Jingtao Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jingtao Dong has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Rongsheng Lu
School of Instrumental Science and Optoelectronic Engineering, Hefei University of Technology, Hefei, China
11 shared publications Tengda Zhang
Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology 1 , Hefei 230009, Anhui, China
10 shared publicationsLei Yang
7 shared publicationsYuzhong Zhang
6 shared publicationsRongsheng Lu
School of Instrument Science and Opto-electronic Engineering, Hefei University of Technology 1 , Hefei, Anhui 230009, China
5 shared publications- Sheng Zhou
Anhui University
4 shared publications
Latest Publications
- 16 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Dark-field differential confocal microscopy for three-dimensional detection of subsurface defects
- 16 September 2026
- Published by Elsevier in Measurement
- Vol. 292
Dark-field differential confocal microscopy for three-dimensional detection of subsurface defects
- Open Access
- 1 August 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (8)
High-resolution spiral phase contrast microscope: From Fourier filtering to match filtering
The wide-field spiral phase contrast microscope (SPCM) is an all-optical edge-enhanced imaging technique that performs Fourier filtering based on a 4f system. It allows large phase gradients to be highlighted through convolution of a phase object with the point spread function (PSF) given by the Fourier transform of the coherent transfer function (CTF). In the case of pupil mismatch between the 4f system and the spiral phase filter (SPF) placed at the Fourier plane, the physical edge diffraction of the SPF is non-negligible and will cause strong sidelobes in the PSF, leading to low image resolution and background noise after convolution. Herein, we propose a scanning SPCM, which uses an Airy spot to sample the phase object laterally point by point and detects the on-axis intensities at the image plane accordingly. This structural change transforms the SPCM from Fourier filtering to match filtering. Match filtering allows the SPCM to optically compute the complex weight that measures the matching degree between the Fourier transform of the local sampled field of the phase object and the joint CTF, which is the convolution of the illumination pupil and the imaging pupil. The edge enhanced image is directly given by the complex weights at the sampling coordinates. The scanning SPCM takes the advantage of the joint CTF, which not only shows a much higher cutoff spatial frequency than the wide-field SPCM, achieving high-resolution imaging, but also shows soft edges, achieving suppressions of physical edge diffraction of the SPF and sidelobes in the joint PSF. The imaging results of phase objects verified that the scanning SPCM achieves twofold resolution improvement. The scanning SPCM breaks through the inherent barrier of low image resolution in the wide-field SPCM by transforming Fourier filtering to match filtering, and it possesses great advantages in all-optical high-resolution edge enhancement.
- 1 August 2026
- Published by AIP Publishing in APL Photonics
- Vol. 11 (8)
Open AccessHigh-resolution spiral phase contrast microscope: From Fourier filtering to match filtering
The wide-field spiral phase contrast microscope (SPCM) is an all-optical edge-enhanced imaging technique that performs Fourier filtering based on a 4f system. It allows large phase gradients to be highlighted through convolution of a phase object with the point spread function (PSF) given by the Fourier transform of the coherent transfer function (CTF). In the case of pupil mismatch between the 4f system and the spiral phase filter (SPF) placed at the Fourier plane, the physical edge diffraction of the SPF is non-negligible and will cause strong sidelobes in the PSF, leading to low image resolution and background noise after convolution. Herein, we propose a scanning SPCM, which uses an Airy spot to sample the phase object laterally point by point and detects the on-axis intensities at the image plane accordingly. This structural change transforms the SPCM from Fourier filtering to match filtering. Match filtering allows the SPCM to optically compute the complex weight that measures the matching degree between the Fourier transform of the local sampled field of the phase object and the joint CTF, which is the convolution of the illumination pupil and the imaging pupil. The edge enhanced image is directly given by the complex weights at the sampling coordinates. The scanning SPCM takes the advantage of the joint CTF, which not only shows a much higher cutoff spatial frequency than the wide-field SPCM, achieving high-resolution imaging, but also shows soft edges, achieving suppressions of physical edge diffraction of the SPF and sidelobes in the joint PSF. The imaging results of phase objects verified that the scanning SPCM achieves twofold resolution improvement. The scanning SPCM breaks through the inherent barrier of low image resolution in the wide-field SPCM by transforming Fourier filtering to match filtering, and it possesses great advantages in all-optical high-resolution edge enhancement.
