VAVarun Arya

Varun Arya

*This is an algorithmically generated author record based on publicly available information.

Varun Arya has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparative Analysis of Microneedling With PRP Versus Vitamin C Serum in the Management of Post-Operative Cleft lip Scars

    by Sameera Dawar, Manu Gupta, Varun Arya, Sanjeev Kumar

    Objective: The present study was conducted with the objective of comparing the efficacy of microneedling with vitamin C serum versus platelet-rich plasma (PRP) in the management of the appearance of post-operative cleft lip scars. Design: The study was conducted as a prospective, randomized comparative study. Participants: A total of 30 participants ( n = 30) were included in the study, with each group comprising of 15 participants. Setting: Smile train verified cleft center. Intervention: Each patient underwent three sessions of microneedling combined with the assigned adjuvant, PRP in group A and vitamin C serum in group B. Follow-up evaluations were conducted at 1, 2, and 3 months post-operatively. Main Outcome Measures: The scar quality and improvements were assessed using the patient and observer scar assessment scale (POSAS), graded from 1 to 10 by each patient and a fixed outer observer from the department of oral and maxillofacial surgery. p ≤ 0.5 was considered statistically significant. Results: Results indicated that while both modalities offer significant improvements in scar appearance, texture, and overall esthetic outcomes, PRP showed superior results in terms of scar reduction and patient-reported satisfaction ( p < 0.05). However, pliability ( p = 0.10) and pain ( p = 0.28) scores did not show a statistically significant difference between the two groups. Conclusion: Through this study, we concluded that microneedling when combined with PRP offers far more superior results in terms of improvement of the scar appearance as compared to vitamin C serum.

  • Malacoplakia of Tongue: A Rare Finding

    by Varun Arya, Sanjeev Kumar, Partishtha Sharma, Zenab Parveen, Kajol Gupta

  • Open Access

    Management of patients with allergy to local anesthetics: two case reports

    by Varun Arya, Geetanjali Arora, Sanjeev Kumar, Amrita Kaur, Santosh Mishra

    Arya V, et al. J Dent Anesth Pain Med. 2021 Dec;21(6):583-587. https://doi.org/10.17245/jdapm.2021.21.6.583


  • Management of Early Stage Carcinoma of the Oral Tongue: A Case Report and Review of Current Treatment Algorithms

    by Kashyap Rahul, Siwach Vijay, Kumar Jitender, Arya Varun, Anil K Sheorain, Megha Gupta

    Early stage squamous cell carcinoma (SCC) of the oral cavity has always remained a controversy when it comes to management. While one line of thought has always been towards conservative management limited to Wide Excision of the primary tumour and only observation for the neck, the opposing view is of an aggressive approach involving management of the primary along with neck and the need for Post Operative Adjuvant Therapy (PORT) as and when indicated. Certain subsites within the oral cavity, especially the oral tongue and Floor of Mouth (FOM) present further challenges to this controversy. The presence of higher number of lymphatic channels along with the reported phenomenon of “occult” and “skip” metastasis add fuel to fire. Most of the local or regional failures in treatment when only the primary is addressed are reported within the first 24 months of the primary treatment. As opposed to simple observation various treatment modalities have been suggested for the management of the neck namely elective neck dissection (END) and elective neck irradiation (ENR). Further, the limit of neck dissection, that is, the levels of lymph nodes excised, have also been suggested. Here we present a case report of a of biopsy proven early SCC of the oral tongue with no cervical metastasis in a 45 year female patient and highlight the various opinions expressed in literature regarding the management of such lesions.

  • Open Access

    Evaluation of the sternoclavicular graft for the reconstruction of temporomandibular joint after gap arthroplasty

    by Aadya Sharma, Jk Dayashankara Rao, Nahida Dar, Anil K Sheorain, Vijaylaxmi Malhotra, Varun Arya

