Jong Il Rhee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jong Il Rhee has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Hong Dinh Duong
12 shared publicationsOk-Jae Sohn
11 shared publications- Hong Dinh Duong
School of Chemical Engineering and Research Center for Biophotonics, Chonnam National University, Yong-Bong Ro 77, Gwangju 61186, Korea
4 shared publications Chun-Kwang Kim
School of Applied Chemical Engineering, Chonnam National University, Gwangju 500-757, Republic of Korea
3 shared publicationsSung-Duk Oh
3 shared publicationsJuyeon Kim
2 shared publications
Latest Publications
- Open Access
- 31 March 2024
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 33 (2) , 70-77
Development of a Fluorescent Sensor Based on Resazurin and Hydrotalcite for the Determination of Ethanol in Alcoholic Beverages
- 31 March 2024
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 33 (2) , 70-77
Open AccessDevelopment of a Fluorescent Sensor Based on Resazurin and Hydrotalcite for the Determination of Ethanol in Alcoholic Beverages
- 2 May 2023
- Published by Elsevier in Optical Materials
- Vol. 140, 113847
Preparation and characterization of optical temperature-sensing membranes based on various fluorescent material-doped polyacrylonitrile nanoflowers
- 2 May 2023
- Published by Elsevier in Optical Materials
- Vol. 140, 113847
Preparation and characterization of optical temperature-sensing membranes based on various fluorescent material-doped polyacrylonitrile nanoflowers
- Open Access
- 11 April 2023
- Published by Elsevier in Polymer Testing
- Vol. 122
Preparation and characterization of electrospun fluorescent fiber mats as temperature sensors using various polymers
- 11 April 2023
- Published by Elsevier in Polymer Testing
- Vol. 122
Open AccessPreparation and characterization of electrospun fluorescent fiber mats as temperature sensors using various polymers
- 15 February 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (2) , 361-371
Improving Indigo Reduction to Leuco-Indigo by Glucose by Means of Direct Electron Transfer and Electron Carriers of Enzymes
- 15 February 2023
- Published by Springer Nature in Fibers and Polymers
- Vol. 24 (2) , 361-371
Improving Indigo Reduction to Leuco-Indigo by Glucose by Means of Direct Electron Transfer and Electron Carriers of Enzymes
- 31 December 2021
- Published by Korean Society for Biotechnology and Bioengineering in KSBB Journal
- Vol. 36 (4) , 296-306
Preparation and Characterization of Enzyme-immobilized Fluorescent Magnetic Iron Oxide Nanoparticles for the Detection of Glucose and Urea
Sumin Yang, Juyeon Kim, and Jong Il Rhee*. Korean Society for Biotechnology and Bioengineering Journal 2021;36:296-306. https://doi.org/10.7841/ksbbj.2021.36.4.296
- 31 December 2021
- Published by Korean Society for Biotechnology and Bioengineering in KSBB Journal
- Vol. 36 (4) , 296-306
Preparation and Characterization of Enzyme-immobilized Fluorescent Magnetic Iron Oxide Nanoparticles for the Detection of Glucose and Urea
Sumin Yang, Juyeon Kim, and Jong Il Rhee*. Korean Society for Biotechnology and Bioengineering Journal 2021;36:296-306. https://doi.org/10.7841/ksbbj.2021.36.4.296
- Open Access
- 25 June 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (7) , 208
Ratiometric Fluorescent Biosensors for Glucose and Lactate Using an Oxygen-Sensing Membrane
In this study, ratiometric fluorescent glucose and lactate biosensors were developed using a ratiometric fluorescent oxygen-sensing membrane immobilized with glucose oxidase (GOD) or lactate oxidase (LOX). Herein, the ratiometric fluorescent oxygen-sensing membrane was fabricated with the ratio of two emission wavelengths of platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) doped in polystyrene particles and coumarin 6 (C6) captured into silica particles. The operation mechanism of the sensing membranes was based on (i) the fluorescence quenching effect of the PtP dye by oxygen molecules, and (ii) the consumption of oxygen levels in the glucose or lactate oxidation reactions under the catalysis of GOD or LOX. The ratiometric fluorescent glucose-sensing membrane showed high sensitivity to glucose in the range of 0.1–2 mM, with a limit of detection (LOD) of 0.031 mM, whereas the ratiometric fluorescent lactate-sensing membrane showed the linear detection range of 0.1–0.8 mM, with an LOD of 0.06 mM. These sensing membranes also showed good selectivity, fast reversibility, and stability over long-term use. They were applied to detect glucose and lactate in artificial human serum, and they provided reliable measurement results.
