A. M. Abdel Reheem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. M. Abdel Reheem has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ali Atta
Jouf University
5 shared publications H. El-Khabeary
Accelerators and Ion Sources Department, Nuclear Research Center, Egyptian Atomic Energy Authority, Cairo, Egypt
3 shared publicationsB. M. Alotaibi
Physics Department, College of Science, Princess Nourah Bint Abdulrahman University, P. O. Box 84428, Riyadh 11671, Saudi Arabia
2 shared publicationsHaifa A. Al-Yousef
Physics Department, College of Science, Princess Nourah Bint Abdulrahman University, P. O. Box 84428, Riyadh 11671, Saudi Arabia
2 shared publicationsM. M. Ahmed
Physics Department, Faculty of Science, Helwan University, Cairo, Egypt
2 shared publications- Mohamed Ibrahim Ahmed Abdel Maksoud
Radiation Physics Department, National Center for Radiation Research and Technology (NCRRT), Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt
2 shared publications
Latest Publications
- 12 August 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 32 (03)
ERRATUM: INFLUENCE OF ARGON IRRADIATION ON ELECTRICAL PROPERTIES OF PVA/NaI POLYMER COMPOSITES
- 12 August 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 32 (03)
ERRATUM: INFLUENCE OF ARGON IRRADIATION ON ELECTRICAL PROPERTIES OF PVA/NaI POLYMER COMPOSITES
- 9 August 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 33 (01)
STRUCTURAL CHANGES IN CORTICAL BONE AFTER BOMBARDMENT WITH LOW-ENERGY HYDROGEN IONS
Radiobiological studies focused mainly on tracking the effects of photons (X and gamma rays) and high-energy charged particles over low energy ions, which raises interest in studying their biological effects. Therefore, the aim of this study is to investigate the interaction of low-energy hydrogen ions beam with xcortical bovine bone as a biological model. A hydrogen ions beam was used to bombard cortical bone with different fluences; 45, 70 and [ ][ ]ions/cm 2 at low energy of 5[ ]keV. The interaction of hydrogen ions with cortical bone was estimated theoretically by the SRIM/TRIM code. The obtained results showed that the average distribution range and the maximum depth for 5[ ]keV hydrogen ions are 91 and 150[ ]nm respectively. The energy losses from incident ions are 4.45[ ]keV for ionization, 170[ ]eV for phonons and 18[ ]eV for vacancies. Also, the energy losses from the recoil atoms are 119[ ]eV for ionization, 234[ ]eV for phonons and 8[ ]eV for vacancies. At the same time, the effect of low-energy hydrogen ions bombardment on the structure of bone was studied by X-ray diffraction (XRD) and FTIR.
- 9 August 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 33 (01)
STRUCTURAL CHANGES IN CORTICAL BONE AFTER BOMBARDMENT WITH LOW-ENERGY HYDROGEN IONS
Radiobiological studies focused mainly on tracking the effects of photons (X and gamma rays) and high-energy charged particles over low energy ions, which raises interest in studying their biological effects. Therefore, the aim of this study is to investigate the interaction of low-energy hydrogen ions beam with xcortical bovine bone as a biological model. A hydrogen ions beam was used to bombard cortical bone with different fluences; 45, 70 and [ ][ ]ions/cm 2 at low energy of 5[ ]keV. The interaction of hydrogen ions with cortical bone was estimated theoretically by the SRIM/TRIM code. The obtained results showed that the average distribution range and the maximum depth for 5[ ]keV hydrogen ions are 91 and 150[ ]nm respectively. The energy losses from incident ions are 4.45[ ]keV for ionization, 170[ ]eV for phonons and 18[ ]eV for vacancies. Also, the energy losses from the recoil atoms are 119[ ]eV for ionization, 234[ ]eV for phonons and 8[ ]eV for vacancies. At the same time, the effect of low-energy hydrogen ions bombardment on the structure of bone was studied by X-ray diffraction (XRD) and FTIR.
