KSKarri Saarnio

Karri Saarnio

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Karri Saarnio has a total of 131 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Composition and sources of atmospheric trace elements at three urban sites in Helsinki, Finland

    by M. Aurela, K. Saarnio, J.V. Niemi, E. Turunen, K. Teinilä, A. Kousa, H.E. Manninen, J. Hoivala, M. Vestenius, T. Rönkkö, et al.

  • Uudistetun ilmanlaatudirektiivin 2881/2024 vaatimukset – vaikutusarvio kansallista täytäntöönpanoa varten

    by Katriina Kyllönen, Elli Suhonen, Kaisa Korpi, Karri Saarnio, Ari Karppinen, Anu-Maija Sundström, Heidi Hellén

    Tiivistelmä Uudistettu ilmanlaatudirektiivi (EU) 2024/2881 astui voimaan 11.12.2024. Uudistetun direktiivin uudet vaatimukset astuvat voimaan kahden vuoden siirtymäajan puitteissa. Uudet vaatimukset aiheuttavat muutoksia ilmanlaadun vastuisiin, seurantaan, raportointiin ja tarvittaviin toimenpiteisiin. Näitä ovat mm. tiukentuneet raja-arvot ja arviointikynnykset, uusien huolta-aiheuttavien ilmansaasteiden seurantavelvoitteet sekä uusi supermittausasemakonsepti, ilmansuojelun etenemissuunnitelmat sekä kansalaisten tiedottamiseen liittyvät velvollisuudet kuten ilmanlaatuindeksi. Tässä vaikutusten arvioinnissa on tarkoitus selvittää ne keskeiset tekijät, jotka aiheuttavat muutoksia Suomessa ilmanlaadun vastuisiin, seurantaan, raportointiin, tiedottamiseen ja muihin toimenpiteisiin hankesuunnitelman mukaisesti. Tuloksena on uudistetun direktiivin kansallinen vaikutusarviointi, joka sisältää myös kustannusarviot uusista vastuista ja tehtävistä. Lisäksi vaikutusarviointi toimii kansallisena suunnitelmana, miten muutokset toteutetaan sisältäen ehdotukset vastuutahoiksi sekä käytännön toteutussuunnitelman. Arvioinnissa on myös esitetty joitain lisäselvitystarpeita.

  • Ulkoilman NO-, SO2- ja O3-mittausten kansallinen vertailumittaus sekä ilmanlaatumittausten auditointi 2023– 2024 (KAUDI-2023)

