CACostas Arvanitis

Costas Arvanitis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Costas Arvanitis has a total of 105 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reconstruction of microbubble oscillation dynamics with frequency-domain backpropagation in optically inaccessible environments

    by Hohyun Lee, Reza Pakdaman Zangabad, Chulyong Kim, Victor Menezes, Juyoung Park, F. Levent Degertekin, Costas Arvanitis

  • Enhancing immune cell trafficking to brain tumors: Recent advances and therapeutic strategies

    by Zhuoqi Tong, Chulyong Kim, James L Ross, Costas Arvanitis

    For peripheral immune cells to be effective against brain tumors, multiple coordinated steps are required, including migration and homing to the local microenvironment—collectively referred to as immune cell trafficking—followed by survival, proliferation, and persistence, all while remaining functional. This review focuses on the often-overlooked first step, trafficking, which is critical for initiating subsequent processes and driving antitumor responses. We summarize the migration cascade of immune cells, including T cells and macrophages, across the blood-brain barrier (BBB) and how primary brain tumors as well as brain metastases alter the molecular pathways and interactions associated with the immune cell migration cascade across the BBB and their functional homing. Subsequently, we highlight recent developments in engineering biomolecular, cellular, and physical methods to modulate the tumor microenvironment and improve the functional trafficking of immune cells in brain tumors. Our analysis reveals novel combinations to potentiate antitumor responses via feedforward mechanisms and modular therapeutic strategies designed to improve the migration and accumulation of functional immune cells in brain tumors. A deeper understanding of immune cell trafficking, distribution, and homing through the application of preclinical and clinical imaging techniques along with the development of in vitro/ex vivo platforms should enable new and more potent immunotherapy strategies against primary brain malignancies and brain metastases as well as accelerate their translation to the clinic.


  • Open Access

    Data‐Driven Feedback Identifies Focused Ultrasound Exposure Regimens for Improved Nanotheranostic Targeting of the Brain

    by Hohyun Lee, Victor Menezes, Shiqin Zeng, Chulyong Kim, Cynthia M. Baseman, Jae Hyun Kim, Samhita Padmanabhan, Pranav Premdas, Naima Djeddar, Anton Bryksin, et al.

    The blood‐brain barrier (BBB) renders the delivery of nanomedicine in the brain ineffective and the detection of circulating disease‐related DNA from the brain unreliable. Here, we demonstrate that microbubble‐enhanced focused ultrasound (MB‐FUS) mediated BBB opening, supported by large‐data models predict sonication regimens for safe and effective BBB opening. Importantly, a closed‐loop MB‐FUS controller augmented by machine learning (ML‐CL) expands the treatment window, as compared to conventional controllers, by persistently and proactively maximizing the BBB permeability while preventing tissue damage. By successfully scaling up from mice to rats and from healthy to diseased brains (glioma), ML‐CL rendered the BBB permeable to large nanoparticles and markedly improved the release and detection of reporter gene DNA from tumors in blood. Together, our findings reveal the potential of data‐driven feedback to support the development of next‐generation AI‐powered ultrasound systems for safe, robust, and efficient nanotheranostic targeting and treatment of brain diseases.


  • Open Access

    Quantitative acoustic monitoring of ensembles of weakly nonlinear microbubble oscillations in optically inaccessible environments

    by Hohyun Lee, Reza Pakdaman Zangabad, Chulyong Kim, Victor Menezes, Juyoung Park, F. Levent Degertekin, Costas Arvanitis

    A growing class of ultrasound-mediated diagnostic and therapeutic technologies, including sonoporation and blood-brain barrier modulation, relies on microbubble contrast agents, where precise control of microbubble dynamics governs biological responses, efficiency, and safety. However, quantitative monitoring of microbubble oscillations in the stable, weakly nonlinear regime remains challenging, particularly in optically opaque and deep-tissue environments. Here, we introduce a linear acoustic wave propagation and superposition (LAWPS) framework that reconstructs microbubble radius-time dynamics directly from passively recorded acoustic emissions. By coupling Fourier-series representations of weakly nonlinear oscillations with linear monopole radiation theory, LAWPS extends classical monopole models to establish a reversible relationship between multi-frequency acoustic emissions and underlying radial bubble dynamics. Extending this framework to monodisperse microbubble ensembles, we derive optimal excitation and receive configurations and population-level correction factors that enable quantitative reconstruction of the ensemble-averaged microbubble dynamics. Using simultaneous optical and acoustic measurements, we demonstrate recovery of microbubble oscillations with ~5% relative error for oscillation amplitudes up to ~15% of equilibrium radius. Finally, we show that oscillations within the framework's operating regime (20% oscillation) generate sonoporation-relevant mechanical stress in vesicles as small as 10 micrometers (capillary number > 0.01), under physiologically relevant conditions. Together, this work establishes a quantitative framework for acoustic emission-based monitoring of weakly nonlinear microbubble oscillations in clinically relevant, optically inaccessible environments to enable improved control of emerging ultrasound diagnostic and therapeutic technologies.