- 15 November 2023
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 31 (04)
INFLUENCE OF ARGON IRRADIATION ON ELECTRICAL PROPERTIES OF PVA/NaI POLYMER COMPOSITES
In this work, PVA/NaI consisting of polyvinyl alcohol (PVA) and sodium iodine (NaI) is irradiated using argon at fluence (45×10[ ], 90×10[ ], and 135×10[ ] ion/cm2). The structure is investigated by XRD technique. The influence of argon ion is studied theoretically by SRIM/TRIM simulations. The target vacancies are recorded 46/ion, target displacements are 47/ion, and the replacements atoms are 1/ion. Also, the dielectric properties were determined in the frequency of 100 Hz to 5 MHz. With an average fluence 90×10[ ] ions/cm2, electrical conductivity and dielectric constants have increased to twice their initial value. Additionally, after being exposed to an ion beam, the dielectric loss is reduced to around half of its original value. For both the control and irradiation samples, the attenuation and half layers were estimated. The dielectric characteristics of the irradiated samples were found to improve. Numerous uses, including energy storage and batteries, are rendered possible by these results.
- 15 November 2023
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 31 (04)
INFLUENCE OF ARGON IRRADIATION ON ELECTRICAL PROPERTIES OF PVA/NaI POLYMER COMPOSITES
In this work, PVA/NaI consisting of polyvinyl alcohol (PVA) and sodium iodine (NaI) is irradiated using argon at fluence (45×10[ ], 90×10[ ], and 135×10[ ] ion/cm2). The structure is investigated by XRD technique. The influence of argon ion is studied theoretically by SRIM/TRIM simulations. The target vacancies are recorded 46/ion, target displacements are 47/ion, and the replacements atoms are 1/ion. Also, the dielectric properties were determined in the frequency of 100 Hz to 5 MHz. With an average fluence 90×10[ ] ions/cm2, electrical conductivity and dielectric constants have increased to twice their initial value. Additionally, after being exposed to an ion beam, the dielectric loss is reduced to around half of its original value. For both the control and irradiation samples, the attenuation and half layers were estimated. The dielectric characteristics of the irradiated samples were found to improve. Numerous uses, including energy storage and batteries, are rendered possible by these results.
- Open Access
- 18 September 2022
- Published by Egyptian Knowledge Bank in Egyptian Journal of Radiation Sciences and Applications
Modification of Unfinished Textiles by Cu Deposition Developed by Cold Cathode Ion Source for Antimicrobial Application
The main goal of this work is to investigate the influence of depositing copper film on different unfinished textiles, namely; polyester, cotton and polyester/cotton, on their antimicrobial activity. Ion beam of argon gas is used for sputtering of copper target to deposit a thin film of copper on the textiles surface. The samples are characterized by SEM, FTIR, and XRD. The results show that copper nanoparticles are smoothly deposited onto the surface with no change on the chemical or the physical structure of the textiles. Ac conductivity was measured in the frequency range 50Hz-5MHz and shows slight increase with Cu nanoparticles deposition. The antimicrobial activity test shows an enhancement of the textiles ability to inhibit gram-positive S. aureus and gram-negative E. coli after copper deposition and the inhibition is higher for E. coli. Also, the results show the highest reduction ability of modified cotton sample for both types of bacteria.
- 18 September 2022
- Published by Egyptian Knowledge Bank in Egyptian Journal of Radiation Sciences and Applications
Open AccessModification of Unfinished Textiles by Cu Deposition Developed by Cold Cathode Ion Source for Antimicrobial Application
The main goal of this work is to investigate the influence of depositing copper film on different unfinished textiles, namely; polyester, cotton and polyester/cotton, on their antimicrobial activity. Ion beam of argon gas is used for sputtering of copper target to deposit a thin film of copper on the textiles surface. The samples are characterized by SEM, FTIR, and XRD. The results show that copper nanoparticles are smoothly deposited onto the surface with no change on the chemical or the physical structure of the textiles. Ac conductivity was measured in the frequency range 50Hz-5MHz and shows slight increase with Cu nanoparticles deposition. The antimicrobial activity test shows an enhancement of the textiles ability to inhibit gram-positive S. aureus and gram-negative E. coli after copper deposition and the inhibition is higher for E. coli. Also, the results show the highest reduction ability of modified cotton sample for both types of bacteria.
