Akram Sheikhi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Akram Sheikhi has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Abdolali Abdipour
Department of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
4 shared publications - Maryam Bazgir
Lorestan University
4 shared publications - Mohammad Bagher Dowlatshahi
Department of Computer Engineering, Faculty of Engineering, Lorestan University, Khorramabad, Iran
4 shared publications - Mohsen Hayati
Department of Electrical Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran
4 shared publications Abbas Alipour
Department of Electronics, Faculty of Engineering, Lorestan University, Khorram-Abad, Iran
3 shared publications- Andrei Grebennikov
Sumitomo Electric Europe Ltd., Elstree, U.K.
3 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27996-28004
Multimode Near-Infrared Refractive Index Biosensor Based on Graphene-Integrated Split Elliptical-in-Square Metamaterial
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27996-28004
Multimode Near-Infrared Refractive Index Biosensor Based on Graphene-Integrated Split Elliptical-in-Square Metamaterial
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (9) , 7923-7934
A Dual-Band Doherty Power Amplifier With Enhanced Efficiency and Simplified Output Network
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (9) , 7923-7934
A Dual-Band Doherty Power Amplifier With Enhanced Efficiency and Simplified Output Network
- 2 January 2026
- Published by Springer Nature
- p. 3-19
Nature-Inspired Algorithms for Optimization of Microwave Circuits: Applications in Filters and Amplifiers
- 2 January 2026
- Published by Springer Nature
- p. 3-19
Nature-Inspired Algorithms for Optimization of Microwave Circuits: Applications in Filters and Amplifiers
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 1-24
A Review on ANN-Based Behavioral Modeling Techniques for High-Efficiency Power Amplifiers
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 1-24
A Review on ANN-Based Behavioral Modeling Techniques for High-Efficiency Power Amplifiers
- Open Access
- 18 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Development of a high-sensitivity multimode graphene-based metamaterial biosensor with a double-split elliptical resonator for refractive index sensing and biomedical applications
This paper introduces a high-sensitivity, multimode graphene-based metamaterial (MM) biosensor for refractive index sensing, featuring a periodic array of gold (Au) double-split elliptical resonators (DSERs) on a graphene-coated silicon dioxide (SiO₂) substrate with an Au reflective base layer. The proposed design is analyzed using finite-difference time-domain (FDTD) simulations. The unique double-split elliptical geometry significantly enhances electromagnetic field confinement and enables the excitation of multiple distinct resonance modes, outperforming conventional circular or rectangular resonators that typically support only single- or dual-mode responses. The novelty of this work lies in the integration of a graphene–metal hybrid structure that combines tunable plasmonic properties of graphene with strong localized surface plasmon resonances of DSERs, resulting in multimode operation, improved tunability, and superior sensing performance. The bottom gold layer effectively suppresses transmission and reinforces field confinement within the active region. The sensor operates across 650–1500 nm, supporting five well-separated resonance modes that provide multiple sensing channels, enhancing detection efficiency and spectral flexibility. Optimized structural parameters such as the Au array thickness, SiO₂ layer thickness, and resonator width further improve its performance. The biosensor achieves a maximum sensitivity of 714.28 nm/RIU, a figure of merit (FoM) of 51.02 1/RIU, and a quality factor (QF) of 73.42 for breast cancer cell detection. Moreover, it successfully distinguishes between normal and cancerous cells (basal, breast, and cervical), demonstrating its strong potential for biomedical diagnostics and optical sensing applications. These results position the proposed multimode graphene-based biosensor as a promising platform for next-generation photonic and biomedical sensing technologies.
- 18 December 2025
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessDevelopment of a high-sensitivity multimode graphene-based metamaterial biosensor with a double-split elliptical resonator for refractive index sensing and biomedical applications
This paper introduces a high-sensitivity, multimode graphene-based metamaterial (MM) biosensor for refractive index sensing, featuring a periodic array of gold (Au) double-split elliptical resonators (DSERs) on a graphene-coated silicon dioxide (SiO₂) substrate with an Au reflective base layer. The proposed design is analyzed using finite-difference time-domain (FDTD) simulations. The unique double-split elliptical geometry significantly enhances electromagnetic field confinement and enables the excitation of multiple distinct resonance modes, outperforming conventional circular or rectangular resonators that typically support only single- or dual-mode responses. The novelty of this work lies in the integration of a graphene–metal hybrid structure that combines tunable plasmonic properties of graphene with strong localized surface plasmon resonances of DSERs, resulting in multimode operation, improved tunability, and superior sensing performance. The bottom gold layer effectively suppresses transmission and reinforces field confinement within the active region. The sensor operates across 650–1500 nm, supporting five well-separated resonance modes that provide multiple sensing channels, enhancing detection efficiency and spectral flexibility. Optimized structural parameters such as the Au array thickness, SiO₂ layer thickness, and resonator width further improve its performance. The biosensor achieves a maximum sensitivity of 714.28 nm/RIU, a figure of merit (FoM) of 51.02 1/RIU, and a quality factor (QF) of 73.42 for breast cancer cell detection. Moreover, it successfully distinguishes between normal and cancerous cells (basal, breast, and cervical), demonstrating its strong potential for biomedical diagnostics and optical sensing applications. These results position the proposed multimode graphene-based biosensor as a promising platform for next-generation photonic and biomedical sensing technologies.