- 25 June 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (7) , 208
Open AccessRatiometric Fluorescent Biosensors for Glucose and Lactate Using an Oxygen-Sensing Membrane
In this study, ratiometric fluorescent glucose and lactate biosensors were developed using a ratiometric fluorescent oxygen-sensing membrane immobilized with glucose oxidase (GOD) or lactate oxidase (LOX). Herein, the ratiometric fluorescent oxygen-sensing membrane was fabricated with the ratio of two emission wavelengths of platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) doped in polystyrene particles and coumarin 6 (C6) captured into silica particles. The operation mechanism of the sensing membranes was based on (i) the fluorescence quenching effect of the PtP dye by oxygen molecules, and (ii) the consumption of oxygen levels in the glucose or lactate oxidation reactions under the catalysis of GOD or LOX. The ratiometric fluorescent glucose-sensing membrane showed high sensitivity to glucose in the range of 0.1–2 mM, with a limit of detection (LOD) of 0.031 mM, whereas the ratiometric fluorescent lactate-sensing membrane showed the linear detection range of 0.1–0.8 mM, with an LOD of 0.06 mM. These sensing membranes also showed good selectivity, fast reversibility, and stability over long-term use. They were applied to detect glucose and lactate in artificial human serum, and they provided reliable measurement results.
- Open Access
- 13 October 2020
- Published by MDPI AG in Preprints.org
Fluorescence Immunoassays Using CdSe/ZnS Core/Shell Quantum Dots for the Determination of Progesterone in Human Serum
In this study, two heterogeneous fluorescence immunoassays using CdSe/ZnS quantum dot (QD) to label anti-progesterone antibody (P4Ab) for the determination of progesterone (P4) were performed in the wells of a 96-well microtiter plate. First, P4Ab was conjugated to hydrophilic CdSe/ZnS QDs via ethyl-3-(dimethylaminopropyl) carbodiimide(EDC)-N-hydroxysuccinimide) chemistry(NHS) (QDs-P4Ab conjugates). The QDs-P4Ab conjugate was employed as a second antibody in a sandwich assay, where the P4Ab was immobilized onto the 3-aminopropyltrimethoxysilane (APTMS) sol-gel membrane of the wells of a 96-well microtiter plate, and P4 was bound between the immobilized P4Ab and the QDs-P4Ab conjugate. In this assay, the fluorescence intensity of the QDs increased with increasing P4 concentrations. This assay had a detection limit of 553.9 pg/ml and a sensitivity of 18,251.96 pg/ml with a linear range of 2,184.6 – 117,082 pg/ml. In the direct binding assay, P4 was directly bound to the QDs-P4Ab conjugates immobilized onto the APTMS sol-gel membrane of the wells of a 96-well microtiter plate. In this direct binding assay the fluorescence intensity of the QDs decreased with increasing P4 concentrations, and this assay had a linear range of 28.95 – 26,607.7 pg/ml with a detection limit of 3.32 pg/ml and a sensitivity of 987.24 pg/ml. These fluorescence immunoassays have been successfully applied for the determination of P4 in real human serum, and the results were well correlated with those of a certified radioimmunoassay (RIA) method.
