Daniela Maffiodo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniela Maffiodo has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Carlo Ferraresi
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
20 shared publications - Carlo De Benedictis
Politecnico di Torino
18 shared publications - Daniel Pacheco Quiñones
Politecnico di Torino
12 shared publications - Walter Franco
Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
11 shared publications - Silvestro Roatta
Department of Neuroscience, University of Torino, Turin, Italy
10 shared publications Carlo Ferraresi
Politecnico di Torino
8 shared publications
Latest Publications
- 16 September 2026
- Published by Springer Nature
- p. 516-525
Environmental Monitoring System for Rescue Operations in Artesian Wells
- 16 September 2026
- Published by Springer Nature
- p. 516-525
Environmental Monitoring System for Rescue Operations in Artesian Wells
- 7 July 2026
- Published by Springer Nature
- p. 185-193
A Low-Cost Inertial Framework for Dynamic Posturography: From Preliminary Validation to Kinematic Integration
- 7 July 2026
- Published by Springer Nature
- p. 185-193
A Low-Cost Inertial Framework for Dynamic Posturography: From Preliminary Validation to Kinematic Integration
- Open Access
- 27 June 2026
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 228
Novel underactuated grippers with torque-driven bistable mechanism for alternating grasping and unlimited twisting modes
- 27 June 2026
- Published by Elsevier in Mechanism and Machine Theory
- Vol. 228
Open AccessNovel underactuated grippers with torque-driven bistable mechanism for alternating grasping and unlimited twisting modes
- Open Access
- 15 April 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (7) , 1-12
Effects of anthropometry, age and sex on center of pressure displacement evoked by small trunk perturbations in balance tests
Purpose: Balance control can be evaluated by studying the displacement of the center of pressure (CoP) during dynamic posturographic trials. However, differences in anthropometric characteristics may affect the measurement and increase intersubject variability, possibly leading to misinterpretation. This study evaluates how sex, age, and anthropometric characteristics (weight, height, and foot length) influence the CoP displacement to postural perturbations. Methods: Seventy-two healthy subjects, 31 women and 41 men, were subjected to five small impulsive perturbations applied to their back. Balance performance was quantified by three CoP parameters: the ratio between the maximum CoP displacement and the impulse of the perturbation (Δ CoP n ), the latency ( Lat ), and the duration ( Dur ) of the CoP response. Results: A linear regression analysis evidenced that body weight and height exhibited a negative and positive relation with Δ CoP n , respectively, which explained 48% of the Δ CoP n variability. These relations were confirmed by simulations with a single-link biomechanical model. On the other hand, the latency and the duration of the CoP response were affected neither by the anthropometric characteristics nor by sex. Conclusion: Findings from the present study have an impact on test protocols, especially when comparing data collected from heterogeneous populations, in which case normalization with respect to the subjects’ height and weight may be necessary to use the Δ CoP n as a postural performance index.
- 15 April 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (7) , 1-12
Open AccessEffects of anthropometry, age and sex on center of pressure displacement evoked by small trunk perturbations in balance tests
Purpose: Balance control can be evaluated by studying the displacement of the center of pressure (CoP) during dynamic posturographic trials. However, differences in anthropometric characteristics may affect the measurement and increase intersubject variability, possibly leading to misinterpretation. This study evaluates how sex, age, and anthropometric characteristics (weight, height, and foot length) influence the CoP displacement to postural perturbations. Methods: Seventy-two healthy subjects, 31 women and 41 men, were subjected to five small impulsive perturbations applied to their back. Balance performance was quantified by three CoP parameters: the ratio between the maximum CoP displacement and the impulse of the perturbation (Δ CoP n ), the latency ( Lat ), and the duration ( Dur ) of the CoP response. Results: A linear regression analysis evidenced that body weight and height exhibited a negative and positive relation with Δ CoP n , respectively, which explained 48% of the Δ CoP n variability. These relations were confirmed by simulations with a single-link biomechanical model. On the other hand, the latency and the duration of the CoP response were affected neither by the anthropometric characteristics nor by sex. Conclusion: Findings from the present study have an impact on test protocols, especially when comparing data collected from heterogeneous populations, in which case normalization with respect to the subjects’ height and weight may be necessary to use the Δ CoP n as a postural performance index.
