ZLZihui Li

Zihui Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zihui Li has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Solid-State Supercritical CO2 Foaming of PCL/PLGA Blends: Cell Opening and Compression Behavior

    by Haiyang Guo, Jing Jiang, Zihui Li, Zhangyong Jin, Jianhua Hou, Xiaofeng Wang, Qian Li


  • Open Access

    Mechanical regulation of bone formation and resorption around implants in a mouse model of osteopenic bone

    by Zihui Li, Duncan Betts, Gisela Kuhn, Michael Schirmer, Ralph Müller, Davide Ruffoni

    Although mechanical stimulation is considered a promising approach to accelerate implant integration, our understanding of load-driven bone formation and resorption around implants is still limited. This lack of knowledge may delay the development of effective loading protocols to prevent implant loosening, especially in osteoporosis. In healthy bone, formation and resorption are mechanoregulated processes. In the intricate context of peri-implant bone regeneration, it is not clear whether bone (re)modelling can still be load-driven. Here, we investigated the mechanical control of peri-implant bone (re)modelling with a well-controlled mechanobiological experiment. We applied cyclic mechanical loading after implant insertion in tail vertebrae of oestrogen depleted mice and we monitored peri-implant bone response byin vivomicro-CT. Experimental data were combined with micro-finite element simulations to estimate local tissue strains in (re)modelling locations. We demonstrated that a substantial increase in bone mass around the implant could be obtained by loading the entire bone. This augmentation could be attributed to a large reduction in bone resorption rather than to an increase in bone formation. We also showed that following implantation, mechanical regulation of bone (re)modelling was transiently lost. Our findings should help to clarify the role of mechanical stimulation on the maintenance of peri-implant bone mass.


  • Open Access

    Generation of Vestibular Tissue-Like Organoids From Human Pluripotent Stem Cells Using the Rotary Cell Culture System

    by Cristiana Mattei, Rebecca Lim, Hannah Drury, Babak Nasr, Zihui Li, Melissa A. Tadros, Giovanna M. D'Abaco, Kathryn S. Stok, Bryony A. Nayagam, Mirella Dottori

    Hair cells are specialized mechanosensitive cells responsible for mediating balance and hearing within the inner ear. In mammals, hair cells are limited in number and do not regenerate. Human pluripotent stem cells (hPSCs) provide a valuable source for deriving human hair cells to study their development and design therapies to treat and/or prevent their degeneration. In this study we used a dynamic 3D Rotary Cell Culture System (RCCS) for deriving inner ear organoids from hPSCs. We show RCCS-derived organoids recapitulate stages of inner ear development and give rise to an enriched population of hair cells displaying vestibular-like morphological and physiological phenotypes, which resemble developing human fetal inner ear hair cells as well as the presence of accessory otoconia-like structures. These results show that hPSC-derived organoids can generate complex inner ear structural features and be a resource to study inner ear development.


  • Bone remodeling and mechanobiology around implants: Insights from small animal imaging

    by Zihui Li, Ralph Müller, Davide Ruffoni

    Anchorage of orthopedic implants depends on the interfacial bonding between the implant and the host bone as well as on the mass and microstructure of peri‐implant bone, with all these factors being continuously regulated by the biological process of bone (re)modeling. In osteoporotic bone, implant integration may be jeopardized not only by lower peri‐implant bone quality but also by reduced intrinsic regeneration ability. The first aim of this review is to provide a critical overview of the influence of osteoporosis on bone regeneration post‐implantation. Mechanical stimulation can trigger bone formation and inhibit bone resorption; thus, judicious administration of mechanical loading can be used as an effective non‐pharmacological treatment to enhance implant anchorage. Our second aim is to report recent achievements on the application of external mechanical stimulation to improve the quantity of peri‐implant bone. The review focuses on peri‐implant bone changes in osteoporotic conditions and following mechanical loading, prevalently using small animals and in vivo monitoring approaches. We intend to demonstrate the necessity to reveal new biological information on peri‐implant bone mechanobiology to better target implant anchorage and fracture fixation in osteoporotic conditions. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:584–593, 2018.


  • Open Access

    Impaired bone formation in ovariectomized mice reduces implant integration as indicated by longitudinal in vivo micro-computed tomography

