ZPZoltán Perkó

Zoltán Perkó

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zoltán Perkó has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Direct probabilistic IMPT treatment planning with setup and range errors for neuro-oncological patients

    by J R de Jong, S Breedveld, S J M Habraken, M S Hoogeman, J I de Jong, D Lathouwers, Z Perkó

    Objective . To show computational feasibility of a previously proposed probabilistic planning approach on a neuro-oncological patient group, we compared probabilistic plans with (automated) robust plans for one patient (group A) that could achieve sufficient clinical target coverage and for four patients (group B) where target coverage had to be compromised due to organ-at-risk (OAR) dose constraints. Approach . The probabilistic approach is percentile-based and uses the fact that a (dose) percentile can be approximated as a linear combination of its expected value and standard deviation. This allows us to formulate objectives and constraints with patient-specific acceptance probabilities. The optimization has a nested structure: the inner optimization optimizes the beam weights for a given percentile estimate, while an outer loop iteratively updates and improves the accuracy of the percentile estimate. For every outer iteration, the optimization is warm-started from the previous iteration. Percentiles are efficiently calculated by sampling a polynomial chaos expansion of the dose-influence matrix. Main results . The patient in group A achieved cumulative OAR dose reductions (of OAR-related DVH-metrics) of 23.1 GyRBE, for identical target coverage. Target coverage improved for all patients in group B (the 10th percentile of D 99.8 % increased up to 0.61 GyRBE), at the same time reaching cumulative OAR dose reductions (of OAR-related DVH-metrics) up to about 40 GyRBE. Probabilistic plans were optimized in 44 h to 226 h. For two representative patients, eliminating warm-starting (i.e. the outer loop) from the approach reduced total optimization times to below 10 h (which took originally 80 h and 141 h). Significance . Compared to robust optimization methods, the probabilistic approach achieves improved trade-offs between probabilistic target coverage and OAR sparing, potentially leading to better treatments.

  • Open Access

    A deep learning-based surrogate model for Severe Accidents in nuclear reactors using ASTEC

    by Alessandro Longhi, Danny Lathouwers, Zoltán Perkó

  • Open Access

    Uncertainty analysis in hyperthermia treatment planning for head & neck cancer using polynomial Chaos expansion

    by Roel C Kwakernaak, Massimiliano Zanoli, Zoltan Perkó, Margarethus M Paulides, Sergio Curto

    Objective: Hyperthermia, the elevation of tumor temperature to 39 ∘ C–44 ∘ C, is an effective adjuvant treatment for head and neck (H&N) cancer, enhancing the effects of radiotherapy and chemotherapy. This study investigates the robustness of hyperthermia treatment planning (HTP) for H&N cancer using the HyperCollar3D applicator, focusing on uncertainties in patient positioning, tissue properties, and water bolus cooling efficacy. Approach: A retrospective analysis was conducted of 16 patients treated at the Erasmus medical center, utilizing polynomial chaos expansion to model the impact of uncertainties on temperature distributions and treatment quality metrics. Main results: Our findings indicate significant variability in target temperatures due to uncertainties in these tissue properties (2.1 ∘ C T 90 95% confidence interval), further exacerbated by patient positioning errors (2.3 ∘ C T 90 95% confidence interval for 5 mm positioning errors). Uncertainty in dielectric tissue properties causes the largest chunk of the variance (47%) in T 90 followed by positioning errors (22%). Significance: This study highlights the critical importance of accurate measurement of tissue properties and precise patient positioning to achieve effective hyperthermia treatment outcomes. Our findings strongly advocate the development of more robust and quantitative treatment planning and delivery approaches, aiming to enhance the precision and clinical efficacy of HTP protocols for H&N cancer treatments.

