Wijitar Dungchai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wijitar Dungchai has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Nalin Ratnarathorn
Research Division, Office of Police Strategy, Royal Thai Police, Bangkok, Thailand
11 shared publicationsKawin Khachornsakkul
Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok 10140, Thailand
8 shared publications- Charles S. Henry
Colorado State University
5 shared publications Kamonchanok Phoonsawat
Organic Synthesis, Electrochemistry & Natural Product Research Unit, Department of Chemistry, Faculty of Science, King Mongkut's University of Technology Thonburi, Bangkok, 10140, Thailand
4 shared publicationsNatkrittaya Saengsawang
Analytical Chemistry, Department of Chemistry, Faculty of Science, King Mongkut’s University of Technology Thonburi, Bangkok, Thailand
4 shared publications- Toon Ruang-Areerate
Department of Parasitology, Phramongkutklao College of Medicine, Bangkok, Thailand
4 shared publications
Latest Publications
- 30 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (11) , 3174-3183
A simple photothermal paper-based analytical device using silver nanomaterials for quantitative mercury ion monitoring in drinking water and Wolffia samples
A highly sensitive and cost-effective photothermal-based paper analytical device (PT-PAD) has been developed using silver nanomaterials to monitor Hg 2+ levels.
- 30 March 2026
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (11) , 3174-3183
A simple photothermal paper-based analytical device using silver nanomaterials for quantitative mercury ion monitoring in drinking water and Wolffia samples
A highly sensitive and cost-effective photothermal-based paper analytical device (PT-PAD) has been developed using silver nanomaterials to monitor Hg 2+ levels.
- 8 December 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (2) , 636-649
Smartphone-based fluorescence detection of 2,4-dichlorophenoxyacetic acid using ImageJ analysis on a molecularly imprinted membrane/carbon-dot system via a Schiff-base method
The persistent presence of 2,4-dichlorophenoxyacetic acid (2,4-D) in aquatic ecosystems poses a significant risk to both the environment and human health. This study presents a novel fluorescence-based sensor designed to detect ultra-trace amounts of the pesticide 2,4-D. The sensor utilizes a dual-functional approach by combining nitrogen-doped carbon dots (N-CDs) and molecularly imprinted polymers (MIPs) integrated into a PVDF membrane. N-CDs were synthesized using a hydrothermal method with citric acid and ethylenediamine (EDA). The N-CDs were then modified with 3-aminopropyltriethoxysilane (APTES) to enhance their photoluminescence stability and their ability to recognize specific molecules. These functionalized nanomaterials were then covalently attached to a Piranha-activated polyvinylidene fluoride (PVDF) membrane. For the first time, this modified membrane was used as a substrate for 2,4-D molecular imprinting and exploited to reveal its physicochemical resilience, high porosity, and modifiable surface chemistry. A Schiff-base sol–gel imprinting approach enabled the fabrication of a robust molecularly imprinted polymer (MIP) layer with high affinity and selectivity toward 2,4-D. The dual-functional N-CDs simultaneously served as optical transducers and recognition elements. Fluorescence quenching, specifically in the context of binding 2,4-D, was detected using smartphone imaging and ImageJ analysis. The proposed sensor exhibited satisfactory linearity in the 2,4-D concentration range of 10–150 μg L−1 with the limit of detection (LOD) being 1.97 μg L−1 and the limit of quantification (LOQ) being 5.97 μg L−1. This sensor also exhibited photostability for 23 days at 4 °C, recoveries ranging from 96% to 103% and RSD value of less than 6. This work presents a smartphone-compatible MIP/N-CDs membrane designed for the detection of 2,4-D in water samples.