- 5 October 2025
- Published by Springer Nature
- p. 156-164
Robotic Dynamic Posturography: A Validation Study Using IMU and Force Platform Data
- 5 October 2025
- Published by Springer Nature
- p. 156-164
Robotic Dynamic Posturography: A Validation Study Using IMU and Force Platform Data
- Open Access
Analysis and Evaluation of a Joint Path Planning Algorithm for the Quasi-Spherical Parallel Manipulator, a Master Device for Telesurgery
This work presents the experimental validation of a reset control mode for a Quasi-Spherical Parallel Manipulator (qSPM), designed as a master device for bilaterally teleoperated telesurgical systems. The reset functionality enables autonomous repositioning of the master device to its central configuration via a joint-space path planning algorithm, executed entirely within the local control loop. Given the non-convex nature of the joint space, the algorithm computes feasible trajectories using a simplified optimization scheme that ensures compliance with mechanical and kinematic constraints. The algorithm was implemented within an ROS Noetic framework and tested across multiple scenarios, including both simulated and physical configurations. The experimental results confirm the device’s ability to reset to the central position in approximately 5 s, maintaining an average residual error below . Computational evaluations demonstrate that each path is generated in less than 10 milliseconds, supporting real-time execution. Additional trials show successful motion toward arbitrary points within the joint space, suggesting the potential for future integration of user-driven repositioning features. These findings highlight the responsiveness, reliability, and experimental feasibility of the proposed control mode, marking a key step toward improving usability in telesurgical environments.Open AccessAnalysis and Evaluation of a Joint Path Planning Algorithm for the Quasi-Spherical Parallel Manipulator, a Master Device for Telesurgery
This work presents the experimental validation of a reset control mode for a Quasi-Spherical Parallel Manipulator (qSPM), designed as a master device for bilaterally teleoperated telesurgical systems. The reset functionality enables autonomous repositioning of the master device to its central configuration via a joint-space path planning algorithm, executed entirely within the local control loop. Given the non-convex nature of the joint space, the algorithm computes feasible trajectories using a simplified optimization scheme that ensures compliance with mechanical and kinematic constraints. The algorithm was implemented within an ROS Noetic framework and tested across multiple scenarios, including both simulated and physical configurations. The experimental results confirm the device’s ability to reset to the central position in approximately 5 s, maintaining an average residual error below . Computational evaluations demonstrate that each path is generated in less than 10 milliseconds, supporting real-time execution. Additional trials show successful motion toward arbitrary points within the joint space, suggesting the potential for future integration of user-driven repositioning features. These findings highlight the responsiveness, reliability, and experimental feasibility of the proposed control mode, marking a key step toward improving usability in telesurgical environments. - 11 July 2025
- Published by Springer Nature
- p. 74-81
Workbench Statics Evaluation of the Quasi-Spherical Parallel Manipulator
- 11 July 2025
- Published by Springer Nature
- p. 74-81
Workbench Statics Evaluation of the Quasi-Spherical Parallel Manipulator
- Open Access
- 23 September 2024
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (6) , 1955-1980
Kinematic analysis, workspace definition, and self-collision avoidance of a quasi-spherical parallel manipulator
Bilateral teleoperation has witnessed significant development since the mid-20th century, a23ressing challenges related to human presence in environments with constraints or a lack of skilled professionals. This article presents the kinematic and self-collision analyses of the quasi-spherical parallel manipulator, a three-legged parallel robot used as a haptic master device. The device is designed for remote center of motion-constrained operation in the telesurgical field. Inverse and forward kinematics are thoroughly analyzed to study working modes, singular configurations, and implement a haptic control architecture. The research explores the operative and reachable workspaces of the possible working modes, comparing them to find the most suitable one. Results highlight how the addition of the self-collision phenomenon impacts the working mode choice, drastically reducing most of the modes’ operative workspaces. An anti-collision control algorithm is finally introduced to maintain the architecture within its reachable workspace.
- 23 September 2024
- Published by Cambridge University Press (CUP) in Robotica
- Vol. 43 (6) , 1955-1980
Open AccessKinematic analysis, workspace definition, and self-collision avoidance of a quasi-spherical parallel manipulator
Bilateral teleoperation has witnessed significant development since the mid-20th century, a23ressing challenges related to human presence in environments with constraints or a lack of skilled professionals. This article presents the kinematic and self-collision analyses of the quasi-spherical parallel manipulator, a three-legged parallel robot used as a haptic master device. The device is designed for remote center of motion-constrained operation in the telesurgical field. Inverse and forward kinematics are thoroughly analyzed to study working modes, singular configurations, and implement a haptic control architecture. The research explores the operative and reachable workspaces of the possible working modes, comparing them to find the most suitable one. Results highlight how the addition of the self-collision phenomenon impacts the working mode choice, drastically reducing most of the modes’ operative workspaces. An anti-collision control algorithm is finally introduced to maintain the architecture within its reachable workspace.
- Open Access
Assistive Control through a Hapto-Visual Digital Twin for a Master Device Used for Didactic Telesurgery
This article explores the integration of a hapto-visual digital twin on a master device used for bilateral teleoperation. The device, known as a quasi-spherical parallel manipulator, is currently employed for the remote center of motion control in teleoperated mini-invasive surgery. After providing detailed insights into the device’s kinematics, including its geometric configuration, Jacobian, and reachable workspace, the paper illustrates the overall control system, encompassing both hardware and software components. The article describes how a digital twin, which implements a haptic assistive control and a visually enhanced representation of the device, was integrated into the system. The digital twin was then tested with the device: in the experiments, one “student” end-user must follow a predefined “teacher” trajectory. Preliminary results demonstrate how the overall system can pose a good starting point for didactic telesurgery operation. The control action, yet to be optimized and tested on different subjects, indeed seems to grant satisfying performance and accuracy.
Open AccessAssistive Control through a Hapto-Visual Digital Twin for a Master Device Used for Didactic Telesurgery
This article explores the integration of a hapto-visual digital twin on a master device used for bilateral teleoperation. The device, known as a quasi-spherical parallel manipulator, is currently employed for the remote center of motion control in teleoperated mini-invasive surgery. After providing detailed insights into the device’s kinematics, including its geometric configuration, Jacobian, and reachable workspace, the paper illustrates the overall control system, encompassing both hardware and software components. The article describes how a digital twin, which implements a haptic assistive control and a visually enhanced representation of the device, was integrated into the system. The digital twin was then tested with the device: in the experiments, one “student” end-user must follow a predefined “teacher” trajectory. Preliminary results demonstrate how the overall system can pose a good starting point for didactic telesurgery operation. The control action, yet to be optimized and tested on different subjects, indeed seems to grant satisfying performance and accuracy.
- 1 August 2024
- Published by Springer Nature
- p. 511-519
Low Cost Space Shuttle Simulator Supported by Air Bearings
- 1 August 2024
- Published by Springer Nature
- p. 511-519
Low Cost Space Shuttle Simulator Supported by Air Bearings