  • Open Access

    Probabilistic proton treatment planning: a novel approach for optimizing underdosage and overdosage probabilities of target and organ structures

    by J R de Jong, S Breedveld, S J M Habraken, M S Hoogeman, D Lathouwers, Z Perkó

    Objective . Uncertainties in treatment planning are typically managed using either margin-based or robust optimization. Margin-based methods expand the clinical target volume (CTV) towards a planning target volume, which is generally unsuited for proton therapy. Robust optimization considers worst-case scenarios, but its quality depends on the chosen uncertainty (scenario) set : excluding extremes reduces robustness, while including too many make plans overly conservative. Probabilistic optimization overcomes these limitations by modeling a continuous scenario distribution, enabling the use of statistical measures. Approach . We propose a novel approach to probabilistic optimization that steers plans towards individualized probability levels, to control CTV and organs-at-risks (OARs) under- and overdosage. Voxel-wise dose percentiles ( d ) are estimated by expected value ( E ) and standard deviation (SD) as E ± δ ⋅ SD , where δ is iteratively tuned to match the target percentile of the underlying probability distribution (given setup and range uncertainties). The approach involves an inner optimization of E ± δ ⋅ SD for fixed δ , and an outer optimization loop that updates δ . Polynomial chaos expansion provides accurate and efficient dose estimates during optimization. We validated the method on a spherical CTV (prescribed 60 Gy) abutted by an OAR in different directions and a horseshoe-shaped CTV surrounding a cylindrical spine, under Gaussian-distributed setup (3 mm) and range (3%) uncertainties. Main results . For spherical cases with similar CTV coverage, P ( D 2 % > 30 Gy ) dropped by 10%–15%; for matched OAR dose, P ( D 98 % > 57 Gy ) increased by 67.5%–71%. In spinal plans, P ( D 98 % > 57 Gy ) increased by 10%–15% while P ( D 2 % > 30 Gy ) dropped by 24%–28% in the same plan. Probabilistic and robust optimization times were comparable for spherical (hours) but longer for spinal cases (7.5–11.5 h vs 9–20 min). Significance . Compared to discrete scenario-based optimization, the probabilistic approach offered better OAR sparing or target coverage, depending on individualized priorities.


  • Probabilistic evaluation guided IMPT planning with realistic setup and range uncertainties improves the trade-off between OAR sparing and target coverage in neuro-oncological patients

    by Jenneke I. de Jong, Steven J.M. Habraken, Jesús Rojo-Santiago, Danny Lathouwers, Zoltán Perkó, Sebastiaan Breedveld, Mischa S. Hoogeman


  • Open Access

    A deep learning model for inter-fraction head and neck anatomical changes in proton therapy

    by Tiberiu Burlacu, Mischa Hoogeman, Danny Lathouwers, Zoltán Perkó

    Objective. To assess the performance of a probabilistic deep learning based algorithm for predicting inter-fraction anatomical changes in head and neck patients. Approach. A probabilistic daily anatomy model (DAM) for head and neck patients DAM (DAMHN) is built on the variational autoencoder architecture. The model approximates the generative joint conditional probability distribution of the repeat computed tomography (rCT) images and their corresponding masks on the planning CT images (pCT) and their masks. The model outputs deformation vector fields, which are used to produce possible rCTs and associated masks. The dataset is composed of 93 patients (i.e. 315 pCT–rCT pairs), 9 (i.e. 27 pairs) of which were set aside for final testing. The performance of the model is assessed based on the reconstruction accuracy and the generative performance for the set aside patients. Main results. The model achieves a DICE score of 0.83 and an image similarity score normalized cross-correlation of 0.60 on the test set. The generated parotid glands, spinal cord and constrictor muscle volume change distributions and center of mass shift distributions were also assessed. For all organs, the medians of the distributions are close to the true ones, and the distributions are broad enough to encompass the real observed changes. Moreover, the generated images display anatomical changes in line with the literature reported ones, such as the medial shifts of the parotids glands. Significance. DAMHN is capable of generating realistic anatomies observed during the course of the treatment and has applications in anatomical robust optimization, treatment planning based on plan library approaches and robustness evaluation against inter-fractional changes.


