Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laurent Julien Bouyer has a total of 311 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pain

    by Hugo Massé-Alarie, Jason Bouffard, Laurent J. Bouyer

  • Open Access

    Acceptability of Overground Wearable Powered Exoskeletons for People with Spinal Cord Injury: A Multicenter Qualitative Study

    by Noémie Fortin-Bédard, Alice Pellichero, Stéphanie Leplaideur, Marie-Caroline Delebecque, Caroline Charette, Willy Allègre, Alyson Champagne, Caroline Rahn, Andréanne K. Blanchette, Laurent Bouyer, et al.

    Background: Exoskeletons are used in rehabilitation centers for people with spinal cord injuries (SCI) due to the potential benefits they offer for locomotor rehabilitation. The acceptability of exoskeletons is crucial to promote rehabilitation and to ensure a successful implementation of this technology. The objective was to explore the acceptability of overground wearable powered exoskeleton used in rehabilitation among people with SCI. Methods: Fourteen individuals with SCI (9 men, mean [SD] age 47 years [14.8], a majority with traumatic and thoracic lesion (T6–T12)) who had utilized an exoskeleton in Canada or in France during their rehabilitation participated in a semi-structured interview. A thematic analysis using the theoretical framework of acceptability was carried out. Results: Participants were motivated to use an exoskeleton during their rehabilitation. They reported several perceived benefits to its use, including better walking pattern, increased endurance, and greater muscle mass. They also experienced mild pain, notable concentration demands, and fatigue. Most participants reported that using exoskeletons in their rehabilitation process was appropriate and relevant to them. Conclusions: Exoskeletons are generally well accepted by participants in this study. Adjustments in their use, such as conducting training sessions in obstacle-free environment and technological improvements to address the device’s restrictive characteristics, heaviness, and massiveness are however still needed.


  • Open Access

    Acceptability of Overground Wearable Powered Exoskeletons for People with Spinal Cord Injury: a Multicenter Qualitative Study

    by Noémie Fortin-Bédard, Alice Pellichero, Stéphanie Leplaideur, Marie-Caroline Delebecque, Caroline Charette, Willy Allègre, Alyson Champagne, Caroline Rahn, Andréanne K. Blanchette, Laurent Bouyer, et al.

    Background: Exoskeletons are used in rehabilitation centers for people with spinal cord injury (SCI) due to the potential benefits they offer for locomotor rehabilitation. The acceptability of exoskeletons is crucial to promote rehabilitation and to ensure a successful implementation of this technology. The objective was to explore the acceptability of overground wearable powered exoskeleton used in rehabilitation among people with SCI. Methods: Fourteen individuals with SCI (9 men, mean age 47 years [14,8], majority with traumatic and thoracic lesion (T6-T12)) who had utilized an exoskeleton in Canada or in France during their rehabilitation participated in a semi-structured interview. A thematic analysis using the Theoretical Framework of Acceptability was carried out. Results: Participants were motivated to use an exoskeleton during their rehabilitation. They reported several perceived benefits to its use, including better walking pattern, increased endurance and greater muscle mass. They also experienced mild pain, notable concentration demands and fatigue. Most participants reported that using exoskeletons in their rehabilitation process was appropriate and relevant to them. Conclusions: Exoskeletons are generally well accepted by participants in this study. Adjustments in their use, such as conducting training sessions in obstacle-free environment and technological improvements to address the device’s restrictive characteristics, heaviness, and massiveness are however still needed.

  • Open Access

    Acceptability of Rehabilitation Exoskeleton from the Perspective of Users with Spinal Cord Injury and Healthcare Professionals: a Mixed Methods Systematic Review

    by Noémie Fortin-Bédard, Julien Déry, Margaux Simon, Andreanne K. Blanchette, Laurent Bouyer, Martine Gagnon, François Routhier, Marie-Eve Lamontagne

