EGEmily Lauren Graczyk

Emily Lauren Graczyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Emily Lauren Graczyk has a total of 142 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • User perspectives on the movement, control, and sensory features of upper limb prosthetic devices: a qualitative cross-case comparison

    by Melissa S. Schmitt, Alexandra Zanowick-Marr, Debra Kelty, Hannah Ludlow, Linda J. Resnik, Emily L. Graczyk

    An upper limb prosthesis can replace some capabilities of a missing hand and arm resulting from amputation or congenital limb deficiency. Active prostheses, including body powered and myoelectric d...

  • Open Access

    Targeting grasp-related cortical areas for intracortical brain-machine interfaces

    by Tyler R. Johnson, Crispin Foli, Emily C. Conlan, Katherine A. Koenig, Mark J. Lowe, William D. Memberg, Robert F. Kirsch, Eric Z. Herring, Stanley F. Bazarek, Emily L. Graczyk, et al.


  • Open Access

    Mind the gap: the temporal discrimination threshold of tactile sensation from implanted peripheral nerve stimulation

    by John D. Wright, Hamid Charkhkar, Emily L. Graczyk

    Background: The ability to reliably detect the temporal order, overlap, and gaps between multiple tactile stimuli is crucial for making sense of our haptic interactions with complex environments. One important property of temporal processing of touch is the temporal discrimination threshold (TDT), which measures the shortest gap between two sequential stimuli required for them to be perceived as separate events. While the temporal properties of natural somatosensation are well understood, much less is known about the temporal properties of sensation elicited by peripheral nerve stimulation (PNS) delivered via implanted neural interfaces. Improving our understanding of the TDT of PNS-evoked sensations is crucial for the development of effective neuroprostheses. Methods: This study was conducted with two individuals with unilateral upper limb loss implanted with 16-contact extraneural electrodes around the median, ulnar, and/or radial nerves. To measure TDT, we used an ascending staircase paradigm commonly used for clinical assessment of TDT. We investigated the effects of stimulation intensity, pulse train duration, and frequency on the TDT for five electrode contacts in total across the participants. Results: We found that the TDT significantly decreased with increasing stimulation intensity and frequency. We also found that the TDT of PNS pulse trains was significantly lower than the TDT of individual pulses. However, the duration of the stimulation pulse train did not have a consistent effect on TDT. For both participants, TDT values for implanted PNS were comparable to the values previously seen in the literature for electrocutaneous stimulation. Conclusion: Since PNS intensity and frequency are routinely adjusted to shape sensory experiences in neuroprosthetic applications, our findings highlight the need for coordinated control of stimulation timing alongside modulation of other PNS parameters. This coordination is essential to enable accurate timing perception, which is critical for functional upper limb tasks, such as detecting object slippage, manipulating objects, and maintaining grasp force. Therefore, our results have important implications for optimizing the delivery of sensory feedback in neuroprosthetic systems. Trial registration : This study was prospectively registered on ClinicalTrials.gov (#NCT04947462) on 06/23/2021.

  • Open Access

    Solving the problem of inception: A cross-species perspective on strategies for a mechanistic refinement of intracortical microstimulation

    by Takashi D Yoshida Kozai, Bryan Mac Hooks, Alberto L Vazquez, Omar Gharbawie, Chengcheng Huang, Emily L Graczyk, Matthew Smith, Dawn M Taylor, Ana G Hernandez-Reynoso, Alex London, et al.

    Microstimulation delivers electrical pulses directly into the brain, with one of its promises being to restore lost senses to millions of people. Yet a fundamental challenge remains: how do intracortical microstimulation (ICMS) patterns engage neural circuits to achieve the inception of specific experiences, such as vivid sensory percepts of touch and vision? Here, we define “inception” as the initiation of percepts evoked by microstimulation through the mapping of stimulation to circuit-level activity that results in sensory experiences. This perspective proposes an integrated research framework that combines Reverse Translation, Forward Translation, and computational neuroscience to bridge insights between clinical observations and high-resolution animal studies. Our framework envisions the development and evaluation of ICMS strategies within a cross-species system that narrows the range of plausible underlying neural mechanisms and the set of evoked perceptual outcomes. Reverse Translation uses human perceptual reports about phosphenes, tones, and touch to guide investigations in rodents and non-human primates (NHPs), mapping the cell types and circuits underlying each percept. Forward Translation leverages these biological insights to design refined ICMS protocols for selective circuit engagement. Bidirectional Translation weaves these approaches together through computational neuroscience, ensuring that experimental observations iteratively and continuously refine one another across species and experimental modalities. This integrated strategy aims to transform microstimulation research into a dynamic dialogue between fundamental science and human experience. Harnessing the Bidirectional Translation Framework can accelerate therapies that enhance quality of life for people with sensory or motor impairments, and contribute more broadly to systems neuroscience by uncovering the mechanisms by which causal manipulation changes activity in neurons and networks.


