Guojun Niu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guojun Niu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bo Pan
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
3 shared publications Yili Fu
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China
3 shared publicationsCuicui Qu
Hangzhou SIASUN Robot & Automation CO. LTD., Hangzhou, 311200, China
2 shared publicationsFuhai Zhang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang, China
1 shared publicationHaibo Feng
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, Heilongjiang, China
1 shared publication- Tao Song
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, 150001, China
1 shared publication
Latest Publications
- Open Access
- 18 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 210513-210531
Global Asymptotic Nonlinear PID Control With a New Generalized Saturation Function
In order to solve the problem of the strict condition of traditional saturation function, a new generalized saturation function was proposed and applied in nonlinear PID (Proportion-Integration-Differentiation) control laws, which consisted of linear D + nonlinear PI and linear PD + nonlinear PI. The new generalized saturation function has powerful reaction near the equilibrium point, and has the capability to make the control converge to the equilibrium point swiftly. The global asymptotic stability condition of nonlinear PID control laws were derived by employing Lyapunov’s method and LaSalle’s invariance principle. In order to improve the accuracy of nonlinear PID control laws, time integration of the absolute value of position tracking error and time integration of the absolute value of torque error were chosen as the objective functions. Global asymptotic stability conditions and rated driving torque of each motor were set as the constraint conditions. Nonlinear PID controller parameters were tuned by employing multi-objective genetic algorithm, non-dominated sorted genetic algorithm-II (NSGA-II). Compared with the optimization results of nonlinear PID with traditional saturation function, the accuracy of position tracking using the proposed method was improved by nearly one order of magnitude. The new generalized saturation functions with minimum time integration of position tracking error were selected to study the robustness of the nonlinear PID controller in modeling uncertainty, input torque disturbance, and noise. The position tracking accuracy of the proposed method compared to those of the traditional PID controller and nonlinear PID controller with traditional saturation function was improved by nearly two orders of magnitude and one order of magnitude, respectively. The introduced saturation function significantly improves position tracking accuracy and robustness of the nonlinear PID controller.
- 18 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 210513-210531
Open AccessGlobal Asymptotic Nonlinear PID Control With a New Generalized Saturation Function
In order to solve the problem of the strict condition of traditional saturation function, a new generalized saturation function was proposed and applied in nonlinear PID (Proportion-Integration-Differentiation) control laws, which consisted of linear D + nonlinear PI and linear PD + nonlinear PI. The new generalized saturation function has powerful reaction near the equilibrium point, and has the capability to make the control converge to the equilibrium point swiftly. The global asymptotic stability condition of nonlinear PID control laws were derived by employing Lyapunov’s method and LaSalle’s invariance principle. In order to improve the accuracy of nonlinear PID control laws, time integration of the absolute value of position tracking error and time integration of the absolute value of torque error were chosen as the objective functions. Global asymptotic stability conditions and rated driving torque of each motor were set as the constraint conditions. Nonlinear PID controller parameters were tuned by employing multi-objective genetic algorithm, non-dominated sorted genetic algorithm-II (NSGA-II). Compared with the optimization results of nonlinear PID with traditional saturation function, the accuracy of position tracking using the proposed method was improved by nearly one order of magnitude. The new generalized saturation functions with minimum time integration of position tracking error were selected to study the robustness of the nonlinear PID controller in modeling uncertainty, input torque disturbance, and noise. The position tracking accuracy of the proposed method compared to those of the traditional PID controller and nonlinear PID controller with traditional saturation function was improved by nearly two orders of magnitude and one order of magnitude, respectively. The introduced saturation function significantly improves position tracking accuracy and robustness of the nonlinear PID controller.
- Open Access
- 28 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 177100-177111
Preoperative Planning Algorithm for Robot-Assisted Minimally Invasive Cholecystectomy Combined With Appendectomy
Preoperative planning for robot-assisted minimally invasive surgery is critical stage. Recently, many studies focus on the preoperative planning of the robot-assisted minimally invasive single-site surgery. However, the preoperative planning for the robot-assisted minimally invasive combined surgery based on the optimization algorithm has not been reported. In order to improve the dexterity and coordination of the manipulators in the surgical areas and to reduce the preoperative adjustment time for the combined surgery, this paper proposes a preoperative planning algorithm based on the non-dominated sorting genetic algorithm II (NSGA-II) for robot-assisted minimally invasive Cholecystectomy combined with Appendectomy (RAMICA). The preoperative planning algorithm simultaneously optimizes the entry ports and configurations of the manipulators. The optimization objective functions of the preoperative planning algorithm consist of a novel global dexterity index (GDI) based on the coefficient of variation and the coordination index (CI) that reflects hand-eye coordination and instrument coordination. The constraints of the preoperative planning algorithm include the port placement constraint and the non-collision constraint. The preoperative planning scheme based on the optimization algorithm are verified by comparative simulations to provide the better dexterity and coordination of the manipulators. Finally, the contrast experiments are carried out to demonstrate the effectiveness and superiority of the preoperative planning scheme obtained by the optimization algorithm.
