Latest Publications

  • Open Access

    High-resolution cortical mapping within and across the central sulcus using 1024-electrode micro-electrocorticography arrays: illustrative case

    by Daniel D. Cummins, Katrina Barth, Elton Ho, Alexandra Fink Skular, Jacqueline Dister, Benjamin Rapoport, Ignacio Saez, Joshua B. Bederson

    BACKGROUND: Central sulcus identification using phase reversal on electrocorticography (ECoG) is a critical tool for neurosurgical intervention around the primary motor and somatosensory cortices. This mapping is typically performed using cortical arrays with a resolution of several millimeters. OBSERVATIONS: A 30-year-old female underwent a right frontoparietal craniotomy for resection of a 4-cm contrast-enhancing lesion within the central sulcus. Central sulcus localization was performed using a standard ECoG array. High-resolution micro-ECoG (µECoG) arrays were then placed over the pre- and postcentral gyri, giving 2048-electrode recordings across the central sulcus. Combining this high-resolution µECoG with an augmented reality imaging overlay to identify the tumor, the central sulcus was split, revealing the underlying tumor. A safe, gross-total resection was obtained with no postoperative complications. Through the use of µECoG arrays spanning into the central sulcus, a high-resolution phase-reversal contour was identified across the central sulcus. LESSONS: The authors demonstrate the feasibility and utility of µECoG for sensorimotor mapping within the central sulcus, revealing a phase reversal at a resolution of approximately 400 microns. Compared to standard mapping, which records gyral surface electrophysiology, they further demonstrate phase-reversal electrophysiology within a dissected central sulcus. High-resolution cortical mapping from µECoG may foster several neurosurgical advancements, from tumor resection to brain-computer interfaces. https://thejns.org/doi/10.3171/CASE25534


  • Top Cited Papers
    Open Access

    Minimally invasive implantation of scalable high-density cortical microelectrode arrays for multimodal neural decoding and stimulation

    by Mark Hettick, Elton Ho, Adam J. Poole, Manuel Monge, Demetrios Papageorgiou, Kazutaka Takahashi, Morgan LaMarca, Daniel Trietsch, Kyle Reed, Mark Murphy, et al.

    High-bandwidth brain–computer interfaces rely on invasive surgical procedures or brain-penetrating electrodes. Here we describe a cortical 1,024-channel thin-film microelectrode array and we demonstrate its minimally invasive surgical delivery that avoids craniotomy in porcine models and cadavers. We show recording and stimulation from the same electrodes to large portions of the cortical surface, and the reversibility of delivering the implants to multiple functional regions of the brain without damaging the cortical surface. We evaluate the performance of the interface for high-density neural recording and visualizing cortical surface activity at spatial and temporal resolutions and total spatial extents. We demonstrate accurate neural decoding of somatosensory, visual and volitional walking activity, and achieve focal neuromodulation through cortical stimulation at sub-millimetre scales. We report the feasibility of intraoperative use of the device in a five-patient pilot clinical study with anaesthetized and awake neurosurgical patients, characterizing the spatial scales at which sensorimotor activity and speech are represented at the cortical surface. The presented neural interface demonstrates the highly scalable nature of micro-electrocorticography and its utility for next-generation brain–computer interfaces.


  • Open Access

    First-in-human experience performing high-resolution cortical mapping using a novel microelectrode array containing 1024 electrodes

    by Peter Konrad, Kate R Gelman, Jesse Lawrence, Sanjay Bhatia, Dister Jacqueline, Radhey Sharma, Elton Ho, Yoon Woo Byun, Craig H Mermel, Benjamin I Rapoport