    Objective The objective was to document the acceptability of rehabilitation exoskeletons from the perspective of users with spinal cord injury (SCI) and healthcare professionals (HP). Methods This mixed-methods systematic review considered quantitative, qualitative and mixed methods studies that included adults with SCI using an exoskeleton for gait rehabilitation, as well as HP working within rehabilitation settings with individuals with SCI who used an exoskeleton. A convergent integrated approach per the Joanna Briggs Institute (JBI) was used. Results A total of 22 studies were included. Overall, individuals with SCI and HP expressed a favorable level of acceptability. Participants reported a positive affective attitude, an overall satisfaction, and several psychological benefits. Few burdens, ethical issues and opportunity costs have also been reported in the studies. Maintaining realistic expectations towards exoskeleton use and ensuring the appropriate selection of users is important for intervention coherence. In general, there was a positive perception regarding effectiveness and self-efficacy. Nevertheless, only a limited number of studies focused primarily on measuring acceptability, revealing an important gap in the literature. Conclusions The acceptability of exoskeletons among people with SCI and HP tends to be positive, which is promising for the sustainable implementation of this technology. However, there is still a lack of knowledge about the acceptability of HP, with only two studies conducted among this population. It is crucial to persevere in documenting the acceptability of exoskeletons, notably by standardizing comprehensive approaches for measuring acceptability, and to continue refining this technology.


  • Open Access

    Potential of a New, Flexible Electrode sEMG System in Detecting Electromyographic Activation in Low Back Muscles during Clinical Tests: A Pilot Study on Wearables for Pain Management

    by Antoine Frasie, Hugo Massé-Alarie, Mathieu Bielmann, Nicolas Gauthier, Mourad Roudjane, Isabelle Pagé, Benoit Gosselin, Jean-Sébastien Roy, Younes Messaddeq, Laurent J. Bouyer

    Background: While low back pain (LBP) is the leading cause of disability worldwide, its clinical objective assessment is currently limited. Part of this syndrome arises from the abnormal sensorimotor control of back muscles, involving increased muscle fatigability (i.e., assessed with the Biering–Sorensen test) and abnormal muscle activation patterns (i.e., the flexion–extension test). Surface electromyography (sEMG) provides objective measures of muscle fatigue development (median frequency drop, MDF) and activation patterns (RMS amplitude change). This study therefore assessed the sensitivity and validity of a novel and flexible sEMG system (NSS) based on PEVA electrodes and potentially embeddable in textiles, as a tool for objective clinical LBP assessment. Methods: Twelve participants wearing NSS and a commercial laboratory sEMG system (CSS) performed two clinical tests used in LBP assessment (Biering–Sorensen and flexion–extension). Erector spinae muscle activity was recorded at T12-L1 and L4-L5. Results: NSS showed sensitivity to sEMG changes associated with fatigue development and muscle activations during flexion–extension movements (p < 0.05) that were similar to CSS (p > 0.05). Raw signals showed moderate cross-correlations (MDF: 0.60–0.68; RMS: 0.53–0.62). Adding conductive gel to the PEVA electrodes did not influence sEMG signal interpretation (p > 0.05). Conclusions: This novel sEMG system is promising for assessing electrophysiological indicators of LBP during clinical tests.


  • Open Access

    Exploring the Influence of Structured Familiarization to an Adjustable, Passive Load-Bearing Exoskeleton on Oxygen Consumption and Lower Limb Muscle Activation During Walking

    by Gabriel Diamond-Ouellette, Miorie Le Quang, Thomas Karakolis, Laurent J. Bouyer, Krista L. Best

    Walking patterns is modified during load carriage, resulting in an increased activation of lower limb muscles and energy expenditure. Negative effects of load carriage could be minimized by wearing an exoskeleton, but evidence on the effects are conflicting. The objectives of this study were to describe the influence of an adjustable, passive load-bearing exoskeleton on the metabolic cost of walking (MCW) and associated muscle activations, and to explore changes in MCW after a familiarization process. Thirteen participants walked on a treadmill with a 22.75 kg payload at six preselected speeds (from 0.67 to 1.56 m/s) under three walking conditions: 1) without exoskeleton (NoExo); 2) with exoskeleton before familiarization (ExoPre); and 3) with exoskeleton after familiarization (ExoPost). Metabolic data was normalized to walking speed to provide MCW. Multi-muscle surface electromyography (EMG) was time and amplitude normalized to the gait cycle to provide muscle activation patterns. The familiarization occurred over three weeks including exposure to the exoskeleton. Differences in MCW and muscle activations were compared using a nonparametric analysis of longitudinal data. There were statistically significant increases in MCW for all speeds in the ExoPre and ExoPost conditions compared the NoExo. The average muscle activation showed an increase during ExoPre and ExoPost for the three speeds evaluated. Post-hoc analysis showed no significant effect of the familiarization period on metabolic data. In conclusion, a first exposure to the adjustable exoskeleton increased MCW and muscle activations, but the familiarization process did not provide any benefits toward a reduction in MCW or reduction in muscle activations at all speeds evaluated.