    Introduction: Ankylosis may be defined as the fusion of the articular surfaces with bony or fibrous tissue. The treatment of temporomandibular joint ankylosis poses a significant challenge because of the high incidence of recurrence. A number of interpositional materials have been used including alloplastic materials (acrylic, proplast– teflon, silastic), and autogenous tissues (temporalis muscle flaps, buccal fat pad, dermis, costochondral grafts, metatarsal, fibula, tibia, iliac crest, cranial bone and Sternoclavicular graft SCG and cartilage). Literature suggests that rather than growth centre, we need adaptive centre. SCG is presumed to be a more suitable material for interpositional arthroplasty because Sternoclavicular Joint (SCJ) and TMJ are very similar developmentally, histologically and morphologically throughout the growth period. Material and Method: Patients with TMJ ankylosis (8 males, 2 females) underwent release of the ankylosed joint by the senior author, between June 2013 and Novemeber 2015. The age of the patients ranged from 10 to 19 years. Pre- and post- operative assessment included a thorough history and physical examination to determine the cause of ankylosis, the maximal incisal opening, etiology and type of the ankylosis, recurrence rate. Result: MIO at 6 months follow up was 37.4±2.633 mm (range 32-40 mm), greater than MIO achieved in immediate postoperatively {34.4±2.22 mm (range 30-38 mm). After reconstruction of temporomandibular joint with sternoclavicular graft in the growing child there was a significant increase in the growth of mandible which was stunned due to ankylosis. And the ramal height also increased. Conclusion: The articular reconstruction with alloplastic or autogenous grafts, or gap arthroplasty for the treatment of ankylosis is shown to be efficient in relation to the post-operative maximal incisal opening, recurrence and articular function.


  • Xylene Induced Facial Swelling: A Rare Case Report of Dental Negligence

    by Varun Arya, Jk Dayashankra Rao, Anil K Sheorain, Rahul Kashyap, Alok Bhatnagar, Jitender Phogat, Sheena Maria, Gaurav Bhati, Vikram Sharma, Chander Parkash

  • Open Access

    Evaluating the use of octyl-2-cyanoacrylate in unilateral cleft lip repair

    by Varun Arya, Vijaylaxmy Malhotra, Jk Dayashankara Rao, Shalender Sharma, Sushil Singh, Payal Luthra

    Background: Facial cosmetic results are one of the most concerning issues for the parents who get their children operated for cleft lip. Moreover, the postoperative care of the surgical site, the discomfort associated with the suture removal, and additional visit for suture removal are other reasons which encourages one to use any new technologies that may replace the need for suture placement. In this study, we used octyl-2-cyanoacrylate, a tissue adhesive which offers a viable alternative to traditional techniques without compromising optimal wound closure. Objective: To perform a comprehensive comparison of the outcomes from the use of Dermabond in patients undergoing primary repair of congenital cleft lip ± palate anomalies. Materials and Methods: Twenty patients, in the age group of 3–18 months were treated surgically for unilateral cleft lip deformity using Millard rotation-advancement flap. Pre- and post-operative photographs of the patients were taken at 1 week, 2 week, 1 month, 6 months, and 1 year postoperatively and were evaluated using Vancouver scar scale which was given by Sullivan in 1990. Paired t-test was used for statistical analysis. Results: Increased vascularity (hyperemia) was seen in the 1st and 2nd week in 35% and 30% patients, respectively which gradually reduced to normal in subsequent follow-ups. The scar was flat in 85% of patients in 1st week, and the number decreased to 10% at the end of 1 year. No wound dehiscence was found in any patients. Statistical analysis showed that among all the follow-ups, only the difference between the first and second follow-ups. Comparison of the results of 1 week with all other follow-ups yielded no significant results. Conclusion: Octyl-2-cyanoacrylate can be used for cleft lip closure effectively. The procedure is relatively painless and quick. Added to this are benefits of protection from wound infection since the material is bacteriostatic.


  • Retracted
    Open Access

    6-0 nylon versus 6-0 vicryl rapide in chieloplasty

    by Payal Luthra, J K. Dayashankara Rao, Varun Arya, Vijay Siwach, Anil K Sheorain, Megha Gupta