    Objective. Localization of function within the brain and central nervous system is an essential aspect of clinical neuroscience. Classical descriptions of functional neuroanatomy provide a foundation for understanding the functional significance of identifiable anatomic structures. However, individuals exhibit substantial variation, particularly in the presence of disorders that alter tissue structure or impact function. Furthermore, functional regions do not always correspond to identifiable structural features. Understanding function at the level of individual patients—and diagnosing and treating such patients—often requires techniques capable of correlating neural activity with cognition, behavior, and experience in anatomically precise ways. Approach. Recent advances in brain–computer interface technology have given rise to a new generation of electrophysiologic tools for scalable, nondestructive functional mapping with spatial precision in the range of tens to hundreds of micrometers, and temporal resolutions in the range of tens to hundreds of microseconds. Here we describe our initial intraoperative experience with novel, thin-film arrays containing 1024 surface microelectrodes for electrocorticographic mapping in a first-in-human study. Main results. Eight patients undergoing standard electrophysiologic cortical mapping during resection of eloquent-region brain tumors consented to brief sessions of concurrent mapping (micro-electrocorticography) using the novel arrays. Four patients underwent motor mapping using somatosensory evoked potentials (SSEPs) while under general anesthesia, and four underwent awake language mapping, using both standard paradigms and the novel microelectrode array. SSEP phase reversal was identified in the region predicted by conventional mapping, but at higher resolution (0.4 mm) and as a contour rather than as a point. In Broca’s area (confirmed by direct cortical stimulation), speech planning was apparent in the micro-electrocorticogram as high-amplitude beta-band activity immediately prior to the articulatory event. Significance. These findings support the feasibility and potential clinical utility of incorporating micro-electrocorticography into the intraoperative workflow for systematic cortical mapping of functional brain regions.


  • Open Access

    Electronic photoreceptors enable prosthetic visual acuity matching the natural resolution in rats

    by Bing-Yi Wang, Zhijie Charles Chen, Mohajeet Bhuckory, Tiffany Huang, Andrew Shin, Valentina Zuckerman, Elton Ho, Ethan Rosenfeld, Ludwig Galambos, Theodore Kamins, et al.

    Localized stimulation of the inner retinal neurons for high-acuity prosthetic vision requires small pixels and minimal crosstalk from the neighboring electrodes. Local return electrodes within each pixel limit the crosstalk, but they over-constrain the electric field, thus precluding the efficient stimulation with subretinal pixels smaller than 55 μm. Here we demonstrate a high-resolution prosthetic vision based on a novel design of a photovoltaic array, where field confinement is achieved dynamically, leveraging the adjustable conductivity of the diodes under forward bias to turn the designated pixels into transient returns. We validated the computational modeling of the field confinement in such an optically-controlled circuit by in-vitro and in-vivo measurements. Most importantly, using this strategy, we demonstrated that the grating acuity with 40 μm pixels matches the pixel pitch, while with 20 μm pixels, it reaches the 28 μm limit of the natural visual resolution in rats. This method enables customized field shaping based on individual retinal thickness and distance from the implant, paving the way to higher acuity of prosthetic vision in atrophic macular degeneration.


  • Open Access

    Electronic “photoreceptors” enable prosthetic vision with acuity matching the natural resolution in rats

    by Bing-Yi Wang, Zhijie Charles Chen, Mohajeet Bhuckory, Tiffany Huang, Andrew Shin, Valentina Zuckerman, Elton Ho, Ethan Rosenfeld, Ludwig Galambos, Theodore Kamins, et al.

    Localized stimulation of the inner retinal neurons for high-acuity prosthetic vision requires small pixels and minimal cross-talk from neighboring electrodes. Local return electrodes within each pixel limit crosstalk, but can over-constrain the electric field, thus precluding efficient stimulation with subretinal pixels smaller than 50 μm. Here we demonstrate high-resolution prosthetic vision based on a novel design of a photovoltaic array, where field confinement is achieved dynamically, leveraging the adjustable conductivity of the diodes under forward bias to turn the designated pixels into transient returns. We validated computational modeling of the field confinement in such an optically-controlled circuit by ex-vivo and in-vivo measurements. Most importantly, using this strategy, we demonstrated that the grating acuity with 40 μm pixels matches the pixel pitch, while with 20 μm pixels, it reaches the 28 μm limit of the natural visual resolution in rats. This method enables customized field shaping based on individual retinal thickness and distance from the implant, paving the way to prosthetic vision with acuity as high as 20/80 in atrophic macular degeneration.


  • Vertical-junction photodiodes for smaller pixels in retinal prostheses

    by Tiffany W Huang, Theodore I Kamins, Zhijie Charles Chen, Bing-Yi Wang, Mohajeet Bhuckory, Ludwig Galambos, Elton Ho, Tong Ling, Sean Afshar, Andrew Shin, et al.

