Arun Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Arun Rao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Ethan K. Murphy
Dartmouth College
3 shared publications - Kofi Odame
Thayer School of Engineering Dartmouth College Hanover NH USA
2 shared publications - Pavan Kumar Hanumolu
Department of Electrical and Computer Engineering, University of Illinois at UrbanaChampaign, Urbana, IL, USA
2 shared publications - Qadeer Ahmad Khan
Freescale Semicond. India Pvt. Ltd., Noida, India
2 shared publications - Amr Elshazly
Intel Corporation, Hillsboro, OR 97124 USA
1 shared publication - Chris Schaef
Thayer School of Engineering, Dartmouth College, Hanover, NH 03755 USA
1 shared publication
Latest Publications
- 13 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 787-799
A 1 MHz Miniaturized Electrical Impedance Tomography System for Prostate Imaging
An ASIC for a high frequency electrical impedance tomography (EIT) imaging system for prostate cancer screening is presented. The ASIC enables a small form-factor architecture, which ensures high signal-to-noise ratio (SNR) at MHz frequencies. The 4-channel ASIC was designed and fabricated in a standard CMOS 0.18-$\mu$m technology and integrates a novel current driver for current stimulus, instrumentation amplifier to interface with the tissue, VGA to provide variable gain and ADC with SPI interface for digitization. A prototype miniaturized EIT system was built and it was evaluated using a model transrectal imaging probe immersed into a tank filled with saline and a metal inclusion that demonstrated the open-domain problem of imaging prostate cancer lesion. The system maintained an SNR between 66 and 76 dB over the frequency range of 500 Hz to 1 MHz. Also, it produced reconstructed EIT images that depicted the presence of the small metal inclusion that modeled a prostate cancer imaging application.
- 13 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 14 (4) , 787-799
A 1 MHz Miniaturized Electrical Impedance Tomography System for Prostate Imaging
An ASIC for a high frequency electrical impedance tomography (EIT) imaging system for prostate cancer screening is presented. The ASIC enables a small form-factor architecture, which ensures high signal-to-noise ratio (SNR) at MHz frequencies. The 4-channel ASIC was designed and fabricated in a standard CMOS 0.18-$\mu$m technology and integrates a novel current driver for current stimulus, instrumentation amplifier to interface with the tissue, VGA to provide variable gain and ADC with SPI interface for digitization. A prototype miniaturized EIT system was built and it was evaluated using a model transrectal imaging probe immersed into a tank filled with saline and a metal inclusion that demonstrated the open-domain problem of imaging prostate cancer lesion. The system maintained an SNR between 66 and 76 dB over the frequency range of 500 Hz to 1 MHz. Also, it produced reconstructed EIT images that depicted the presence of the small metal inclusion that modeled a prostate cancer imaging application.
- 1 March 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (3) , 034005
Current-conveyor-based wide-band current driver for electrical impedance tomography
Objective : In this paper a wide-band integrated current driver for electrical impedance tomography (EIT) is presented. The application is primarily for prostate and breast cancer detection which require the tissue to be interrogated at frequencies up to 10 MHz while achieving low harmonic distortion and high accuracy. Approach : The current driver is based on current conveyor architecture and can deliver 1.2 mA of peak to peak ac current between frequencies of 100 Hz–10 MHz. It is fabricated in CMOS 0.18 m technology with a power supply of 3.3 V, and occupies a core area of 0.26 . Main results : The measured harmonic distortion for a peak current of 1.2 mA is < for frequencies less than 100 kHz, and increases to at 10 MHz. The measured output impedance of the current driver is 101 k at 1 MHz and 19.5 k at 10 MHz. Significance : The circuit is suitable for high frequency active electrode applications.
- 1 March 2019
- Published by IOP Publishing in Physiological Measurement
- Vol. 40 (3) , 034005
Current-conveyor-based wide-band current driver for electrical impedance tomography
Objective : In this paper a wide-band integrated current driver for electrical impedance tomography (EIT) is presented. The application is primarily for prostate and breast cancer detection which require the tissue to be interrogated at frequencies up to 10 MHz while achieving low harmonic distortion and high accuracy. Approach : The current driver is based on current conveyor architecture and can deliver 1.2 mA of peak to peak ac current between frequencies of 100 Hz–10 MHz. It is fabricated in CMOS 0.18 m technology with a power supply of 3.3 V, and occupies a core area of 0.26 . Main results : The measured harmonic distortion for a peak current of 1.2 mA is < for frequencies less than 100 kHz, and increases to at 10 MHz. The measured output impedance of the current driver is 101 k at 1 MHz and 19.5 k at 10 MHz. Significance : The circuit is suitable for high frequency active electrode applications.
