Di Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Di Lu has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
Harold Y. Hwang
Geballe Laboratory for Advanced Materials, Stanford University, Stanford, California 94305, United States
4 shared publications- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
4 shared publications Quansan Yang
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA; Department of Mechanical Engineering, Northwestern University, Evanston, IL, 60208, USA
4 shared publicationsYasuyuki Hikita
Stanford Institute for Materials and Energy Sciences, SLAC National Accelerator Laboratory, Menlo Park, California 94025, United States
4 shared publicationsMatthew R. MacEwan
Department of Neurological Surgery, Washington University School of Medicine, St Louis, MO, 63110, USA
3 shared publicationsWilson Z. Ray
Department of Neurosurgery, Washington University School of Medicine, St. Louis, MO 63110, USA
3 shared publications
Latest Publications
- Open Access
- 11 March 2026
- Published by Elsevier in Cell Reports Physical Science
- Vol. 7 (3)
Fast and cost-effective stacking construction of silicon circuits from standard layers
- 11 March 2026
- Published by Elsevier in Cell Reports Physical Science
- Vol. 7 (3)
Open AccessFast and cost-effective stacking construction of silicon circuits from standard layers
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
Oxidation degradation of TiN electrodes in DRAM capacitors and mitigation through AlN insertion
Given the increasing demand for high-performance capacitors in dynamic random access memories (DRAMs), boosting the dielectric constant (k) to maximize capacitance density becomes critical, which requires the mitigation of low-k interfacial oxidation layers between the TiN electrodes and the dielectrics. This study investigated the effect and mechanism of TiN oxidation under controlled annealing conditions, which resulted in a significant decrease in the dielectric constant due to dielectric relaxation and degraded reliability. To address this issue, we introduced an AlN insertion layer as an oxygen diffusion blocking layer, which effectively prevented interfacial oxidation. The AlN layer not only preserved the dielectric constant of the capacitors, it also reduced leakage current and enhanced device reliability. These findings systematically summarized the consequences of TiN interfacial oxidation, a common phenomenon observed in DRAM fabrication, and demonstrated the potential of AlN layers in enhancing the performance of TiN-based capacitors in advanced electronic applications.
- 12 January 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (2)
Oxidation degradation of TiN electrodes in DRAM capacitors and mitigation through AlN insertion
Given the increasing demand for high-performance capacitors in dynamic random access memories (DRAMs), boosting the dielectric constant (k) to maximize capacitance density becomes critical, which requires the mitigation of low-k interfacial oxidation layers between the TiN electrodes and the dielectrics. This study investigated the effect and mechanism of TiN oxidation under controlled annealing conditions, which resulted in a significant decrease in the dielectric constant due to dielectric relaxation and degraded reliability. To address this issue, we introduced an AlN insertion layer as an oxygen diffusion blocking layer, which effectively prevented interfacial oxidation. The AlN layer not only preserved the dielectric constant of the capacitors, it also reduced leakage current and enhanced device reliability. These findings systematically summarized the consequences of TiN interfacial oxidation, a common phenomenon observed in DRAM fabrication, and demonstrated the potential of AlN layers in enhancing the performance of TiN-based capacitors in advanced electronic applications.
- 12 July 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (35) , e2402419
Uniform, Fully Connected, High‐Quality Monocrystalline Freestanding Perovskite Oxide Films Fabricated from Recyclable Substrates
Releasing epitaxial perovskite oxide films from their native oxide substrates produces high quality, 2D‐material‐like monocrystalline freestanding oxide membranes, as potential key components for the next‐generation electronic devices. Two major obstacles still limit their practical applications: macroscopic material defects (mainly cracks) that lowers uniformity and yield, and the high cost of the consumed oxide substrates. Here, a two‐step film transfer method and a substrate recycling method enable repetitive fabrication of millimeter‐scale, fully‐connected freestanding oxide films of various chemical compositions from the same substrates; arrays of capacitor and resistor devices based on these oxides transferred on silicon indicate high uniformity, low sample‐to‐sample variation, and satisfactory electrical connectivity. The two‐step transfer suppresses crack formation by avoiding buckling‐delamination‐type relaxation of epitaxial strain, and the key point to achieve substrate reuse is to remove the residual Al species bonded to the substrate surfaces. The mitigation of such long‐lasting issues in freestanding oxide fabrication techniques may eventually pave roads toward future industrial‐grade devices, as well as enabling many research opportunities in fundamental physics.
