KTKengo Takahashi

Kengo Takahashi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kengo Takahashi has a total of 67 co-authors. Here are the top co-authors by number of shared publications:

  • Youngseok Song

    Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan

    6 shared publications
  • Akitoshi Yoshida

    Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan

    5 shared publications
  • Akihiro Ishibazawa

    Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan

    3 shared publications
  • Takafumi Yoshioka

    Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan

    3 shared publications
  • Tomofumi Tani

    Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Hokkaido, Japan

    3 shared publications
  • Ching-Yu Cheng

    Singapore National Eye Centre, Singapore; Singapore Eye Research Institute, Singapore; Ophthalmology & Visual Sciences Academic Clinical Program (Eye ACP), Duke-NUS Medical School, Singapore; Yong Loo Lin School of Medicine, National University of Singapore, Singapore

    2 shared publications

Latest Publications

  • Open Access

    Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography

    by Tsubasa Abe, Takafumi Yoshioka, Youngseok Song, Tomofumi Tani, Motofumi Kawai, Tsuneaki Omae, Kengo Takahashi, Yoshitaka Takizawa, Tomoko Ro-Mase, Satoshi Ishiko, et al.

    Purpose: The purpose of this study was to evaluate the diagnostic performance of retinal blood flow (RBF) measured with the Doppler optical coherence tomography (OCT) segmental scanning method to distinguish between healthy and glaucoma eyes. Methods: Fifty-eight patients with normal tension glaucoma (NTG) who had a single-hemifield visual field defect and 44 age-matched healthy subjects were enrolled. Retinal nerve fiber layer thickness (RNFLT) was measured with swept-source OCT. Superior and inferior temporal arteries (TAs) and temporal veins (TVs) RBF were measured with Doppler OCT. The area under the curve (AUC) of the receiver operating characteristic (ROC) was used to compare the diagnostic performances in the damaged and normal hemispheres. Results: Multivariate regression analysis showed TA RBF and TV RBF were significantly reduced in the damaged and normal hemispheres. The ROC analysis showed that the AUC for quadrant RNFLT, TA RBF, and TV RBF were 0.973, 0.909, and 0.872 in the damaged hemisphere, respectively. The AUC values in the normal hemisphere were 0.783, 0.744, and 0.697, respectively. The combination of quadrant RNFLT and TA/TV RBF had a greater AUC than quadrant RNFLT alone in both damaged (AUC = 0.987) and normal (AUC = 0.825) hemispheres. Conclusions: In NTG eyes with single-hemifield damage, the RBF was found to be significantly reduced in the damaged and normal hemispheres independent from structural changes. The combination of RNFLT and RBF could improve diagnostic performances for glaucoma. Translational Relevance: Combining morphological and blood flow measurements with Doppler OCT may be useful in glaucoma diagnosis.


  • Normative Data and Associations of OCT Angiography Measurements of the Macula

    by Zhen Ling Teo, Christopher Ziyu Sun, Crystal Chun Yuen Chong, Yih-Chung Tham, Kengo Takahashi, Shivani Majithia, Cong Ling Teo, Tyler Hyungtaek Rim, Jacqueline Chua, Leopold Schmetterer, et al.


  • Patterns and Determinants of Choroidal Thickness in a Multiethnic Asian Population: The Singapore Epidemiology of Eye Diseases Study

    by Youngseok Song, Yih-Chung Tham, Crystal Chong, Ricardo Ong, Beau J. Fenner, Kai Xiong Cheong, Kengo Takahashi, Janice Marie Jordan-Yu, Kelvin Yi Chong Teo, Anna C.S. Tan, et al.


  • Open Access

    Deterioration of Retinal Blood Flow Parameters in Branch Retinal Vein Occlusion Measured by Doppler Optical Coherence Tomography Flowmeter

    by Kengo Takahashi, Youngseok Song, Kenji Sogawa, Takafumi Yoshioka, Tomofumi Tani, Satoshi Ishiko, Akitoshi Yoshida

