José Luiz Gasche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
José Luiz Gasche has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Eduardo Baccin
Interventional Neuroradiology, Hospital Israelita Albert Einstein, São Paulo, Brazil
5 shared publications - Iago Lessa Oliveira
São Paulo State University (UNESP), School of Engineering, Bauru, Department of Mechanical Engineering, Av. Engenheiro Luiz Edmundo Carrijo Coube, 14-01, 17033-360, Bauru, SP, Brazil
5 shared publications - Philip Cardiff
School of Mechanical and Materials Engineering University College Dublin Dublin 4 Ireland
3 shared publications - Gabriel Bertacco dos Santos
School of Engineering, São Paulo State University (UNESP), Ilha Solteira 15385-000, SP, Brazil
2 shared publications - Julio Militzer
Department of Mechanical Engineering, Dalhousie University, Halifax, NS B3H 4R2, Canada
2 shared publications - Rafael Trindade Tatit
Department of Neurological Surgery, Mayo Clinic, Jacksonville, Florida, USA
2 shared publications
Latest Publications
- Open Access
On the major role played by the curvature of intracranial aneurysms walls in determining their mechanical response, local hemodynamics, and rupture likelihood
The properties of intracranial aneurysms (IAs) walls are known to be driven by the underlying hemodynamics adjacent to the IA sac. Different pathways exist explaining the connections between hemodynamics and local tissue properties. The emergence of such theories is essential if one wishes to compute the mechanical response of a patient-specific IA wall and predict its rupture. Apart from the hemodynamics and tissue properties, one could assume that the mechanical response also depends on the local morphology, more specifically, the wall curvature, with larger values at highly-curved wall portions. Nonetheless, this contradicts observations of IA rupture sites more often found at the dome, where the curvature is lower. This seeming contradiction indicates a complex interaction between local hemodynamics, wall morphology, and mechanical response, which warrants further investigation. This was the main goal of this work. We accomplished this by analysing the stress and stretch fields in different regions of the wall for a sample of IAs, which have been classified based on particular local hemodynamics and local curvature. Pulsatile numerical simulations were performed using the one-way fluid-solid interaction strategy implemented in OpenFOAM (solids4foam toolbox). We found that the variable best correlated with regions of high stress and stretch was the wall curvature. Additionally, our data suggest a connection between the local curvature and local hemodynamics, indicating that the curvature is a property that could be used to assess both mechanical response and hemodynamic conditions, and, moreover, to suggest new metrics based on the curvature to predict the likelihood of rupture.
Open AccessOn the major role played by the curvature of intracranial aneurysms walls in determining their mechanical response, local hemodynamics, and rupture likelihood
The properties of intracranial aneurysms (IAs) walls are known to be driven by the underlying hemodynamics adjacent to the IA sac. Different pathways exist explaining the connections between hemodynamics and local tissue properties. The emergence of such theories is essential if one wishes to compute the mechanical response of a patient-specific IA wall and predict its rupture. Apart from the hemodynamics and tissue properties, one could assume that the mechanical response also depends on the local morphology, more specifically, the wall curvature, with larger values at highly-curved wall portions. Nonetheless, this contradicts observations of IA rupture sites more often found at the dome, where the curvature is lower. This seeming contradiction indicates a complex interaction between local hemodynamics, wall morphology, and mechanical response, which warrants further investigation. This was the main goal of this work. We accomplished this by analysing the stress and stretch fields in different regions of the wall for a sample of IAs, which have been classified based on particular local hemodynamics and local curvature. Pulsatile numerical simulations were performed using the one-way fluid-solid interaction strategy implemented in OpenFOAM (solids4foam toolbox). We found that the variable best correlated with regions of high stress and stretch was the wall curvature. Additionally, our data suggest a connection between the local curvature and local hemodynamics, indicating that the curvature is a property that could be used to assess both mechanical response and hemodynamic conditions, and, moreover, to suggest new metrics based on the curvature to predict the likelihood of rupture.