    by Katriina Kyllönen, Karri Saarnio, Kaisa Lusa, Enna Turunen, Heidi Hellén

    Viides kaasumaisten yhdisteiden vertailumittauskampanja sekä mittausasemien kenttä- ja laatujärjestelmäauditointi suoritettiin Suomen ilmanlaadun mittausverkoille vuosien 2023–2024 aikana. Tässä raportissa esitetään vertailumittausten sekä kenttä- ja laatujärjestelmäauditoinnin tulokset sekä johtopäätökset. Vertailumittauksessa kaasukomponentit olivat typpimonoksidi (NO), rikkidioksidi (SO2) ja otsoni (O3). Vertailupitoisuudet eri komponenteille koostuivat kahdesta eri pitoisuudesta, joista toinen edusti korkeahkoa pitoisuutta ja toinen alhaista pitoisuutta. Lisäksi kullekin komponentille suoritettiin nollatason mittaus. Mittaustulosten raportointi vertailuun osallistuneilta tahoilta edellytti korjatut tulokset jokaisesta vertailumittauksesta sekä arvion mittaustulosten epävarmuudesta. Vertailumittauksiin osallistui 17 mittausverkkoa 32:sta ilmanlaadun seurantaa suorittavasta mittausverkosta. Osalla verkoista mittausten suorittamisesta vastaa sama toimija, joten tällaisissa tapauksissa valittiin vain yksi mittausverkko edustamaan kyseistä toimijaa. Näissä vertailumittauksia suoritettiin yhteensä 62 mittausta 22:lla eri mittausasemalla. Raportoiduista NO-tuloksista 29 tulosta 30:stä oli hyväksyttäviä. SO2:n osalta 30 tulosta 30:stä oli hyväksyttäviä. O3:n osalta 14 tulosta 14:sta oli hyväksyttäviä. NO:n, SO2:n ja O3:n osalta yhteensä 98,4 % tuloksista oli hyväksyttäviä. Jokainen osallistuneista mittausverkoista oli laatinut mittausepävarmuusarvion vertailumittaustuloksilleen. Pitoisuusvertailujen ohessa suoritetussa kenttä- ja laatujärjestelmäauditoinnissa pyrittiin selvittämään mittausverkon laatujärjestelmän laajuus ja toimivuus. Pääpaino oli erityisesti mittausmenetelmää kuvaavien standardien vaatimusten toteutuminen kentällä tehtävissä laadunvarmennustoimissa. Auditoinnissa tarkasteltiin kaasumaisten komponenttien mittausten lisäksi ulkoilman hiukkasmittauksia. Auditointiin osallistui 20 mittausverkkoa 32:sta ilmanlaadun seurantaa suorittavasta mittausverkosta. Laatujärjestelmä- ja kenttäauditointien tulokset olivat ylipäätään hyviä. Mittausverkot ovat laatineet menetelmäohjeita mittausaseman sijoittamisesta, mittausmenetelmistä, laadunvarmennustoimista, tulosten käsittelystä ja raportoinnista. Laatujärjestelmiä on kehitetty viime auditoinnin jälkeen. Mittausverkkojen ylläpitämistä laatujärjestelmistä 14 oli kattavia, neljä oli kohtuullisia ja kahdella mittausverkolla laatujärjestelmä oli pääasiallisesti dokumentoitu, mutta se ei ollut aktiivikäytössä. Kaikissa verkoissa oli toimivat tietojen keruu- ja käsittelyohjelmistot. Ilmanlaatumittausten tulokset oli jäljitetty kansalliseen vertailulaboratorioon joko suoraan mittausverkkojen ylläpitämillä tai konsulttien suorittamilla kalibroinneilla, joskin kalibrointivälit eivät aina täyttäneet EN-menetelmästandardeja. Kaasu- ja PM-mittausten laadunvarmennustoimet olivat pääasiallisesti EN-menetelmästandardien mukaisia, ja tarpeen mukaan mittausverkoille annettiin parannusehdotuksia. Toimissa näkyi merkittävää kehitystä edelliseen kierrokseen nähden.

  • Verification of suitability of automated PM10 and PM2.5 measuring systems in Finland 2021 (Ongoing-2021)

