MHMarkus Hof

Markus Hof

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Markus Hof has a total of 59 co-authors. Here are the top co-authors by number of shared publications:

  • Werner Zechner

    Division of Oral Surgery, Dental University Clinic Vienna, Medical University of Vienna, Vienna, Austria

    6 shared publications
  • Georg Watzek

    Former Head of the Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Medical University of Vienna, Austria; Academy for Oral Implantology, Vienna, Austria

    5 shared publications
  • Bernhard Pommer

    Academy for Oral Implantology, Vienna, Austria

    4 shared publications
  • Bernhard Pommer

    Department of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna Medical University, Vienna, Austria

    3 shared publications
  • Bernhard Pommer

    Academy for Oral Implantology Vienna Austria

    3 shared publications
  • Gabor Tepper

    Bernhard Gottlieb School of Dentistry, Vienna Medical University, Sensengasse 2a, 1090 Vienna, Austria

    3 shared publications

Latest Publications

  • Evaluation of implant esthetics using eight objective indices—Comparative analysis of reliability and validity

    by Markus Hof, Nabeel Umar, Nikolaus Budas, Rudolf Seemann, Bernhard Pommer, Werner Zechner

    Objectives: The aim of the present study was to give a detailed analysis on eight proposed implant esthetic indices including a total of 48 parameters with respect to validity and reproducibility as well as its correlation to patients’ perception of esthetics.Material and methods: Standardized intraoral photographs of 189 patients with 189 implant‐supported crowns and adjacent peri‐implant soft tissue in the esthetic zone (central and lateral incisors, canine, first premolar) served as basis for this evaluation. Eight indices (Papilla Index [PI], Pink Esthetic Score [PES], Implant Crown Aesthetic Index [ICAI], Pink and White Esthetic Score [PES/WES], Complex Esthetic Index [CEI], Implant Aesthetic Score [IAS], Subjective Esthetic Score [SES], and Rompen Index) with a total of 48 parameters were selected. Esthetic evaluation was performed twice by five examiners with an interval of 4 weeks between the evaluations.Results: A total of 1,890 evaluations including eight esthetic indices served as basis for the statistical analysis. Among the overall main scores tested for inter‐rater reliability, the highest values were computed for CEI, PES, PI, and IAS scores. By contrast, SES and Rompen showed the worst inter‐rater reliability, respectively. The highest level of intra‐rater reproducibility was noted for PI, PES, and CEI. The lowest level of intra‐rater reproducibility showed Rompen, SES, and ICA. The Papilla Index demonstrated the highest level of inter‐rater reliability. The remainder of the single variables (n = 46) did not reach the level of 0.6. The single variables PI mesial, PI distal as well as CEI P4 showed the highest with statistical significance higher than 0.8. The lowest agreement was observed among the variables ICA3, WES5, and IASm2. In general, VAS did not show any good correlation to the esthetic indices proposed so far. The influence of esthetic parameters on subjective patient satisfaction was generally low.Conclusion: In conclusion, significant differences regarding reliability and validity could be observed in the present comparison of eight esthetic indices. Objective evaluation of the esthetic outcome of implant therapy inherently fails to reflect subjective patient opinion, however, requires consistency of results to enable between‐study comparison and meta‐analysis.


  • Open Access

    Guided bone regeneration using collagen membranes simultaneous to implant placement at compromised sites leads to reproducible results and high success rates

    by Bastian Wessing, Istvan Urban, Eduardo Montero, Werner Zechner, Markus Hof, Javier Alandez, Nuria Alandez, Giovanni Polizzi, Silvio Meloni, Mariano Sanz

