Pierre Joseph
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pierre Joseph has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- Antoine Naillon
Univ. Grenoble Alpes CNRS Grenoble INP LRP 38000 Grenoble France
5 shared publications - Aurélien Bancaud
Institute of Industrial Science, The University of Tokyo, Tokyo 153-8505, Japan
4 shared publications - Clément Roux
Laboratoire Softmat, Université de Toulouse, CNRS UMR 5623, Université Toulouse III – Paul Sabatier, 118 Route de Narbonne, 31062 Toulouse, France
4 shared publications David Bourrier
LAAS-CNRS, Université de Toulouse, CNRS 1 , Toulouse, France
4 shared publicationsAdrian Laborde
LAAS-CNRS, Université de Toulouse, CNRS 1 , Toulouse, France
3 shared publicationsAnne-Marie Gué
CNRS, LAAS, Toulouse, France
3 shared publications
Latest Publications
- Open Access
- 1 June 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026122
Parallel on-chip micropipettes enabling quantitative multiplexed characterization of vesicle mechanics and cell aggregates rheology
Micropipette aspiration (MPA) is one of the gold standards for quantifying biological samples' mechanical properties, which are crucial from the cell membrane scale to the multicellular tissue. However, relying on the manipulation of individual home-made glass pipettes, MPA suffers from low throughput and no automation. Here, we introduce the sliding insert micropipette aspiration method, which permits parallelization and automation, thanks to the insertion of tubular pipettes, obtained by photolithography, within microfluidic channels. We show its application both at the lipid bilayer level, by probing vesicles to measure membrane bending and stretching moduli, and at the tissue level by quantifying the viscoelasticity of 3D cell aggregates. This approach opens the way to high-throughput, quantitative mechanical testing of many types of biological samples, from vesicles and individual cells to cell aggregates and explants, under dynamic physico-chemical stimuli.
- 1 June 2024
- Published by AIP Publishing in APL Bioengineering
- Vol. 8 (2) , 026122
Open AccessParallel on-chip micropipettes enabling quantitative multiplexed characterization of vesicle mechanics and cell aggregates rheology
Micropipette aspiration (MPA) is one of the gold standards for quantifying biological samples' mechanical properties, which are crucial from the cell membrane scale to the multicellular tissue. However, relying on the manipulation of individual home-made glass pipettes, MPA suffers from low throughput and no automation. Here, we introduce the sliding insert micropipette aspiration method, which permits parallelization and automation, thanks to the insertion of tubular pipettes, obtained by photolithography, within microfluidic channels. We show its application both at the lipid bilayer level, by probing vesicles to measure membrane bending and stretching moduli, and at the tissue level by quantifying the viscoelasticity of 3D cell aggregates. This approach opens the way to high-throughput, quantitative mechanical testing of many types of biological samples, from vesicles and individual cells to cell aggregates and explants, under dynamic physico-chemical stimuli.