- 13 October 2020
- Published by MDPI AG in Preprints.org
Open AccessFluorescence Immunoassays Using CdSe/ZnS Core/Shell Quantum Dots for the Determination of Progesterone in Human Serum
In this study, two heterogeneous fluorescence immunoassays using CdSe/ZnS quantum dot (QD) to label anti-progesterone antibody (P4Ab) for the determination of progesterone (P4) were performed in the wells of a 96-well microtiter plate. First, P4Ab was conjugated to hydrophilic CdSe/ZnS QDs via ethyl-3-(dimethylaminopropyl) carbodiimide(EDC)-N-hydroxysuccinimide) chemistry(NHS) (QDs-P4Ab conjugates). The QDs-P4Ab conjugate was employed as a second antibody in a sandwich assay, where the P4Ab was immobilized onto the 3-aminopropyltrimethoxysilane (APTMS) sol-gel membrane of the wells of a 96-well microtiter plate, and P4 was bound between the immobilized P4Ab and the QDs-P4Ab conjugate. In this assay, the fluorescence intensity of the QDs increased with increasing P4 concentrations. This assay had a detection limit of 553.9 pg/ml and a sensitivity of 18,251.96 pg/ml with a linear range of 2,184.6 – 117,082 pg/ml. In the direct binding assay, P4 was directly bound to the QDs-P4Ab conjugates immobilized onto the APTMS sol-gel membrane of the wells of a 96-well microtiter plate. In this direct binding assay the fluorescence intensity of the QDs decreased with increasing P4 concentrations, and this assay had a linear range of 28.95 – 26,607.7 pg/ml with a detection limit of 3.32 pg/ml and a sensitivity of 987.24 pg/ml. These fluorescence immunoassays have been successfully applied for the determination of P4 in real human serum, and the results were well correlated with those of a certified radioimmunoassay (RIA) method.
- Open Access
- 29 July 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (8) , 86
Development of a Ratiometric Fluorescent Glucose Sensor Using an Oxygen-Sensing Membrane Immobilized with Glucose Oxidase for the Detection of Glucose in Tears
Glucose concentration is an important parameter in biomedicine since glucose is involved in many metabolic pathways in organisms. Many methods for glucose detection have been developed for use in various applications, particularly in the field of healthcare in diabetics. In this study, ratiometric fluorescent glucose-sensing membranes were fabricated based on the oxygen levels consumed in the glucose oxidation reaction under the catalysis of glucose oxidase (GOD). The oxygen concentration was measured through the fluorescence quenching effect of an oxygen-sensitive fluorescent dye like platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) by oxygen molecules. Coumarin 6 (C6) was used as a reference dye in the ratiometric fluorescence measurements. The glucose-sensing membrane consisted of two layers: The first layer was the oxygen-sensing membrane containing polystyrene particles (PS) doped with PtP and C6 (e.g., PS@C6^PtP) in a sol–gel matrix of aminopropyltrimethoxysilane and glycidoxypropyltrimethoxysilane (GA). The second layer was made by immobilizing GOD onto one of three supporting polymers over the first layer. These glucose-sensing membranes were characterized in terms of their response, reversibility, interferences, and stability. They showed a wide detection range to glucose concentration in the range of 0.1 to 10 mM, but high sensitivity with a linear detection range of 0.1 to 2 mM glucose. This stable and sensitive ratiometric fluorescent glucose biosensor provides a reliable way to determine low glucose concentrations in blood serum by measuring tear glucose.
- 29 July 2020
- Published by MDPI AG in Biosensors
- Vol. 10 (8) , 86
Open AccessDevelopment of a Ratiometric Fluorescent Glucose Sensor Using an Oxygen-Sensing Membrane Immobilized with Glucose Oxidase for the Detection of Glucose in Tears
Glucose concentration is an important parameter in biomedicine since glucose is involved in many metabolic pathways in organisms. Many methods for glucose detection have been developed for use in various applications, particularly in the field of healthcare in diabetics. In this study, ratiometric fluorescent glucose-sensing membranes were fabricated based on the oxygen levels consumed in the glucose oxidation reaction under the catalysis of glucose oxidase (GOD). The oxygen concentration was measured through the fluorescence quenching effect of an oxygen-sensitive fluorescent dye like platinum meso-tetra (pentafluorophenyl) porphyrin (PtP) by oxygen molecules. Coumarin 6 (C6) was used as a reference dye in the ratiometric fluorescence measurements. The glucose-sensing membrane consisted of two layers: The first layer was the oxygen-sensing membrane containing polystyrene particles (PS) doped with PtP and C6 (e.g., PS@C6^PtP) in a sol–gel matrix of aminopropyltrimethoxysilane and glycidoxypropyltrimethoxysilane (GA). The second layer was made by immobilizing GOD onto one of three supporting polymers over the first layer. These glucose-sensing membranes were characterized in terms of their response, reversibility, interferences, and stability. They showed a wide detection range to glucose concentration in the range of 0.1 to 10 mM, but high sensitivity with a linear detection range of 0.1 to 2 mM glucose. This stable and sensitive ratiometric fluorescent glucose biosensor provides a reliable way to determine low glucose concentrations in blood serum by measuring tear glucose.