    An implant-supported prosthesis can restore masticatory function to patients with missing teeth. A prerequisite for success is to position the implant inserted within sufficient bone to be stably osseointegrated, whilst also allowing the restoration to meet functional and esthetic needs. Unfortunately, prosthesis-driven implant sites are not always characterized by adequate bone dimensions. Furthermore, following tooth extraction, severe bone resorption often occurs. Though an array of surgical techniques are available for bone augmentation, guided bone regeneration (GBR) is one that can produce both functional and esthetic results reproducibly with high success rates, whether performed prior to or simultaneous with implant placement. Given the relevance of barrier membrane material and its individual properties to the success of GBR and, consequently, implant-supported restorations, we compared the clinical performance of a new resorbable non-crosslinked collagen membrane, creos xenoprotect (CXP), with a reference membrane Bio-Gide (BG), for GBR at dehisced implant sites. Results from a prospective, randomized clinical trial (NCT02373787) on 49 patients receiving simultaneous GBR and implant insertion demonstrated that both collagen membranes result in safe bone augmentation of dehiscence defects. Implant survival rate at reentry surgery, 6 months after implant insertion, was 100%. The new CXP membrane was statistically non-inferior to the reference BG membrane with respect to mean difference in bone defect height between implant insertion and reentry surgery (p <0.001). Moreover, there was no difference in patient pain or quality of life between the two treatment arms. However, there were trends in improved outcomes, namely higher bone gain and lower membrane exposure rates, when CXP was used compared with BG, though not statistically significant. Together, the study confirms that, even using a simultaneous surgical approach, the CXP collagen membrane supports bone regeneration at dehisced implant sites with few complications. This demonstrates that new barrier membrane materials with improved properties, such as CXP, can provide clinical benefits to patients.

  • Does osteoporosis influence the marginal peri‐implant bone level in female patients? A cross‐sectional study in a matched collective

    by Florian Wagner, Krisztian Schuder, Markus Hof, Simone Heuberer, Rudolf Seemann, Gabriella Dvorak

    Background/purpose: Osteoporosis, being a homeostatic imbalance, affects the remodeling of bone. Whether this catabolic bone disease influences peri‐implant marginal bone remodeling remains unknown so far. The purpose of this study was to evaluate the influence of osteoporosis on peri‐implant marginal bone loss (MBL) in postmenopausal women.Materials and methods: In a matched collective, radiographic peri‐implant bone level (at baseline and at follow‐up examinations) was compared in healthy and osteoporotic women. General health and behavioral history of the patients were recorded using a printed questionnaire.Results: A best fit matching procedure generated a sample of 48 women with a total of 204 implants matched at patient and implant level that was further statistically analyzed. The mean mesial MBL—statistically corrected to report the first year—was −0.6 ± 1.2 mm (range: −5.1 to 2.2) in the healthy control group and −1.1 ± 1.3 mm (range: −5.3 to 2.2) in the osteoporotic group. Similarly, the mean distal MBL was −0.5 ± 1.3 mm (range: −5.1 to 4.8) in the healthy control group and −1.2 ± 1.3 mm (range: −4.7 to 1.6) in the osteoporotic group, respectively. The base linear regression models including solely osteoporosis and time without any other confounders revealed a significant influence of osteoporosis and time since implant placement on the MBL at the mesial and the distal implant aspect. The significance of osteoporosis on bone loss did not change incorporating the confounders: bone level at implantation, smoking, jaw, location, surface, concrement, plaque, augmentation, edentulism in opposing and implant jaw, bisphosphonates, vitamin D, fixed versus removable prosthetics, connection type.Conclusions: There is no contraindication to place dental implants in osteoporotic patients. This study implicates to respect the bone level at implant placement and not to place the implant below bone level if possible.


  • Open Access

    A multicenter randomized controlled clinical trial using a new resorbable non‐cross‐linked collagen membrane for guided bone regeneration at dehisced single implant sites: interim results of a bone augmentation procedure

    by Bastian Wessing, Istvan Urban, Eduardo Montero, Werner Zechner, Markus Hof, Javier Alández Chamorro, Nuria Alández Martin, Giovanni Polizzi, Silvio Meloni, Mariano Sanz