    by Zihui Li, Gisela Kuhn, Michael Schirmer, Ralph Müller, Davide Ruffoni

    Although osteoporotic bone, with low bone mass and deteriorated bone architecture, provides a less favorable mechanical environment than healthy bone for implant fixation, there is no general agreement on the impact of osteoporosis on peri-implant bone (re)modeling, which is ultimately responsible for the long term stability of the bone-implant system. Here, we inserted an implant in a mouse model mimicking estrogen deficiency-induced bone loss and we monitored with longitudinal in vivo micro-computed tomography the spatio-temporal changes in bone (re)modeling and architecture, considering the separate contributions of trabecular, endocortical and periosteal surfaces. Specifically, 12 week-old C57BL/6J mice underwent OVX/SHM surgery; 9 weeks after we inserted special metal-ceramics implants into the 6th caudal vertebra and we measured bone response with in vivo micro-CT weekly for the following 6 weeks. Our results indicated that ovariectomized mice showed a reduced ability to increase the thickness of the cortical shell close to the implant because of impaired peri-implant bone formation, especially at the periosteal surface. Moreover, we observed that healthy mice had a significantly higher loss of trabecular bone far from the implant than estrogen depleted animals. Such behavior suggests that, in healthy mice, the substantial increase in peri-implant bone formation which rapidly thickened the cortex to secure the implant may raise bone resorption elsewhere and, specifically, in the trabecular network of the same bone but far from the implant. Considering the already deteriorated bone structure of estrogen depleted mice, further bone loss seemed to be hindered. The obtained knowledge on the dynamic response of diseased bone following implant insertion should provide useful guidelines to develop advanced treatments for osteoporotic fracture fixation based on local and selective manipulation of bone turnover in the peri-implant region.


  • In vivo monitoring of bone architecture and remodeling after implant insertion: The different responses of cortical and trabecular bone

    by Zihui Li, Gisela Kuhn, Marcella von Salis-Soglio, Stephen J. Cooke, Michael Schirmer, Ralph Müller, Davide Ruffoni


  • Osteocyte-derived insulin-like growth factor I is essential for determining bone mechanosensitivity

    by K.-H. William Lau, David J. Baylink, Xiao-Dong Zhou, Denise Rodriguez, Lynda F. Bonewald, Zihui Li, Davide Ruffoni, Ralph Müller, Chandrasekhar Kesavan, Matilda H.-C. Sheng

    This study sought to determine whether deficient Igf1 expression in osteocytes would affect loading-induced osteogenic response. Tibias of osteocyte Igf1 conditional knockout (KO) mice (generated by cross-breeding Igf1 floxed mice with Dmp1- Cre transgenic mice) and wild-type (WT) littermates were subjected to four-point bending for 2 wk. Microcomputed tomography confirmed that the size of tibias of conditional mutants was smaller. Loading with an equivalent loading strain increased periosteal woven bone and endosteal lamellar bone formation in WT mice but not in conditional KO mice. Consistent with the lack of an osteogenic response, the loading failed to upregulate expression of early mechanoresponsive genes ( Igf1, Cox-2, c-fos) or osteogenic genes ( Cbfa-1, and osteocalcin) in conditional KO bones. The lack of osteogenic response was not due to reduced osteocyte density or insufficient loading strain. Deficient osteocyte Igf1 expression reduced the loading-induced upregulation of expression of canonical Wnt signaling genes ( Wnt10b, Lrp5, Dkk1, sFrp2). The loading also reduced (by 40%) Sost expression in WT mice, but the loading not only did not reduce but upregulated (∼1.5-fold) Sost expression in conditional KO mice. Conditional disruption of Igf1 in osteocytes also abolished the loading-induced increase in the bone β-catenin protein level. These findings suggest an impaired response in the loading-induced upregulation of the Wnt signaling in conditional KO mice. In summary, conditional disruption of Igf1 in osteocytes abolished the loading-induced activation of the Wnt signaling and the corresponding osteogenic response. In conclusion, osteocyte-derived IGF-I plays a key determining role in bone mechanosensitivity.


  • Open Access

    Effects of a hybrid micro/nanorod topography-modified titanium implant on adhesion and osteogenic differentiation in rat bone marrow mesenchymal stem cells

    by Xinquan Jiang, Wenjie Zhang, Zihui Li, Ling Xu, Yuqin Jin, Guifang Wang, Xuanyong Liu, Qingfeng Huang, Jinhua Li

    Background and methods: Various methods have been used to modify titanium implant surfaces with the aim of achieving better osseointegration. In this study, we fabricated a clustered nanorod structure on an acid-etched, microstructured titanium plate surface using hydrogen peroxide. We also evaluated biofunctionalization of the hybrid micro/nanorod topography on rat bone marrow mesenchymal stem cells. Scanning electron microscopy and x-ray diffraction were used to investigate the surface topography and phase composition of the modified titanium plate. Rat bone marrow mesenchymal stem cells were cultured and seeded on the plate. The adhesion ability of the cells was then assayed by cell counting at one, 4, and 24 hours after cell seeding, and expression of adhesion-related protein integrin β1 was detected by immunofluorescence. In addition, a polymerase chain reaction assay, alkaline phosphatase and Alizarin Red S staining assays, and osteopontin and osteocalcin immunofluorescence analyses were used to evaluate the osteogenic differentiation behavior of the cells. Results: The hybrid micro/nanoscale texture formed on the titanium surface enhanced the initial adhesion activity of the rat bone marrow mesenchymal stem cells. Importantly, the hierarchical structure promoted osteogenic differentiation of these cells. Conclusion: This study suggests that a hybrid micro/nanorod topography on a titanium surface fabricated by treatment with hydrogen peroxide followed by acid etching might facilitate osseointegration of a titanium implant in vivo.