  • Open Access

    A figure of merit for transcranial ultrasound transmission based on coupled elastic-thermal analysis

    by M Sait Kilinc, Costas Arvanitis, F Levent Degertekin

    Objective. To evaluate the efficiency of ultrasound transmission and its associated thermal effects on the skull, introducing a figure of merit (FOM) to assess the efficacy and safety of transcranial focused ultrasound (tFUS) at varying incidence angles and frequencies. Approach . A coupled elastic-thermal analysis was performed using a two-dimensional (2D) parallel solid plate skull model, validated through three-dimensional simulations. High-resolution micro-computed tomography (microCT) data from an ex vivo human skull sample was incorporated for realistic modeling. Simulations were conducted at frequencies of 0.8 MHz, 1 MHz, and 1.2 MHz to explore the impact of skull thickness, incidence angle, and absorption properties on ultrasound transmission and heating. The FOM was calculated for each scenario to provide an integrated measure of transmission efficiency and thermal safety. Experimental studies using the same ex vivo human skull validated the microCT-based simulation model. Main results . The FOM analysis demonstrated that at 0.8 MHz for an 8 mm thick skull, the FOM dropped by half for incidence angles above 15°, indicating reduced ultrasound transmission and heightened temperature rise at oblique angles. These findings suggest that dual-mode conversion at higher angles may not be suitable for tFUS applications, supporting the clinical preference for near-normal incidence. The validated 2D microCT model provides a reliable framework for studying the interplay between transmission and heating effects. Significance . This study provides an integrated framework for optimizing tFUS parameters by balancing transmission efficiency and thermal safety. The introduced FOM offers a novel metric to guide therapeutic applications, contributing to safer and more effective transcranial ultrasound treatments.


  • Open Access

    Imaging of macrophage accumulation in solid tumors with ultrasound

    by Ashley Alva, Chulyong Kim, Pranav Premdas, Yann Ferry, Hohyun Lee, Nidhi Lal, Bowen Jing, Edward Botchwey, Brooks D. Lindsey, Costas Arvanitis

    Imaging macrophage trafficking in solid tumors has major implications for cancer diagnosis, prognosis, and therapy. Here, we show that macrophage labeling with lipid-shelled microbubbles enables ultrasound imaging at single-cell level. Crucially, microbubble labeling and sonication at low mechanical indexes do not affect macrophage viability, migration, phenotype, and cytokine secretion profile, supporting the notion that ultrasound imaging can be used for nondestructive macrophage imaging. Despite the damping exerted on the microbubble oscillations by the cellular compartments, the microbubbles exhibit highly nonlinear behavior upon sonication, allowing for high specificity nonlinear US imaging under in vitro and in vivo conditions. Subsequently, we demonstrate that nonlinear ultrasound imaging can selectively monitor macrophage accumulation and extravasation in solid tumors in rodents for at least 8 h after intravenous administration. These findings establish ultrasound as a noninvasive platform for immune cell trafficking in solid tumors and highlight its potential to advance cancer diagnosis, monitoring, and therapy.


  • Open Access

    Data-driven feedback augments ultrasound nanotheranostics in brain tumors

    by Hohyun Lee, Victor Menezes, Shiqin Zeng, Chulyong Kim, Cynthia M. Baseman, Jae Hyun Kim, Samhita Padmanabhan, Pranav Premdas, Naima Djeddar, Anton Bryksin, et al.

    The blood-brain barrier (BBB) renders the delivery of nanomedicine in the brain ineffective and the detection of circulating disease-related DNA from the brain unreliable. Here, we show that the acoustic emission content of focused ultrasound-controlled microbubble dynamics (MB-FUS) incorporates precursor signals that allow large-data models to predict sonication regimens for safe and effective BBB opening. Crucially, closed-loop MB-FUS controller augmented by machine learning (ML-CL) expands the treatment window (4-fold), as compared to conventional controllers, by persistently and proactively maximizing the BBB permeability while preventing tissue damage. By successfully scaling up from mice to rats and from healthy to diseased brains (glioma), ML-CL rendered the BBB permeable to large nanoparticles and markedly improved the release and detection of tumor DNA in plasma. Together, our findings reveal the potential of data-driven feedback to support the development of next-generation AI-powered ultrasound systems for safe, robust, and efficient nanotheranostic targeting of brain diseases.

