Mikkel Taudorf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mikkel Taudorf has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Lars Lönn
Department of Radiology, X2021 Rigshospitalet, Copenhagen, Denmark
13 shared publications - Michael Bachmann Nielsen
Department of Radiology, Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark
6 shared publications - Torben Veith Schroeder
Centre for Clinical Education at Rigshospitalet and University of Copenhagen, Denmark
4 shared publications K.C. Vogt
Department of Vascular Surgery, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
3 shared publications- Timothy Andrew Resch
Department of Vascular Surgery, Copenhagen University Hospital Rigshospitalet, Blegdamsvej 9, 2100 Copenhagen, Denmark
3 shared publications - Alexandra Annelie Brandtzäg
Department of Vascular Surgery, The Heart Center, Copenhagen University Hospital-Rigshospitalet, 2100 Copenhagen, Denmark
2 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Elsevier in EJVES Vascular Forum
- Vol. 65, 162-169
Evaluation of Imaging Modalities for Superior Mesenteric Artery Stenosis: A Single Centre Study
- 14 March 2026
- Published by Elsevier in EJVES Vascular Forum
- Vol. 65, 162-169
Open AccessEvaluation of Imaging Modalities for Superior Mesenteric Artery Stenosis: A Single Centre Study
- Open Access
- 30 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8507
Intraoperative Diagnostic Methods for Superior Mesenteric Artery Stenting in Chronic Mesenteric Ischemia
Background/Objectives: Chronic mesenteric ischemia (CMI) due to superior mesenteric artery (SMA) stenosis can be effectively treated with endovascular therapy (EVT). Appropriate intraoperative assessment is crucial for ensuring technical success and long-term patency. This study assesses intra-arterial pressure measurement (IAPM), and cone beam computed tomography (CBCT) for detecting residual stenosis during SMA stenting in CMI. Methods: This prospective study included 50 consecutive elective patients with symptomatic, significant SMA stenosis scheduled for EVT. The patients in this study were a subset of an ongoing randomized trial with a different primary objective. Intraoperative diagnostic tools—digital subtraction angiography (DSA), IAPM and CBCT were performed after stent placement. Technical success was defined as p = 0.024), the Odds ratio suggests that DSA detected fewer positive cases compared to CBCT (Odds ratio 0.176; 95% CI: 0.004–1.37; p = 0.13). DSA also differed significantly from IAPM (Kappa = 0.016, p = 0.882), (Odds ratio = 0.167; 95% CI: 0.018–0.749; p = 0.013), suggesting DSA under-detects residual stenosis (>10 mmHg). No significant difference was found between CBCT and IAPM (Kappa = 0.201, p = 0.161) (Odds ratio: 2.25, 95% CI: 0.628–10.0%; p = 0.27) indicating comparable results. Conclusions: DSA overlooks clinically important residual stenosis that could be treated during the primary procedure. CBCT aids structural assessment of the stent and allows for on-table optimizing of the procedural outcomes.
- 30 November 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (23) , 8507
Open AccessIntraoperative Diagnostic Methods for Superior Mesenteric Artery Stenting in Chronic Mesenteric Ischemia
Background/Objectives: Chronic mesenteric ischemia (CMI) due to superior mesenteric artery (SMA) stenosis can be effectively treated with endovascular therapy (EVT). Appropriate intraoperative assessment is crucial for ensuring technical success and long-term patency. This study assesses intra-arterial pressure measurement (IAPM), and cone beam computed tomography (CBCT) for detecting residual stenosis during SMA stenting in CMI. Methods: This prospective study included 50 consecutive elective patients with symptomatic, significant SMA stenosis scheduled for EVT. The patients in this study were a subset of an ongoing randomized trial with a different primary objective. Intraoperative diagnostic tools—digital subtraction angiography (DSA), IAPM and CBCT were performed after stent placement. Technical success was defined as p = 0.024), the Odds ratio suggests that DSA detected fewer positive cases compared to CBCT (Odds ratio 0.176; 95% CI: 0.004–1.37; p = 0.13). DSA also differed significantly from IAPM (Kappa = 0.016, p = 0.882), (Odds ratio = 0.167; 95% CI: 0.018–0.749; p = 0.013), suggesting DSA under-detects residual stenosis (>10 mmHg). No significant difference was found between CBCT and IAPM (Kappa = 0.201, p = 0.161) (Odds ratio: 2.25, 95% CI: 0.628–10.0%; p = 0.27) indicating comparable results. Conclusions: DSA overlooks clinically important residual stenosis that could be treated during the primary procedure. CBCT aids structural assessment of the stent and allows for on-table optimizing of the procedural outcomes.