- 10 October 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 136, 105498
A numerical investigation of the mechanics of intracranial aneurysms walls: Assessing the influence of tissue hyperelastic laws and heterogeneous properties on the stress and stretch fields
- 10 October 2022
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 136, 105498
A numerical investigation of the mechanics of intracranial aneurysms walls: Assessing the influence of tissue hyperelastic laws and heterogeneous properties on the stress and stretch fields
- 5 April 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (7)
Non-Newtonian Blood Modeling in Intracranial Aneurysm Hemodynamics: Impact on the Wall Shear Stress and Oscillatory Shear Index Metrics for Ruptured and Unruptured Cases
When simulating blood flow in intracranial aneurysms (IAs), the Newtonian model seems to be ubiquitous. However, analyzing the results from the few studies on this subject, the doubt remains on whether it is necessary to use non-Newtonian models in computational fluid dynamics (CFD) simulations of cerebral vascular flows. The objective of this study is to investigate whether different rheology models would influence the hemodynamic parameters related to the wall shear stress (WSS) for ruptured and unruptured IA cases, especially because ruptured aneurysms normally have morphological features, such as lobular regions and blebs, that could trigger non-Newtonian phenomena in the blood flow due to low shear rates. Using CFD in an open-source framework, we simulated four ruptured and four unruptured patient-specific aneurysms to assess the influence of the blood modeling on the main hemodynamic variables associated with aneurysm formation, growth, and rupture. Results for WSS and oscillatory shear index (OSI) and their metrics were obtained using Casson and Carreau–Yasuda non-Newtonian models and were compared with those obtained using the Newtonian model. We found that all differences between non-Newtonian and the Newtonian models were consistent among all cases irrespective of their rupture status. We further found that the WSS at peak systole is overestimated by more than 50% by using the non-Newtonian models, but its metrics based on time and surface averaged values are less affected—the maximum relative difference among the cases is 7% for the Casson model. On the other hand, the surface-averaged OSI is underestimated by more than 30% by the non-Newtonian models. These results suggest that it is recommended to investigate different blood rheology models in IAs simulations when specific parameters to characterize the flow are needed, such as peak-systole WSS and OSI.
- 5 April 2021
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (7)
Non-Newtonian Blood Modeling in Intracranial Aneurysm Hemodynamics: Impact on the Wall Shear Stress and Oscillatory Shear Index Metrics for Ruptured and Unruptured Cases
When simulating blood flow in intracranial aneurysms (IAs), the Newtonian model seems to be ubiquitous. However, analyzing the results from the few studies on this subject, the doubt remains on whether it is necessary to use non-Newtonian models in computational fluid dynamics (CFD) simulations of cerebral vascular flows. The objective of this study is to investigate whether different rheology models would influence the hemodynamic parameters related to the wall shear stress (WSS) for ruptured and unruptured IA cases, especially because ruptured aneurysms normally have morphological features, such as lobular regions and blebs, that could trigger non-Newtonian phenomena in the blood flow due to low shear rates. Using CFD in an open-source framework, we simulated four ruptured and four unruptured patient-specific aneurysms to assess the influence of the blood modeling on the main hemodynamic variables associated with aneurysm formation, growth, and rupture. Results for WSS and oscillatory shear index (OSI) and their metrics were obtained using Casson and Carreau–Yasuda non-Newtonian models and were compared with those obtained using the Newtonian model. We found that all differences between non-Newtonian and the Newtonian models were consistent among all cases irrespective of their rupture status. We further found that the WSS at peak systole is overestimated by more than 50% by using the non-Newtonian models, but its metrics based on time and surface averaged values are less affected—the maximum relative difference among the cases is 7% for the Casson model. On the other hand, the surface-averaged OSI is underestimated by more than 30% by the non-Newtonian models. These results suggest that it is recommended to investigate different blood rheology models in IAs simulations when specific parameters to characterize the flow are needed, such as peak-systole WSS and OSI.
