Xuemin Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuemin Zhou has a total of 134 co-authors. Here are the top co-authors by number of shared publications:
Junli Hong
School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China
21 shared publicationsWanying Zhu
School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China
21 shared publications- Bingzhi Li
State Key Laboratory of Microbial Technology School of Food Science and Pharmaceutical Engineering, Nanjing Normal University Nanjing China
17 shared publications Ruoyu Wang
11 shared publicationsTingting Wen
School of Pharmacy, Nanjing Medical University, Nanjing 210029, PR China; The First People's Hospital of Kunshan, Kunshan 215300, PR China
11 shared publicationsWei Yang
School of Pharmacy, Nanjing Medical University, Nanjing, Jiangsu 211166, China
11 shared publications
Latest Publications
- 20 March 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (7) , 8299-8306
A Dual-Functional BSA-MnO2 Quantum Dots-Based Ratiometric Sensor for the Detection of Acid Phosphatase
- 20 March 2024
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 7 (7) , 8299-8306
A Dual-Functional BSA-MnO2 Quantum Dots-Based Ratiometric Sensor for the Detection of Acid Phosphatase
- 29 July 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (8) , 1-11
A biosensor based on Fe3O4@MXene-Au nanocomposites with high peroxidase-like activity for colorimetric and smartphone-based detection of glucose
A novel magnetic nanozyme Fe3O4@MXene-Au nanocomposite, which possessed higher peroxidase-like activity than that of Fe3O4 nanoparticles and Fe3O4@MXene nanocomposites, was developed. The outstanding magnetic properties of the nanozyme endowed it with the ability of simple and rapid separation, achieving great recyclability. Based on Fe3O4@MXene-Au nanocomposites and glucose oxidase (Glu Ox), a highly selective colorimetric biosensor for glucose detection was developed. Fe3O4@MXene-Au nanocomposites can catalyze H2O2 produced from glucose catalyzed by glucose oxidase to ·OH and oxidize colorless 3,3′,5,5′-tetramethylbenzidine (TMB) to blue oxidized TMB (oxTMB) with a significant absorbance at 652 nm. The linear range of glucose was 0–1.4 mM under optimal conditions, with a limit of detection (LOD) of 0.11 mM. Glucose in human whole blood was successfully detected with satisfactory recoveries. Furthermore, a facile agarose hydrogel detection platform was designed. With smartphone software, glucose detection can be realized by the agarose hydrogel platform, demonstrating the potential in on-site and visual detection of glucose. Graphical abstract
- 29 July 2023
- Published by Springer Nature in Microchimica Acta
- Vol. 190 (8) , 1-11
A biosensor based on Fe3O4@MXene-Au nanocomposites with high peroxidase-like activity for colorimetric and smartphone-based detection of glucose
A novel magnetic nanozyme Fe3O4@MXene-Au nanocomposite, which possessed higher peroxidase-like activity than that of Fe3O4 nanoparticles and Fe3O4@MXene nanocomposites, was developed. The outstanding magnetic properties of the nanozyme endowed it with the ability of simple and rapid separation, achieving great recyclability. Based on Fe3O4@MXene-Au nanocomposites and glucose oxidase (Glu Ox), a highly selective colorimetric biosensor for glucose detection was developed. Fe3O4@MXene-Au nanocomposites can catalyze H2O2 produced from glucose catalyzed by glucose oxidase to ·OH and oxidize colorless 3,3′,5,5′-tetramethylbenzidine (TMB) to blue oxidized TMB (oxTMB) with a significant absorbance at 652 nm. The linear range of glucose was 0–1.4 mM under optimal conditions, with a limit of detection (LOD) of 0.11 mM. Glucose in human whole blood was successfully detected with satisfactory recoveries. Furthermore, a facile agarose hydrogel detection platform was designed. With smartphone software, glucose detection can be realized by the agarose hydrogel platform, demonstrating the potential in on-site and visual detection of glucose. Graphical abstract
- 20 January 2022
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 212, 112347
A biosensor based on the biomimetic oxidase Fe3O4@MnO2 for colorimetric determination of uric acid
- 20 January 2022
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 212, 112347
A biosensor based on the biomimetic oxidase Fe3O4@MnO2 for colorimetric determination of uric acid
- 1 January 2022
- Published by Elsevier in Food Chemistry
- Vol. 368, 130838
An “on-off” ratio photoluminescence sensor based on catalytically induced PET effect by Fe3O4 NPs for the determination of coumarin
- 1 January 2022
- Published by Elsevier in Food Chemistry
- Vol. 368, 130838
An “on-off” ratio photoluminescence sensor based on catalytically induced PET effect by Fe3O4 NPs for the determination of coumarin
- 3 May 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2767-2773
Electrochemical Biosensor Based on HRP/Ti3C2/Nafion Film for Determination of Hydrogen Peroxide in Serum Samples of Patients with Acute Myocardial Infarction
Hydrogen peroxide (H2O2) has been reported to mediate a variety of physiological and pathological processes in living systems. In this work, a biosensor for determination of H2O2 was prepared by using an HRP/Ti3C2/Nafion film-modified glassy carbon electrode (GCE). Ti3C2 nanosheets with remarkable conductivity and high specific surface area were chosen as carriers for HRP. Moreover, this biosensor modified with HRP has a specific catalytic effect on H2O2. The difference in peak current could reflect the quantitative change of H2O2. The linear range of the biosensor is 5–8000 μM, and the detection limit is 1 μM (S/N = 3). This biosensor was used to detect H2O2 in clinical serum samples of normal controls and patients with acute myocardial infarction (AMI) before and after percutaneous coronary intervention (PCI). The results showed that the difference between normal controls and patients is significant (P < 0.05), as well as the difference for patients before and after PCI (P < 0.01), but no significant difference existed between postoperative patients and normal controls. This biosensor has the advantages of simple preparation, high sensitivity, and quick detection, showing potential application in clinical diagnosis.