- 28 March 2024
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 9 (3) , 034202
Hydrodynamic resistance of a yeast clog
Bioclogging, the clogging of pores with living particles, is a complex process that involves various coupled mechanisms such as hydrodynamics and particle properties. The lack of sensitive methods to simultaneously measure the hydraulic resistance of a clog and the position of particles at high enough resolutions limits our understanding of this tight fluid-structure interplay. In this article, we explored bioclogging at the microscale level, where flow rates are typically extremely low (). We developed a highly sensitive method to precisely measure small flow rates ( error) with a low response time () while retaining the capability to image the structure of a fluorescently labeled yeast clog at high resolution. This method employed a microfluidic device with two identical channels: a first one for a yeast suspension and a second one for a colored culture medium. These channels merged into a single wide outlet channel, where the interface of the colored medium and the medium coming from the yeast clog could be monitored. As a yeast clog formed in the first channel, the displacement of the interface between the two media was imaged and compared to a pre-calibrated image database, quantifying the flow through the clog. We carried out two kinds of experiments to explore the fluid-clog interaction: filtration under constant operating pressure and filtration under oscillating operating pressure (backflush cycles). We found that in both scenarios, the resistance increased with clog length. On the one hand, experiments at constant imposed pressure showed that the clog's permeability decreased with increased operating pressure, with no detectable changes in cell density as assessed through fluorescence imaging. On the other hand, backflush cycles resulted in an approximately four times higher permeability, associated with a significant nonmonotonic decrease in cell density with the operating pressure. Leveraging on our unique dual measurement of fluid flow and clog microstructure, our study offered enhanced insights into the intricate relationships between clog microstructure, permeability, and construction history. A better understanding of the fluid-structure interplay allowed us to develop a novel physical modeling of the flow in a soft and confined porous medium that challenged the empirical power-law description used in bioclogging theory by accurately replicating the measured permeability-pressure variations.- 28 March 2024
- Published by American Physical Society (APS) in Physical Review Fluids
- Vol. 9 (3) , 034202
Hydrodynamic resistance of a yeast clog
Bioclogging, the clogging of pores with living particles, is a complex process that involves various coupled mechanisms such as hydrodynamics and particle properties. The lack of sensitive methods to simultaneously measure the hydraulic resistance of a clog and the position of particles at high enough resolutions limits our understanding of this tight fluid-structure interplay. In this article, we explored bioclogging at the microscale level, where flow rates are typically extremely low (). We developed a highly sensitive method to precisely measure small flow rates ( error) with a low response time () while retaining the capability to image the structure of a fluorescently labeled yeast clog at high resolution. This method employed a microfluidic device with two identical channels: a first one for a yeast suspension and a second one for a colored culture medium. These channels merged into a single wide outlet channel, where the interface of the colored medium and the medium coming from the yeast clog could be monitored. As a yeast clog formed in the first channel, the displacement of the interface between the two media was imaged and compared to a pre-calibrated image database, quantifying the flow through the clog. We carried out two kinds of experiments to explore the fluid-clog interaction: filtration under constant operating pressure and filtration under oscillating operating pressure (backflush cycles). We found that in both scenarios, the resistance increased with clog length. On the one hand, experiments at constant imposed pressure showed that the clog's permeability decreased with increased operating pressure, with no detectable changes in cell density as assessed through fluorescence imaging. On the other hand, backflush cycles resulted in an approximately four times higher permeability, associated with a significant nonmonotonic decrease in cell density with the operating pressure. Leveraging on our unique dual measurement of fluid flow and clog microstructure, our study offered enhanced insights into the intricate relationships between clog microstructure, permeability, and construction history. A better understanding of the fluid-structure interplay allowed us to develop a novel physical modeling of the flow in a soft and confined porous medium that challenged the empirical power-law description used in bioclogging theory by accurately replicating the measured permeability-pressure variations.- Open Access
Parallel on-chip micropipettes enabling quantitative multiplexed characterization of vesicle mechanics and cell aggregates rheology
Micropipette aspiration (MPA) is one of the gold standards to quantify biological samples’ mechanical properties, which are crucial from the cell membrane scale to the multicellular tissue. However, relying on the manipulation of individual home-made glass pipettes, MPA suffers from low throughput and difficult automation. Here, we introduce the sliding insert micropipette aspiration (SIMPA) method, that permits parallelization and automation, thanks to the insertion of tubular pipettes, obtained by photolithography, within microfluidic channels. We show its application both at the lipid bilayer level, by probing vesicles to measure membrane bending and stretching moduli, and at the tissue level by quantifying the viscoelasticity of 3D cell aggregates. This approach opens the way to high-throughput, quantitative mechanical testing of many types of biological samples, from vesicles and individual cells to cell aggregates and explants, under dynamic physico-chemical stimuli.