  • Validation of the Borg CR10 Scale for the evaluation of shoulder perceived fatigue during work-related tasks

    by Antoine Frasie, Michaël Bertrand-Charette, Maxence Compagnat, Laurent J. Bouyer, Jean-Sébastien Roy


  • Motion Detection and Analysis Using Multimaterial Fiber Sensors

    by Magali Ozon, Antoine Frasie, Gabriel Gagnon-Turcotte, Mourad Roudjane, Laurent Bouyer, Ghyslain Gagnon, Younès Messaddeq, Benoit Gosselin

    This work presents a system for measuring and analyzing motion, by a portable electronic device and a flexible fiber sensor. The fiber is composed of multi-walled carbon nanotubes (MWCNTs) for its conductivity and polydimethylsiloxane elastomer (PDMS) for its elasticity. A new sensor interface circuit was designed in this study to interface with the fiber and measure its impedance. The measured impedance data are sampled and transmitted via Bluetooth to a laptop. The characteristics of the fiber and a wireless measurement system allow an easy integration into a smart garment to monitor various vital signs and motion markers (e.g angle, step). The system was assessed on a robotic arm before being put in realistic situations through various exercises (flexion/extension knee movements, standing multi-joint movements and walk/run on treadmill) on 5 participants for its ability to measure angle, number of movements, rate and speed. In addition, fibers measurement endurance capacities over months were observed. An assessment of the fiber impedance measurement circuit was performed (minimum resolution of 25 $\Omega$ , relative error of 2.82% on the estimated value of resistance). Tests carried out over a period of several months show that the fiber maintained good measurement performance when tested on a robotic arm, given an average correlation of 0.85 between angle and fiber impedance. The relative error (RE) made on the number of detected movements was 6.57% in average. In realistic workout situations, these values respectively reached between 0.58 and 73.95% for flexion/extension knee movements. A correlation factor of 0.76 was obtained when the participants were walking on a treadmill at a given speed. Otherwise, RE on number of movements was 8.33% for treadmill exercise, 12.84% on standing exercise. For these exercises and for the movement rate, the average correlation calculated with the reference was between 0.75 and 0.33. Finally, RE on estimated speed was 23.3% in average for the treadmill exercise. The system (sensor interface circuit and Fiber) allows to properly monitor human motion in various activities.


  • Top Cited Papers
    Open Access

    Reducing Noise, Artifacts and Interference in Single-Channel EMG Signals: A Review

    by Marianne Boyer, Laurent Bouyer, Jean-Sébastien Roy, Alexandre Campeau-Lecours

    Electromyography (EMG) is gaining importance in many research and clinical applications, including muscle fatigue detection, control of robotic mechanisms and prostheses, clinical diagnosis of neuromuscular diseases and quantification of force. However, EMG signals can be contaminated by various types of noise, interference and artifacts, leading to potential data misinterpretation. Even assuming best practices, the acquired signal may still contain contaminants. The aim of this paper is to review methods employed to reduce the contamination of single channel EMG signals. Specifically, we focus on methods which enable a full reconstruction of the EMG signal without loss of information. This includes subtraction methods used in the time domain, denoising methods performed after the signal decomposition and hybrid approaches that combine multiple methods. Finally, this paper provides a discussion on the suitability of the individual methods based on the type of contaminant(s) present in the signal and the specific requirements of the application.


  • Open Access

    Reducing Noise, Artifacts and Interference in Single-Channel EMG Signals : A Review

    by Marianne Boyer, Laurent Bouyer, Jean-Sébastien Roy, Alexandre Campeau-Lecours

    EMG analysis is becoming increasingly important in many research and clinical applications, including muscle fatigue detection, control of robotic mechanisms and prostheses, clinical diagnosis of neuromuscular diseases and quantification of force. However, electromyographic signals can be contaminated by various types of noise, interference and artifacts, which can lead to misinterpretation of the data acquired using this method. Even assuming best practices, the collected signal may still be altered by such contaminants. The aim of this paper is to review methods employed to reduce contamination of single channel EMG signals. This review is limited to methods performed directly on the measured EMG signal and those that allow total reconstruction of the EMG signal. Subtraction methods used in the time domain, denoising methods performed after signal decomposition and hybrid methods are assessed. It is defended that individual methods may be more or less suitable for a particular application depending on contaminant(s) present in the signal and on the specific requirements of the application.