- 1 February 2020
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 107, 110323
Development of novel optical pH sensors based on coumarin 6 and nile blue A encapsulated in resin particles and specific support materials
- 1 February 2020
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 107, 110323
Development of novel optical pH sensors based on coumarin 6 and nile blue A encapsulated in resin particles and specific support materials
- Open Access
Development of Ratiometric Fluorescence Sensors Based on CdSe/ZnS Quantum Dots for the Detection of Hydrogen Peroxide
In this study, carboxyl group functionalized-CdSe/ZnS quantum dots (QDs) and aminofluorescein (AF)-encapsulated polymer particles were synthesized and immobilized to a sol–gel mixture of glycidoxypropyl trimethoxysilane (GPTMS) and aminopropyl trimethoxysilane (APTMS) for the fabrication of a hydrogen peroxide-sensing membrane. CdSe/ZnS QDs were used for the redox reaction of hydrogen peroxide (H2O2) via a reductive pathway by transferring electrons to the acceptor that led to fluorescence quenching of QDs, while AF was used as a reference dye. Herein, the ratiometric fluorescence intensity of CdSe/ZnS QDs and AF was proportional to the concentration of hydrogen peroxide. The fluorescence membrane (i.e., QD–AF membrane) could detect hydrogen peroxide in linear detection ranges from 0.1 to 1.0 mM with a detection limit (LOD) of 0.016 mM and from 1.0 to 10 mM with an LOD of 0.058 mM. The sensitivity of the QD–AF membrane was increased by immobilizing horseradish peroxidase (HRP) over the surface of the QD–AF membrane (i.e., HRP–QD–AF membrane). The HRP–QD–AF membrane had an LOD of 0.011 mM for 0.1–1 mM H2O2 and an LOD of 0.068 mM for 1–10 mM H2O2. It showed higher sensitivity than the QD–AF membrane only, although both membranes had good selectivity. The HRP–QD–AF membrane could be applied to determine the concentration of hydrogen peroxide in wastewater, while the QD–AF membrane could be employed for the detection of α-ketobutyrate.
Open AccessDevelopment of Ratiometric Fluorescence Sensors Based on CdSe/ZnS Quantum Dots for the Detection of Hydrogen Peroxide
In this study, carboxyl group functionalized-CdSe/ZnS quantum dots (QDs) and aminofluorescein (AF)-encapsulated polymer particles were synthesized and immobilized to a sol–gel mixture of glycidoxypropyl trimethoxysilane (GPTMS) and aminopropyl trimethoxysilane (APTMS) for the fabrication of a hydrogen peroxide-sensing membrane. CdSe/ZnS QDs were used for the redox reaction of hydrogen peroxide (H2O2) via a reductive pathway by transferring electrons to the acceptor that led to fluorescence quenching of QDs, while AF was used as a reference dye. Herein, the ratiometric fluorescence intensity of CdSe/ZnS QDs and AF was proportional to the concentration of hydrogen peroxide. The fluorescence membrane (i.e., QD–AF membrane) could detect hydrogen peroxide in linear detection ranges from 0.1 to 1.0 mM with a detection limit (LOD) of 0.016 mM and from 1.0 to 10 mM with an LOD of 0.058 mM. The sensitivity of the QD–AF membrane was increased by immobilizing horseradish peroxidase (HRP) over the surface of the QD–AF membrane (i.e., HRP–QD–AF membrane). The HRP–QD–AF membrane had an LOD of 0.011 mM for 0.1–1 mM H2O2 and an LOD of 0.068 mM for 1–10 mM H2O2. It showed higher sensitivity than the QD–AF membrane only, although both membranes had good selectivity. The HRP–QD–AF membrane could be applied to determine the concentration of hydrogen peroxide in wastewater, while the QD–AF membrane could be employed for the detection of α-ketobutyrate.