- 16 October 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Steady-state thermal lens strength detection via thermally induced diffraction effect
- 16 October 2025
- Published by Elsevier in Optics & Laser Technology
- Vol. 192
Steady-state thermal lens strength detection via thermally induced diffraction effect
- 24 January 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (3) , 892-895
Re-revealing dark-field scanning imaging via modal decomposition of bright-field light in the OAM domain
An alternative dark-field (DF) scanning imaging is re-revealed via modal decomposition of the bright-field (BF) light in the orbital angular momentum (OAM) domain. A Gaussian beam containing only the zeroth-order OAM mode illuminates the surface. The BF light scattered from the surface carries the phase shift induced by the surface feature and then diffracts into a distorted light field, which is a coherent sum of the different OAM modes. The amplitude weight and inter-modal phase of each mode are obtained by modal decomposition. As the surface is scanned transversely, the DF image contrast results from either the square amplitude or the inter-modal phase at the nonzero orders of OAM modes. The results verified that the first-order OAM mode produces a DF image with the highest contrast for the high-spatial-frequency surface features. The inter-modal phase DF image is less sensitive to the rough surface than the square amplitude DF image, thus producing a cleaner DF background. The square amplitude DF image is more advantageous in observing high-spatial-frequency surface features. The proposed DF scanning imaging in the OAM domain provides an additional degree of freedom for surface characterization.
- 24 January 2025
- Published by Optica Publishing Group in Optics Letters
- Vol. 50 (3) , 892-895
Re-revealing dark-field scanning imaging via modal decomposition of bright-field light in the OAM domain
An alternative dark-field (DF) scanning imaging is re-revealed via modal decomposition of the bright-field (BF) light in the orbital angular momentum (OAM) domain. A Gaussian beam containing only the zeroth-order OAM mode illuminates the surface. The BF light scattered from the surface carries the phase shift induced by the surface feature and then diffracts into a distorted light field, which is a coherent sum of the different OAM modes. The amplitude weight and inter-modal phase of each mode are obtained by modal decomposition. As the surface is scanned transversely, the DF image contrast results from either the square amplitude or the inter-modal phase at the nonzero orders of OAM modes. The results verified that the first-order OAM mode produces a DF image with the highest contrast for the high-spatial-frequency surface features. The inter-modal phase DF image is less sensitive to the rough surface than the square amplitude DF image, thus producing a cleaner DF background. The square amplitude DF image is more advantageous in observing high-spatial-frequency surface features. The proposed DF scanning imaging in the OAM domain provides an additional degree of freedom for surface characterization.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Stabilizing Orthogonal Phase Bias of Mach–Zehnder Interferometer via Dual-Wavelength Feedback and Geometric Phase Shifter
Stabilizing orthogonal phase bias is highly required in Mach-Zehnder interferometer (MZI) to achieve sufficiently high sensitivity and long-term stability. To this end, we demonstrated a stabilized MZI using dual-wavelength feedback and a geometric phase shifter (GPS). The two beams at the wavelengths of 632.8 nm and 532 nm, respectively, propagate almost in the common path in the MZI, so that the beams have the same sensitivity to ambient disturbance. The beam at 632.8 nm is used to sense the displacement, and the other one at 532 nm is used for feedback and orthogonal phase bias stabilization. The phase shift error of the two separate wavelengths can be compensated by a GPS consisting of a rotating half waveplate sandwiched between two static quarter waveplates. The results of the proof-of-concept experiment showed that the phase shift error between 632.8 nm and 532 nm was reduced to within (-0.08π, 0.09π) by the GPS, and can be further reduced by two orders of magnitude if more appropriate wavelengths or waveplates were selected. The stabilized MZI showed a displacement resolution of 5 nm, and was proved to be effective in suppressing the low-frequency noise less than 10 Hz.
