Iurii Nasieka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Iurii Nasieka has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
M. Boyko
6 shared publicationsV. Strelchuk
6 shared publicationsB. Danilchenko
Institute of Physics, NAS of Ukraine, 46 Pr. Nauki, Kyiv, Ukraine
4 shared publicationsL. Rashkovetskyi
Lashkarev Institute of Semiconductor Physics, NAS of Ukraine, 41 Pr. Nauki, Kyiv, Ukraine
4 shared publications- Stanislav Dudnik
JSC "FED
4 shared publications V. Strel'NItskij
4 shared publications
Latest Publications
- Open Access
- 8 August 2026
- Published by Publishing House Zaslavsky in TRAUMA
- Vol. 27 (4) , 337-347
Biofilm infection of orthopedic implants: diagnosis, treatment, and prevention
Biofilm infection of orthopedic implants is one of the most challenging problems in modern orthopedics and traumatology, as it combines microbial persistence, limited efficacy of systemic antibacterial therapy, chronic inflammation, impaired osseointegration, implant instability, and functional consequences of treatment. Microorganisms attach to the surfaces of endoprostheses, plates, screws, intramedullary rods, spinal systems, and other fixation devices, forming biofilms that are more tolerant to antibiotics and immune responses than free-living bacteria. This review purposed to summarize current data on the pathogenesis, microbiological spectrum, clinical forms, diagnosis, treatment, prevention, and antibiofilm coating strategies for orthopedic implants. A narrative literature search was performed in four bibliographic databases — PubMed, Scopus, Web of Science, and Google Scholar — and six publisher platforms: Elsevier, Springer Nature, Wiley, Oxford Academic, MDPI, and Frontiers. Eleven keyword groups were used in English and Ukrainian, publications from 2014 to 2026 were prioritized, and 37 sources were included after two-stage screening of titles/abstracts and full texts. The analysis showed that periprosthetic joint infection (PJI) and fracture-related infection (FRI) share the same biofilm mechanism but differ clinically because in FRI, the implant is also required to maintain fracture stability. Key diagnostic elements include deep tissue sampling, sonication of removed implants, histology, and standardized PJI/FRI criteria, whereas superficial swabs are insufficient for final therapeutic decision-making. Effective treatment requires surgical source control, stable fixation or implant revision, dead-space management, soft tissue coverage, and systemic and local antimicrobial therapy. The review identified 12 main groups of antibiofilm or antimicrobial coating strategies, including antibiotic-releasing systems, anti-biotic-loaded hydrogels, gentamicin-coated nails, metal-ion coatings, calcium phosphate-/hydroxyapatite-based systems, antimicrobial peptides, chitosan, nanostructured surfaces, and smart pH- or enzyme-responsive coatings. Multifunctional coatings based on bioactive glass, calcium phosphate, hydroxyapatite, silver, antibiotics, hydrogels, or combined systems are especially promising because they can inhibit early bacterial adhesion, reduce biofilm formation, and support osseointegration. However, most available evidence remains preclinical or clinically limited, and further validation is required before routine use in orthopedic traumatology.