    Objective: To compare clinical performance of a new resorbable non‐cross‐linked collagen membrane, creos xenoprotect (CXP), with a reference membrane (BG) for guided bone regeneration at dehisced implant sites.Materials and methods: This randomized controlled clinical trial enrolled patients with expected dehiscence defects following implant placement to restore single teeth in the maxillary and mandibular esthetic zone and premolar area. Implants were placed using a two‐stage surgical protocol with delayed loading. Bone augmentation material placed at the implant surface was immobilized with CXP or BG membrane. Soft tissue health was followed during the healing period, and the defect size was measured at reentry and 6 months after implant placement.Results: Of the 49 included patients, 24 were treated with CXP and 25 with BG. Patient characteristics did not differ between the two arms. In the CXP arm, the defect height at implant insertion was (mean ± SD) 5.1 ± 2.1 mm (n = 24) and reduced at reentry by 81% to 1.0 ± 1.3 mm (n = 23). In the BG arm, the defect height at implant insertion was 4.9 ± 1.9 mm (n = 25) and reduced at reentry by 62% to 1.7 ± 2.1 mm (n = 24). Assuming a margin of non‐inferiority of 1 mm, CXP was non‐inferior to BG. Membrane exposure rate was highest at week 3 in both arms, reaching 16.7% for BG and 8.7% for CXP.Conclusions: The new resorbable non‐cross‐linked collagen membrane facilitates bone gain to support implant placement in expected dehiscence defects. The observed trend toward higher mean bone gain and lower exposure rate with CXP compared to BG should be further investigated.


  • Top Cited Papers

    Risk Factors of Membrane Perforation and Postoperative Complications in Sinus Floor Elevation Surgery: Review of 407 Augmentation Procedures

    by Linda Schwarz, Vanessa Schiebel, Markus Hof, Christian Ulm, Georg Watzek, Bernhard Pommer


  • Effect of personality traits on the oral health-related quality of life in patients with oral mucosal disease

    by Andrea Fädler, Thomas Hartmann, Thomas Bernhart, Babak Monshi, Klemens Rappersberger, Markus Hof, Gabriella Dvorak

    The aim of this study was to assess the relationship between oral health-related quality of life, the nature of mucosal disease, and personality traits. One hundred forty-nine patients seeking care for oral mucosal disease were recruited in this cross-sectional study conducted at the University Clinic of Dentistry in Vienna from June to December 2013. All participants agreed in answering two questionnaires: the Oral Health Impact Profile German version (OHIP-G), which assessed the perceived limitations of oral health-related quality of life and the Neuroticism Extraversion Openness Five-Factor Inventory (NEO-FFI), which evaluated five personality domains. A multiple linear regression was applied to examine the potential influence on OHIP scores. Bullous/erosive mucosal diseases and oral lichen planus patients (n = 73, 49 % of total) reported the highest impact on oral health-related quality of life (OHIP total score 49.3 ± 35.7, p = 0.02). A highly significant influence of neuroticism, as a personality trait, was observed on oral health-related quality of life (p = 0.001). Women had significantly more restrictions (OHIP score 45.3 ± 32.2) compared to men (32.6 ± 30.1, p = 0.009). Psychosocial factors such as personality traits, especially neuroticism, are significantly associated with quality of life ratings in patients with mucosal disease. Since mucosal diseases impact patient’s daily living and quality of life while affected by their psychological profiles, this should be considered when formulating a therapeutic approach.


  • Does Timing of Implant Placement Affect Implant Therapy Outcome in the Aesthetic Zone? A Clinical, Radiological, Aesthetic, and Patient‐Based Evaluation

    by Markus Hof, Bernhard Pommer, Harald Ambros, Philip Jesch, Susanne Vogl, Werner Zechner