    Background: Doppler optical coherence tomography (DOCT) flowmeter can be used to measure retinal blood flow (RBF) parameters, including vessel diameter, blood velocity, and the absolute value of RBF within 2.0 s. We investigated the RBF parameters in eyes with branch retinal vein occlusion (BRVO) using a DOCT flowmeter. Methods: Seventeen patients with unilateral BRVO were enrolled. All subjects underwent comprehensive ophthalmologic examinations. The RBF parameters were assessed from three veins, i.e., (1) an occluded vein, (2) a non-occluded vein in the BRVO eyes, and (3) an equivalent (superior or inferior) vein in the fellow eye (non-affected vein), using prototype DOCT flowmeter (Topcon, Tokyo, Japan). Moreover, the correlation between RBF parameters and the best corrected visual acuity (BCVA) was examined. We investigated the correlation between (1) the RBF parameters and the time from the initial visit, (2) the RBF parameters and the time from the last injection, and (3) the RBF parameters and the number of anti-vascular endothelial growth factor injections (VEGF). Results: The diameter of the occluded vein (95.9 ± 24.7 µm) was smaller than that of the non-occluded vein (127.9 ± 23.7 µm) and that of the healthy veins (116.4 ± 13.9 µm). The RBF was lower in the occluded veins (4.7 ± 3.7 µL/min) than that in the non-occluded veins (10.3 ± 5.1 µL/min; p < 0.01) and in the fellow eyes (8.6 ± 4.0 µL/min; p = 0.013). In contrast, the blood velocity was not significantly different among the three types of veins. BCVA was correlated with the diameter of the occluded vein (ρ = 0.711, p = 0.001) but not with the RBF and blood velocity. The time from the initial visit, the time from the last injection, and the total number of anti-VEGF injections were not associated with any RBF parameters on the occluded vein. Conclusions: The RBF was significantly lower in the occluded veins than that in the other veins, and the diameter of the occluded vein was significantly smaller than that of the other veins in patients with BRVO. However, neither the time from the initial visit, nor the time from the last injection, nor the number of anti-VEGF injections were correlated with the RBF parameters on the occluded vein.


  • Retinal blood flow reduction in normal-tension glaucoma with single-hemifield damage by Doppler optical coherence tomography

    by Takafumi Yoshioka, Youngseok Song, Motofumi Kawai, Tomofumi Tani, Kengo Takahashi, Satoshi Ishiko, Fabio Lavinsky, Gadi Wollstein, Hiroshi Ishikawa, Joel S Schuman, et al.

    Aims To evaluate the associations between retinal blood flow (RBF) and optical coherence tomography (OCT) structural measurements in normal-tension glaucoma (NTG) eyes with single-hemifield visual field (VF) damage by the Doppler OCT. Methods The Doppler OCT was used to measure temporal artery (TA) RBF and temporal vein (TV) RBF. Retinal nerve fibre layer thickness (RNFLT) was measured by spectral-domain OCT. Results Forty-three consecutive eyes of 43 patients with NTG with VF defect confined to a single hemifield and 24 eyes of 24 age-matched healthy subjects were studied. TA and TV RBF and RNFLT were reduced in the damaged hemisphere compared with the normal hemisphere (mean (SD), 3.61 (1.68) vs 5.86 (2.59) µL/min, pConclusion In NTG eyes with single-hemifield damage, the RBF was significantly reduced in the damaged hemisphere compared with the normal one. The RBF decreased in the normal and damaged hemispheres of NTG eyes compared with the healthy hemisphere independent from RNFLT.


  • Open Access

    Longitudinal Changes in Retinal Blood Flow in a Feline Retinal Vein Occlusion Model as Measured by Doppler Optical Coherence Tomography and Optical Coherence Tomography Angiography

    by Takanari Wada, Youngseok Song, Tsuneaki Oomae, Kenji Sogawa, Takafumi Yoshioka, Seigo Nakabayashi, Kengo Takahashi, Tomofumi Tani, Akihiro Ishibazawa, Satoshi Ishiko, et al.