- 28 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 177100-177111
Open AccessPreoperative Planning Algorithm for Robot-Assisted Minimally Invasive Cholecystectomy Combined With Appendectomy
Preoperative planning for robot-assisted minimally invasive surgery is critical stage. Recently, many studies focus on the preoperative planning of the robot-assisted minimally invasive single-site surgery. However, the preoperative planning for the robot-assisted minimally invasive combined surgery based on the optimization algorithm has not been reported. In order to improve the dexterity and coordination of the manipulators in the surgical areas and to reduce the preoperative adjustment time for the combined surgery, this paper proposes a preoperative planning algorithm based on the non-dominated sorting genetic algorithm II (NSGA-II) for robot-assisted minimally invasive Cholecystectomy combined with Appendectomy (RAMICA). The preoperative planning algorithm simultaneously optimizes the entry ports and configurations of the manipulators. The optimization objective functions of the preoperative planning algorithm consist of a novel global dexterity index (GDI) based on the coefficient of variation and the coordination index (CI) that reflects hand-eye coordination and instrument coordination. The constraints of the preoperative planning algorithm include the port placement constraint and the non-collision constraint. The preoperative planning scheme based on the optimization algorithm are verified by comparative simulations to provide the better dexterity and coordination of the manipulators. Finally, the contrast experiments are carried out to demonstrate the effectiveness and superiority of the preoperative planning scheme obtained by the optimization algorithm.
- Open Access
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 144136-144155
Development of a New Medical Robot System for Minimally Invasive Surgery
This paper presents the development of a new medical robot system comprising a spherical remote center motion (RCM) mechanism with modular design and two mechanical decoupling methods for Minimally Invasive Surgery (MIS). We achieved excellent comprehensive performance indices through a novel multi-objective optimization model comprising four optimization objective functions, three constrained conditions and two optimization variables. In order to enhance the manipulability, remove the coupling between motors, and reduce the control difficulty, two new decoupling mechanism means were proposed to remove coupling motion between the wrist and pincers, coupling motion between the translational joint of mobile platform and four interface disks of surgical instrument as a results of rear drive motor, respectively. The control system architecture is designed to include intuitive motion control, incremental motion control, and proportional motion control. Master-slave attitude registration and surgical instrument replacement strategies improve the master-slave control efficiency. We tested the spherical RCM mechanism performance indices and developed two mechanical decoupling methods and a master–slave control algorithm. Our experimental test results validated that fixing point accuracy, the coupling motions, the positioning and repeated positioning accuracy of the MIS robot, and master–slave control algorithm meet the requirements of MIS. Successful animal experiments confirmed effectiveness of the novel MIS robot system.
- 5 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 144136-144155
Open AccessDevelopment of a New Medical Robot System for Minimally Invasive Surgery
This paper presents the development of a new medical robot system comprising a spherical remote center motion (RCM) mechanism with modular design and two mechanical decoupling methods for Minimally Invasive Surgery (MIS). We achieved excellent comprehensive performance indices through a novel multi-objective optimization model comprising four optimization objective functions, three constrained conditions and two optimization variables. In order to enhance the manipulability, remove the coupling between motors, and reduce the control difficulty, two new decoupling mechanism means were proposed to remove coupling motion between the wrist and pincers, coupling motion between the translational joint of mobile platform and four interface disks of surgical instrument as a results of rear drive motor, respectively. The control system architecture is designed to include intuitive motion control, incremental motion control, and proportional motion control. Master-slave attitude registration and surgical instrument replacement strategies improve the master-slave control efficiency. We tested the spherical RCM mechanism performance indices and developed two mechanical decoupling methods and a master–slave control algorithm. Our experimental test results validated that fixing point accuracy, the coupling motions, the positioning and repeated positioning accuracy of the MIS robot, and master–slave control algorithm meet the requirements of MIS. Successful animal experiments confirmed effectiveness of the novel MIS robot system.
- 30 July 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (6) , e1942
Improved surgical instruments without coupled motion used in minimally invasive surgery
Background Unlike a manual surgical instrument, a surgical instrument used in robot‐assisted minimally invasive surgery (MIS) is configured with a wrist to improve flexibility in surgical operation. However, this configuration has a shortcoming that leads to coupled motion between the wrist and end‐effector. Methods Three methods are presented to eliminate the coupled motion between the wrist and end‐effector. The three methods are compared via the decoupled motion characteristic, and the third method is applied to design four surgical instruments. Several experiments are done to validate the effectiveness of these surgical instruments. Results These improved surgical instruments create decoupled motion. The results of experiments on the removal of gall bladder and kidney are excellent, which validates the effectiveness of decoupled surgical instruments. Conclusions Improved surgical instruments without coupled motion are developed and have a promising clinical application in MIS.
- 30 July 2018
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 14 (6) , e1942
Improved surgical instruments without coupled motion used in minimally invasive surgery
Background Unlike a manual surgical instrument, a surgical instrument used in robot‐assisted minimally invasive surgery (MIS) is configured with a wrist to improve flexibility in surgical operation. However, this configuration has a shortcoming that leads to coupled motion between the wrist and end‐effector. Methods Three methods are presented to eliminate the coupled motion between the wrist and end‐effector. The three methods are compared via the decoupled motion characteristic, and the third method is applied to design four surgical instruments. Several experiments are done to validate the effectiveness of these surgical instruments. Results These improved surgical instruments create decoupled motion. The results of experiments on the removal of gall bladder and kidney are excellent, which validates the effectiveness of decoupled surgical instruments. Conclusions Improved surgical instruments without coupled motion are developed and have a promising clinical application in MIS.