- 2 June 2021
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 41 (5) , 1535-1546
Optimization and Characterization of Modified Cold Grid Cathode Penning Ion Source
- 2 June 2021
- Published by Springer Nature in Plasma Chemistry and Plasma Processing
- Vol. 41 (5) , 1535-1546
Optimization and Characterization of Modified Cold Grid Cathode Penning Ion Source
- 10 April 2017
- Published by Walter de Gruyter GmbH in International Polymer Processing
- Vol. 32 (2) , 174-182
Ion Etching Induced Surface Patterns of Blend Polymer (Poly Ethylene Glycol – Poly Methyl Methacrylate) Irradiated with Gamma Rays
The pattern surface structure of a thin blend polymer film of Poly methyl methacrylate (PMMA) – Poly ethylene glycol (PEG) induced by Ar+ ion etching (5 keV) has been investigated by scanning electron microscopy. Blend polymer films have been obtained consisting of a hydrophilic PEG and a hydrophobic PMMA distributed in co-continuous phases. Four different compositions of the two polymers are dissolved in chloroform and irradiated with gamma rays (60Co) at 20 kGy to produce transparent films of blend polymer PMMA-PEG after casting. Self-assembled of PMMA-PEG film is obtained because of the high contrast between the two polymers. Ion-polymer interaction with a hydrophilic polymer (Ar+ +PEG) rather than the high etch resistance of hydrophobic polymer (Ar+ −PMMA) was observed. The results are discussed in terms of significant destruction of bonds in the blend polymer films as a result of which one polymer undergoes rapid dissociation rather than the other one. This means that etching with Ar+ ions of the PMMA domains are stable and PEG can be selective. The ATR-FTIR spectrum shows the absence of hydrogen bonds and XRD/DSC curves show the crystanility of PMMA depending on the PEG contents and gamma radiation effect, irradiated blend polymer PMMA/PEG has shown more resistant at thermal degradation than irradiated PMMA. This indicates that the PEG contents have an effect on the thermal stability of PMMA/PEG as detected by TGA. Finally, the pattern surface of irradiated blend polymer (PMMA-2%PEG) was plated with two coaxial layers subsequently of copper (Cu) and silver (Ag) using sputter technique.
- 10 April 2017
- Published by Walter de Gruyter GmbH in International Polymer Processing
- Vol. 32 (2) , 174-182
Ion Etching Induced Surface Patterns of Blend Polymer (Poly Ethylene Glycol – Poly Methyl Methacrylate) Irradiated with Gamma Rays
The pattern surface structure of a thin blend polymer film of Poly methyl methacrylate (PMMA) – Poly ethylene glycol (PEG) induced by Ar+ ion etching (5 keV) has been investigated by scanning electron microscopy. Blend polymer films have been obtained consisting of a hydrophilic PEG and a hydrophobic PMMA distributed in co-continuous phases. Four different compositions of the two polymers are dissolved in chloroform and irradiated with gamma rays (60Co) at 20 kGy to produce transparent films of blend polymer PMMA-PEG after casting. Self-assembled of PMMA-PEG film is obtained because of the high contrast between the two polymers. Ion-polymer interaction with a hydrophilic polymer (Ar+ +PEG) rather than the high etch resistance of hydrophobic polymer (Ar+ −PMMA) was observed. The results are discussed in terms of significant destruction of bonds in the blend polymer films as a result of which one polymer undergoes rapid dissociation rather than the other one. This means that etching with Ar+ ions of the PMMA domains are stable and PEG can be selective. The ATR-FTIR spectrum shows the absence of hydrogen bonds and XRD/DSC curves show the crystanility of PMMA depending on the PEG contents and gamma radiation effect, irradiated blend polymer PMMA/PEG has shown more resistant at thermal degradation than irradiated PMMA. This indicates that the PEG contents have an effect on the thermal stability of PMMA/PEG as detected by TGA. Finally, the pattern surface of irradiated blend polymer (PMMA-2%PEG) was plated with two coaxial layers subsequently of copper (Cu) and silver (Ag) using sputter technique.