- Open Access
- 12 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 729-738
An Analog Front End ASIC for Cardiac Electrical Impedance Tomography
In this paper, an end-to-end CMOS application specific integrated circuit (ASIC) for readout channel in a cardiac electrical impedance tomography system is presented. The ASIC consists of an integrated current driver for current injection, an instrumentation amplifier, variable gain amplifier at the analog front end for voltage readout from electrodes, and an on-chip 10-bit successive approximation register analog to digital converter with serial peripheral interface. The ASIC is fabricated in the CMOS 0.18 $\mu$m process with a supply voltage of 3.3 V. Amplitude and phase extraction of the voltages is performed in the digital domain with a matched filter. A fully integrated solution for use in multiple electrode system is demonstrated. The readout chain in the ASIC achieves a minimum signal-to-noise ratio of 71 dB over the frequency range of 500 Hz–700 kHz, while maintaining an average accuracy of 99.7$\%$. Frame rates of 21 frames per second for a 32 electrode system is feasible, and the ASIC has an overall power consumption of 11.8 mW.- 12 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 12 (4) , 729-738
Open AccessAn Analog Front End ASIC for Cardiac Electrical Impedance Tomography
In this paper, an end-to-end CMOS application specific integrated circuit (ASIC) for readout channel in a cardiac electrical impedance tomography system is presented. The ASIC consists of an integrated current driver for current injection, an instrumentation amplifier, variable gain amplifier at the analog front end for voltage readout from electrodes, and an on-chip 10-bit successive approximation register analog to digital converter with serial peripheral interface. The ASIC is fabricated in the CMOS 0.18 $\mu$m process with a supply voltage of 3.3 V. Amplitude and phase extraction of the voltages is performed in the digital domain with a matched filter. A fully integrated solution for use in multiple electrode system is demonstrated. The readout chain in the ASIC achieves a minimum signal-to-noise ratio of 71 dB over the frequency range of 500 Hz–700 kHz, while maintaining an average accuracy of 99.7$\%$. Frame rates of 21 frames per second for a 32 electrode system is feasible, and the ASIC has an overall power consumption of 11.8 mW. - 29 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 63 (1) , 100-105
A 2.5 pJ/b Binary Image Sensor as a Pathfinder for Quanta Image Sensors
This paper presents a pathfinder binary image sensor for exploring low-power dissipation needed for future implementation of gigajot single-bit quanta image sensor (QIS) devices. Using a charge-transfer amplifier design in the readout signal chain and pseudostatic clock gating units for row and column addressing, the 1-Mpixel binary image sensor operating at 1000 frames/s dissipates only 20-mW total power consumption, including I/O pads. The gain and analog-to-digital converter stages together dissipate 2.5 pJ/b, successfully paving the way for future gigajot QIS sensor designs.
- 29 July 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 63 (1) , 100-105
A 2.5 pJ/b Binary Image Sensor as a Pathfinder for Quanta Image Sensors
This paper presents a pathfinder binary image sensor for exploring low-power dissipation needed for future implementation of gigajot single-bit quanta image sensor (QIS) devices. Using a charge-transfer amplifier design in the readout signal chain and pseudostatic clock gating units for row and column addressing, the 1-Mpixel binary image sensor operating at 1000 frames/s dissipates only 20-mW total power consumption, including I/O pads. The gain and analog-to-digital converter stages together dissipate 2.5 pJ/b, successfully paving the way for future gigajot QIS sensor designs.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21585601,p. 1-2
A 1025MHz, 600mA buck converter using time-based PID compensator with 2A/MHz quiescent current, 94% peak efficiency, and 1MHz BW
A time-based PID compensator that combines the advantages of both analog and digital controllers is used to implement a high frequency low quiescent current buck converter. Fabricated in 180nm CMOS process, the proposed buck converter operates over a wide range of switching frequencies (10-25MHz) and achieves better than 94% peak efficiency while consuming a quiescent current of only 2μA/MHz.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21585601,p. 1-2
A 1025MHz, 600mA buck converter using time-based PID compensator with 2A/MHz quiescent current, 94% peak efficiency, and 1MHz BW
A time-based PID compensator that combines the advantages of both analog and digital controllers is used to implement a high frequency low quiescent current buck converter. Fabricated in 180nm CMOS process, the proposed buck converter operates over a wide range of switching frequencies (10-25MHz) and achieves better than 94% peak efficiency while consuming a quiescent current of only 2μA/MHz.
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 238-240
A 1.2A buck-boost LED driver with 13% efficiency improvement using error-averaged SenseFET-based current sensing
High-current LED drivers suffer from a significant efficiency loss due to the presence of a current regulation element (CRE) in series with the LED. In a conventional driver, either a series current source or a sense resistor acts as a CRE to regulate the LED current (l LED ). In this paper, we seek to improve the efficiency by eliminating the series CRE. To this end, we employ a highly accurate current sensing scheme to directly regulate l LED and achieve more than 13% efficiency improvement. The LED driver is fabricated in a 0.5μm CMOS process and operates at switching frequencies up to 2MHz with an off-chip 2.2μH inductor and a 10μF capacitor. The converter can drive up to 1200mA at an LED forward voltage of about 3.6V. This paper shows the converter start-up, l L , and V SENSE in all the 3 modes of operation. For better illustration, l L is displayed with a 50mA offset on all the plots. Because a different sense-FET is selected in each switching cycle, V SENSE differs from cycle to cycle by the amount of mismatch between the sense-FET and the power-FET. However, V SENSE averaged over 32 switching cycles, obtained from the LED current estimator, yields an accurate measure of the LED current.
- 1 February 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 01936530,p. 238-240
A 1.2A buck-boost LED driver with 13% efficiency improvement using error-averaged SenseFET-based current sensing
High-current LED drivers suffer from a significant efficiency loss due to the presence of a current regulation element (CRE) in series with the LED. In a conventional driver, either a series current source or a sense resistor acts as a CRE to regulate the LED current (l LED ). In this paper, we seek to improve the efficiency by eliminating the series CRE. To this end, we employ a highly accurate current sensing scheme to directly regulate l LED and achieve more than 13% efficiency improvement. The LED driver is fabricated in a 0.5μm CMOS process and operates at switching frequencies up to 2MHz with an off-chip 2.2μH inductor and a 10μF capacitor. The converter can drive up to 1200mA at an LED forward voltage of about 3.6V. This paper shows the converter start-up, l L , and V SENSE in all the 3 modes of operation. For better illustration, l L is displayed with a 50mA offset on all the plots. Because a different sense-FET is selected in each switching cycle, V SENSE differs from cycle to cycle by the amount of mismatch between the sense-FET and the power-FET. However, V SENSE averaged over 32 switching cycles, obtained from the LED current estimator, yields an accurate measure of the LED current.