  • Open Access

    Cortical representation of sensation elicited by peripheral nerve stimulation in an individual with incomplete spinal cord injury

    by Preethisiri Bhat, William Memberg, Brianna Hutchison, Bryn Spilker, Rohit Bose, Crispin Foli, Aaron Ketting-Olivier, Dawn Taylor, Robert F. Kirsch, Eric Herring, et al.

    Peripheral nerve stimulation (PNS) is a promising technique for restoring touch to people with neurological injuries. However, its application remains limited because past studies solely focused on people with limb loss and because the optimal paradigm for encoding touch information is still unclear. This study investigated PNS as a modality to restore touch in an individual with sensory-incomplete spinal cord injury (SCI) and quantified intracortical activity in primary somatosensory cortex (S1) resulting from PNS. S1 activity serves as an objective measure to compare and refine PNS paradigms to ultimately improve the effectiveness of PNS as sensory feedback in bidirectional neuroprostheses. We found that PNS delivered to the median and ulnar nerves via chronically-implanted, multi-contact cuff electrodes consistently evoked hand sensations with intensities that reliably scaled with stimulation pulse width (PW). In S1, increasing PNS PW recruited larger cortical populations, increased multi-unit firing rates, and shortened latencies between PNS onset and peak S1 activation. Interestingly, most S1 responses to PNS had strong onset transients, like those previously observed in response to mechanical indentation. Because our PNS paradigm was designed to recruit a population of peripheral afferents synchronously at a fixed frequency, our results suggest that central mechanisms play a role in producing cortical onset transients. This study supports PNS as a viable sensory feedback approach for individuals with incomplete SCI and reveals the representation of electrically-evoked sensory percepts in human cortex for the first time.

  • Open Access

    Perceptual Differences between Cortical and Peripheral Stimulation Strategies for Sensory Restoration

    by Brianna C. Hutchison, Rohit Bose, Bronwyn J. Spilker, Preethisiri Bhat, William D. Memberg, Aaron Ketting-Olivier, Eric Herring, Jennifer Sweet, Jonathan P. Miller, Robert F. Kirsch, et al.

    Both intracortical microstimulation (ICMS) and peripheral nerve stimulation (PNS) can restore tactile sensation to people living with physical disabilities, such as spinal cord injury (SCI) or amputation. While both techniques have demonstrated success in evoking meaningful sensations in the upper limb, they have only been investigated in separate studies with different patient populations, and thus their perceptual characteristics have never been systematically compared to determine the relative advantages and limitations of each approach. In this study, we directly compared the perceived sensations evoked by ICMS and PNS to those evoked by mechanical touch in a participant with sensory incomplete spinal cord injury. We observed that ICMS evoked more localized percepts and felt more qualitatively similar to natural touch than PNS, whereas PNS evoked higher intensity and more reliable percepts than ICMS. We also found that, across stimulation approaches, the perceived naturalness ratings of sensations were more strongly related to the other perceptual variables than to stimulation variables, suggesting that naturalness is a higher order perceptual dimension that is cognitively constructed by the participant. Our results indicate that ICMS may be the better sensory stimulation approach for conveying naturalistic touch experiences during haptic exploration, due to its similarity to mechanical touch in perceptual quality. In contrast, PNS may be the better stimulation modality to deliver consistent and effective sensory feedback during closed-loop functional tasks, due to its higher reliability. These insights provide a framework for future development of patient-specific sensory neuroprostheses based on the needs and goals of the user.


  • Top Cited Papers
    Open Access

    Evoking stable and precise tactile sensations via multi-electrode intracortical microstimulation of the somatosensory cortex

    by Charles M. Greenspon, Giacomo Valle, Natalya D. Shelchkova, Taylor G. Hobbs, Ceci Verbaarschot, Thierri Callier, Ev I. Berger-Wolf, Elizaveta V. Okorokova, Brianna C. Hutchison, Efe Dogruoz, et al.

    Tactile feedback from brain-controlled bionic hands can be partially restored via intracortical microstimulation (ICMS) of the primary somatosensory cortex. In ICMS, the location of percepts depends on the electrode’s location and the percept intensity depends on the stimulation frequency and amplitude. Sensors on a bionic hand can thus be linked to somatotopically appropriate electrodes, and the contact force of each sensor can be used to determine the amplitude of a stimulus. Here we report a systematic investigation of the localization and intensity of ICMS-evoked percepts in three participants with cervical spinal cord injury. A retrospective analysis of projected fields showed that they were typically composed of a focal hotspot with diffuse borders, arrayed somatotopically in keeping with their underlying receptive fields and stable throughout the duration of the study. When testing the participants’ ability to rapidly localize a single ICMS presentation, individual electrodes typically evoked only weak sensations, making object localization and discrimination difficult. However, overlapping projected fields from multiple electrodes produced more localizable and intense sensations and allowed for a more precise use of a bionic hand.