- 8 August 2026
- Published by Publishing House Zaslavsky in TRAUMA
- Vol. 27 (4) , 337-347
Open AccessBiofilm infection of orthopedic implants: diagnosis, treatment, and prevention
Biofilm infection of orthopedic implants is one of the most challenging problems in modern orthopedics and traumatology, as it combines microbial persistence, limited efficacy of systemic antibacterial therapy, chronic inflammation, impaired osseointegration, implant instability, and functional consequences of treatment. Microorganisms attach to the surfaces of endoprostheses, plates, screws, intramedullary rods, spinal systems, and other fixation devices, forming biofilms that are more tolerant to antibiotics and immune responses than free-living bacteria. This review purposed to summarize current data on the pathogenesis, microbiological spectrum, clinical forms, diagnosis, treatment, prevention, and antibiofilm coating strategies for orthopedic implants. A narrative literature search was performed in four bibliographic databases — PubMed, Scopus, Web of Science, and Google Scholar — and six publisher platforms: Elsevier, Springer Nature, Wiley, Oxford Academic, MDPI, and Frontiers. Eleven keyword groups were used in English and Ukrainian, publications from 2014 to 2026 were prioritized, and 37 sources were included after two-stage screening of titles/abstracts and full texts. The analysis showed that periprosthetic joint infection (PJI) and fracture-related infection (FRI) share the same biofilm mechanism but differ clinically because in FRI, the implant is also required to maintain fracture stability. Key diagnostic elements include deep tissue sampling, sonication of removed implants, histology, and standardized PJI/FRI criteria, whereas superficial swabs are insufficient for final therapeutic decision-making. Effective treatment requires surgical source control, stable fixation or implant revision, dead-space management, soft tissue coverage, and systemic and local antimicrobial therapy. The review identified 12 main groups of antibiofilm or antimicrobial coating strategies, including antibiotic-releasing systems, anti-biotic-loaded hydrogels, gentamicin-coated nails, metal-ion coatings, calcium phosphate-/hydroxyapatite-based systems, antimicrobial peptides, chitosan, nanostructured surfaces, and smart pH- or enzyme-responsive coatings. Multifunctional coatings based on bioactive glass, calcium phosphate, hydroxyapatite, silver, antibiotics, hydrogels, or combined systems are especially promising because they can inhibit early bacterial adhesion, reduce biofilm formation, and support osseointegration. However, most available evidence remains preclinical or clinically limited, and further validation is required before routine use in orthopedic traumatology.
- 23 February 2025
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 339
Comparative study of detonation sprayed hydroxyapatite coatings on polyetheretherketone and titanium
- 23 February 2025
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 339
Comparative study of detonation sprayed hydroxyapatite coatings on polyetheretherketone and titanium
- Open Access
- 12 March 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Semiconductor physics, quantum electronics and optoelectronics
- Vol. 27 (01) , 079-089
Difference in the structure and morphology of CVD diamond films grown on negatively charged and grounded substrate holders: Optical study
Microcrystalline diamond films were grown by plasma-enhanced chemical vapor deposition from a CH4/H2 gas mixture on Si single-crystalline substrates placed on negatively charged and grounded substrate holders. The obtained diamond films had the (100) predominant faceting of microcrystals. The film structure and morphology were analyzed by scanning electron microscopy, photoluminescence, Raman and FTIR spectroscopies. The main physical factor causing the difference in the structure of the diamond films grown on the grounded and charged substrate holders was found to be the flow of low-energy (up to 200 eV) Si+, N2+, H, O ions in the latter holder. These ions predominantly embedded into the structure of the diamond films grown on the charged substrate holder leading to appearance of residual mechanical stress up to 2 GPa. Ion bombardment led to increase in the volume fraction of non-diamond carbon component in the film grain boundaries, decrease in sp3-bonded carbon fraction and reduction of the diamond microcrystals lateral size. Larger amount of grain boundaries in the diamond films grown on the charged substrate holder promoted diffusion of Si atoms from the substrate to the plasma and growing film surface, inducing formation of SiV centers in the diamond microcrystals even in the 150…200 μm thick films. The concentration of Si-related defects was much smaller in the films grown using the grounded substrate holder. These films had substantially smaller volume fraction of graphite-like carbon in the grain boundaries and were more homogeneous.
- 12 March 2024
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Semiconductor physics, quantum electronics and optoelectronics
- Vol. 27 (01) , 079-089
Open AccessDifference in the structure and morphology of CVD diamond films grown on negatively charged and grounded substrate holders: Optical study
Microcrystalline diamond films were grown by plasma-enhanced chemical vapor deposition from a CH4/H2 gas mixture on Si single-crystalline substrates placed on negatively charged and grounded substrate holders. The obtained diamond films had the (100) predominant faceting of microcrystals. The film structure and morphology were analyzed by scanning electron microscopy, photoluminescence, Raman and FTIR spectroscopies. The main physical factor causing the difference in the structure of the diamond films grown on the grounded and charged substrate holders was found to be the flow of low-energy (up to 200 eV) Si+, N2+, H, O ions in the latter holder. These ions predominantly embedded into the structure of the diamond films grown on the charged substrate holder leading to appearance of residual mechanical stress up to 2 GPa. Ion bombardment led to increase in the volume fraction of non-diamond carbon component in the film grain boundaries, decrease in sp3-bonded carbon fraction and reduction of the diamond microcrystals lateral size. Larger amount of grain boundaries in the diamond films grown on the charged substrate holder promoted diffusion of Si atoms from the substrate to the plasma and growing film surface, inducing formation of SiV centers in the diamond microcrystals even in the 150…200 μm thick films. The concentration of Si-related defects was much smaller in the films grown using the grounded substrate holder. These films had substantially smaller volume fraction of graphite-like carbon in the grain boundaries and were more homogeneous.