- 8 December 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 151 (2) , 636-649
Smartphone-based fluorescence detection of 2,4-dichlorophenoxyacetic acid using ImageJ analysis on a molecularly imprinted membrane/carbon-dot system via a Schiff-base method
The persistent presence of 2,4-dichlorophenoxyacetic acid (2,4-D) in aquatic ecosystems poses a significant risk to both the environment and human health. This study presents a novel fluorescence-based sensor designed to detect ultra-trace amounts of the pesticide 2,4-D. The sensor utilizes a dual-functional approach by combining nitrogen-doped carbon dots (N-CDs) and molecularly imprinted polymers (MIPs) integrated into a PVDF membrane. N-CDs were synthesized using a hydrothermal method with citric acid and ethylenediamine (EDA). The N-CDs were then modified with 3-aminopropyltriethoxysilane (APTES) to enhance their photoluminescence stability and their ability to recognize specific molecules. These functionalized nanomaterials were then covalently attached to a Piranha-activated polyvinylidene fluoride (PVDF) membrane. For the first time, this modified membrane was used as a substrate for 2,4-D molecular imprinting and exploited to reveal its physicochemical resilience, high porosity, and modifiable surface chemistry. A Schiff-base sol–gel imprinting approach enabled the fabrication of a robust molecularly imprinted polymer (MIP) layer with high affinity and selectivity toward 2,4-D. The dual-functional N-CDs simultaneously served as optical transducers and recognition elements. Fluorescence quenching, specifically in the context of binding 2,4-D, was detected using smartphone imaging and ImageJ analysis. The proposed sensor exhibited satisfactory linearity in the 2,4-D concentration range of 10–150 μg L−1 with the limit of detection (LOD) being 1.97 μg L−1 and the limit of quantification (LOQ) being 5.97 μg L−1. This sensor also exhibited photostability for 23 days at 4 °C, recoveries ranging from 96% to 103% and RSD value of less than 6. This work presents a smartphone-compatible MIP/N-CDs membrane designed for the detection of 2,4-D in water samples.
- Open Access
- 27 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
LAMP using distance based paper device for quantitative detection of ESBL producing Escherichia coli in UTI patients
Extended-spectrum beta-lactamases (ESBLs) producing E. coli are the most critical cause of antimicrobial resistance (AMR) and multidrug resistance (MDR) producing prolonged hospitalization and burden in treating nosocomial infection, in which the conventional culture regularly constitutes the gold standard diagnosis. In this study, we developed and validated a simple and inexpensive distance-based paper device (dPAD) LAMP assay for simultaneous screening and semi-quantifying the resistant bacterial load of ESBL-producing E. coli in 427 urine samples of patients with urinary tract infection (UTI). The device could measure the LAMP amplicons of blaTEM gene and semi-quantify the degree of ESBL-producing E. coli in heavy (≥ 102 CFU/mL), light (101–102 CFU/mL) and none (< 101 CFU/mL) using the fluorescent measurement of the migratory distance. The sensitivity and specificity exhibited reliable performances, achieving as high as 98.9 and 96.5%, respectively. The assay could be performed within 1 hour, which was comparatively faster than the culture method (> 48 h) and cheaper than qPCR. To empower early AMR diagnosis and fast treatment of MDR, this inexpensive dPAD LAMP assay is simple, reliably fast and practically portable for point-of-care settings, particularly in resource-limited areas that can be set up in all levels of healthcare facilities.
- 27 October 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessLAMP using distance based paper device for quantitative detection of ESBL producing Escherichia coli in UTI patients
Extended-spectrum beta-lactamases (ESBLs) producing E. coli are the most critical cause of antimicrobial resistance (AMR) and multidrug resistance (MDR) producing prolonged hospitalization and burden in treating nosocomial infection, in which the conventional culture regularly constitutes the gold standard diagnosis. In this study, we developed and validated a simple and inexpensive distance-based paper device (dPAD) LAMP assay for simultaneous screening and semi-quantifying the resistant bacterial load of ESBL-producing E. coli in 427 urine samples of patients with urinary tract infection (UTI). The device could measure the LAMP amplicons of blaTEM gene and semi-quantify the degree of ESBL-producing E. coli in heavy (≥ 102 CFU/mL), light (101–102 CFU/mL) and none (< 101 CFU/mL) using the fluorescent measurement of the migratory distance. The sensitivity and specificity exhibited reliable performances, achieving as high as 98.9 and 96.5%, respectively. The assay could be performed within 1 hour, which was comparatively faster than the culture method (> 48 h) and cheaper than qPCR. To empower early AMR diagnosis and fast treatment of MDR, this inexpensive dPAD LAMP assay is simple, reliably fast and practically portable for point-of-care settings, particularly in resource-limited areas that can be set up in all levels of healthcare facilities.