- Open Access
- 15 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2564
Reduction in Synovitis Following Genicular Artery Embolization in Knee Osteoarthritis: A Prospective Ultrasound and MRI Study
Background/Objectives: Genicular artery embolization (GAE) has demonstrated potential as a treatment for knee osteoarthritis by targeting inflammation and pain, although current evidence remains limited. This study used imaging biomarkers to objectively assess synovitis and possible ischemic complications following GAE. Methods: This was a prospective, single-center trial including participants with mild-to-moderate knee osteoarthritis. Ultrasound, contrast-enhanced (CE), and non-CE-MRI were performed two days before and one and six months after GAE. Ultrasound biomarkers included synovial hypertrophy, effusion, and Doppler activity. A combined effusion-synovitis score was assessed on non-CE-MRI, while CE-MRI allowed differentiation between synovium and effusion and was used to calculate whole-joint and local synovitis scores. The post-GAE MRIs were reviewed for ischemic complications. Results: Seventeen participants (aged 43–71) were treated. Significant reductions were observed in ultrasound-assessed synovial hypertrophy and Doppler activity, as well as in CE-MRI local and whole-joint synovitis scores. While reductions in effusion were noted in both ultrasound and MRI, these changes did not reach statistical significance. At one month, MRI revealed three cases of nonspecific osteonecrosis-like areas, which resolved completely by six months. Conclusions: This study demonstrated a reduction in synovitis and no permanent ischemic complication following GAE in knee osteoarthritis. Larger studies with longer follow-up are needed to confirm the long-term efficacy and safety of the procedure.
- 15 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2564
Open AccessReduction in Synovitis Following Genicular Artery Embolization in Knee Osteoarthritis: A Prospective Ultrasound and MRI Study
Background/Objectives: Genicular artery embolization (GAE) has demonstrated potential as a treatment for knee osteoarthritis by targeting inflammation and pain, although current evidence remains limited. This study used imaging biomarkers to objectively assess synovitis and possible ischemic complications following GAE. Methods: This was a prospective, single-center trial including participants with mild-to-moderate knee osteoarthritis. Ultrasound, contrast-enhanced (CE), and non-CE-MRI were performed two days before and one and six months after GAE. Ultrasound biomarkers included synovial hypertrophy, effusion, and Doppler activity. A combined effusion-synovitis score was assessed on non-CE-MRI, while CE-MRI allowed differentiation between synovium and effusion and was used to calculate whole-joint and local synovitis scores. The post-GAE MRIs were reviewed for ischemic complications. Results: Seventeen participants (aged 43–71) were treated. Significant reductions were observed in ultrasound-assessed synovial hypertrophy and Doppler activity, as well as in CE-MRI local and whole-joint synovitis scores. While reductions in effusion were noted in both ultrasound and MRI, these changes did not reach statistical significance. At one month, MRI revealed three cases of nonspecific osteonecrosis-like areas, which resolved completely by six months. Conclusions: This study demonstrated a reduction in synovitis and no permanent ischemic complication following GAE in knee osteoarthritis. Larger studies with longer follow-up are needed to confirm the long-term efficacy and safety of the procedure.