    Purpose: To compare five different implant treatment protocols in the anterior maxilla, including immediate, early, and delayed implant placement, as well as implant placement in conjunction with simultaneous guided bone regeneration and implant placement 3 months following horizontal autologous bone block grafting.Material and Methods: Aesthetic indices used included the Pink Esthetic Score (PES), Papilla Index (PI), Subjective Esthetic Score (SES), and White Esthetic Score (WES). Subjective evaluation of implant aesthetics was performed using a visual analogue scale (VAS). The VAS consisted of a 10 cm–long line representing the degree of discontent (0%) or satisfaction (100%).Results: A total of 153 implants in 153 patients (80 women, 73 men) were evaluated after a mean follow‐up of 4.5 ± 2.9 years. Mean peri‐implant bone loss was 1.6 ± 0.9 mm and not affected by treatment protocol, time after implant placement, or crown length. Papilla presence, by contrast, differed significantly between the protocols: Papilla formation was more pronounced following delayed and immediate implant placement. No statistical significance was found among treatment modalities with regard to PES, SES, or WES. Longer crowns were associated with lower PES and PI ratings and correlated with greater midfacial recession. SES was also influenced by time after implant placement and keratinized mucosa. Patient satisfaction differed significantly among treatment protocols, favoring immediate implant placement. Agreement between objective and subjective aesthetic ratings was low.Conclusion: The present study suggests that comparable clinical, radiological, and aesthetic results can be achieved with all treatment protocols. Gingival recession, however, seems to occur in the long term irrespective of the technique used.


  • Open Access

    Meta-Analysis of Oral Implant Fracture Incidence and Related Determinants

    by Bernhard Pommer, Lavinia Bucur, Konstantin Zauza, Gabor Tepper, Markus Hof, Georg Watzek

    Dental implant fracture is a rare biomechanical complication, however, one of the most serious and frustating ones as it is generally associated with implant and prosthesis failure as well as the surgical hazards of explantation and reimplantation. To gain insights into implant fracture rates and the impact of patient-, surgery-, and prosthetic-related factors, systematic review and meta-analysis of the English literature were performed. Electronic and hand searches yielded 69 relevant publications reporting on 827 fractures out of 44521 implants investigated. The overall incidence of implant fractures was 1.6%. Mean patient age at the time of implant fracture was 54 ± 11 years, and 70% occurred in males. The vast majority (85%) occurred in posterior regions of the mouth (premolar or molar positions). No tendency of increased fracture rates could be noted for short implant lengths or narrow implant diameters. Implant fractures occurred after 4.1 ± 3.5 years of loading, on average, in most cases (88%) supporting fixed restorations; however, only 56% were preceded by screw loosening. Although further investigations are needed to fully explore the characteristics and causes of this rare complication, it can be concluded that no more than 2.8% of implants fracture is within a mean loading period of 8.3 years.


  • Immediate Occlusal versus Non‐Occlusal Loading of Implants: A Randomized Clinical Pilot Study

    by Susanne Vogl, Marlene Stopper, Markus Hof, Walther A. Wegscheider, Martin Lorenzoni

    Background: Immediate occlusal and non‐occlusal loading protocols have been discussed and, despite varying success rates, are considered viable in selected cases. Preoperative implant planning and intraoperative transfer are essential to the success of implant‐supported reconstructions in partially or completely edentulous jaws.Purpose: This study was performed to compare clinical outcomes of immediate occlusal versus non‐occlusal loading of posterior implants.Materials and Methods: Of 19 patients with 52 screw‐type implants replacing mandibular molars or premolars, nine patients with 21 implants were randomized to a study group that received immediate restorations with occlusal loading, whereas 10 patients with 31 implants were randomized to a control group that received provisional restorations without occlusal loading. Occlusal loading was defined as full loading in maximum intercuspidation. Single‐tooth or splinted multiunit restorations were incorporated by screw retention or cementation. Marginal bone defects (MBD), implant survival, and implant success were evaluated 12 months after insertion.Results: Both groups revealed similar MBD levels consistent with previous reports. No implants were lost (overall survival: 100%) or found to fail (overall success: 100%). No significant intergroup differences were noted for any of the evaluated parameters.Conclusions: Immediate restorations in partially edentulous mandibles demonstrated successful clinical and radiographic 12‐month results. Larger long‐term prospective studies are needed to confirm the final evidence and predictability of immediate functional loading as a standard treatment concept for partially edentulous jaws.