- Open Access
- 5 August 2025
- Published by College of Graduate Studies, Walailak University in Trends in Sciences
- Vol. 22 (11) , 10611
Highly Sensitive Electrochemical Sensor Modified with Pt/Pd-MnO2/CNT Nanocomposite for the Determination of Glutamate
A novel nanocomposite comprising platinum/palladium-decorated manganese dioxide on carbon nanotubes (Pt/Pd-MnO2/CNT) was successfully synthesized and immobilized onto a screen-printed carbon electrode (SPCE) for the electrochemical detection of glutamate. The electrocatalytic performance of the modified electrode was systematically evaluated using cyclic voltammetry (CV) and chronoamperometry (CA). Conventional glutamate biosensors that rely on the immobilization of glutamate oxidase often encounter several limitations, including high detection limits, electrode fouling, and poor operational stability, primarily due to enzyme leaching or denaturation. In contrast, the proposed sensor circumvents the need for enzyme immobilization on electrode by utilizing an electrocatalytic approach. This strategy maintains a high degree of analyte selectivity while significantly improving the sensor’s stability, reproducibility, and overall analytical performance. The resulting sensor exhibited high sensitivity, with a detection limit of 1.98 µM, surpassing previously reported values. It demonstrated a linear response in the range of 0.005 - 0.08 mM and showed excellent selectivity by minimizing interference from common electroactive species such as ascorbic acid (AA) and uric acid (UA), thanks to a reduction-based detection mechanism. The sensor also exhibited strong durability, retaining 96 % of its initial signal after 3 weeks of storage. Furthermore, it demonstrated excellent repeatability and reproducibility, as well as high resistance to common interferences. Validation studies conducted on spiked samples showed recovery rates between 99 and 105 %, confirming the method’s precision and accuracy. The practical application of the sensor was demonstrated through the quantification of glutamate in various instant noodle seasoning samples. The amounts of glutamate detected were 63.55 mg in Shrimp Tom Yum, 127.23 mg in Yentafo Tom Yum Mohfai, and 82.91 mg in Shrimp Creamy Tom Yum seasoning packets, respectively. In summary, the Pt/Pd-MnO2/CNT-modified electrode offers a reliable, sensitive, and selective platform for real-time electrochemical detection of glutamate in complex food matrices, highlighting its potential for application in food safety and quality control. HIGHLIGHTS A newly developed glutamate biosensor utilizing a Pt/Pd-MnO₂/CNT electrode enables efficient glutamate detection. The sensor demonstrates high selectivity, contributing to its cathodic current detection. The sensor exhibits high sensitivity, accuracy, and stability. The sensor was successfully applied to detect glutamate in food samples. GRAPHICAL ABSTRACT
- 5 August 2025
- Published by College of Graduate Studies, Walailak University in Trends in Sciences
- Vol. 22 (11) , 10611
Open AccessHighly Sensitive Electrochemical Sensor Modified with Pt/Pd-MnO2/CNT Nanocomposite for the Determination of Glutamate
A novel nanocomposite comprising platinum/palladium-decorated manganese dioxide on carbon nanotubes (Pt/Pd-MnO2/CNT) was successfully synthesized and immobilized onto a screen-printed carbon electrode (SPCE) for the electrochemical detection of glutamate. The electrocatalytic performance of the modified electrode was systematically evaluated using cyclic voltammetry (CV) and chronoamperometry (CA). Conventional glutamate biosensors that rely on the immobilization of glutamate oxidase often encounter several limitations, including high detection limits, electrode fouling, and poor operational stability, primarily due to enzyme leaching or denaturation. In contrast, the proposed sensor circumvents the need for enzyme immobilization on electrode by utilizing an electrocatalytic approach. This strategy maintains a high