Carl Esben Poulsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carl Esben Poulsen has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Anders Wolff
Department of Biotechnology and Biomedicine, Technical University of Denmark (DTU-Bioengineering), Lyngby, Denmark
5 shared publications - Mikkel Fougt Hansen
Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark
3 shared publications - Kasper Kistrup
Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech, Building 345 East, DK-2800 Kongens Lyngby, Denmark.
2 shared publications - Rafael Taboryski
Technical University of Denmark
2 shared publications Andrew J. Demello
‡Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland
1 shared publication- Dang Duong Bang
Laboratory of Applied Micro and Nanotechnology (LAMINATE), Division of Microbiology and Production, National Food Institute, Technical University of Denmark, Kemitorvet, Building 204, DK 2800 Lyngby, Denmark
1 shared publication
Latest Publications
- 20 April 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (6) , 067001
Laser ablated micropillar energy directors for ultrasonic welding of microfluidic systems
We present a new type of energy director (ED) for ultrasonic welding of microfluidic systems. These micropillar EDs are based on the replication of cone like protrusion structures introduced using a pico-second laser and may therefore be added to any mould surface accessible to a pico-second laser beam. The technology is demonstrated on an injection moulded microfluidic device featuring high-aspect ratio ( h × w = 2000 μ m × 550 μ m) and free-standing channel walls, where bonding is achieved with no detectable channel deformation. The bonding strength is similar to conventional EDs and the fabricated system can withstand pressures of over 9.5 bar.
- 20 April 2016
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 26 (6) , 067001
Laser ablated micropillar energy directors for ultrasonic welding of microfluidic systems
We present a new type of energy director (ED) for ultrasonic welding of microfluidic systems. These micropillar EDs are based on the replication of cone like protrusion structures introduced using a pico-second laser and may therefore be added to any mould surface accessible to a pico-second laser beam. The technology is demonstrated on an injection moulded microfluidic device featuring high-aspect ratio ( h × w = 2000 μ m × 550 μ m) and free-standing channel walls, where bonding is achieved with no detectable channel deformation. The bonding strength is similar to conventional EDs and the fabricated system can withstand pressures of over 9.5 bar.
- 18 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (12) , 6265-6270
A Microfluidic Platform for the Rapid Determination of Distribution Coefficients by Gravity-Assisted Droplet-Based Liquid–Liquid Extraction
The determination of pharmacokinetic properties of drugs, such as the distribution coefficient (D) is a crucial measurement in pharmaceutical research. Surprisingly, the conventional (gold standard) technique used for D measurements, the shake-flask method, is antiquated and unsuitable for the testing of valuable and scarce drug candidates. Herein, we present a simple microfluidic platform for the determination of distribution coefficients using droplet-based liquid–liquid extraction. For simplicity, this platform makes use of gravity to enable phase separation for analysis and is 48 times faster and uses 99% less reagents than performing an equivalent measurement using the shake-flask method. Furthermore, the D measurements achieved in our platform are in good agreement with literature values measured using traditional shake-flask techniques. Since D is affected by volume ratios, we use the apparent acid dissociation constant, pK′, as a proxy for intersystem comparison. Our platform determines a pK′ value of 7.24 ± 0.15, compared to 7.25 ± 0.58 for the shake-flask method in our hands and 7.21 for the shake-flask method in the literature. Devices are fabricated using injection molding, the batchwise fabrication time is <2 min per device (at a cost of $1 U.S. per device), and the interdevice reproducibility is high.
- 18 May 2015
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (12) , 6265-6270
A Microfluidic Platform for the Rapid Determination of Distribution Coefficients by Gravity-Assisted Droplet-Based Liquid–Liquid Extraction
The determination of pharmacokinetic properties of drugs, such as the distribution coefficient (D) is a crucial measurement in pharmaceutical research. Surprisingly, the conventional (gold standard) technique used for D measurements, the shake-flask method, is antiquated and unsuitable for the testing of valuable and scarce drug candidates. Herein, we present a simple microfluidic platform for the determination of distribution coefficients using droplet-based liquid–liquid extraction. For simplicity, this platform makes use of gravity to enable phase separation for analysis and is 48 times faster and uses 99% less reagents than performing an equivalent measurement using the shake-flask method. Furthermore, the D measurements achieved in our platform are in good agreement with literature values measured using traditional shake-flask techniques. Since D is affected by volume ratios, we use the apparent acid dissociation constant, pK′, as a proxy for intersystem comparison. Our platform determines a pK′ value of 7.24 ± 0.15, compared to 7.25 ± 0.58 for the shake-flask method in our hands and 7.21 for the shake-flask method in the literature. Devices are fabricated using injection molding, the batchwise fabrication time is <2 min per device (at a cost of $1 U.S. per device), and the interdevice reproducibility is high.
- 9 April 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (11) , 2445-2451
Miniaturization of a micro-optics array for highly sensitive and parallel detection on an injection moulded lab-on-a-chip
We developed a lab-on-a-chip system integrating miniaturized micro-optic SAF arrays within microfluidic chambers for high sensitivity and multiplexed detection of fluorescent molecules.
- 9 April 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (11) , 2445-2451
Miniaturization of a micro-optics array for highly sensitive and parallel detection on an injection moulded lab-on-a-chip
We developed a lab-on-a-chip system integrating miniaturized micro-optic SAF arrays within microfluidic chambers for high sensitivity and multiplexed detection of fluorescent molecules.
- 10 March 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (9) , 1998-2001
Ultrasonic welding for fast bonding of self-aligned structures in lab-on-a-chip systems
Ultrasonic welding is a rapid, promising bonding method for the bonding of polymer chips; yet its use is still limited. We present two lab-on-a-chip applications where ultrasonic welding can be preferably applied: (1) self-aligned gapless bonding of a two-part chip with a tolerance of 50 μm; (2) bonding of a large area shallow chamber (1.8 cm2 × 150 μm). Using injection moulding combined with ultrasonic welding we achieved a total production and bonding time of 60 s per chip, and a batch of chips could be produced within a day going from design to finished chips. We believe that the technical solutions offered here can significantly help bridge the gap between academia and industry, where the differences in production methods and materials pose a challenge when transferring technology.
- 10 March 2015
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 15 (9) , 1998-2001
Ultrasonic welding for fast bonding of self-aligned structures in lab-on-a-chip systems
Ultrasonic welding is a rapid, promising bonding method for the bonding of polymer chips; yet its use is still limited. We present two lab-on-a-chip applications where ultrasonic welding can be preferably applied: (1) self-aligned gapless bonding of a two-part chip with a tolerance of 50 μm; (2) bonding of a large area shallow chamber (1.8 cm2 × 150 μm). Using injection moulding combined with ultrasonic welding we achieved a total production and bonding time of 60 s per chip, and a batch of chips could be produced within a day going from design to finished chips. We believe that the technical solutions offered here can significantly help bridge the gap between academia and industry, where the differences in production methods and materials pose a challenge when transferring technology.
- 12 November 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (12)
Fabrication and modelling of injection moulded all-polymer capillary microvalves for passive microfluidic control
- 12 November 2014
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 24 (12)
Fabrication and modelling of injection moulded all-polymer capillary microvalves for passive microfluidic control