  • Open Access

    Clinical Applications and Future Translation of Somatosensory Neuroprostheses

    by Emily Graczyk, Brianna Hutchison, Giacomo Valle, David Bjanes, Deanna Gates, Stanisa Raspopovic, Robert Gaunt

    Somatosensory neuroprostheses restore, replace, or enhance tactile and proprioceptive feedback for people with sensory impairments due to neurological disorders or injury. Somatosensory neuroprostheses typically couple sensor inputs from a wearable device, prosthesis, robotic device, or virtual reality system with electrical stimulation applied to the somatosensory nervous system via noninvasive or implanted interfaces. While prior research has mainly focused on technology development and proof-of-concept studies, recent acceleration of clinical studies in this area demonstrates the translational potential of somatosensory neuroprosthetic systems. In this review, we provide an overview of neurostimulation approaches currently undergoing human testing and summarize recent clinical findings on the perceptual, functional, and psychological impact of somatosensory neuroprostheses. We also cover current work toward the development of advanced stimulation paradigms to produce more natural and informative sensory feedback. Finally, we provide our perspective on the remaining challenges that need to be addressed prior to translation of somatosensory neuroprostheses.


  • Open Access

    Interleaved Multi-Contact Peripheral Nerve Stimulation to Enhance Reproduction of Tactile Sensation: A Computational Modeling Study

    by Tanya M. Tebcherani, Kenneth A. Loparo, Farhad Kaffashi, Dustin J. Tyler, Emily L. Graczyk

    Peripheral nerve stimulation (PNS) is an effective means to elicit sensation for rehabilitation of people with loss of a limb or limb function. While most current PNS paradigms deliver current through single electrode contacts to elicit each tactile percept, multi-contact extraneural electrodes offer the opportunity to deliver PNS with groups of contacts individually or simultaneously. Multi-contact PNS strategies could be advantageous in developing biomimetic PNS paradigms to recreate the natural neural activity during touch, because they may be able to selectively recruit multiple distinct neural populations. We used computational models and optimization approaches to develop a novel biomimetic PNS paradigm that uses interleaved multi-contact (IMC) PNS to approximate the critical neural coding properties underlying touch. The IMC paradigm combines field shaping, in which two contacts are active simultaneously, with pulse-by-pulse contact and parameter variations throughout the touch stimulus. We show in simulation that IMC PNS results in better neural code mimicry than single contact PNS created with the same optimization techniques, and that field steering via two-contact IMC PNS results in better neural code mimicry than one-contact IMC PNS. We also show that IMC PNS results in better neural code mimicry than existing PNS paradigms, including prior biomimetic PNS. Future clinical studies will determine if the IMC paradigm can improve the naturalness and usefulness of sensory feedback for those with neurological disorders.


  • Open Access

    A distributed, high-channel-count, implanted bidirectional system for restoration of somatosensation and myoelectric control

    by Joris M Lambrecht, Sedona R Cady, Erik J Peterson, Jeremy L Dunning, David A Dinsmoor, Forrest Pape, Emily L Graczyk, Dustin J Tyler

    Objective. We intend to chronically restore somatosensation and provide high-fidelity myoelectric control for those with limb loss via a novel, distributed, high-channel-count, implanted system. Approach. We have developed the implanted Somatosensory Electrical Neurostimulation and Sensing (iSens®) system to support peripheral nerve stimulation through up to 64, 96, or 128 electrode contacts with myoelectric recording from 16, 8, or 0 bipolar sites, respectively. The rechargeable central device has Bluetooth® wireless telemetry to communicate to external devices and wired connections for up to four implanted satellite stimulation or recording devices. We characterized the stimulation, recording, battery runtime, and wireless performance and completed safety testing to support its use in human trials. Results. The stimulator operates as expected across a range of parameters and can schedule multiple asynchronous, interleaved pulse trains subject to total charge delivery limits. Recorded signals in saline show negligible stimulus artifact when 10 cm from a 1 mA stimulating source. The wireless telemetry range exceeds 1 m (direction and orientation dependent) in a saline torso phantom. The bandwidth supports 100 Hz bidirectional update rates of stimulation commands and data features or streaming select full bandwidth myoelectric signals. Preliminary first-in-human data validates the bench testing result. Significance. We developed, tested, and clinically implemented an advanced, modular, fully implanted peripheral stimulation and sensing system for somatosensory restoration and myoelectric control. The modularity in electrode type and number, including distributed sensing and stimulation, supports a wide variety of applications; iSens® is a flexible platform to bring peripheral neuromodulation applications to clinical reality. ClinicalTrials.gov ID NCT04430218.