- Open Access
- 25 September 2025
- Published by Springer Nature in Research Square
Development of a High-Sensitivity Multimode Graphene-Based Metamaterial Biosensor with a Double-Split Elliptical Resonator for Refractive Index Sensing and Biomedical Applications
This paper presents a high-sensitivity, multimode graphene-based metamaterial (MM) biosensor for refractive index sensing, utilizing a periodic array of gold (Au) double-split elliptical resonators (DSERs) on a graphene-coated silicon dioxide (SiO₂) substrate with an Au base layer. Finite-difference time-domain (FDTD) simulations confirm that the double-split elliptical design enhances field confinement and supports the excitation of multiple distinct resonance modes, offering an improvement over traditional circular or rectangular resonators. The sensor operates within the 650–1500 nm reflection range, supporting five distinct resonance modes that provide multiple sensing pathways, thereby improving detection efficiency compared to standard single-mode plasmonic sensors. Optimal performance is achieved by precisely tuning critical structural parameters, such as the thickness of the gold array and the SiO₂ layer, as well as the resonator width. According to the results, the proposed design is sensitive to the surrounding medium and can be used as a refractive index sensor. This sensing mechanism can be applied in a wide range of biomedical applications, including the differentiation between normal and cancerous cells. In the proposed design, three types of cancerous cells (basal, breast, and cervical) are used as test samples to evaluate the biosensor’s performance. The results show that the biosensor outperforms many existing designs reported in the literature. Specifically, for breast cancer cells, it achieves a maximum sensitivity of 714.28 nm/RIU, a figure of merit (FoM) of 51.02 1/RIU, and a quality factor (QF) of 73.42. These findings highlight the potential of the proposed biosensor as a promising candidate for future optical sensing technologies, advanced medical diagnostics, and a wide range of biomedical applications.
- 25 September 2025
- Published by Springer Nature in Research Square
Open AccessDevelopment of a High-Sensitivity Multimode Graphene-Based Metamaterial Biosensor with a Double-Split Elliptical Resonator for Refractive Index Sensing and Biomedical Applications
This paper presents a high-sensitivity, multimode graphene-based metamaterial (MM) biosensor for refractive index sensing, utilizing a periodic array of gold (Au) double-split elliptical resonators (DSERs) on a graphene-coated silicon dioxide (SiO₂) substrate with an Au base layer. Finite-difference time-domain (FDTD) simulations confirm that the double-split elliptical design enhances field confinement and supports the excitation of multiple distinct resonance modes, offering an improvement over traditional circular or rectangular resonators. The sensor operates within the 650–1500 nm reflection range, supporting five distinct resonance modes that provide multiple sensing pathways, thereby improving detection efficiency compared to standard single-mode plasmonic sensors. Optimal performance is achieved by precisely tuning critical structural parameters, such as the thickness of the gold array and the SiO₂ layer, as well as the resonator width. According to the results, the proposed design is sensitive to the surrounding medium and can be used as a refractive index sensor. This sensing mechanism can be applied in a wide range of biomedical applications, including the differentiation between normal and cancerous cells. In the proposed design, three types of cancerous cells (basal, breast, and cervical) are used as test samples to evaluate the biosensor’s performance. The results show that the biosensor outperforms many existing designs reported in the literature. Specifically, for breast cancer cells, it achieves a maximum sensitivity of 714.28 nm/RIU, a figure of merit (FoM) of 51.02 1/RIU, and a quality factor (QF) of 73.42. These findings highlight the potential of the proposed biosensor as a promising candidate for future optical sensing technologies, advanced medical diagnostics, and a wide range of biomedical applications.
- Open Access
- 28 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 27477
A novel approach of branch-line coupler via parallel transmission line and DGS
This article presents the design, simulation, and experimental validation of an ultra-compact 3-dB microstrip coupler with significantly reduced dimensions. The primary objective of this study is to develop a miniaturized coupler while maintaining high performance in terms of return loss, insertion loss, and phase balance. To achieve this, the proposed design employs parallel transmission lines, where shorter lines are directly integrated into the circuit, and longer lines are implemented as spiral structures to optimize space utilization. Additionally, a defected ground structure (DGS) is incorporated to further reduce the coupler's footprint and facilitate the implementation of high-impedance transmission lines. Since high-impedance microstrip lines require extremely narrow widths that are impractical due to fabrication constraints, the use of DGS effectively addresses this challenge by modifying the ground plane to achieve the desired impedance characteristics. The proposed coupler operates at a center frequency of 2.3 GHz and achieves a 75% size reduction compared to conventional designs. Experimental results demonstrate a return loss of approximately - 15 dB, a fractional bandwidth (FBW) of around 10.5%, and a consistent [Formula: see text] phase difference between output ports across a wide frequency range. The agreement between mathematical analysis, full-wave simulations, and fabricated prototype measurements validates the effectiveness of this approach. The compact size, minimal losses, and excellent phase and magnitude balance make this design a strong candidate for modern wireless communication and RF applications requiring high integration and efficiency.