degree of analyte selectivity while significantly improving the sensor’s stability, reproducibility, and overall analytical performance. The resulting sensor exhibited high sensitivity, with a detection limit of 1.98 µM, surpassing previously reported values. It demonstrated a linear response in the range of 0.005 - 0.08 mM and showed excellent selectivity by minimizing interference from common electroactive species such as ascorbic acid (AA) and uric acid (UA), thanks to a reduction-based detection mechanism. The sensor also exhibited strong durability, retaining 96 % of its initial signal after 3 weeks of storage. Furthermore, it demonstrated excellent repeatability and reproducibility, as well as high resistance to common interferences. Validation studies conducted on spiked samples showed recovery rates between 99 and 105 %, confirming the method’s precision and accuracy. The practical application of the sensor was demonstrated through the quantification of glutamate in various instant noodle seasoning samples. The amounts of glutamate detected were 63.55 mg in Shrimp Tom Yum, 127.23 mg in Yentafo Tom Yum Mohfai, and 82.91 mg in Shrimp Creamy Tom Yum seasoning packets, respectively. In summary, the Pt/Pd-MnO2/CNT-modified electrode offers a reliable, sensitive, and selective platform for real-time electrochemical detection of glutamate in complex food matrices, highlighting its potential for application in food safety and quality control. HIGHLIGHTS A newly developed glutamate biosensor utilizing a Pt/Pd-MnO₂/CNT electrode enables efficient glutamate detection. The sensor demonstrates high selectivity, contributing to its cathodic current detection. The sensor exhibits high sensitivity, accuracy, and stability. The sensor was successfully applied to detect glutamate in food samples. GRAPHICAL ABSTRACT
- 1 July 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (7) , 5008-5018
Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification
The global prevalence of perfluoroalkyl and polyfluoroalkyl substance (PFAS) contamination highlights the need for sensitive, accessible, simple, and cost-effective analytical tools. In this article, we present the first photothermal-based microfluidic paper-based analytical device (PT-μPAD) for the detection of perfluorooctanesulfonate (PFOS), one of the most widespread PFAS, in various matrices, including water, food, and human samples. By integration of a molecularly imprinted polymer (MIP) with carbon dots (CDs), the device achieves selective and sensitive PFOS monitoring by measuring the temperature change on the μPAD sensor. Additionally, the detection signal is rapidly obtained via a wireless near-field communication (NFC) system embedded in a portable and user-friendly platform. Under optimization, the developed sensor delivers a linear range between 1.5 and 7.0 pg mL-1 (R2 = 0.9989) and a detection limit (limit of detection (LOD)) of 7.0 fg mL-1. Our developed sensor also exhibits high selectivity, with no observed interferent effects. The method also demonstrates remarkable accuracy and precision for PFOS quantification across real-world samples, achieving recovery percentages of 92.5-110.0% and the highest relative standard deviation (RSD) of 7.3%. Correspondingly, the results obtained using our method are comparable to those from the high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) method, as confirmed by a 95% confidence level in the t test analysis. Therefore, this sensor is well-suited for PFOS monitoring across various sample matrices, offering key advantages, such as simplicity, cost-effectiveness, portability, and ease of use by unskilled operators. Overall, this approach can be extended to the detection of other target molecules through MIP modification, showing its versatility. Furthermore, this concept holds great potential for broader applications, including medical point-of-care (POC) diagnostics and prognostics, on-site environmental analysis, and food safety.
