Bingxi Yan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bingxi Yan has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Liang Guo
Department of Electrical and Computer Engineering, The Ohio State University, 2015 Neil Ave, 205 Dreese Labs, Columbus, Ohio, 43210, UNITED STATES
8 shared publications - Jie Shen
Department of Materials Science, Fudan University, Shanghai 200433, China
3 shared publications Sheng-Yun Luo
College of Science, Guizhou University for Nationalities, Guizhou 550025, PR China
3 shared publications- Yu Wu
Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210, USA
3 shared publications Chunping Ma
Department of Civil, Environmental and Geodetic Engineering The Ohio State University Columbus OH 43210 USA
2 shared publicationsDuo An
Department of Biological and Environmental Engineering Cornell University Ithaca NY USA
2 shared publications
Latest Publications
- Open Access
- 17 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1756
Actuators for Implantable Devices: A Broad View
The choice of actuators dictates how an implantable biomedical device moves. Specifically, the concept of implantable robots consists of the three pillars: actuators, sensors, and powering. Robotic devices that require active motion are driven by a biocompatible actuator. Depending on the actuating mechanism, different types of actuators vary remarkably in strain/stress output, frequency, power consumption, and durability. Most reviews to date focus on specific type of actuating mechanism (electric, photonic, electrothermal, etc.) for biomedical applications. With a rapidly expanding library of novel actuators, however, the granular boundaries between subcategories turns the selection of actuators a laborious task, which can be particularly time-consuming to those unfamiliar with actuation. To offer a broad view, this study (1) showcases the recent advances in various types of actuating technologies that can be potentially implemented in vivo, (2) outlines technical advantages and the limitations of each type, and (3) provides use-specific suggestions on actuator choice for applications such as drug delivery, cardiovascular, and endoscopy implants.
- 17 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1756
Open AccessActuators for Implantable Devices: A Broad View
The choice of actuators dictates how an implantable biomedical device moves. Specifically, the concept of implantable robots consists of the three pillars: actuators, sensors, and powering. Robotic devices that require active motion are driven by a biocompatible actuator. Depending on the actuating mechanism, different types of actuators vary remarkably in strain/stress output, frequency, power consumption, and durability. Most reviews to date focus on specific type of actuating mechanism (electric, photonic, electrothermal, etc.) for biomedical applications. With a rapidly expanding library of novel actuators, however, the granular boundaries between subcategories turns the selection of actuators a laborious task, which can be particularly time-consuming to those unfamiliar with actuation. To offer a broad view, this study (1) showcases the recent advances in various types of actuating technologies that can be potentially implemented in vivo, (2) outlines technical advantages and the limitations of each type, and (3) provides use-specific suggestions on actuator choice for applications such as drug delivery, cardiovascular, and endoscopy implants.
- Open Access
- 19 November 2019
- Published by Wiley in Advanced Engineering Materials
- Vol. 21 (11)
Geometrically Enabled Soft Electroactuators via Laser Cutting
- 19 November 2019
- Published by Wiley in Advanced Engineering Materials
- Vol. 21 (11)
Open AccessGeometrically Enabled Soft Electroactuators via Laser Cutting
- Open Access
- 1 October 2019
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 2 (5-6) , e10055
Battery‐free implantable insulin micropump operating at transcutaneously radio frequency‐transmittable power
Implantable insulin pumps that can be wirelessly powered may provide a pain‐free solution to continual treatment of Type‐1 diabetes. However, their design and development have long been prohibited by the lack of low‐voltage actuators operated at a wirelessly deliverable small power. Here we introduce a battery‐free insulin pump actuated by a soft and inherently biocompatible polymeric squeezer. At a low voltage below 1.5 V and a small power below 2 mW, which is deliverable using a miniature wireless harvester, our pump consistently delivers a volumetric output of 10 µl within 1 min at a flow rate of 0.21 µl/s. Moreover, comparative studies based on diabetic mice show well agreed blood glucose responses of pump‐ and syringe‐delivery solutions. These encouraging results pave the way for a lightweight, small‐dimension and battery‐free solution to overcome major disadvantages in current implantable insulin pumps.
- 1 October 2019
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 2 (5-6) , e10055
Open AccessBattery‐free implantable insulin micropump operating at transcutaneously radio frequency‐transmittable power
Implantable insulin pumps that can be wirelessly powered may provide a pain‐free solution to continual treatment of Type‐1 diabetes. However, their design and development have long been prohibited by the lack of low‐voltage actuators operated at a wirelessly deliverable small power. Here we introduce a battery‐free insulin pump actuated by a soft and inherently biocompatible polymeric squeezer. At a low voltage below 1.5 V and a small power below 2 mW, which is deliverable using a miniature wireless harvester, our pump consistently delivers a volumetric output of 10 µl within 1 min at a flow rate of 0.21 µl/s. Moreover, comparative studies based on diabetic mice show well agreed blood glucose responses of pump‐ and syringe‐delivery solutions. These encouraging results pave the way for a lightweight, small‐dimension and battery‐free solution to overcome major disadvantages in current implantable insulin pumps.