    Purpose: We aimed to observe longitudinal changes in retinal blood flow (RBF) and structural transformations in capillaries using Doppler optical coherence tomography (DOCT) and optical coherence tomography angiography (OCTA) in a feline retinal blood occlusion (RVO) model. Methods: RVO was induced by argon green laser photocoagulation (PC) in six eyes of six cats. RBF was measured at a first-order retinal artery and vein by a DOCT flowmeter, and structural changes in the capillaries around the occluded vessels (12 × 12 and 3 × 3 mm) were assessed by OCTA before (at baseline); immediately after PC; and on days 1, 4, 7, and 14 thereafter. Systemic and ocular parameters were monitored during the observation period. Results: There were no significant differences in any systemic or ocular parameters before and after PC. Arterial RBF increased significantly on day 1 (160.6 ± 8.6% vs. baseline, P < 0.001) and decreased below baseline after day 1 through 14. Venous RBF decreased immediately after PC (17.4 ± 9.6% vs. baseline, P = 0.001) and then gradually increased afterwards, but did not return to baseline. OCTA showed dilatation of retinal venules immediately after PC to day 1. Collateral vessels began to form on day 4, had matured by day 7, and were pruned on day 14, which formed as mature as normal retinal venule diameters. Conclusions: With increasing arterial RBF within 1 day after inducing RVO, venules gradually expanded to form collateral vessels, suggesting that collateral vessels originate from existing capillary networks, not neovascularization.


  • Open Access

    Retinal blood flow reduction after panretinal photocoagulation in Type 2 diabetes mellitus: Doppler optical coherence tomography flowmeter pilot study

    by Youngseok Song, Tomofumi Tani, Tsuneaki Omae, Akihiro Ishibazawa, Takafumi Yoshioka, Kengo Takahashi, Masahiro Akiba, Akitoshi Yoshida

    To use a Doppler optical coherence tomography (DOCT) flowmeter to investigate segmental retinal blood flow (RBF) and sum of the segmental RBFs (SRBF) changes after panretinal photocoagulation (PRP) was used to treat type 2 diabetes mellitus with severe diabetic retinopathy (DR). Data from five patients with proliferative DR (PDR) (mean age 51.9 ± 10.5 years) was analyzed. The vessel diameter (D), average velocity (V), and retinal blood flow (RBF) in veins were measured using a DOCT flowmeter before and four weeks after PRP. Segmental RBF from inferotemporal (IT), superotemporal (ST), inferonasal (IN), and superonasal (SN) veins were measured, and SRBF was defined as the sum of these measurements. All data were analyzed by Wilcoxson test. After PRP, there were statistically significant decreases in the every segmental D, V, RBF (P.03) and SRBF (P = 0.002). The other parameters showed no statistically significant differences (P>0.05). The DOCT flowmeter has the potential to be a clinically useful tool to noninvasively evaluate the changes in retinal circulation during PRP in patients with PDR.


  • Thrombin-Induced Responses via Protease-Activated Receptor 1 Blocked by the Endothelium on Isolated Porcine Retinal Arterioles

    by Kengo Takahashi, Tsuneaki Omae, Shinji Ono, Takayuki Kamiya, Akira Tanner, Akitoshi Yoshida

    Purpose: Thrombin, a serine protease, causes organ-specific responses to vessels. However, the mechanism by which thrombin affects the retinal microcirculation remains unclear. We examined the effects of thrombin on the retinal microvasculature and signaling mechanisms. Methods: Porcine retinal arterioles were isolated, cannulated, and pressurized (55 cmH2O) without flow in this in vitro study. Videomicroscopy techniques recorded changes in diameter in the retinal arterioles in response to thrombin at concentrations ranging from 0.001 to 20 mU/ml. Results: Extraluminal administration of thrombin induced concentration-dependent vascular responses, that is, vasoconstriction at low concentrations less than 5 mU/ml and vasorelaxation with high concentrations greater than 5 mU/ml. However, intraluminal administration of thrombin (5 mU/m) did not constrict the retinal arterioles; in denuded vessels, intraluminal administration constricted the retinal arterioles. Thrombin-induced vasoconstriction was significantly (p < 0.01) suppressed by pretreatment with a protein kinase C (PKC) inhibitor and a protease-activated receptor (PAR)-1 inhibitor but not by PAR-2 and PAR-4 inhibitors or denudation. A rho kinase (ROCK) inhibitor also suppressed thrombin-induced vasoconstriction (5 mU/ml) compared with sodium nitroprusside. Endothelial denudation and pretreatment with an endothelial nitric oxide (NO) synthase inhibitor suppressed vasorelaxation caused by a high concentration of thrombin. Conclusions: A low concentration of thrombin causes vasoconstriction of smooth muscles via PAR-1, PKC, and ROCK, and a high concentration of thrombin possibly causes vasorelaxation of the retinal arterioles via nitric oxide synthase activation in the endothelium. The vascular endothelium might block signaling of thrombin-induced vasoconstriction in the retinal arterioles when administered intraluminally.