- 1 July 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (7) , 5008-5018
Photothermal Paper-Based Microfluidic Analytical Device Integrated with Carbon Nanomaterials and Molecularly Imprinted Polymers for Sensitive Perfluorooctanesulfonate Quantification
The global prevalence of perfluoroalkyl and polyfluoroalkyl substance (PFAS) contamination highlights the need for sensitive, accessible, simple, and cost-effective analytical tools. In this article, we present the first photothermal-based microfluidic paper-based analytical device (PT-μPAD) for the detection of perfluorooctanesulfonate (PFOS), one of the most widespread PFAS, in various matrices, including water, food, and human samples. By integration of a molecularly imprinted polymer (MIP) with carbon dots (CDs), the device achieves selective and sensitive PFOS monitoring by measuring the temperature change on the μPAD sensor. Additionally, the detection signal is rapidly obtained via a wireless near-field communication (NFC) system embedded in a portable and user-friendly platform. Under optimization, the developed sensor delivers a linear range between 1.5 and 7.0 pg mL-1 (R2 = 0.9989) and a detection limit (limit of detection (LOD)) of 7.0 fg mL-1. Our developed sensor also exhibits high selectivity, with no observed interferent effects. The method also demonstrates remarkable accuracy and precision for PFOS quantification across real-world samples, achieving recovery percentages of 92.5-110.0% and the highest relative standard deviation (RSD) of 7.3%. Correspondingly, the results obtained using our method are comparable to those from the high-performance liquid chromatography-mass spectrometry (HPLC-MS/MS) method, as confirmed by a 95% confidence level in the t test analysis. Therefore, this sensor is well-suited for PFOS monitoring across various sample matrices, offering key advantages, such as simplicity, cost-effectiveness, portability, and ease of use by unskilled operators. Overall, this approach can be extended to the detection of other target molecules through MIP modification, showing its versatility. Furthermore, this concept holds great potential for broader applications, including medical point-of-care (POC) diagnostics and prognostics, on-site environmental analysis, and food safety.
- 2 June 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (8) , 1365-1372
A simple and cost-effective distance-based paper analytical device for phosphate ion determination
Phosphate ion (PO43–) monitoring in water sources is crucial due to its significant role in living systems and environmental impact, particularly in eutrophication. Conventional phosphate detection methods require sophisticated instruments and trained personnel. We report the development of a simple and cost-effective distance-based paper analytical device for phosphate ion detection. The device utilizes a complex of ferric ion (Fe3+), salicylic acid (SA), and polyethyleneimine (PEI) as the colorimetric indicator. Upon reaction with phosphate ions, Fe3+ forms a complex with phosphate, replacing the Fe3+–SA complex, leading to a visible color change from orange to colorless. The phosphate concentration is quantified by the distance of color change, which can be observed with the naked eye. Under the optimal conditions, the linearity was found in the range 5 to 75 mg/L (R2 = 0.9954), and the naked-eye detection limit was found at 2 mg/L. Furthermore, by applying a preconcentration method, the detection limit can be improved tenfold, achieving an LOD of 0.2 mg/L. Our proposed device for water sample application was also validated with the standard molybdenum blue method. A paired t-test was performed to compare the results obtained from both methods, and the statistical analysis indicated no significant difference between the two methods (p > 0.05). The method validation studies also showed acceptable performance, with spiked sample recoveries ranging from 85.05% to 117.97%, within the internationally recognized acceptable criteria of 80–120%. This method offers an alternative approach for accurate, rapid, on-site phosphate monitoring. Graphical abstract Schematic 1. Illustration of the fabrication process of a distance-based paper analytical device for the detection of phosphate ions.