  • Top Cited Papers
    Open Access

    Ultrasound frequency-controlled microbubble dynamics in brain vessels regulate the enrichment of inflammatory pathways in the blood-brain barrier

    by Yutong Guo, Hohyun Lee, Chulyong Kim, Christian Park, Akane Yamamichi, Pavlina Chuntova, Marco Gallus, Miguel O. Bernabeu, Hideho Okada, Hanjoong Jo, et al.

    Microbubble-enhanced ultrasound provides a noninvasive physical method to locally overcome major obstacles to the accumulation of blood-borne therapeutics in the brain, posed by the blood-brain barrier (BBB). However, due to the highly nonlinear and coupled behavior of microbubble dynamics in brain vessels, the impact of microbubble resonant effects on BBB signaling and function remains undefined. Here, combined theoretical and prospective experimental investigations reveal that microbubble resonant effects in brain capillaries can control the enrichment of inflammatory pathways that are sensitive to wall shear stress and promote differential expression of a range of transcripts in the BBB, supporting the notion that microbubble dynamics exerted mechanical stress can be used to establish molecular, in addition to spatial, therapeutic windows to target brain diseases. Consistent with these findings, a robust increase in cytotoxic T-cell accumulation in brain tumors was observed, demonstrating the functional relevance and potential clinical significance of the observed immuno-mechano-biological responses.


  • A High Sensitivity CMUT-Based Passive Cavitation Detector for Monitoring Microbubble Dynamics During Focused Ultrasound Interventions

    by Reza Pakdaman Zangabad, Hohyun Lee, Xitie Zhang, M. Sait Kilinc, Costas D. Arvanitis, F. Levent Degertekin

    Tracking and controlling microbubble (MB) dynamics in the human brain through acoustic emission monitoring during transcranial focused ultrasound therapy (tFUS) is critical for attaining safe and effective treatments. The low-amplitude MB emissions have harmonic and ultra-harmonic components, necessitating a broad bandwidth and low-noise system for monitoring transcranial MB activity. Capacitive Micromachined Ultrasonic Transducers (CMUTs) offer high sensitivity and low noise over a broad bandwidth, especially when they are tightly integrated with electronics, making them a good candidate technology for monitoring the MB activity through human skull. In this study, we designed a 16-channel Analog Front-end Electronics (AFE) with a low-noise transimpedance amplifier (TIA), a band-gap reference circuit, and an output buffer stage. To assess AFE performance and ability to detect MB acoustic emission, we combined it with a commercial CMUT array. The integrated system has 12.3 − 61.25 mV/Pa receive sensitivity with 0.085 − 0.23 mPa/ √ Hz minimum detectable pressure up to 3 MHz for a single element CMUT with 3.78 mm 2 area. Experiments with free microbubbles in a microfluidic channel demonstrate that our system is able to capture key spectral components of MBs’ harmonics when sonicated at clinically relevant frequencies (0.5 MHz) and pressures (250 kPa). Together our results demonstrate that the proposed CMUT system can support the development of novel passive cavitation detectors to track MB activity for attaining safe and effective FUS treatments.


  • CMUT as a Transmitter for Microbubble-Assisted Blood-Brain Barrier Opening

    by M. Sait Kilinc, Reza Pakdaman Zangabad, Costas Arvanitis, F. Levent Degertekin

    Focused ultrasound (FUS) combined with microbubbles (MBs) has emerged as a promising strategy for transiently opening the blood-brain barrier (BBB) to enhance drug permeability in the brain. Current FUS systems for BBB opening use piezoelectric transducers as transmitters and receivers. While capacitive micromachined ultrasonic transducers (CMUTs) have been suggested as a FUS receiver alternative due to their broad bandwidth, their capabilities as transmitters have not been investigated. This is mainly due to the intrinsic nonlinear behavior of CMUTs which complicates the detection of MB generated harmonic signals and their low pressure output at FUS frequencies. Various methods have been proposed to mitigate CMUT nonlinearity; however, these approaches have primarily targeted contrast enhanced ultrasound imaging. In this study, we propose the use of polyphase modulation (PM) technique to isolate MB emissions when CMUTs are employed as transmitters for BBB opening. Our calculations for a human scale FUS system with multiple CMUT transmitters show that 10 kPa peak negative pressure at 150 mm focal distance will be sufficient for MB excitation for BBB opening. Experimental findings indicate that this pressure level can be easily generated at 400-800 kHz using a readily available CMUT. Furthermore, more than 50 dB suppression of the fundamental harmonic signal is obtained in free field and transcranial hydrophone measurements by processing receive signals in response to phase modulated transmit waveforms. In-vitro validation of PM is also conducted using Definity MB flowing through a tube phantom. MB-filled tube phantoms show adequate nonlinear signal isolation and SNR for MB harmonic detection. Together our findings indicate that PM can effectively mitigate CMUT harmonic generation, thereby creating new opportunities for wideband transmission and receive operation for BBB opening in clinical and preclinical applications.