- 12 July 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (35) , e2402419
Uniform, Fully Connected, High‐Quality Monocrystalline Freestanding Perovskite Oxide Films Fabricated from Recyclable Substrates
Releasing epitaxial perovskite oxide films from their native oxide substrates produces high quality, 2D‐material‐like monocrystalline freestanding oxide membranes, as potential key components for the next‐generation electronic devices. Two major obstacles still limit their practical applications: macroscopic material defects (mainly cracks) that lowers uniformity and yield, and the high cost of the consumed oxide substrates. Here, a two‐step film transfer method and a substrate recycling method enable repetitive fabrication of millimeter‐scale, fully‐connected freestanding oxide films of various chemical compositions from the same substrates; arrays of capacitor and resistor devices based on these oxides transferred on silicon indicate high uniformity, low sample‐to‐sample variation, and satisfactory electrical connectivity. The two‐step transfer suppresses crack formation by avoiding buckling‐delamination‐type relaxation of epitaxial strain, and the key point to achieve substrate reuse is to remove the residual Al species bonded to the substrate surfaces. The mitigation of such long‐lasting issues in freestanding oxide fabrication techniques may eventually pave roads toward future industrial‐grade devices, as well as enabling many research opportunities in fundamental physics.
- Open Access
- 22 May 2024
- Published by Elsevier in The Innovation
- Vol. 5 (4) , 100646
Engineering strontium aluminate sacrificial layers for fabricating monocrystalline complex oxide freestanding membranes
- 22 May 2024
- Published by Elsevier in The Innovation
- Vol. 5 (4) , 100646
Open AccessEngineering strontium aluminate sacrificial layers for fabricating monocrystalline complex oxide freestanding membranes
- Top Cited PapersOpen Access
- 19 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (16) , eadj0268
Bioresorbable, wireless, passive sensors for continuous pH measurements and early detection of gastric leakage
Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.
- 19 April 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (16) , eadj0268
Top Cited PapersOpen AccessBioresorbable, wireless, passive sensors for continuous pH measurements and early detection of gastric leakage
Continuous monitoring of biomarkers at locations adjacent to targeted internal organs can provide actionable information about postoperative status beyond conventional diagnostic methods. As an example, changes in pH in the intra-abdominal space after gastric surgeries can serve as direct indicators of potentially life-threatening leakage events, in contrast to symptomatic reactions that may delay treatment. Here, we report a bioresorbable, wireless, passive sensor that addresses this clinical need, designed to locally monitor pH for early detection of gastric leakage. A pH-responsive hydrogel serves as a transducer that couples to a mechanically optimized inductor-capacitor circuit for wireless readout. This platform enables real-time monitoring of pH with fast response time (within 1 hour) over a clinically relevant period (up to 7 days) and timely detection of simulated gastric leaks in animal models. These concepts have broad potential applications for temporary sensing of relevant biomarkers during critical risk periods following diverse types of surgeries.
- 11 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (11)
Oxygen vacancies and local amorphization introduced by high fluence neutron irradiation in β -Ga2O3 power diodes
Beta phase gallium oxide (β-Ga2O3) is emerging as a promising material for space applications due to its unique properties and potential high performance in extreme environments. In this work, we systematically study the impact of β-Ga2O3 Schottky barrier diodes (SBDs) under a high fluence neutron irradiation to explore the degradation mechanism of the devices. After irradiated by neutrons with an average energy of 1–2 MeV and a dose rate of 1.3 × 1012 cm−2 s−1, SBDs with a homoepitaxial layer suffered serious performance degradation. The main manifestation of this degradation was a substantial increase in on-resistance, which rose from 3.9 to 3.5 × 108 mΩ·cm2 under the aforementioned irradiation conditions. The appearance of amorphous/polycrystalline striped lattice damage in the epitaxial layer as well as the presence of deep-level defects caused by oxygen vacancies are factors related to this phenomenon. The simulation revealed that the capture reaction of neutrons and Ga elements is the primary cause of neutron irradiation. This reaction generates high-energy beta- particles (β-particles) resulting in the formation of defects. This paper reveals the degradation mechanism of β-Ga2O3 SBDs under neutron irradiation and provides a possible design roadmap for radiation-resistant β-Ga2O3 power devices. Moreover, a high-temperature oxygen annealing process was implemented, which proved to be in restoring the device performance.