- 18 September 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 123 (40) , 8580-8589
Fast Electrochemical Netting of Composite Chains for Transferable Highly Conductive Polymeric Nanofilms
Broad applications of electropolymerized conducting polymers (CPs) often prefer thinner soft electrodes to comply with downscaling of the fabrication resolution. However, high conductivity of existing CP films vanishes as thickness decreases to the nanoscale (below 100 nm), with an unclear mechanism so far. In this study, based on an unprecedented family of polypyrrole (PPy) nano films that can be easily transferred in a fast and contamination-free manner, we’re enabled to synchronize initial development of electrical conductance along with chains arrangement starting from early electrochemical deposition. Our results evidence that the classical nodular polymeric aggregation fundamentally accounts for persistent loss of interchain connectivity and macroscopic conductivity at limited thickness. Surprisingly, this disadvantageous structure can be altered into a large conjugated network to restore conductivity robustly back to over 80 S cm-1 even below 100 nm, while the controllable formation, growth, and collapse of such networks radically vary conductivity over three orders of magnitude (0.8–129 S cm-1). These clues complete the first physical picture detailing conductivity buildup in a growing conjugated network, which opens up a route to fast synthesis and diverse applications of highly conductive CP nano films.
- 18 September 2019
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 123 (40) , 8580-8589
Fast Electrochemical Netting of Composite Chains for Transferable Highly Conductive Polymeric Nanofilms
Broad applications of electropolymerized conducting polymers (CPs) often prefer thinner soft electrodes to comply with downscaling of the fabrication resolution. However, high conductivity of existing CP films vanishes as thickness decreases to the nanoscale (below 100 nm), with an unclear mechanism so far. In this study, based on an unprecedented family of polypyrrole (PPy) nano films that can be easily transferred in a fast and contamination-free manner, we’re enabled to synchronize initial development of electrical conductance along with chains arrangement starting from early electrochemical deposition. Our results evidence that the classical nodular polymeric aggregation fundamentally accounts for persistent loss of interchain connectivity and macroscopic conductivity at limited thickness. Surprisingly, this disadvantageous structure can be altered into a large conjugated network to restore conductivity robustly back to over 80 S cm-1 even below 100 nm, while the controllable formation, growth, and collapse of such networks radically vary conductivity over three orders of magnitude (0.8–129 S cm-1). These clues complete the first physical picture detailing conductivity buildup in a growing conjugated network, which opens up a route to fast synthesis and diverse applications of highly conductive CP nano films.
- 23 July 2019
- Published by Wiley in Advanced Engineering Materials
- Vol. 21 (11) , 1900664
Geometrically Enabled Soft Electroactuators via Laser Cutting
Recent advances in soft electroactuators (EAs) have inspired diverse novel artificial muscles and dexterous robots. Despite a rapidly expanding library of electroactive materials, precise and repeatable structuring remains a challenge. Existing EAs often involve post‐synthesis hand‐assembling of supportive components such as hingers, linkages, adhesives, and coatings to fulfill demanding functions. Following a different enabling strategy, herein, a straightforward laser‐patterning approach to directly embed functional 2D structures into electroactive polypyrrole (PPy) films is presented, thereby transforming their typical bending actuation into various demanding action modes including squeezing, gripping, flapping, and lifting in an electrolyte solution analog to body fluids in vivo. Such geometrically enabled movements prove controllable and modulable and are dictated primarily by the embedded patterns rather than materials or specific fabrication approach. The integrity of our soft EAs not only avoids laborious assembling and device fatigues but also further enables systematic structural design and geometrical fine‐tuning of deformations through fast mechanical simulation. This design strategy suggests broad opportunities in pattern‐augmented capabilities for next‐generation EAs and soft robotics.
- 23 July 2019
- Published by Wiley in Advanced Engineering Materials
- Vol. 21 (11) , 1900664
Geometrically Enabled Soft Electroactuators via Laser Cutting
Recent advances in soft electroactuators (EAs) have inspired diverse novel artificial muscles and dexterous robots. Despite a rapidly expanding library of electroactive materials, precise and repeatable structuring remains a challenge. Existing EAs often involve post‐synthesis hand‐assembling of supportive components such as hingers, linkages, adhesives, and coatings to fulfill demanding functions. Following a different enabling strategy, herein, a straightforward laser‐patterning approach to directly embed functional 2D structures into electroactive polypyrrole (PPy) films is presented, thereby transforming their typical bending actuation into various demanding action modes including squeezing, gripping, flapping, and lifting in an electrolyte solution analog to body fluids in vivo. Such geometrically enabled movements prove controllable and modulable and are dictated primarily by the embedded patterns rather than materials or specific fabrication approach. The integrity of our soft EAs not only avoids laborious assembling and device fatigues but also further enables systematic structural design and geometrical fine‐tuning of deformations through fast mechanical simulation. This design strategy suggests broad opportunities in pattern‐augmented capabilities for next‐generation EAs and soft robotics.