- 2 June 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (8) , 1365-1372
A simple and cost-effective distance-based paper analytical device for phosphate ion determination
Phosphate ion (PO43–) monitoring in water sources is crucial due to its significant role in living systems and environmental impact, particularly in eutrophication. Conventional phosphate detection methods require sophisticated instruments and trained personnel. We report the development of a simple and cost-effective distance-based paper analytical device for phosphate ion detection. The device utilizes a complex of ferric ion (Fe3+), salicylic acid (SA), and polyethyleneimine (PEI) as the colorimetric indicator. Upon reaction with phosphate ions, Fe3+ forms a complex with phosphate, replacing the Fe3+–SA complex, leading to a visible color change from orange to colorless. The phosphate concentration is quantified by the distance of color change, which can be observed with the naked eye. Under the optimal conditions, the linearity was found in the range 5 to 75 mg/L (R2 = 0.9954), and the naked-eye detection limit was found at 2 mg/L. Furthermore, by applying a preconcentration method, the detection limit can be improved tenfold, achieving an LOD of 0.2 mg/L. Our proposed device for water sample application was also validated with the standard molybdenum blue method. A paired t-test was performed to compare the results obtained from both methods, and the statistical analysis indicated no significant difference between the two methods (p > 0.05). The method validation studies also showed acceptable performance, with spiked sample recoveries ranging from 85.05% to 117.97%, within the internationally recognized acceptable criteria of 80–120%. This method offers an alternative approach for accurate, rapid, on-site phosphate monitoring. Graphical abstract Schematic 1. Illustration of the fabrication process of a distance-based paper analytical device for the detection of phosphate ions.
- 10 August 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (11) , 2033-2041
Determination of hydroquinone in beverages using colorimetric and electrochemical sensors on paper-based device
Hydroquinone (HQ) is a phenolic compound used in industry processes. We aim to demonstrate a rapid and simple procedure for the determination of HQ. This work has developed two techniques, including colorimetric and electrochemical sensors on paper-based devices. Firstly, we have developed the colorimetric detection for the rapid screening test of HQ using 1.5% 4-(dimethylamino) benzaldehyde with alkaline condition (5 M NaOH). Under suitable conditions, the calibration curve between the intensity and HQ concentration was in the range of 50–500 mg L−1. Then, we developed a multi-walled carbon nanotube/graphene oxide/copper/palladium/platinum (MWCNT/GO/Cu/Pd/Pt) onto a screen-printed carbon electrode (SPCE). The optimal amount of MWCNT/GO/Cu/Pd/Pt nanomaterial is 2 mg for HQ detection. The linear concentration range was found in the range 1 to 20 mg L−1 and a detection limit was found to be 0.40 mg L−1 (3.6 µM) for HQ. Moreover, the proposed device can be applied to determine HQ in real samples and is inexpensive technique, portable, and low consumer time. Graphical abstract
- 10 August 2024
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (11) , 2033-2041
Determination of hydroquinone in beverages using colorimetric and electrochemical sensors on paper-based device
Hydroquinone (HQ) is a phenolic compound used in industry processes. We aim to demonstrate a rapid and simple procedure for the determination of HQ. This work has developed two techniques, including colorimetric and electrochemical sensors on paper-based devices. Firstly, we have developed the colorimetric detection for the rapid screening test of HQ using 1.5% 4-(dimethylamino) benzaldehyde with alkaline condition (5 M NaOH). Under suitable conditions, the calibration curve between the intensity and HQ concentration was in the range of 50–500 mg L−1. Then, we developed a multi-walled carbon nanotube/graphene oxide/copper/palladium/platinum (MWCNT/GO/Cu/Pd/Pt) onto a screen-printed carbon electrode (SPCE). The optimal amount of MWCNT/GO/Cu/Pd/Pt nanomaterial is 2 mg for HQ detection. The linear concentration range was found in the range 1 to 20 mg L−1 and a detection limit was found to be 0.40 mg L−1 (3.6 µM) for HQ. Moreover, the proposed device can be applied to determine HQ in real samples and is inexpensive technique, portable, and low consumer time. Graphical abstract
- Open Access