- 11 September 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (11)
Oxygen vacancies and local amorphization introduced by high fluence neutron irradiation in β -Ga2O3 power diodes
Beta phase gallium oxide (β-Ga2O3) is emerging as a promising material for space applications due to its unique properties and potential high performance in extreme environments. In this work, we systematically study the impact of β-Ga2O3 Schottky barrier diodes (SBDs) under a high fluence neutron irradiation to explore the degradation mechanism of the devices. After irradiated by neutrons with an average energy of 1–2 MeV and a dose rate of 1.3 × 1012 cm−2 s−1, SBDs with a homoepitaxial layer suffered serious performance degradation. The main manifestation of this degradation was a substantial increase in on-resistance, which rose from 3.9 to 3.5 × 108 mΩ·cm2 under the aforementioned irradiation conditions. The appearance of amorphous/polycrystalline striped lattice damage in the epitaxial layer as well as the presence of deep-level defects caused by oxygen vacancies are factors related to this phenomenon. The simulation revealed that the capture reaction of neutrons and Ga elements is the primary cause of neutron irradiation. This reaction generates high-energy beta- particles (β-particles) resulting in the formation of defects. This paper reveals the degradation mechanism of β-Ga2O3 SBDs under neutron irradiation and provides a possible design roadmap for radiation-resistant β-Ga2O3 power devices. Moreover, a high-temperature oxygen annealing process was implemented, which proved to be in restoring the device performance.
- 6 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 206, 114145
Implantable, wireless, self-fixing thermal sensors for continuous measurements of microvascular blood flow in flaps and organ grafts
- 6 March 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 206, 114145
Implantable, wireless, self-fixing thermal sensors for continuous measurements of microvascular blood flow in flaps and organ grafts
- 14 May 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (10) , 4454-4460
Stabilization of Sr3Al2O6 Growth Templates for Ex Situ Synthesis of Freestanding Crystalline Oxide Membranes
A new synthetic approach has recently been developed for the fabrication of freestanding crystalline perovskite oxide nanomembranes, which involves the epitaxial growth of a water-soluble sacrificial layer. By utilizing an ultrathin capping layer of SrTiO3, here we show that this sacrificial layer, as grown by pulsed laser deposition, can be stabilized in air and therefore be used as transferrable templates for ex situ epitaxial growth using other techniques. We find that the stability of these templates depends on the thickness of the capping layer. On these templates, freestanding superconducting SrTiO3 membranes were synthesized ex situ using molecular beam epitaxy, enabled by the lower growth temperature which preserves the sacrificial layer. This study paves the way for the synthesis of an expanded selection of freestanding oxide membranes and heterostructures with a wide variety of ex situ growth techniques.
- 14 May 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (10) , 4454-4460
Stabilization of Sr3Al2O6 Growth Templates for Ex Situ Synthesis of Freestanding Crystalline Oxide Membranes
A new synthetic approach has recently been developed for the fabrication of freestanding crystalline perovskite oxide nanomembranes, which involves the epitaxial growth of a water-soluble sacrificial layer. By utilizing an ultrathin capping layer of SrTiO3, here we show that this sacrificial layer, as grown by pulsed laser deposition, can be stabilized in air and therefore be used as transferrable templates for ex situ epitaxial growth using other techniques. We find that the stability of these templates depends on the thickness of the capping layer. On these templates, freestanding superconducting SrTiO3 membranes were synthesized ex situ using molecular beam epitaxy, enabled by the lower growth temperature which preserves the sacrificial layer. This study paves the way for the synthesis of an expanded selection of freestanding oxide membranes and heterostructures with a wide variety of ex situ growth techniques.