- 14 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Stabilizing Orthogonal Phase Bias of Mach–Zehnder Interferometer via Dual-Wavelength Feedback and Geometric Phase Shifter
Stabilizing orthogonal phase bias is highly required in Mach-Zehnder interferometer (MZI) to achieve sufficiently high sensitivity and long-term stability. To this end, we demonstrated a stabilized MZI using dual-wavelength feedback and a geometric phase shifter (GPS). The two beams at the wavelengths of 632.8 nm and 532 nm, respectively, propagate almost in the common path in the MZI, so that the beams have the same sensitivity to ambient disturbance. The beam at 632.8 nm is used to sense the displacement, and the other one at 532 nm is used for feedback and orthogonal phase bias stabilization. The phase shift error of the two separate wavelengths can be compensated by a GPS consisting of a rotating half waveplate sandwiched between two static quarter waveplates. The results of the proof-of-concept experiment showed that the phase shift error between 632.8 nm and 532 nm was reduced to within (-0.08π, 0.09π) by the GPS, and can be further reduced by two orders of magnitude if more appropriate wavelengths or waveplates were selected. The stabilized MZI showed a displacement resolution of 5 nm, and was proved to be effective in suppressing the low-frequency noise less than 10 Hz.
- 9 December 2024
- Published by Elsevier in Optics Communications
- Vol. 577
Quantitative detection of weak scratches of optical elements based on image segmentation and connection of broken scratches
- 9 December 2024
- Published by Elsevier in Optics Communications
- Vol. 577
Quantitative detection of weak scratches of optical elements based on image segmentation and connection of broken scratches
- 21 January 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 175
Optical vortex interferometer: An overview of interferogram demodulation methods for dynamic phase measurement
- 21 January 2024
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 175
Optical vortex interferometer: An overview of interferogram demodulation methods for dynamic phase measurement
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Photothermal vortex interferometer with azimuthal complex spectra analysis for the measurement of laser-induced nanoscale thermal lens dynamics
A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre–Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m−1 and D = 5.63 × 10−7 m2 s−1, respectively, which agree with the nominal ones of A0 = 0.129 m−1 and D = 5.17 × 10−7 m2 s−1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessPhotothermal vortex interferometer with azimuthal complex spectra analysis for the measurement of laser-induced nanoscale thermal lens dynamics
A photothermal vortex interferometer (PTVI) is proposed to fill the gap of full-field measurement of the laser-induced nanoscale thermal lens dynamics of optical elements. The PTVI produces a multi-ring petal-like interferogram by the coaxial coherent superposition of the high-order conjugated Laguerre–Gaussian beams. The non-uniform optical path change (OPC) profile resulting from the thermal lens causes the petals of the interferogram at the different radii to shift by the different azimuths. To demodulate such an interferogram, an azimuthal complex spectra analysis is presented by using a camera with a pixelated multi-ring pattern written on its sensor to extract multiple azimuthal intensity profiles synchronously from the interferogram. Therefore, the OPC profile can be determined dynamically from the complex spectra of the azimuthal intensity profiles at the main frequency components. An analytical thermophysical model of the thermal lens is given, and the basic principle of the azimuthal complex spectra analysis is revealed. A proof-of-concept experiment is demonstrated using a N-BK7 glass sample heated by a pump laser. The results verified that the PTVI achieves the measurement accuracy of 47 pm with a standard deviation of 358 pm (3σ) and can be used for full-field measurement of the nanoscale OPC profile caused by the thermal lens dynamics. Due to the picometer-scale accuracy of the PTVI, the absorption coefficient and thermal diffusivity of the glass sample were determined to be A0 = 0.126 m−1 and D = 5.63 × 10−7 m2 s−1, respectively, which agree with the nominal ones of A0 = 0.129 m−1 and D = 5.17 × 10−7 m2 s−1. Although the PTVI is only suitable for measuring the rotationally symmetric OPC, it shows less computation burden and hardware complexity, and it is proved to be a highly sensitive and effective tool in studying optical, thermo-physical, and mechanical properties of optical elements.
- 7 September 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 171
Dynamic surface displacement measurement using carrier optical vortex interferometer: A numerical study
- 7 September 2023
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 171
Dynamic surface displacement measurement using carrier optical vortex interferometer: A numerical study