- 31 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Validation of quantitative loop-mediated isothermal amplification assay using a fluorescent distance-based paper device for detection of Escherichia coli in urine
Uropathogenic Escherichia coli (UPEC) causes up to 90% of urinary tract infections (UTI) which is more prevalent among females than males. In urine, patients with symptomatic UTI usually have a high concentration of bacterial infection, ≥ 105 colony-forming units (CFU) per mL, in which the culture method is regularly the gold standard diagnosis. In this study, a simple and inexpensive distance-based paper device (dPAD) combined with the fluorescent closed tube LAMP assay was validated for simultaneously screening and semi-quantifying the infection level of E. coli in 440 urine samples of patients with UTI. The dPAD could measure the LAMP amplicons and semi-quantify the levels of E. coli infection in heavy (≥ 104 CFU/mL), light (≤ 103 CFU/mL) and no infection. The sensitivity and specificity had reliable performances, achieving as high as 100 and 92.7%, respectively. The one step LAMP assay could be performed within 3 h, which was 7.5 times faster than the culture method. To empower early UTI diagnosis and fast treatment, this inexpensive dPAD tool combined with the fluorescent closed tube LAMP assay is simple, reliably fast and practically portable for point-of-care settings, particularly in resource-limited areas, which can be set up in all levels of healthcare facilities.
- 31 October 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Open AccessValidation of quantitative loop-mediated isothermal amplification assay using a fluorescent distance-based paper device for detection of Escherichia coli in urine
Uropathogenic Escherichia coli (UPEC) causes up to 90% of urinary tract infections (UTI) which is more prevalent among females than males. In urine, patients with symptomatic UTI usually have a high concentration of bacterial infection, ≥ 105 colony-forming units (CFU) per mL, in which the culture method is regularly the gold standard diagnosis. In this study, a simple and inexpensive distance-based paper device (dPAD) combined with the fluorescent closed tube LAMP assay was validated for simultaneously screening and semi-quantifying the infection level of E. coli in 440 urine samples of patients with UTI. The dPAD could measure the LAMP amplicons and semi-quantify the levels of E. coli infection in heavy (≥ 104 CFU/mL), light (≤ 103 CFU/mL) and no infection. The sensitivity and specificity had reliable performances, achieving as high as 100 and 92.7%, respectively. The one step LAMP assay could be performed within 3 h, which was 7.5 times faster than the culture method. To empower early UTI diagnosis and fast treatment, this inexpensive dPAD tool combined with the fluorescent closed tube LAMP assay is simple, reliably fast and practically portable for point-of-care settings, particularly in resource-limited areas, which can be set up in all levels of healthcare facilities.
- 17 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (19) , 4753-4761
A sensitive and facile electrochemical paper-based sensor for glucose detection in whole blood using the Pd/CB-Ni@rGO modified electrode
We created novel Pd/CB-Ni@rGO nanomaterials for glucose detection. The as-synthesized nanomaterials were dropped on the electrode surface using the drop casting technique. The prepared electrode was then attached to a paper-based device containing the sample zone and the reaction zone, enabling plasma isolation and an enzymatic reaction for glucose detection in whole blood. The nanomaterials and surfaces of electrodes were characterized by FTIR, TEM, and SEM. The proposed approach is a disposable glucose detection method that is unaffected by protein fouling on the electrode, and it requires only one drop of human blood. Therefore, there is no need for extensive sample preparation, and there is less sample consumption. Under optimal conditions, Pd/CB-Ni@rGO can accurately measure blood glucose levels with a linear range of 7 to 7140 μM (R2 = 0.9986) and a low detection limit of 0.82 μM. Besides, the developed sensor shows excellent anti-interference capacity, stability, and satisfactory reproducibility and repeatability. Importantly, Pd/CB-Ni@rGO was successfully applied for glucose in whole blood from 4 volunteers, with results that correlated well with those obtained using an Accucheck glucometer at a 95% confidence level. Given its low cost, high accuracy, and ease of use, the blood glucose sensor holds significant potential for clinical use and broadens the area of future noninvasive sensor development.