    Objective. To restore central vision in patients with atrophic age-related macular degeneration, we replace the lost photoreceptors with photovoltaic pixels, which convert light into current and stimulate the secondary retinal neurons. Clinical trials demonstrated prosthetic acuity closely matching the sampling limit of the 100 μ m pixels, and hence smaller pixels are required for improving visual acuity. However, with smaller flat bipolar pixels, the electric field penetration depth and the photodiode responsivity significantly decrease, making the device inefficient. Smaller pixels may be enabled by (a) increasing the diode responsivity using vertical p–n junctions and (b) directing the electric field in tissue vertically. Here, we demonstrate such novel photodiodes and test the retinal stimulation in a vertical electric field. Approach. Arrays of silicon photodiodes of 55, 40, 30, and 20 μ m in width, with vertical p–n junctions, were fabricated. The electric field in the retina was directed vertically using a common return electrode at the edge of the device. Optical and electronic performance of the diodes was characterized in-vitro , and retinal stimulation threshold measured by recording the visually evoked potentials in rats with retinal degeneration. Main results. The photodiodes exhibited sufficiently low dark current (−1 , with 85% internal quantum efficiency, independent of pixel size. Field mapping in saline demonstrated uniformity of the pixel performance in the array. The full-field stimulation threshold was as low as 0.057 ± 0.029 mW mm −2 with 10 ms pulses, independent of pixel size. Significance. Photodiodes with vertical p–n junctions demonstrated excellent charge collection efficiency independent of pixel size, down to 20 μ m. Vertically oriented electric field provides a stimulation threshold that is independent of pixel size. These results are the first steps in validation of scaling down the photovoltaic pixels for subretinal stimulation.


  • Open Access

    Decoding network-mediated retinal response to electrical stimulation: implications for fidelity of prosthetic vision

    by Elton Ho, Alex Shmakov, Daniel Palanker

    Objective. Patients with photovoltaic subretinal implant PRIMA demonstrated letter acuity ∼0.1 logMAR worse than sampling limit for 100 μm pixels (1.3 logMAR) and performed slower than healthy subjects tested with equivalently pixelated images. To explore the underlying differences between natural and prosthetic vision, we compare the fidelity of retinal response to visual and subretinal electrical stimulation through single-cell modeling and ensemble decoding. Approach. Responses of retinal ganglion cells (RGCs) to optical or electrical white noise stimulation in healthy and degenerate rat retinas were recorded via multi-electrode array. Each RGC was fit with linear–nonlinear and convolutional neural network models. To characterize RGC noise, we compared statistics of spike-triggered averages (STAs) in RGCs responding to electrical or visual stimulation of healthy and degenerate retinas. At the population level, we constructed a linear decoder to determine the accuracy of the ensemble of RGCs on N-way discrimination tasks. Main results. Although computational models can match natural visual responses well (correlation ∼0.6), they fit significantly worse to spike timings elicited by electrical stimulation of the healthy retina (correlation ∼0.15). In the degenerate retina, response to electrical stimulation is equally bad. The signal-to-noise ratio of electrical STAs in degenerate retinas matched that of the natural responses when 78 ± 6.5% of the spikes were replaced with random timing. However, the noise in RGC responses contributed minimally to errors in ensemble decoding. The determining factor in accuracy of decoding was the number of responding cells. To compensate for fewer responding cells under electrical stimulation than in natural vision, more presentations of the same stimulus are required to deliver sufficient information for image decoding. Significance. Slower-than-natural pattern identification by patients with the PRIMA implant may be explained by the lower number of electrically activated cells than in natural vision, which is compensated by a larger number of the stimulus presentations.


  • Open Access

    Vertical-junction Photodiodes for Smaller Pixels in Retinal Prostheses

    by Tiffany W Huang, Theodore I Kamins, Zhijie Charles Chen, Bing-Yi Wang, Mohajeet Bhuckory, Ludwig Galambos, Elton Ho, Tong Ling, Sean Afshar, Andrew Shin, et al.