- 21 October 2024
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 409 (1) , 1-11
Follow-up strategies after non-operative treatment of traumatic splenic injuries: a systematic review
Purpose Blunt trauma often results in splenic injuries, with non-operative management (NOM) being the preferred approach for stable patients. Following NOM, splenic vascular injuries, such as pseudoaneurysms, may arise, prompting radiological follow-up. However, a consensus on optimal radiological follow-up strategies is lacking. This systematic review evaluates existing evidence on radiological follow-up post-NOM for traumatic splenic injuries. Methods Conducting a systematic review following updated PRISMA guidelines, we searched MEDLINE, Embase, The Cochrane Library, and trial registries from January 2010 to March 2023. Inclusion criteria covered studies on radiological follow-up for blunt splenic injuries. Results Out of 5794 studies, 17 were included involving 3392 patients. Various radiological modalities were used, with computed tomography (CT) being the most common. Vascular injuries occurred in 4.5% of patients, with most pseudoaneurysms diagnosed on day 2–6 post-trauma, and leading to intervention in 60% of these cases. Thirteen studies recommended routine follow-up, with six favouring CT, and seven supporting radiation-free modalities. Four studies proposed follow-up based on clinical indications, initial findings, or symptoms. Recommendations for specific timing of radiological follow-up ranged from 48 h to seven days post-injury. Regarding AAST grading, nine studies recommended follow-up for injury grade III and higher. Conclusion Limited high-quality evidence exists on radiological follow-up in isolated blunt splenic injuries, causing uncertainty in clinical practice. However, our review suggests a reasonable need for follow-up, with contrast-enhanced ultrasound emerging as a promising alternative to CT. Specific timing and criteria for follow-up remain unresolved, highlighting the need for high-quality prospective studies to address these knowledge gaps.
- 21 October 2024
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 409 (1) , 1-11
Follow-up strategies after non-operative treatment of traumatic splenic injuries: a systematic review
Purpose Blunt trauma often results in splenic injuries, with non-operative management (NOM) being the preferred approach for stable patients. Following NOM, splenic vascular injuries, such as pseudoaneurysms, may arise, prompting radiological follow-up. However, a consensus on optimal radiological follow-up strategies is lacking. This systematic review evaluates existing evidence on radiological follow-up post-NOM for traumatic splenic injuries. Methods Conducting a systematic review following updated PRISMA guidelines, we searched MEDLINE, Embase, The Cochrane Library, and trial registries from January 2010 to March 2023. Inclusion criteria covered studies on radiological follow-up for blunt splenic injuries. Results Out of 5794 studies, 17 were included involving 3392 patients. Various radiological modalities were used, with computed tomography (CT) being the most common. Vascular injuries occurred in 4.5% of patients, with most pseudoaneurysms diagnosed on day 2–6 post-trauma, and leading to intervention in 60% of these cases. Thirteen studies recommended routine follow-up, with six favouring CT, and seven supporting radiation-free modalities. Four studies proposed follow-up based on clinical indications, initial findings, or symptoms. Recommendations for specific timing of radiological follow-up ranged from 48 h to seven days post-injury. Regarding AAST grading, nine studies recommended follow-up for injury grade III and higher. Conclusion Limited high-quality evidence exists on radiological follow-up in isolated blunt splenic injuries, causing uncertainty in clinical practice. However, our review suggests a reasonable need for follow-up, with contrast-enhanced ultrasound emerging as a promising alternative to CT. Specific timing and criteria for follow-up remain unresolved, highlighting the need for high-quality prospective studies to address these knowledge gaps.