- 17 August 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (19) , 4753-4761
A sensitive and facile electrochemical paper-based sensor for glucose detection in whole blood using the Pd/CB-Ni@rGO modified electrode
We created novel Pd/CB-Ni@rGO nanomaterials for glucose detection. The as-synthesized nanomaterials were dropped on the electrode surface using the drop casting technique. The prepared electrode was then attached to a paper-based device containing the sample zone and the reaction zone, enabling plasma isolation and an enzymatic reaction for glucose detection in whole blood. The nanomaterials and surfaces of electrodes were characterized by FTIR, TEM, and SEM. The proposed approach is a disposable glucose detection method that is unaffected by protein fouling on the electrode, and it requires only one drop of human blood. Therefore, there is no need for extensive sample preparation, and there is less sample consumption. Under optimal conditions, Pd/CB-Ni@rGO can accurately measure blood glucose levels with a linear range of 7 to 7140 μM (R2 = 0.9986) and a low detection limit of 0.82 μM. Besides, the developed sensor shows excellent anti-interference capacity, stability, and satisfactory reproducibility and repeatability. Importantly, Pd/CB-Ni@rGO was successfully applied for glucose in whole blood from 4 volunteers, with results that correlated well with those obtained using an Accucheck glucometer at a 95% confidence level. Given its low cost, high accuracy, and ease of use, the blood glucose sensor holds significant potential for clinical use and broadens the area of future noninvasive sensor development.
- 16 March 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (14) , 6880-6888
A novel pyrenyl-furan hydrazone on paper-based device for the selective detection of trinitrotoluene
A new fluorescent probe (T2) containing pyrene-hydrazone furan moieties was developed and synthesized through a two-step process and then coated onto filter paper to form a paper-based sensor for TNT detection. The T2 sensor uses photoinduced electron transfer (PET) induced fluorescence quenching to detect TNT. The sensor properties were studied using fluorescence spectra, 1H-NMR titration and density functional theory (DFT) calculations. The reaction time of the T2 paper-based sensor for TNT detection was only five minutes. A smartphone was used as an alternative instrument to detect fluorescence signals and a typical image J-processing application was employed to evaluate the grayscale values of the smartphone-captured photographs. The sensor showed a linear concentration range for TNT detection of between 30–500 μM and a detection limit of 30 μM. The T2 paper-based sensor was found to have high selectivity and sensitivity, and it can successfully detect and image TNT in actual samples. This research demonstrates that a T2 paper-based sensor is a promising alternative for TNT detection owing to its short reaction time, high selectivity, sensitivity, and easy applicability.
- 16 March 2023
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 47 (14) , 6880-6888
A novel pyrenyl-furan hydrazone on paper-based device for the selective detection of trinitrotoluene
A new fluorescent probe (T2) containing pyrene-hydrazone furan moieties was developed and synthesized through a two-step process and then coated onto filter paper to form a paper-based sensor for TNT detection. The T2 sensor uses photoinduced electron transfer (PET) induced fluorescence quenching to detect TNT. The sensor properties were studied using fluorescence spectra, 1H-NMR titration and density functional theory (DFT) calculations. The reaction time of the T2 paper-based sensor for TNT detection was only five minutes. A smartphone was used as an alternative instrument to detect fluorescence signals and a typical image J-processing application was employed to evaluate the grayscale values of the smartphone-captured photographs. The sensor showed a linear concentration range for TNT detection of between 30–500 μM and a detection limit of 30 μM. The T2 paper-based sensor was found to have high selectivity and sensitivity, and it can successfully detect and image TNT in actual samples. This research demonstrates that a T2 paper-based sensor is a promising alternative for TNT detection owing to its short reaction time, high selectivity, sensitivity, and easy applicability.