DCDaniel F. Craft

Daniel F. Craft

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniel F. Craft has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Three-Dimensionally Printed On-Skin Radiation Shields Using High-Density Filament

    by Daniel F. Craft, Jarrod Lentz, Mike Armstrong, Madeline Foster, Justin Gagneur, Daniel Harrington, Steven E. Schild, Mirek Fatyga


  • Material matters: Analysis of density uncertainty in 3D printing and its consequences for radiation oncology

    by Daniel F. Craft, Stephen F. Kry, Peter Balter, Mohammad Salehpour, Wendy Woodward, Rebecca M. Howell

    Purpose: Using 3D printing to fabricate patient‐specific devices such as tissue compensators, boluses, and phantoms is inexpensive and relatively simple. However, most 3D printing materials have not been well characterized, including their radiologic tissue equivalence. The purposes of this study were to (a) determine the variance in Hounsfield Units (HU) for printed objects, (b) determine if HU varies over time, and (c) calculate the clinical dose uncertainty caused by these material variations.Methods: For a sample of 10 printed blocks each of PLA, NinjaFlex, ABS, and Cheetah, the average HU and physical density were tracked at initial printing and over the course of 5 weeks, a typical timeframe for a standard course of radiotherapy. After initial printing, half the blocks were stored in open boxes, the other half in sealed bags with desiccant. Variances in HU and density over time were evaluated for the four materials. Various clinical photon and electron beams were used to evaluate potential errors in clinical depth dose as a function of assumptions made during treatment planning. The clinical depth error was defined as the distance between the correctly calculated 90% isodose line and the 90% isodose line calculated using clinically reasonable, but simplified, assumptions.Results: The average HU measurements of individual blocks of PLA, ABS, NinjaFlex, and Cheetah varied by as much as 121, 30, 178, and 30 HU, respectively. The HU variation over 5 weeks was much smaller for all materials. The magnitude of clinical depth errors depended strongly on the material, energy, and assumptions, but some were as large as 9.0 mm.Conclusions: If proper quality assurance steps are taken, 3D printed objects can be used accurately and effectively in radiation therapy. It is critically important, however, that the properties of any material being used in patient care be well understood and accounted for.


  • Open Access

    Preparation and fabrication of a full‐scale, sagittal‐sliced, 3D‐printed, patient‐specific radiotherapy phantom

    by Daniel F. Craft, Rebecca M. Howell

    Purpose: Patient‐specific 3D‐printed phantoms have many potential applications, both research and clinical. However, they have been limited in size and complexity because of the small size of most commercially available 3D printers as well as material warping concerns. We aimed to overcome these limitations by developing and testing an effective 3D printing workflow to fabricate a large patient‐specific radiotherapy phantom with minimal warping errors. In doing so, we produced a full‐scale phantom of a real postmastectomy patient.Methods: We converted a patient's clinical CT DICOM data into a 3D model and then sliced the model into eleven 2.5‐cm‐thick sagittal slices. The slices were printed with a readily available thermoplastic material representing all body tissues at 100% infill, but with air cavities left open. Each slice was printed on an inexpensive and commercially available 3D printer. Once the printing was completed, the slices were placed together for imaging and verification. The original patient CT scan and the assembled phantom CT scan were registered together to assess overall accuracy.Results: The materials for the completed phantom cost $524. The printed phantom agreed well with both its design and the actual patient. Individual slices differed from their designs by approximately 2%. Registered CT images of the assembled phantom and original patient showed excellent agreement.Conclusions: Three‐dimensional printing the patient‐specific phantom in sagittal slices allowed a large phantom to be fabricated with high accuracy. Our results demonstrate that our 3D printing workflow can be used to make large, accurate, patient‐specific phantoms at 100% infill with minimal material warping error.


  • WE-D-BRA-05: Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom

    by R Ger, Ea Burgett, Rr Price, Df Craft, Sf Kry, Rm Howell


  • Long-lived electron spins in a modulation doped (100) GaAs quantum well

    by J. S. Colton, D. Meyer, K. Clark, D. Craft, J. Cutler, T. Park, P. White

    We have measured T1 spin lifetimes of a 14 nm modulation-doped (100) GaAs quantum well using a time-resolved pump-probe Kerr rotation technique. The quantum well was selected by tuning the wavelength of the probe laser. T1 lifetimes in excess of 1 μs were measured at 1.5 K and 5.5 T, exceeding the typical T2* lifetimes that have been measured in GaAs and II-VI quantum wells by orders of magnitude. We observed effects from nuclear polarization, which were largely removable by simultaneous nuclear magnetic resonance, along with two distinct lifetimes under some conditions that likely result from probing two differently localized subsets of electrons.