- 28 July 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 27477
Open AccessA novel approach of branch-line coupler via parallel transmission line and DGS
This article presents the design, simulation, and experimental validation of an ultra-compact 3-dB microstrip coupler with significantly reduced dimensions. The primary objective of this study is to develop a miniaturized coupler while maintaining high performance in terms of return loss, insertion loss, and phase balance. To achieve this, the proposed design employs parallel transmission lines, where shorter lines are directly integrated into the circuit, and longer lines are implemented as spiral structures to optimize space utilization. Additionally, a defected ground structure (DGS) is incorporated to further reduce the coupler's footprint and facilitate the implementation of high-impedance transmission lines. Since high-impedance microstrip lines require extremely narrow widths that are impractical due to fabrication constraints, the use of DGS effectively addresses this challenge by modifying the ground plane to achieve the desired impedance characteristics. The proposed coupler operates at a center frequency of 2.3 GHz and achieves a 75% size reduction compared to conventional designs. Experimental results demonstrate a return loss of approximately - 15 dB, a fractional bandwidth (FBW) of around 10.5%, and a consistent [Formula: see text] phase difference between output ports across a wide frequency range. The agreement between mathematical analysis, full-wave simulations, and fabricated prototype measurements validates the effectiveness of this approach. The compact size, minimal losses, and excellent phase and magnitude balance make this design a strong candidate for modern wireless communication and RF applications requiring high integration and efficiency.
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Numerical Analysis of a High-Sensitivity Graphene-Based SPR Biosensor with a Split Elliptical Metamaterial Resonator for Hemoglobin Detection
This study presents a high-sensitivity graphene-based surface plasmon resonance (SPR) biosensor for hemoglobin detection, introducing a novel integration of a gold arc-shaped resonator (ASR) with a split elliptical-shaped resonator (SESR) on a graphene-coated SiO₂ substrate. Unlike traditional circular or rectangular resonators, the use of a split elliptical geometry enhances field confinement and enables the excitation of multiple distinct resonance modes, confirmed through finite-difference time-domain (FDTD) simulations. The sensor structure supports three prominent resonance modes within the 800–1800 nm reflection spectrum, offering multiple sensing channels and improved detection capabilities over conventional single-mode plasmonic sensors. Key geometric parameters, including the gold array thickness, resonator width, and SiO₂ layer thickness, are systematically optimized to maximize performance. Notably, mode 1 achieves a high sensitivity of 500 nm/RIU for hemoglobin refractive indices ranging from 1.36 to 1.39 (Δn = 0.03 RIU), with a figure of merit (FoM) of 41.66 1/RIU and a quality factor (QF) of 99.75. Mode 3 also demonstrates strong sensing potential, with 450 nm/RIU sensitivity, a FoM of 37.7 1/RIU, and a QF of 72.75. The incorporation of monolayer graphene further enhances plasmon-field coupling and tunability, offering significant improvements in detection sensitivity and fabrication feasibility. These results highlight the effectiveness and practical applicability of the proposed biosensor for advanced medical diagnostics and biomolecular sensing, marking a substantial advancement over previous SPR-based sensor designs.
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Numerical Analysis of a High-Sensitivity Graphene-Based SPR Biosensor with a Split Elliptical Metamaterial Resonator for Hemoglobin Detection
This study presents a high-sensitivity graphene-based surface plasmon resonance (SPR) biosensor for hemoglobin detection, introducing a novel integration of a gold arc-shaped resonator (ASR) with a split elliptical-shaped resonator (SESR) on a graphene-coated SiO₂ substrate. Unlike traditional circular or rectangular resonators, the use of a split elliptical geometry enhances field confinement and enables the excitation of multiple distinct resonance modes, confirmed through finite-difference time-domain (FDTD) simulations. The sensor structure supports three prominent resonance modes within the 800–1800 nm reflection spectrum, offering multiple sensing channels and improved detection capabilities over conventional single-mode plasmonic sensors. Key geometric parameters, including the gold array thickness, resonator width, and SiO₂ layer thickness, are systematically optimized to maximize performance. Notably, mode 1 achieves a high sensitivity of 500 nm/RIU for hemoglobin refractive indices ranging from 1.36 to 1.39 (Δn = 0.03 RIU), with a figure of merit (FoM) of 41.66 1/RIU and a quality factor (QF) of 99.75. Mode 3 also demonstrates strong sensing potential, with 450 nm/RIU sensitivity, a FoM of 37.7 1/RIU, and a QF of 72.75. The incorporation of monolayer graphene further enhances plasmon-field coupling and tunability, offering significant improvements in detection sensitivity and fabrication feasibility. These results highlight the effectiveness and practical applicability of the proposed biosensor for advanced medical diagnostics and biomolecular sensing, marking a substantial advancement over previous SPR-based sensor designs.
- 20 May 2025
- Published by Springer Nature
- p. 51-71
Optimization Techniques for Critical Issues in Power Amplifiers
- 20 May 2025
- Published by Springer Nature
- p. 51-71
Optimization Techniques for Critical Issues in Power Amplifiers