- Open Access
- 27 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (15) , 1627
Transarterial Embolization of Geniculate Arteries Reduces Pain and Improves Physical Function in Knee Osteoarthritis—A Prospective Cohort Study
Knee osteoarthritis (OA) affects millions worldwide, leading to pain and reduced quality of life. Conventional treatments often fail to provide adequate relief, necessitating new therapeutic approaches. This study evaluated the efficacy and safety of genicular artery embolization (GAE) using permanent microspheres in patients with mild-to-moderate knee OA. In this prospective, single-center study, 17 participants underwent GAE. KOOS (Knee injury and Osteoarthritis Outcome Score), WOMAC (The Western Ontario and McMaster Universities Arthritis Index), and IPAQ (International Physical Activity Questionnaire) scores, along with physical performance tests, medication use, and dual-energy X-ray absorptiometry (DEXA) scans, were assessed at baseline and at multiple follow-up points over six months. The primary endpoint, VAS at six months, showed significant improvement (median reduction from 66 mm to 40 mm, p = 0.0004). All pain and function scores, as well as physical performance tests, improved significantly. No clinically relevant changes in medication use or DEXA parameters were observed after six months. Only minor, self-limiting adverse events occurred. This study indicates that GAE is a promising minimally invasive treatment for knee OA, providing significant pain relief and functional improvement. However, further long-term, randomized trials are needed to confirm these findings and establish optimal patient selection criteria.
- 27 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (15) , 1627
Open AccessTransarterial Embolization of Geniculate Arteries Reduces Pain and Improves Physical Function in Knee Osteoarthritis—A Prospective Cohort Study
Knee osteoarthritis (OA) affects millions worldwide, leading to pain and reduced quality of life. Conventional treatments often fail to provide adequate relief, necessitating new therapeutic approaches. This study evaluated the efficacy and safety of genicular artery embolization (GAE) using permanent microspheres in patients with mild-to-moderate knee OA. In this prospective, single-center study, 17 participants underwent GAE. KOOS (Knee injury and Osteoarthritis Outcome Score), WOMAC (The Western Ontario and McMaster Universities Arthritis Index), and IPAQ (International Physical Activity Questionnaire) scores, along with physical performance tests, medication use, and dual-energy X-ray absorptiometry (DEXA) scans, were assessed at baseline and at multiple follow-up points over six months. The primary endpoint, VAS at six months, showed significant improvement (median reduction from 66 mm to 40 mm, p = 0.0004). All pain and function scores, as well as physical performance tests, improved significantly. No clinically relevant changes in medication use or DEXA parameters were observed after six months. Only minor, self-limiting adverse events occurred. This study indicates that GAE is a promising minimally invasive treatment for knee OA, providing significant pain relief and functional improvement. However, further long-term, randomized trials are needed to confirm these findings and establish optimal patient selection criteria.
- Open Access
- 16 February 2024
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (4) , 1867-1872
Cholangioscopy with Spyglass DS using percutaneous transhepatic cholangiography access: a retrospective cohort study
Background: Conventional peroral methods to visualize biliary strictures are not feasible in some patients with altered anatomy or biliary obstruction, and percutaneous transhepatic cholangioscopy can be used as an alternative procedure. This study aimed to retrospectively review the use of percutaneous transhepatic cholangiography using the SpyGlass DS technology (S-PTCS) during a 5-year period at a Danish tertiary referral centre. Materials and methods: All patients who underwent S-PTCS at a single Danish tertiary referral centre between 2016 and 2021 were retrospectively analyzed. The visual, technical, and overall success rates of S-PTCS were analyzed, as well as the complication rate. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of S-PTCS were calculated. Results: Twenty-two patients were included in the study. Visual, technical, and overall success of S-PTCS was achieved in 17/22, 22/22, and 21/22 patients, respectively. S-PTCS yielded a sensitivity of 83.3%, a specificity of 100%, a PPV of 100%, a NPV of 94.1%, and an accuracy of 95.4%. Complications occurred in 1/22 patients. Conclusion: S-PTCS is a safe modality, with high success rates, high predictive values, and a low rate of complications. This study suggests that S-PTCS is an alternative to conventional methods in patients with indeterminate biliary strictures where conventional methods were unfeasible.