Open AccessParallel on-chip micropipettes enabling quantitative multiplexed characterization of vesicle mechanics and cell aggregates rheology
Micropipette aspiration (MPA) is one of the gold standards to quantify biological samples’ mechanical properties, which are crucial from the cell membrane scale to the multicellular tissue. However, relying on the manipulation of individual home-made glass pipettes, MPA suffers from low throughput and difficult automation. Here, we introduce the sliding insert micropipette aspiration (SIMPA) method, that permits parallelization and automation, thanks to the insertion of tubular pipettes, obtained by photolithography, within microfluidic channels. We show its application both at the lipid bilayer level, by probing vesicles to measure membrane bending and stretching moduli, and at the tissue level by quantifying the viscoelasticity of 3D cell aggregates. This approach opens the way to high-throughput, quantitative mechanical testing of many types of biological samples, from vesicles and individual cells to cell aggregates and explants, under dynamic physico-chemical stimuli.
- 25 May 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 72
A microfluidics-assisted photopolymerization method for high-resolution multimaterial 3D printing
- 25 May 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 72
A microfluidics-assisted photopolymerization method for high-resolution multimaterial 3D printing
- 1 July 2022
- Published by AIP Publishing in Biomicrofluidics
- Vol. 16 (4) , 044111
Hybridization-based DNA biosensing with a limit of detection of 4 fM in 30 s using an electrohydrodynamic concentration module fabricated by grayscale lithography
Speeding up and enhancing the performances of nucleic acid biosensing technologies have remained drivers for innovation. Here, we optimize a fluorimetry-based technology for DNA detection based on the concentration of linear targets paired with probes. The concentration module consists of a microfluidic channel with the shape of a funnel in which we monitor a viscoelastic flow and a counter-electrophoretic force. We report that the technology performs better with a target longer than 100 nucleotides (nt) and a probe shorter than 30 nt. We also prove that the control of the funnel geometry in 2.5D using grayscale lithography enhances sensitivity by 100-fold in comparison to chips obtained by conventional photolithography. With these optimized settings, we demonstrate a limit of detection of 4 fM in 30 s and a detection range of more than five decades. This technology hence provides an excellent balance between sensitivity and time to result.
- 1 July 2022
- Published by AIP Publishing in Biomicrofluidics
- Vol. 16 (4) , 044111
Hybridization-based DNA biosensing with a limit of detection of 4 fM in 30 s using an electrohydrodynamic concentration module fabricated by grayscale lithography
Speeding up and enhancing the performances of nucleic acid biosensing technologies have remained drivers for innovation. Here, we optimize a fluorimetry-based technology for DNA detection based on the concentration of linear targets paired with probes. The concentration module consists of a microfluidic channel with the shape of a funnel in which we monitor a viscoelastic flow and a counter-electrophoretic force. We report that the technology performs better with a target longer than 100 nucleotides (nt) and a probe shorter than 30 nt. We also prove that the control of the funnel geometry in 2.5D using grayscale lithography enhances sensitivity by 100-fold in comparison to chips obtained by conventional photolithography. With these optimized settings, we demonstrate a limit of detection of 4 fM in 30 s and a detection range of more than five decades. This technology hence provides an excellent balance between sensitivity and time to result.