- 10 March 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (6) , 2470-2475
Strain Gradient Elasticity in SrTiO3 Membranes: Bending versus Stretching
Young’s modulus determines the mechanical loads required to elastically stretch a material and also the loads required to bend it, given that bending stretches one surface while compressing the opposite one. Flexoelectric materials have the additional property of becoming electrically polarized when bent. The associated energy cost can additionally contribute to elasticity via strain gradients, particularly at small length scales where they are geometrically enhanced. Here, we present nanomechanical measurements of freely suspended SrTiO3 crystalline membrane drumheads. We observe an unexpected nonmonotonic thickness dependence of Young’s modulus upon small deflections. Furthermore, the modulus inferred from a predominantly bending deformation is three times larger than that of a predominantly stretching deformation for membranes thinner than 20 nm. In this regime we extract a strain gradient elastic coupling of ∼2.2 μN, which could be used in new operational regimes of nanoelectro-mechanics.
- 10 March 2021
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 21 (6) , 2470-2475
Strain Gradient Elasticity in SrTiO3 Membranes: Bending versus Stretching
Young’s modulus determines the mechanical loads required to elastically stretch a material and also the loads required to bend it, given that bending stretches one surface while compressing the opposite one. Flexoelectric materials have the additional property of becoming electrically polarized when bent. The associated energy cost can additionally contribute to elasticity via strain gradients, particularly at small length scales where they are geometrically enhanced. Here, we present nanomechanical measurements of freely suspended SrTiO3 crystalline membrane drumheads. We observe an unexpected nonmonotonic thickness dependence of Young’s modulus upon small deflections. Furthermore, the modulus inferred from a predominantly bending deformation is three times larger than that of a predominantly stretching deformation for membranes thinner than 20 nm. In this regime we extract a strain gradient elastic coupling of ∼2.2 μN, which could be used in new operational regimes of nanoelectro-mechanics.
- 9 August 2020
- Published by Wiley in Advanced Functional Materials
- Vol. 30 (40)
Bioresorbable Wireless Sensors as Temporary Implants for In Vivo Measurements of Pressure
Pressures at targeted locations inside the human body serve as critically important diagnostic parameters for monitoring various types of serious or even potentially fatal medical conditions including intracranial, intra‐abdominal, and pulmonary hypertension, as well as compartment syndromes. Implantable commercial sensors provide satisfactory accuracy and stability in measurements of pressure, yet surgical removal is required after recovery of the patient to avoid infections and other risks associated with long‐term implantation. Sensors that dissolve in biofluids (or, equivalently, bioabsorb or bioresorb) avoid the need for such surgeries, yet current designs involve either hard‐wired connections and/or fail to provide quantitative measurements over clinically relevant lifetimes. Here, a bioresorbable, wireless pressure sensor based on passive inductor‐capacitor resonance circuits in layouts and with sets of materials that overcome these drawbacks is reported. Specifically, optimized designs offer sensitivity as high as ≈200 kHz mmHg−1 and resolution as low as 1 mmHg. Encapsulation approaches that use membranes of Si3N4 and edge seals of natural wax support stable operation in vivo for up to 4 days. The bioresorbable pressure sensing technology reported here may serve as an important solution to temporary, real‐time monitoring of internal pressure for various medical conditions.
- 9 August 2020
- Published by Wiley in Advanced Functional Materials
- Vol. 30 (40)
Bioresorbable Wireless Sensors as Temporary Implants for In Vivo Measurements of Pressure
Pressures at targeted locations inside the human body serve as critically important diagnostic parameters for monitoring various types of serious or even potentially fatal medical conditions including intracranial, intra‐abdominal, and pulmonary hypertension, as well as compartment syndromes. Implantable commercial sensors provide satisfactory accuracy and stability in measurements of pressure, yet surgical removal is required after recovery of the patient to avoid infections and other risks associated with long‐term implantation. Sensors that dissolve in biofluids (or, equivalently, bioabsorb or bioresorb) avoid the need for such surgeries, yet current designs involve either hard‐wired connections and/or fail to provide quantitative measurements over clinically relevant lifetimes. Here, a bioresorbable, wireless pressure sensor based on passive inductor‐capacitor resonance circuits in layouts and with sets of materials that overcome these drawbacks is reported. Specifically, optimized designs offer sensitivity as high as ≈200 kHz mmHg−1 and resolution as low as 1 mmHg. Encapsulation approaches that use membranes of Si3N4 and edge seals of natural wax support stable operation in vivo for up to 4 days. The bioresorbable pressure sensing technology reported here may serve as an important solution to temporary, real‐time monitoring of internal pressure for various medical conditions.