Kevin L. Braun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kevin L. Braun has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Craig A. Aspinwall
Department of Chemistry and Biochemistry, University of Arizona, Tucson, Arizona 85721, United States
2 shared publications - Christopher Kemper Ober
Department of Materials Science and Engineering Cornell University Ithaca New York USA
1 shared publication Clare S. Harper
Department of Chemistry, Beloit College, Beloit, Wisconsin 53511, United States
1 shared publication- Elyssia S. Gallagher
Baylor University
1 shared publication - Facundo M. Fernandez
Georgia Institute of Technology
1 shared publication Faith V. Macdonald
Department of Chemistry, Beloit College, Beloit, Wisconsin 53511, United States
1 shared publication
Latest Publications
- 1 January 2019
- Published by American Chemical Society (ACS)
- p. 61-78
Enhancing the General Chemistry Laboratory Using Integrated Projects Based on Real-World Questions
- 1 January 2019
- Published by American Chemical Society (ACS)
- p. 61-78
Enhancing the General Chemistry Laboratory Using Integrated Projects Based on Real-World Questions
- 21 July 2017
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 94 (9) , 1309-1313
Lipid Residue Analysis of Archaeological Pottery: An Introductory Laboratory Experiment in Archaeological Chemistry
- 21 July 2017
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 94 (9) , 1309-1313
Lipid Residue Analysis of Archaeological Pottery: An Introductory Laboratory Experiment in Archaeological Chemistry
- 22 August 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (18) , 2903-2910
Online photolytic optical gating of caged fluorophores in capillary zone electrophoresis utilizing an ultraviolet light‐emitting diode
Photolytic optical gating (POG) facilitates rapid, on‐line and highly sensitive analyses, though POG utilizes UV lasers for sample injection. We present a low‐cost, more portable alternative, employing an ultraviolet light‐emitting diode (UV‐LED) array to inject caged fluorescent dyes via photolysis. Utilizing the UV‐LED array, labeled amino acids were injected with nanomolar limits of detection (270 ± 30 nM and 250 ± 30 nM for arginine and citrulline, respectively). When normalized for the difference in light intensity, the UV‐LED array provides comparable sensitivity to POG utilizing UV lasers. Additionally, the UV‐LED array yielded sufficient beam quality and stability to facilitate coupling with a Hadamard transform, resulting in increased sensitivity. This work shows, for the first time, the use of an UV‐LED for online POG with comparable sensitivity to conventional laser sources but at a lower cost.
- 22 August 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (18) , 2903-2910
Online photolytic optical gating of caged fluorophores in capillary zone electrophoresis utilizing an ultraviolet light‐emitting diode
Photolytic optical gating (POG) facilitates rapid, on‐line and highly sensitive analyses, though POG utilizes UV lasers for sample injection. We present a low‐cost, more portable alternative, employing an ultraviolet light‐emitting diode (UV‐LED) array to inject caged fluorescent dyes via photolysis. Utilizing the UV‐LED array, labeled amino acids were injected with nanomolar limits of detection (270 ± 30 nM and 250 ± 30 nM for arginine and citrulline, respectively). When normalized for the difference in light intensity, the UV‐LED array provides comparable sensitivity to POG utilizing UV lasers. Additionally, the UV‐LED array yielded sufficient beam quality and stability to facilitate coupling with a Hadamard transform, resulting in increased sensitivity. This work shows, for the first time, the use of an UV‐LED for online POG with comparable sensitivity to conventional laser sources but at a lower cost.
- 25 January 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (5) , 1628-1635
Fast Hadamard Transform Capillary Electrophoresis for On-Line, Time-Resolved Chemical Monitoring
We report a new approach for collecting and deconvoluting the data in Hadamard transform capillary electrophoresis, referred to as fast Hadamard transform capillary electrophoresis (fHTCE). Using fHTCE, total analysis times can be reduced by up to 48% per multiplexed separation compared to conventional Hadamard transform capillary electrophoresis (cHTCE) while providing comparable signal-to-noise ratio enhancements. In fHTCE, the sample is injected following a pseudorandom pulsing sequence derived from the first row of a simplex matrix (S-matrix) in contrast to cHTCE, which utilizes a sequence of twice the length. In addition to the temporal savings provided by fHTCE, a 50% reduction in sample consumption is also realized due to the decreased number of sample injections. We have applied fHTCE to the analysis of mixtures of neurotransmitters and related compounds to yield improved signal-to-noise ratios with a total analysis time under 10 s. In addition, we demonstrate the capability of fHTCE to perform time-resolved monitoring of changes in the concentration of model neurochemical compounds.
- 25 January 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (5) , 1628-1635
Fast Hadamard Transform Capillary Electrophoresis for On-Line, Time-Resolved Chemical Monitoring
We report a new approach for collecting and deconvoluting the data in Hadamard transform capillary electrophoresis, referred to as fast Hadamard transform capillary electrophoresis (fHTCE). Using fHTCE, total analysis times can be reduced by up to 48% per multiplexed separation compared to conventional Hadamard transform capillary electrophoresis (cHTCE) while providing comparable signal-to-noise ratio enhancements. In fHTCE, the sample is injected following a pseudorandom pulsing sequence derived from the first row of a simplex matrix (S-matrix) in contrast to cHTCE, which utilizes a sequence of twice the length. In addition to the temporal savings provided by fHTCE, a 50% reduction in sample consumption is also realized due to the decreased number of sample injections. We have applied fHTCE to the analysis of mixtures of neurotransmitters and related compounds to yield improved signal-to-noise ratios with a total analysis time under 10 s. In addition, we demonstrate the capability of fHTCE to perform time-resolved monitoring of changes in the concentration of model neurochemical compounds.
- Top Cited Papers
- 10 May 2002
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 296 (5570) , 1106-1109
An Efficient Two-Photon-Generated Photoacid Applied to Positive-Tone 3D Microfabrication
A two-photon–activatable photoacid generator, based on a bis [(diarylamino) styryl]benzene core with covalently attached sulfonium moieties, has been synthesized. The photoacid generator has both a large two-photon absorption cross section (δ = 690 × 10 −50 centimeter 4 second per photon) and a high quantum yield for the photochemical generation of acid (φ H + = 0.5). Under near-infrared laser irradiation, the molecule produces acid after two-photon excitation and initiates the polymerization of epoxides at an incident intensity that is one to two orders of magnitude lower than that needed for conventional ultraviolet-sensitive initiators. This photoacid generator was used in conjunction with a positive-tone chemically amplified resist for the fabrication of a three-dimensional (3D) microchannel structure.
- 10 May 2002
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 296 (5570) , 1106-1109
Top Cited PapersAn Efficient Two-Photon-Generated Photoacid Applied to Positive-Tone 3D Microfabrication
A two-photon–activatable photoacid generator, based on a bis [(diarylamino) styryl]benzene core with covalently attached sulfonium moieties, has been synthesized. The photoacid generator has both a large two-photon absorption cross section (δ = 690 × 10 −50 centimeter 4 second per photon) and a high quantum yield for the photochemical generation of acid (φ H + = 0.5). Under near-infrared laser irradiation, the molecule produces acid after two-photon excitation and initiates the polymerization of epoxides at an incident intensity that is one to two orders of magnitude lower than that needed for conventional ultraviolet-sensitive initiators. This photoacid generator was used in conjunction with a positive-tone chemically amplified resist for the fabrication of a three-dimensional (3D) microchannel structure.