- 3 May 2021
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 7 (6) , 2767-2773
Electrochemical Biosensor Based on HRP/Ti3C2/Nafion Film for Determination of Hydrogen Peroxide in Serum Samples of Patients with Acute Myocardial Infarction
Hydrogen peroxide (H2O2) has been reported to mediate a variety of physiological and pathological processes in living systems. In this work, a biosensor for determination of H2O2 was prepared by using an HRP/Ti3C2/Nafion film-modified glassy carbon electrode (GCE). Ti3C2 nanosheets with remarkable conductivity and high specific surface area were chosen as carriers for HRP. Moreover, this biosensor modified with HRP has a specific catalytic effect on H2O2. The difference in peak current could reflect the quantitative change of H2O2. The linear range of the biosensor is 5–8000 μM, and the detection limit is 1 μM (S/N = 3). This biosensor was used to detect H2O2 in clinical serum samples of normal controls and patients with acute myocardial infarction (AMI) before and after percutaneous coronary intervention (PCI). The results showed that the difference between normal controls and patients is significant (P < 0.05), as well as the difference for patients before and after PCI (P < 0.01), but no significant difference existed between postoperative patients and normal controls. This biosensor has the advantages of simple preparation, high sensitivity, and quick detection, showing potential application in clinical diagnosis.
- 1 February 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 173, 112619
A CRISPR-derived biosensor for the sensitive detection of transcription factors based on the target-induced inhibition of Cas12a activation
- 1 February 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 173, 112619
A CRISPR-derived biosensor for the sensitive detection of transcription factors based on the target-induced inhibition of Cas12a activation
- 24 September 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (10) , 1-10
A label-free electrochemical biosensor based on magnetic biocomposites with DNAzyme and hybridization chain reaction dual signal amplification for the determination of Pb2+
A highly sensitive and selective electrochemical biosensor for Pb2+ with a dual-amplification strategy is proposed. The first amplification step was realized by the cycle of Pb2+ and 8–17 DNAzyme (S2), and the hybridization chain reaction (HCR) triggered by S1 further amplified the electrochemical signal. Fe3O4@Au NPs, as a multifunctional magnetic carrier, is not only manifested in the construction of a magnetically controlled electrochemical response interface, but also has significant contribution in the purifying system, reducing interference, increasing the specific surface area, and the DNA loading. The magnetic nanocomposites were characterized by TEM as spheres with particle size of around 39 nm. When there was no Pb2+, long double-strand DNA (dsDNA) is formed on the surface of Fe3O4@Au NPs by the S1-triggered HCR; in the presence of Pb2+, S2 is activated and S1 on the surface of magnetic biocomposites (Fe3O4@Au NPs-S1) is continuously cleaved with the cycle of Pb2+ and S2, leading to a significant decrease of methylene blue (MB) absorbed on dsDNA. Such reverse dual-signal amplification strategy effectively increased the current difference and improved the sensitivity of the proposed sensor. The electrochemical signal of MB was obtained by differential pulse voltammetry (DPV) with preconcentration, showing a linear response toward Pb2+ ranging from 50 pM to 1 μM with a detection limit of 15 pM. The proposed method has feasible applications in detecting other heavy metal ions based on other metal-dependent DNAzyme. Graphical Abstract
- 24 September 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (10) , 1-10
A label-free electrochemical biosensor based on magnetic biocomposites with DNAzyme and hybridization chain reaction dual signal amplification for the determination of Pb2+