    Context: Facial cosmetic result is one of the most concerning issues for the parents who get their children operated for cleft lip. Moreover, the discomfort associated with the suture removal encourages one to use any new technology that may replace the need for suture placement. The type of suture material used in surgery has been a long-standing debate among surgeons. In this study, we compared rapidly absorbable suture material (Vicryl Rapide™) with nonabsorbable suture material (nylon). Aims: The aim of this study is to compare the appearance and course of scar, wound infection, and patient's parent perception using Vicryl Rapide and nylon in nonsyndromic congenital cleft lip repair. Settings and Design: This was a randomized prospective controlled clinical trial. Materials and Methods: Twenty patients, in the age group of 3–18 months treated for unilateral congenital cleft lip deformity, were included and randomly allocated to two groups with ten patients each. Skin suturing was done with 6-0 polyamide and 6-0 irradiated polyglactin in Groups A and B, respectively. Patients were evaluated at 1 week, 1, 3, 6 months, and 1 year postoperatively in person by the observer as well as by the patient's parent. Statistical Analysis Used: Descriptive statistical analysis was done using SPSS 20, and Student's t-test was applied. Results: It was found that Vicryl Rapide showed more hypopigmented scars and raised scars than nylon at the end of 1 year though overall appearance was comparable between the groups. Conclusions: Vicryl Rapide showed poorer cosmetic outcomes in terms of height and pigmentation of car as compared to nylon suture of same thickness. However, since scars tend to improve with time, a bigger sample size and a longer follow-up are required to generalize this statement.


  • A Comparative Prospective Study of Two Bone Plating Methods for Fractures of the Mandibular Symphysis or Parasymphysis

    by Varun Arya, Sateesh Bhatele, Payal Luthra, Nahida Dar, Ashish Pilania, Priyanka Mudgal, Sunil Gulia

    Mandibular symphysis and parasymphysis fractures are a common type of injury to facial skeleton. The purpose of this prospective study was to evaluate outcomes for 2 bone plating techniques used in the treatment of mandibular symphysis/parasymphysis fractures. Thirty patients reporting to the department with mandibular symphysis/parasymphysis fractures were divided into 2 groups (group A and group B). A prospective study was carried out in 30 patients with defined inclusion and exclusion criteria. Patients were followed for 3 months postoperatively for occlusion, distraction of lower border radiologically, paraesthesia, infection, failure of bone plate (plate fracture) and screw loosening, postoperative segmental stability and radiological evaluation of fixation. Fifteen patients were treated by open reduction and single miniplate fixation below apices of teeth with arch bar acting as tension band (Group A) and 15 with conventional titanium miniplates following Champy's rule i.e. Two miniplates (Group B). Distraction of lower border was seen in both groups (as in group A-1 patient and group B-2 patients), which was noticed radiographically at all follow ups. There was no occlusal discrepancy present in both groups after 3 months post operatively. The fracture segments were stable in both groups at all times. Paraesthesia was noticed in both groups, which gradually decreased in 1 month and resolved completely by 3rd month follow up. The degree of paraesthesia, distraction of lower border, occlusal discrepancy was not statistically significant between the two groups. Infection was noticed in both groups at the end of 2 weeks, which was treated with antibiotics. The result between both the groups was not significant though. Hardware failure (plate fracture and screw loosening) was not found in both groups. Osteosynthesis by both techniques is effective in providing immediate post operative function but the distinct advantage of less hardware has made the use of a single miniplate quite popular in the recent times.

  • Comparative analysis of 6-0 nylon and 6-0 vicryl rapide in congenital unilateral cleft lip repair

    by Payal Luthra, Jk Dayashankara Rao, Varun Arya, Vijay Siwach, Anil Sheorain, Priyanka Mudgal

    Context: The type of suture material used in surgery has been a long standing debate among surgeons. In this study we compared rapidly absorbable suture material (Vicryl Rapide TM or Irradiated Polygalactin 910) with non-absorbable suture material (Nylon or Polyamide) in patients with nonsyndromic congenital unilateral cleft lip. Aims: To compare the appearance and course of scar, wound infection and patient's parent perception between the two groups. Settings and Design: Randomized prospective controlled study. Methods and Material: 20 patients, in the age group of 3-18 months were randomly allocated to two groups with 10 patients each. Skin suturing was done with 6-0 Polyamide and 6-0 Irradiated polygalactin the respective groups. Patients were evaluated at 1 week, 1 month, 3 months, 6 months and 1 year postoperatively by the observer as well as by the patient's parent. Results and Conclusion: It was found that Vicryl Rapide showed poorer cosmetic outcomes regarding height and pigmentation of scar as compared to nylon sutures.However, this sample size and follow-up period is very small to generalize these findings.