- 28 April 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 293, 200-206
Intrinsically passivated polypyrrole/polyol-borate soft electroactuators
- 28 April 2019
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 293, 200-206
Intrinsically passivated polypyrrole/polyol-borate soft electroactuators
- Open Access
Recent Advances on Polypyrrole Electroactuators
Featuring controllable electrochemomechanical deformation and excellent biocompatibility, polypyrrole electroactuators used as artificial muscles play a vital role in the design of biomimetic robots and biomedical devices. In the past decade, tremendous efforts have been devoted to their optimization on electroactivity, electrochemical stability, and actuation speed, thereby gradually filling the gaps between desired capabilities and practical performances. This review summarizes recent advances on polypyrrole electroactuators, with particular emphases on novel counterions and conformation-reinforcing skeletons. Progress and challenges are comparatively demonstrated and critically analyzed, to enlighten future developments of advanced electroactuators based on polypyrrole and other conducting polymers.
Open AccessRecent Advances on Polypyrrole Electroactuators
Featuring controllable electrochemomechanical deformation and excellent biocompatibility, polypyrrole electroactuators used as artificial muscles play a vital role in the design of biomimetic robots and biomedical devices. In the past decade, tremendous efforts have been devoted to their optimization on electroactivity, electrochemical stability, and actuation speed, thereby gradually filling the gaps between desired capabilities and practical performances. This review summarizes recent advances on polypyrrole electroactuators, with particular emphases on novel counterions and conformation-reinforcing skeletons. Progress and challenges are comparatively demonstrated and critically analyzed, to enlighten future developments of advanced electroactuators based on polypyrrole and other conducting polymers.
- 17 August 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (34) , 29113-29119
Flexible Photocatalytic Composite Film of ZnO-Microrods/Polypyrrole
Zinc oxide (ZnO)-based photoanodes with sunlight photocatalytic activity are widely used in dye-sensitized solar cells. Presently, most of such electrodes are inflexible due to the rigidness of ZnO and substrate, thus hindering their application in flexible electronics. Here, we report a flexible composite film of ZnO microrod arrays and polypyrrole (PPy) featuring significant flexibility, durability, and photocatalytic capability under visible light. In this composite film, the upper section of the ZnO microrods is coated with an approximately 400 nm thick PPy shell, and the lower section of the ZnO microrods is tightly embedded into an underlying PPy base layer, creating an integrated heterogeneous structure. The upper PPy coating shell serves as a photosensitizer for the ZnO-based photocatalysis, while the lower PPy base layer facilitates electron transport to the substrate and mechanically reinforces the ZnO microrod arrays. Under visible light, this facile structure achieves much higher photocatalytic efficiency in comparison to pure ZnO microrod arrays or PPy film, degrading methylene blue at a rate of 0.22%/min. This photocatalytic composite film may find promising applications in flexible solar cells to power stretchable and wearable electronics.
- 17 August 2017
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 9 (34) , 29113-29119
Flexible Photocatalytic Composite Film of ZnO-Microrods/Polypyrrole
Zinc oxide (ZnO)-based photoanodes with sunlight photocatalytic activity are widely used in dye-sensitized solar cells. Presently, most of such electrodes are inflexible due to the rigidness of ZnO and substrate, thus hindering their application in flexible electronics. Here, we report a flexible composite film of ZnO microrod arrays and polypyrrole (PPy) featuring significant flexibility, durability, and photocatalytic capability under visible light. In this composite film, the upper section of the ZnO microrods is coated with an approximately 400 nm thick PPy shell, and the lower section of the ZnO microrods is tightly embedded into an underlying PPy base layer, creating an integrated heterogeneous structure. The upper PPy coating shell serves as a photosensitizer for the ZnO-based photocatalysis, while the lower PPy base layer facilitates electron transport to the substrate and mechanically reinforces the ZnO microrod arrays. Under visible light, this facile structure achieves much higher photocatalytic efficiency in comparison to pure ZnO microrod arrays or PPy film, degrading methylene blue at a rate of 0.22%/min. This photocatalytic composite film may find promising applications in flexible solar cells to power stretchable and wearable electronics.
- 1 April 2017
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 32 (2) , 223-228
Enhanced photoelectric property of Mo-C codoped TiO2 films deposited by RF magnetron cosputtering
- 1 April 2017
- Published by Springer Nature in Journal of Wuhan University of Technology-Mater. Sci. Ed.
- Vol. 32 (2) , 223-228
Enhanced photoelectric property of Mo-C codoped TiO2 films deposited by RF magnetron cosputtering