  • Open Access

    Yet anOther Dose Algorithm (YODA) for independent computations of dose and dose changes due to anatomical changes

    by Tiberiu Burlacu, Danny Lathouwers, Zoltán Perkó

    Objective. To assess the viability of a physics-based, deterministic and adjoint-capable algorithm for performing treatment planning system independent dose calculations and for computing dosimetric differences caused by anatomical changes. Approach. A semi-numerical approach is employed to solve two partial differential equations for the proton phase-space density which determines the deposited dose. Lateral hetereogeneities are accounted for by an optimized (Gaussian) beam splitting scheme. Adjoint theory is applied to approximate the change in the deposited dose caused by a new underlying patient anatomy. Main results. The dose engine’s accuracy was benchmarked through three-dimensional gamma index comparisons against Monte Carlo simulations done in TOPAS. For a lung test case, the worst passing rate with (1 mm, 1%, 10% dose cut-off) criteria is 94.55%. The effect of delivering treatment plans on repeat CTs was also tested. For non-robustly optimized plans the adjoint component was accurate to 5.7% while for a robustly optimized plan it was accurate to 4.8%. Significance. Yet anOther Dose Algorithm is capable of accurate dose computations in both single and multi spot irradiations when compared to TOPAS. Moreover, it is able to compute dosimetric differences due to anatomical changes with small to moderate errors thereby facilitating its use for patient-specific quality assurance in online adaptive proton therapy.


  • Open Access

    A probabilistic evaluation of the Dutch robustness and model-based selection protocols for Head-and-Neck IMPT: A multi-institutional study

    by Jesús Rojo-Santiago, Steven J.M. Habraken, Mirko Unipan, Stefan Both, Geert Bosmans, Zoltán Perkó, Erik Korevaar, Mischa S. Hoogeman


  • Open Access

    A fast and robust constraint-based online re-optimization approach for automated online adaptive intensity modulated proton therapy in head and neck cancer

    by Michelle Oud, Sebastiaan Breedveld, Jesús Rojo-Santiago, Marta Krystyna Giżyńska, Michiel Kroesen, Steven Habraken, Zoltán Perkó, Ben Heijmen, Mischa Hoogeman

    Objective . In head-and-neck cancer intensity modulated proton therapy, adaptive radiotherapy is currently restricted to offline re-planning, mitigating the effect of slow changes in patient anatomies. Daily online adaptations can potentially improve dosimetry. Here, a new, fully automated online re-optimization strategy is presented. In a retrospective study, this online re-optimization approach was compared to our trigger-based offline re-planning (offline TB re-planning) schedule, including extensive robustness analyses. Approach . The online re-optimization method employs automated multi-criterial re-optimization, using robust optimization with 1 mm setup-robustness settings (in contrast to 3 mm for offline TB re-planning). Hard planning constraints and spot addition are used to enforce adequate target coverage, avoid prohibitively large maximum doses and minimize organ-at-risk doses. For 67 repeat-CTs from 15 patients, fraction doses of the two strategies were compared for the CTVs and organs-at-risk. Per repeat-CT, 10.000 fractions with different setup and range robustness settings were simulated using polynomial chaos expansion for fast and accurate dose calculations. Main results . For 14/67 repeat-CTs, offline TB re-planning resulted in D 98% ≥ 95% of the prescribed dose ( D pres ) in one or both CTVs, which never happened with online re-optimization. With offline TB re-planning, eight repeat-CTs had zero probability of obtaining D 98% ≥ 95% D pres for CTV 7000 , while the minimum probability with online re-optimization was 81%. Risks of xerostomia and dysphagia grade ≥ II were reduced by 3.5 ± 1.7 and 3.9 ± 2.8 percentage point [mean ± SD] ( p < 10 −5 for both). In online re-optimization, adjustment of spot configuration followed by spot-intensity re-optimization took 3.4 min on average. Significance . The fast online re-optimization strategy always prevented substantial losses of target coverage caused by day-to-day anatomical variations, as opposed to the clinical trigger-based offline re-planning schedule. On top of this, online re-optimization could be performed with smaller setup robustness settings, contributing to improved organs-at-risk sparing.