- 30 March 2017
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 24 (03)
OPTICAL AND ELECTRICAL PROPERTIES OF ARGON ION BEAM IRRADIATED PVA/Ag NANOCOMPOSITES
- 30 March 2017
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 24 (03)
OPTICAL AND ELECTRICAL PROPERTIES OF ARGON ION BEAM IRRADIATED PVA/Ag NANOCOMPOSITES
- 30 March 2017
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 24 (03)
IRRADIATION AND SILVER DEPOSITION FOR IMPROVEMENT OF NASOPHARYNGEAL AIRWAY MEDICAL DEVICE PROPERTIES
The thermal and mechanical properties of nasopharyngeal airway (NPA) samples are improved by irradiation using 4[Formula: see text]keV oxygen and nitrogen ion beams with different ion fluences varying from [Formula: see text] ions/cm2to [Formula: see text] ions/cm2. The thermal stability of NPA medical device increases with increasing nitrogen and oxygen ion fluences. The tensile strength increased from 48[Formula: see text]MPa for unirradiated sample to 74[Formula: see text]MPa for samples irradiated with nitrogen and to 58[Formula: see text]MPa for samples irradiated with oxygen ion, while the elongation at break decreases for irradiated samples. Silver thin films are deposited on NPA medical device samples using 4[Formula: see text]keV argon ion beam. The XRD spectra demonstrated that silver nanoparticles are deposited on NPA medical device substrate. The effects of Ag thin film on gram-positive and gram-negative bacteria are studied.
- 30 March 2017
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 24 (03)
IRRADIATION AND SILVER DEPOSITION FOR IMPROVEMENT OF NASOPHARYNGEAL AIRWAY MEDICAL DEVICE PROPERTIES
The thermal and mechanical properties of nasopharyngeal airway (NPA) samples are improved by irradiation using 4[Formula: see text]keV oxygen and nitrogen ion beams with different ion fluences varying from [Formula: see text] ions/cm2to [Formula: see text] ions/cm2. The thermal stability of NPA medical device increases with increasing nitrogen and oxygen ion fluences. The tensile strength increased from 48[Formula: see text]MPa for unirradiated sample to 74[Formula: see text]MPa for samples irradiated with nitrogen and to 58[Formula: see text]MPa for samples irradiated with oxygen ion, while the elongation at break decreases for irradiated samples. Silver thin films are deposited on NPA medical device samples using 4[Formula: see text]keV argon ion beam. The XRD spectra demonstrated that silver nanoparticles are deposited on NPA medical device substrate. The effects of Ag thin film on gram-positive and gram-negative bacteria are studied.
- 1 October 2016
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 127, 269-275
Low energy ion beam induced changes in structural and thermal properties of polycarbonate
- 1 October 2016
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 127, 269-275
Low energy ion beam induced changes in structural and thermal properties of polycarbonate
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 083302
Verification of high efficient broad beam cold cathode ion source
An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.
- 1 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (8) , 083302
Verification of high efficient broad beam cold cathode ion source
An improved form of cold cathode ion source has been designed and constructed. It consists of stainless steel hollow cylinder anode and stainless steel cathode disc, which are separated by a Teflon flange. The electrical discharge and output characteristics have been measured at different pressures using argon, nitrogen, and oxygen gases. The ion exit aperture shape and optimum distance between ion collector plate and cathode disc are studied. The stable discharge current and maximum output ion beam current have been obtained using grid exit aperture. It was found that the optimum distance between ion collector plate and ion exit aperture is equal to 6.25 cm. The cold cathode ion source is used to deposit aluminum coating layer on AZ31 magnesium alloy using argon ion beam current which equals 600 μA. Scanning electron microscope and X-ray diffraction techniques used for characterizing samples before and after aluminum deposition.