    Objective: To restore central vision in patients with atrophic age-related macular degeneration, we replace the lost photoreceptors with photovoltaic pixels, which convert light into current and stimulate the secondary retinal neurons. Clinical trials demonstrated prosthetic acuity closely matching the sampling limit of the 100 μm pixels, and hence smaller pixels are required for improving visual acuity. However, with smaller flat bipolar pixels, the electric field penetration depth and the photodiode responsivity significantly decrease, making the device inefficient. Smaller pixels may be enabled (1) by increasing the diode responsivity using vertical p-n junctions and (2) by directing the electric field vertically using 3-D electrodes. Here, we demonstrate such novel photodiodes and test the retinal stimulation in a vertical electric field. Approach: Arrays of silicon photodiodes of 55, 40, 30, and 20 μm in width, with vertical p-n junctions, were fabricated. The electric field in the retina was directed vertically by a common return electrode at the edge of the devices. Optical and electronic performance of the diodes was characterized in-vitro, and retinal stimulation threshold measured by recording the visually evoked potentials (VEPs) in rats with retinal degeneration. Main results: The photodiodes exhibited sufficiently low dark current (2 with 10 ms pulses, independent of pixel size. Significance: Photodiodes with vertical p-n junctions demonstrated excellent charge collection efficiency independent of pixel size, down to 20 μm. Vertically-oriented electric field provides a stimulation threshold that is independent of pixel size. These results are the first steps in validation of the feasibility of scaling down the photovoltaic pixels for subretinal stimulation.


  • Open Access

    Decoding network-mediated retinal response to electrical stimulation: implications for fidelity of prosthetic vision

    by Elton Ho, Alexander Shmakov, Daniel Palanker

    Objective: Patients with the photovoltaic subretinal implant PRIMA demonstrated letter acuity by ~0.1 logMAR worse than the sampling limit for 100μm pixels (1.3 logMAR) and performed slower than healthy subjects, which exceeded the sampling limit at equivalently pixelated images by ~0.2 logMAR. To explore the underlying differences between the natural and prosthetic vision, we compare the fidelity of the retinal response to visual and subretinal electrical stimulation through single-cell modeling and ensemble decoding. Approach: Responses of the retinal ganglion cells (RGC) to optical or electrical (1mm diameter arrays, 75μm pixels) white noise stimulation in healthy and degenerate rat retinas were recorded via MEA. Each RGC was fit with linear-non-linear (LN) and convolutional neural network (CNN) models. To characterize RGC noise level, we compared statistics of the spike-triggered average (STA) in RGCs responding to electrical or visual stimulation of healthy and degenerate retinas. At the population level, we constructed a linear decoder to determine the certainty with which the ensemble of RGCs can support the N -way discrimination tasks. Main results: Although LN and CNN models can match the natural visual responses pretty well (correlation ~0.6), they fit significantly worse to spike timings elicited by electrical stimulation of the healthy retina (correlation ~0.15). In the degenerate retina, response to electrical stimulation is equally bad. The signal-to-noise ratio of electrical STAs in degenerate retinas matched that of the natural responses when 78±6.5% of the spikes were replaced with random timing. However, the noise in RGC responses contributed minimally to errors in the ensemble decoding. The determining factor in accuracy of decoding was the number of responding cells. To compensate for fewer responding cells under electrical stimulation than in natural vision, larger number of presentations of the same stimulus are required to deliver sufficient information for image decoding. Significance: Slower than natural pattern identification by patients with the PRIMA implant may be explained by the lower number of electrically activated cells than in natural vision, which is compensated by a larger number of the stimulus presentations.

  • Open Access

    Performance of complex visual tasks using simulated prosthetic vision via augmented-reality glasses

    by Elton Ho, Jack Boffa, Daniel Palanker

    Photovoltaic subretinal prosthesis is designed for restoration of central vision in patients with age-related macular degeneration (AMD). We investigated the utility of prosthetic central vision for complex visual tasks using augmented-reality (AR) glasses simulating reduced acuity, contrast, and visual field. AR glasses with blocked central 20° of visual field included an integrated video camera and software which adjusts the image quality according to three user-defined parameters: resolution, corresponding to the equivalent pixel size of an implant; field of view, corresponding to the implant size; and number of grayscale levels. The real-time processed video was streamed on a screen in front of the right eye. Nineteen healthy participants were recruited to complete visual tasks including vision charts, sentence reading, and face recognition. With vision charts, letter acuity exceeded the pixel-sampling limit by 0.2 logMAR. Reading speed decreased with increasing pixel size and with reduced field of view (7°–12°). In the face recognition task (four-way forced choice, 5° angular size) participants identified faces at >75% accuracy, even with 100 μm pixels and only two grayscale levels. With 60 μm pixels and eight grayscale levels, the accuracy exceeded 97%. Subjects with simulated prosthetic vision performed slightly better than the sampling limit on the letter acuity tasks, and were highly accurate at recognizing faces, even with 100 μm/pixel resolution. These results indicate feasibility of reading and face recognition using prosthetic central vision even with 100 μm pixels, and performance improves further with smaller pixels.