AWAndrej Wagner

Andrej Wagner

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrej Wagner has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single‐center implementation of endoscopic submucosal dissection (ESD) in the colorectum: Low recurrence rate after intention‐to‐treat ESD

    by Andrej Wagner, Daniel Neureiter, Tobias Kiesslich, Gernot W. Wolkersdörfer, Thomas Pleininger, Christian Mayr, Christiane Dienhart, Naohisa Yahagi, Tsuneo Oyama, Frieder Berr

    Background and Aim: Colorectal endoscopic submucosal dissection (ESD) shows higher R0 resection and lower local recurrence rates than endoscopic mucosal resection (EMR) in Japan. In Europe, independent learning of ESD in the colorectum is feasible, but yet to be analyzed for curative resection and recurrence rates.Methods: After experimental training under supervision by Japanese experts (T.O., N.Y.), three endoscopists independently carried out 83 ESD procedures intention‐to‐treat for lesions in the entire colorectum of 67 patients in a prospective registry (November 2009 to June 2016).Results: ESD was feasible in 80 (96%) colorectal neoplasias (mean diameter 33.6 [± 1.8] mm), and three more required conversion to piecemeal EMR. The lesions were adenomas in 66% with low‐grade intraepithelial neoplasia (LGIN), 29% with high‐grade intraepithelial neoplasia, and 5% with carcinomas (G2, pT1). ESD had to be facilitated by the final use of snaring (hybrid‐ESD, n = 45), especially in the initial learning period. En‐bloc resection rate was 85%. Complications were microperforations (7%, conducive to one hemicolectomy), and delayed bleeding (1%) without mortality or long‐term morbidity. Residual adenomas with LGIN (5%) after hybrid‐ESD did not recur after endoscopic ablation. All malignant neoplasias (34%) were curatively resected without recurrence after a mean follow up of 19.5 (± 3.2) months.Conclusions: During independent ESD learning in the colorectum, ESD intention‐to‐treat showed a low recurrence rate after appropriate training, and hybrid‐ESD showed acceptable complication and recurrence rates, justifying hybrid‐ESD as a strategy for self‐completion and rescue.


  • Reduced complication rates of percutaneous transhepatic biliary drainage with ultrasound guidance

    by Andrej Wagner, Christian Mayr, Tobias Kiesslich, Frieder Berr, Paul Friesenbichler, Gernot W. Wolkersdörfer

    Background: We aimed to analyze the benefits of adding ultrasound (US) guidance to the standard fluoroscopically assisted percutaneous transhepatic biliary drainage (F‐PTBD). We also performed a systematic literature review of success and complication rates of US‐PTBD in a wide field of indications.Methods: We evaluated a total of 81 US‐PTBDs carried out in our institution, 74% of which were part of the management of malignancy. In addition, we compared our results with those of a total of 5,272 procedures (3,779 F‐PTBD and 1,493 US‐PTBD) reported in the literature.Results: US‐PTBD was technically successful in 94% of attempts with a mean of 2.2 needle passes. Procedural success was achieved in 86% of cases. There were no procedure‐related deaths or severe complications. Minor complications were catheter dislodgement (15%) as well as one case each of a porto‐biliary fistula, hematoma, and biloma. A systematic review of the literature also showed that US‐PTBD has a similar technical success rate to F‐PTBD but lower median rates of severe early complications (0% versus 8%) and procedural death (0% versus 1%).Conclusions: Given our results and our review of the literature, US‐PTBD is as effective as F‐PTBD and has significantly lower complication rates. US‐PTBD should be preferred to F‐PTBD. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:400–407, 2017