- Open Access
- 5 December 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Semiconductor physics, quantum electronics and optoelectronics
- Vol. 26 (4) , 368-375
Structural and morphological properties of hydroxylapatite coatings obtained by gas-detonation deposition on polymer and titanium substrates
The gas-detonation technique was used for the synthesis of biocompatible hydroxylapatite-based protective coatings on polymer and titanium substrates. Hydroxylapatite powder of high purity with a grain diameter of 50 µm was used as the raw material. The obtained coatings have the thickness close to 200 µm. It has been shown that the offered method enables to create of non-destructive hydroxylapatite-based coatings on polymer by varying the distance between the polymer target and the gun nozzle of gas- detonation setup. Using the data of Raman and X-ray measurements, it was ascertained that gas-detonation deposition doesn’t change the composition of the deposited material. The SEM investigation testifies that the formed hydroxylapatite-based coatings are porous. EPR studies have shown that there are no paramagnetic defects in the obtained coatings, and the coating itself has a higher radiation hardness as compared to the raw powder.
- 5 December 2023
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Semiconductor physics, quantum electronics and optoelectronics
- Vol. 26 (4) , 368-375
Open AccessStructural and morphological properties of hydroxylapatite coatings obtained by gas-detonation deposition on polymer and titanium substrates
The gas-detonation technique was used for the synthesis of biocompatible hydroxylapatite-based protective coatings on polymer and titanium substrates. Hydroxylapatite powder of high purity with a grain diameter of 50 µm was used as the raw material. The obtained coatings have the thickness close to 200 µm. It has been shown that the offered method enables to create of non-destructive hydroxylapatite-based coatings on polymer by varying the distance between the polymer target and the gun nozzle of gas- detonation setup. Using the data of Raman and X-ray measurements, it was ascertained that gas-detonation deposition doesn’t change the composition of the deposited material. The SEM investigation testifies that the formed hydroxylapatite-based coatings are porous. EPR studies have shown that there are no paramagnetic defects in the obtained coatings, and the coating itself has a higher radiation hardness as compared to the raw powder.
- Open Access
- 19 September 2023
- Published by Elsevier in Thin Solid Films
- Vol. 783
Tuning of adhesion and hardness of diamond-like carbon vacuum arc coatings by changing the amplitude of pulsed bias potential applied to the substrate
- 19 September 2023
- Published by Elsevier in Thin Solid Films
- Vol. 783
Open AccessTuning of adhesion and hardness of diamond-like carbon vacuum arc coatings by changing the amplitude of pulsed bias potential applied to the substrate
- Open Access
- 23 May 2022
- Published by Elsevier in Physics Letters A
- Vol. 443
The influence of different ratio of Ar and C gases and ion bombardment on the growth rate and sp3 bonds content in DLC-coatings synthesized in RF discharge- 23 May 2022
- Published by Elsevier in Physics Letters A
- Vol. 443
Open AccessThe influence of different ratio of Ar and C gases and ion bombardment on the growth rate and sp3 bonds content in DLC-coatings synthesized in RF discharge - 1 December 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 165, 108448
Increased radiation hardness of detector-grade Cd0.96Zn0.04Te crystals by doping with In and Ge
- 1 December 2019
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 165, 108448
Increased radiation hardness of detector-grade Cd0.96Zn0.04Te crystals by doping with In and Ge