- 1 December 2021
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 603, 333-343
Wet spinning of a library of carbohydrate low molecular weight gels
- 1 December 2021
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 603, 333-343
Wet spinning of a library of carbohydrate low molecular weight gels
- Open Access
- 1 August 2020
- Published by Elsevier in Micro and Nano Engineering
- Vol. 8
Microfluidic characterization of biomimetic membrane mechanics with an on-chip micropipette
- 1 August 2020
- Published by Elsevier in Micro and Nano Engineering
- Vol. 8
Open AccessMicrofluidic characterization of biomimetic membrane mechanics with an on-chip micropipette
- Open Access
- 10 January 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
µLAS: Sizing of expanded trinucleotide repeats with femtomolar sensitivity in less than 5 minutes
We present µLAS, a lab-on-chip system that concentrates, separates, and detects DNA fragments in a single module. µLAS speeds up DNA size analysis in minutes using femtomolar amounts of amplified DNA. Here we tested the relevance of µLAS for sizing expanded trinucleotide repeats, which cause over 20 different neurological and neuromuscular disorders. Because the length of trinucleotide repeats correlates with the severity of the diseases, it is crucial to be able to size repeat tract length accurately and efficiently. Expanded trinucleotide repeats are however genetically unstable and difficult to amplify. Thus, the amount of amplified material to work with is often limited, making its analysis labor-intensive. We report the detection of heterogeneous allele lengths in 8 samples from myotonic dystrophy type 1 and Huntington disease patients with up to 750 CAG/CTG repeats in five minutes or less. The high sensitivity of the method allowed us to minimize the number of amplification cycles and thus reduce amplification artefacts without compromising the detection of the expanded allele. These results suggest that µLAS can speed up routine molecular biology applications of repetitive sequences and may improve the molecular diagnostic of expanded repeat disorders.
- 10 January 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
Open AccessµLAS: Sizing of expanded trinucleotide repeats with femtomolar sensitivity in less than 5 minutes
We present µLAS, a lab-on-chip system that concentrates, separates, and detects DNA fragments in a single module. µLAS speeds up DNA size analysis in minutes using femtomolar amounts of amplified DNA. Here we tested the relevance of µLAS for sizing expanded trinucleotide repeats, which cause over 20 different neurological and neuromuscular disorders. Because the length of trinucleotide repeats correlates with the severity of the diseases, it is crucial to be able to size repeat tract length accurately and efficiently. Expanded trinucleotide repeats are however genetically unstable and difficult to amplify. Thus, the amount of amplified material to work with is often limited, making its analysis labor-intensive. We report the detection of heterogeneous allele lengths in 8 samples from myotonic dystrophy type 1 and Huntington disease patients with up to 750 CAG/CTG repeats in five minutes or less. The high sensitivity of the method allowed us to minimize the number of amplification cycles and thus reduce amplification artefacts without compromising the detection of the expanded allele. These results suggest that µLAS can speed up routine molecular biology applications of repetitive sequences and may improve the molecular diagnostic of expanded repeat disorders.
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 274, 338-342
Nanofluidic fluorescence microscopy with integrated concentration gradient generation for one-shot parallel kinetic assays
- 1 November 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 274, 338-342
Nanofluidic fluorescence microscopy with integrated concentration gradient generation for one-shot parallel kinetic assays
- Open Access
- 20 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-7
Pore cross-talk in colloidal filtration
Blockage of pores by particles is found in many processes, including filtration and oil extraction. We present filtration experiments through a linear array of ten channels with one dimension which is sub-micron, through which a dilute dispersion of Brownian polystyrene spheres flows under the action of a fixed pressure drop. The growth rate of a clog formed by particles at a pore entrance systematically increases with the number of already saturated (entirely clogged) pores, indicating that there is an interaction or “cross-talk” between the pores. This observation is interpreted based on a phenomenological model, stating that a diffusive redistribution of particles occurs along the membrane, from clogged to free pores. This one-dimensional model could be extended to two-dimensional membranes.
- 20 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-7
Open AccessPore cross-talk in colloidal filtration
Blockage of pores by particles is found in many processes, including filtration and oil extraction. We present filtration experiments through a linear array of ten channels with one dimension which is sub-micron, through which a dilute dispersion of Brownian polystyrene spheres flows under the action of a fixed pressure drop. The growth rate of a clog formed by particles at a pore entrance systematically increases with the number of already saturated (entirely clogged) pores, indicating that there is an interaction or “cross-talk” between the pores. This observation is interpreted based on a phenomenological model, stating that a diffusive redistribution of particles occurs along the membrane, from clogged to free pores. This one-dimensional model could be extended to two-dimensional membranes.