was evaluated through 2OH/16OH metabolite ratios. Both markers were measured using ELISA kits. Diet was tracked using 72-hour diaries, and weekly exercise hours were recorded through 2-week diaries and cross referenced with training logs. Results: Results showed significantly higher bone resorption to formation ratio (NTX/P1NP) in dancers versus controls ( P < .050), and elevated estrogen metabolite ratios (2OH/16OH) ( P < .010). These findings occurred despite similar dietary profiles between groups including fat ( P = .874) carbohydrate ( P = .501) and protein ( P = .099). Dancers showed significantly higher weekly exercise hours (46.50 ± 38.75 vs 14.75 ± 11.75 hours/week, P < .001) and lower BMI (18.36 ± 1.35 vs 20.77 ± 3.66, P = .020). Conclusions: The pilot data suggest elite ballet dancers may exhibit an imbalance in bone remodeling with high resorption and low formation relative to controls. This imbalance in bone turnover markers could serve as a screening tool for identifying dancers at increased risk of bone stress injuries. The NTX/P1NP ratio could potentially offer a low-cost, non-invasive approach to identify at-risk dancers early and implement preventative measures. Further research and longitudinal trials are needed to test whether these markers can predict bone stress injury risk.
- 19 February 2025
- Published by SAGE Publications in Journal of Dance Medicine & Science
- Vol. 29 (4) , 200-210
Pilot Study of Bone Turnover Biomarkers, Diet, and Exercise in Elite Female Ballet Dancers
Introduction: Elite ballet is one of the most demanding physical activities for the skeleton, making dancers susceptible to bone stress injuries. This pilot study compared bone remodeling in professional female ballet dancers from the Royal Ballet Company with controls from Imperial College London. Methods: The study included dancers (n = 5, median age 29 ± 16 years) and controls (n = 6, median age 24 ± 8.5 years). The main outcome measure was bone turnover, assessed by measuring the ratio of resorption (NTX) and formation (P1NP) markers in urine and serum. Estrogen metabolism was evaluated through 2OH/16OH metabolite ratios. Both markers were measured using ELISA kits. Diet was tracked using 72-hour diaries, and weekly exercise hours were recorded through 2-week diaries and cross referenced with training logs. Results: Results showed significantly higher bone resorption to formation ratio (NTX/P1NP) in dancers versus controls ( P < .050), and elevated estrogen metabolite ratios (2OH/16OH) ( P < .010). These findings occurred despite similar dietary profiles between groups including fat ( P = .874) carbohydrate ( P = .501) and protein ( P = .099). Dancers showed significantly higher weekly exercise hours (46.50 ± 38.75 vs 14.75 ± 11.75 hours/week, P < .001) and lower BMI (18.36 ± 1.35 vs 20.77 ± 3.66, P = .020). Conclusions: The pilot data suggest elite ballet dancers may exhibit an imbalance in bone remodeling with high resorption and low formation relative to controls. This imbalance in bone turnover markers could serve as a screening tool for identifying dancers at increased risk of bone stress injuries. The NTX/P1NP ratio could potentially offer a low-cost, non-invasive approach to identify at-risk dancers early and implement preventative measures. Further research and longitudinal trials are needed to test whether these markers can predict bone stress injury risk.