    by Karri Saarnio, Mika Vestenius, Jani Immonen, Katriina Kyllönen

    The Air Quality Directive (2008/50/EC) defines the reference methods (RM) for determining the mass concentration of particulate matter (PM) in air. A Member State may use other methods provided that they can demonstrate a consistent relationship with the reference method. In Finland, a demonstration of equivalence (DoE) for automated continuous monitoring systems (AMS) for PM10 and PM2.5 was conducted in Kuopio in 2014–2015 (Waldén et al., 2017). The AMS instruments used in DoE and this study are the ones that are widely used in local air quality networks to control compliance with the limit values for particulate matter concentrations. The present study verifies the suitability of calibration factors obtained in the Kuopio DoE for use elsewhere in Finland. The 2021 verification campaign was carried out at the Tikkurila station in Vantaa, operated by Helsinki Region Environmental Services (HSY), within the project National quality program for particulate matter measurements: Ongoing verification of suitability of automated measuring systems (Ongoing 2021). Seven AMS representing different instrument types and measurement techniques were compared with the gravimetric reference method according to EN 12341:2014. The verification followed a modified approach based on EN 16450:2017, enabling broader inclusion of instruments over a seven-month campaign. The results showed that TEOM 1405, TEOM 1405-D, and Palas Fidas 200 S performed within the expanded uncertainty limit (≤25%) for PM10 measurements, while GRIMM EDM180 failed with the Kuopio DoE calibration but it would pass when a new theoretical equation derived from the current study would be applied. For PM2.5, TEOM 1405 and Palas Fidas 200 S fulfilled the uncertainty criteria, whereas TEOM 1405-D and GRIMM EDM180 did not, although both would pass using revised theoretical calibration factors. The correction equations of TEOM 1405-D are not official, and they are not recommended for wider use. Two Palas AQ Guard monitors were also tested for the first time in Finland, showing promising results for both PM10 and PM2.5, with uncertainties below 25%, but lacking EN 16450:2017 type-testing certification. Overall, the verification confirmed that the calibration factors from the Kuopio DoE remain valid for TEOM 1405 and the provisional calibration factors from Ongoing 2019–2020 (Saarnio et al., 2021) for Palas Fidas 200 series instruments. GRIMM EDM180 requires additional verification tests or an updated calibration equation, TEOM 1405-D needs a revised correction equation for PM2.5, and Palas AQ Guard instruments show potential for good performance in PM monitoring. The results highlight the importance of continued national verification to ensure consistent and reliable particulate matter measurements throughout Finland.

  • Ilmanlaadun mittausohje 2025

    by Katariina Kyllönen, Kaisa Lusa, Karri Saarnio, Elli Suhonen, Kaisa Korpi, Heidi Héllen

    Suomen ilmanlaadun seurantaa säätelevät suurelta osin EU:n ilmanlaatua koskevat direktiivit. Ilman epäpuhtauksien pitoisuuksia säädellään sitovien ilmanlaatunormien eli mm. raja-arvojen ja tavoitearvojen avulla. Myös kansalliset ohjearvot ovat edelleen voimassa ja niitä käytetään suunnittelun tukena, mutta niiden merkitys on vähenemässä. Raja-arvoja valvoviksi asemiksi kutsutaan niitä ilmanlaadun mittausasemia, jotka täyttävät ilmanlaatudirektiivien kriteerit ja joiden pitoisuustiedot toimitetaan EU:lle. Raja-arvopitoisuuksia valvovien mittausasemien lisäksi ilmanlaatua seurataan mittausverkoissa laajalti erilaisista paikallisista tarpeista, mikä on ollut aikanaan lähtökohta useimpien ilmanlaatumittausten aloittamiselle. Ilmanlaatua seurataan ensisijaisesti hyvän ilmanlaadun turvaamiseksi paikallisille asukkaille ja ympäristölle. Ilmanlaatua mitataan lisäksi muun muassa yksittäisten päästölähteiden vaikutusten arvioimiseksi, asukkaille tiedottamisen vuoksi, ympäristölupaehtojen täyttämiseksi sekä jatkuvan ilmanlaadun seurannan tarvetta arvioitaessa. Tämä ohje koskee ilmanlaadun mittaamista osana ilmanlaadun seurantaa. Ohjeessa käsitellään ilmanlaatulainsäädäntöä, mittaustarpeen arviointia, mittausten suunnittelua, tekemistä ja laadunvarmennustoimenpiteitä, laatujärjestelmän sisältöä, raportointia sekä tiedottamista. Ohjeen tarkoituksena on kehittää mittausten laatua, luotettavuutta, edustavuutta ja vertailtavuutta sekä luoda edellytyksiä ilmanlaadun mittaustulosten monipuoliselle hyödyntämiselle. Ilmatieteen laitos päivitti ilmanlaadun mittausohjetta edellisen kerran vuonna 2017, ja nyt mittausohjetta on edelleen laajennettu ja päivitetty ajan tasalle.