A highly sensitive and selective electrochemical biosensor for Pb2+ with a dual-amplification strategy is proposed. The first amplification step was realized by the cycle of Pb2+ and 8–17 DNAzyme (S2), and the hybridization chain reaction (HCR) triggered by S1 further amplified the electrochemical signal. Fe3O4@Au NPs, as a multifunctional magnetic carrier, is not only manifested in the construction of a magnetically controlled electrochemical response interface, but also has significant contribution in the purifying system, reducing interference, increasing the specific surface area, and the DNA loading. The magnetic nanocomposites were characterized by TEM as spheres with particle size of around 39 nm. When there was no Pb2+, long double-strand DNA (dsDNA) is formed on the surface of Fe3O4@Au NPs by the S1-triggered HCR; in the presence of Pb2+, S2 is activated and S1 on the surface of magnetic biocomposites (Fe3O4@Au NPs-S1) is continuously cleaved with the cycle of Pb2+ and S2, leading to a significant decrease of methylene blue (MB) absorbed on dsDNA. Such reverse dual-signal amplification strategy effectively increased the current difference and improved the sensitivity of the proposed sensor. The electrochemical signal of MB was obtained by differential pulse voltammetry (DPV) with preconcentration, showing a linear response toward Pb2+ ranging from 50 pM to 1 μM with a detection limit of 15 pM. The proposed method has feasible applications in detecting other heavy metal ions based on other metal-dependent DNAzyme. Graphical Abstract
- 8 August 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (9) , 1-8
A label-free electrochemical magnetic aptasensor based on exonuclease III–assisted signal amplification for determination of carcinoembryonic antigen
A novel label-free and exonuclease III (Exo III)–assisted signal amplification electrochemical aptasensor was constructed for the determination of carcinoembryonic antigen (CEA) via magnetic field–induced self-assembly of magnetic biocomposites (Fe3O4@Au NPs-S1-S2-S3). The magnetic biocomposites were acquired by modifying double-stranded DNA (S1-S2-S3) on the surface of Fe3O4@Au nanoparticles (Fe3O4@Au NPs). Among them, Fe3O4@Au NPs were used as carriers for magnetic separation, thiolated single-stranded DNA (S1) provided signal sequence, CEA aptamer (S2) worked as a recognition element, and complementary strand (S3) was used to form double strands. In the presence of CEA, S2 bonded with CEA competitively; the exposed S1 could not be cleaved since Exo III was inactive against ssDNA. The G-quadruplex/hemin complexes finally formed with the existence of K+, and the high electrochemical signal of G-quadruplex/hemin complexes was recorded by differential pulse voltammetry (DPV) at − 0.6 V. Conversely, in the absence of CEA, dsDNA was cleaved from the 3′ blunt end by Exo III; the disappearance of G-rich sequence blocked the generation of the signal. This method exhibited good selectivity and sensitivity for the determination of CEA; the linear range was from 0.1 to 200 ng mL−1 and the limit of detection was 0.4 pg mL−1. Graphical abstract
- 8 August 2020
- Published by Springer Nature in Microchimica Acta
- Vol. 187 (9) , 1-8
A label-free electrochemical magnetic aptasensor based on exonuclease III–assisted signal amplification for determination of carcinoembryonic antigen
A novel label-free and exonuclease III (Exo III)–assisted signal amplification electrochemical aptasensor was constructed for the determination of carcinoembryonic antigen (CEA) via magnetic field–induced self-assembly of magnetic biocomposites (Fe3O4@Au NPs-S1-S2-S3). The magnetic biocomposites were acquired by modifying double-stranded DNA (S1-S2-S3) on the surface of Fe3O4@Au nanoparticles (Fe3O4@Au NPs). Among them, Fe3O4@Au NPs were used as carriers for magnetic separation, thiolated single-stranded DNA (S1) provided signal sequence, CEA aptamer (S2) worked as a recognition element, and complementary strand (S3) was used to form double strands. In the presence of CEA, S2 bonded with CEA competitively; the exposed S1 could not be cleaved since Exo III was inactive against ssDNA. The G-quadruplex/hemin complexes finally formed with the existence of K+, and the high electrochemical signal of G-quadruplex/hemin complexes was recorded by differential pulse voltammetry (DPV) at − 0.6 V. Conversely, in the absence of CEA, dsDNA was cleaved from the 3′ blunt end by Exo III; the disappearance of G-rich sequence blocked the generation of the signal. This method exhibited good selectivity and sensitivity for the determination of CEA; the linear range was from 0.1 to 200 ng mL−1 and the limit of detection was 0.4 pg mL−1. Graphical abstract