- 17 February 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (3) , 1-14
A longitudinal study of a lateral intracranial aneurysm: identifying the hemodynamic parameters behind its inception and growth using computational fluid dynamics
- 17 February 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (3) , 1-14
A longitudinal study of a lateral intracranial aneurysm: identifying the hemodynamic parameters behind its inception and growth using computational fluid dynamics
- 10 December 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (3)
Stent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period
Stenting has become an important adjunctive tool for assisting coil embolization in complex-shaped intracranial aneurysms. However, as a secondary effect, stent deployment has been related to both immediate and delayed remodeling of the local vasculature. Recent studies have demonstrated that this phenomenon may assume different roles depending on the treatment stage. However, the extent of such event on the intra-aneurysmal hemodynamics is still unclear; especially when performing two-step stent-assisted coiling (SAC). Therefore, we performed computational fluid dynamics (CFD) analysis of the blood flow in four bifurcation aneurysms focusing on the stent healing period found in SAC as a two-step maneuver. Our results show that by changing the local vasculature, the intra-aneurysmal hemodynamics changes considerably. However, even though changes do occur, they were not consistent among the cases. Furthermore, by changing the local vasculature not only the shear levels change but also the shear distribution on the aneurysm surface. Additionally, a geometric analysis alone can mislead the estimation of the novel hemodynamic environment after vascular remodeling, especially in the presence of mixing streams. Therefore, although the novel local vasculature might induce an improved hemodynamic environment, it is also plausible to expect that adverse hemodynamic conditions might occur. This could pose a particularly delicate condition since the aneurysm surface remains completely exposed to the novel hemodynamic environment during the stent healing period. Finally, our study emphasizes that vascular remodeling should be considered when assessing the hemodynamics in aneurysms treated with stents, especially when evaluating the earlier stages of the treatment process.
- 10 December 2020
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 143 (3)
Stent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period
Stenting has become an important adjunctive tool for assisting coil embolization in complex-shaped intracranial aneurysms. However, as a secondary effect, stent deployment has been related to both immediate and delayed remodeling of the local vasculature. Recent studies have demonstrated that this phenomenon may assume different roles depending on the treatment stage. However, the extent of such event on the intra-aneurysmal hemodynamics is still unclear; especially when performing two-step stent-assisted coiling (SAC). Therefore, we performed computational fluid dynamics (CFD) analysis of the blood flow in four bifurcation aneurysms focusing on the stent healing period found in SAC as a two-step maneuver. Our results show that by changing the local vasculature, the intra-aneurysmal hemodynamics changes considerably. However, even though changes do occur, they were not consistent among the cases. Furthermore, by changing the local vasculature not only the shear levels change but also the shear distribution on the aneurysm surface. Additionally, a geometric analysis alone can mislead the estimation of the novel hemodynamic environment after vascular remodeling, especially in the presence of mixing streams. Therefore, although the novel local vasculature might induce an improved hemodynamic environment, it is also plausible to expect that adverse hemodynamic conditions might occur. This could pose a particularly delicate condition since the aneurysm surface remains completely exposed to the novel hemodynamic environment during the stent healing period. Finally, our study emphasizes that vascular remodeling should be considered when assessing the hemodynamics in aneurysms treated with stents, especially when evaluating the earlier stages of the treatment process.
- 1 October 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 118, 238-249
Influence of the valve-seat gap on the dynamics of reed type valves
- 1 October 2020
- Published by Elsevier in International Journal of Refrigeration
- Vol. 118, 238-249
Influence of the valve-seat gap on the dynamics of reed type valves
- 1 July 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 103, 287-300
Effective force area and discharge coefficient for reed type valves: A comprehensive data set from a numerical study
- 1 July 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 103, 287-300
Effective force area and discharge coefficient for reed type valves: A comprehensive data set from a numerical study
- 1 May 2009
- Published by Elsevier in International Journal of Refrigeration
- Vol. 32 (3) , 421-429
Pressure drop correlation for oil–refrigerant R134a mixture flashing flow in a small diameter tube
- 1 May 2009
- Published by Elsevier in International Journal of Refrigeration
- Vol. 32 (3) , 421-429
Pressure drop correlation for oil–refrigerant R134a mixture flashing flow in a small diameter tube