- 16 February 2024
- Published by Wolters Kluwer Health in Annals of Medicine & Surgery
- Vol. 86 (4) , 1867-1872
Open AccessCholangioscopy with Spyglass DS using percutaneous transhepatic cholangiography access: a retrospective cohort study
Background: Conventional peroral methods to visualize biliary strictures are not feasible in some patients with altered anatomy or biliary obstruction, and percutaneous transhepatic cholangioscopy can be used as an alternative procedure. This study aimed to retrospectively review the use of percutaneous transhepatic cholangiography using the SpyGlass DS technology (S-PTCS) during a 5-year period at a Danish tertiary referral centre. Materials and methods: All patients who underwent S-PTCS at a single Danish tertiary referral centre between 2016 and 2021 were retrospectively analyzed. The visual, technical, and overall success rates of S-PTCS were analyzed, as well as the complication rate. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of S-PTCS were calculated. Results: Twenty-two patients were included in the study. Visual, technical, and overall success of S-PTCS was achieved in 17/22, 22/22, and 21/22 patients, respectively. S-PTCS yielded a sensitivity of 83.3%, a specificity of 100%, a PPV of 100%, a NPV of 94.1%, and an accuracy of 95.4%. Complications occurred in 1/22 patients. Conclusion: S-PTCS is a safe modality, with high success rates, high predictive values, and a low rate of complications. This study suggests that S-PTCS is an alternative to conventional methods in patients with indeterminate biliary strictures where conventional methods were unfeasible.
- 1 April 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 72, 321-329
Three- and Two-Dimensional Ultrasound is as Accurate as Computed Tomography in Aortic Sac Assessment after Endovascular Aortic Repair
- 1 April 2021
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 72, 321-329
Three- and Two-Dimensional Ultrasound is as Accurate as Computed Tomography in Aortic Sac Assessment after Endovascular Aortic Repair
- Open Access
- 1 January 2021
- Published by The Korean Surgical Society in Annals of Surgical Treatment and Research
- Vol. 101 (2) , 129-130
Comments on “A course on endovascular training for resuscitative endovascular balloon occlusion of the aorta: a pilot study for residents and specialists”
Engberg M, et al. Ann Surg Treat Res. 2021 Aug;101(2):129-130. https://doi.org/10.4174/astr.2021.101.2.129
- 1 January 2021
- Published by The Korean Surgical Society in Annals of Surgical Treatment and Research
- Vol. 101 (2) , 129-130
Open AccessComments on “A course on endovascular training for resuscitative endovascular balloon occlusion of the aorta: a pilot study for residents and specialists”
Engberg M, et al. Ann Surg Treat Res. 2021 Aug;101(2):129-130. https://doi.org/10.4174/astr.2021.101.2.129
- Open Access
- 13 October 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (10) , 814
Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn’s disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1–3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn’s disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.
- 13 October 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (10) , 814
Open AccessGastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
Dual-energy computed tomography (DECT) can estimate tissue vascularity and perfusion via iodine quantification. The aim of this systematic review was to outline current and emerging clinical applications of iodine quantification within the gastrointestinal tract using DECT. The search was conducted with three databases: EMBASE, Pubmed and The Cochrane Library. This identified 449 studies after duplicate removal. From a total of 570 selected studies, 30 studies were enrolled for the systematic review. The studies were categorized into four main topics: gastric tumors (12 studies), colorectal tumors (8 studies), Crohn’s disease (4 studies) and miscellaneous applications (6 studies). Findings included a significant difference in iodine concentration (IC) measurements in perigastric fat between T1–3 vs. T4 stage gastric cancer, poorly and well differentiated gastric and colorectal cancer, responders vs. non-responders following chemo- or chemoradiotherapy treatment among cancer patients, and a positive correlation between IC and Crohn’s disease activity. In conclusion, iodine quantification with DECT may be used preoperatively in cancer imaging as well as for monitoring treatment response. Future studies are warranted to evaluate the capabilities and limitations of DECT in splanchnic flow.