  • Attestation of conformity of particulate matter measurements (HIVATO) 2019–2020

    by Karri Saarnio, Mika Vestenius, Katriina Kyllönen

    The National Reference Laboratory for Air Quality (NRL) ensures the high quality of air quality measurements in Finland by organising audits and intercomparison campaigns. In this project, the conformity of the particulate matter measurements was evaluated with a particular focus on the measurement used for calculating the average exposure index (AEI) of Finland. The representativity and applicability of the AEI measurements made at the Kallio station in Helsinki were evaluated. It was noticed that the results of the Kallio measurement represent well the average fine particle (PM2.5) concentrations and the yearly based trend of fine particles in Finland. In addition, the yearly average concentrations of fine particles have been smaller than the AEI limit value of 8.5 µg/m3, at all individual urban background stations in Finland since year 2015. The measurement results made with the PM monitor used for AEI measurement, i.e. TEOM 1405 analyser at the Kallio station, were compared to the results from the reference method that follows the standard SFS-EN 12341:2014. It was noticed that the uncertainty requirement of 25% was reached and therefore the quality of the measurement is sufficient to use it for the calculation of AEI. However, the fine particle concentrations were generally very low and therefore the requirements given in the standard SFS-EN 16450:2017 for an intercomparison against the reference method were not perfectly fulfilled. This report presents also results from intercomparison measurements made for automated continuous measurement systems (AMS). At the Virolahti station and at the Mäkelänkatu station in Helsinki, PM10 and PM2.5 measurements were compared. In Kuopio and in Lahti, intercomparison measurements were made for PM2.5 only. Based on the results from these intercomparisons, the calibration coefficients both for PM10 and PM2.5 were defined for the first time in Finland for a FIDAS 200 analyser that is a new PM monitor in the Finnish market. It was concluded that FIDAS 200 analysers can be used for the PM measurements in Finland when the calibration coefficients are applied for the data; however, one must note that the presented calibration coefficients do not fulfil the requirements given for the demonstration of equivalence (DoE). Nevertheless, these coefficients are recommended to be used until the official coefficients will be delivered from the next DoE campaign. Two AMS (SHARP 5030 and TEOM 1405) were compared to the reference method for the measurements of PM10 and PM2,5 in Virolahti and in Helsinki, respectively. It was revealed that the calibration coefficients based on the DoE in Kuopio (2014–2015) do not always fit ideally at different locations and seasons due to differences in the environmental characteristics of the measurement sites. Therefore, NRL recommends that DoE should be organised every five years and in between the DoE’s so called ongoing-intercomparison measurements should be carried out continuously. In the ongoing-intercomparison, suitability of the calibration coefficients from DoE will be verified in different locations with varying environmental characteristics. The ongoing-intercomparison campaigns should take place at one site from a half a year to one year and after that, the campaign should continue at a different location similarly. This would ensure that the influence of seasonal differences to the suitability of coefficients will be verified at each measurement site.

  • Verification of the validity of air quality measurements related to the Directive 2004/107/EC in 2019-2020 (DIRME2019)

    by Finnish Meteorological Institute, Katriina Kyllönen, Karri Saarnio, Ulla Makkonen, Heidi Hellén

    This project summarizes the results from 2000–2020and evaluates the trueness andthequality control (QC) procedures of the ongoing polycyclic aromatic hydrocarbon (PAH)and trace element measurements in Finlandrelating to Air Quality (AQ) Directive 2004/107/EC. The evaluation was focused on benzo(a)pyrene and other PAH compounds as well as arsenic, cadmium and nickel in PM10and deposition. Additionally, it included lead and other metals in PM10and deposition, gaseous mercury and mercury deposition, andbriefly other specificAQ measurements such as volatile organic compounds (VOC)and PM2.5chemical composition. This project was conducted by the National Reference Laboratory on air quality and thiswas the first time these measurements were assessed. A major part of the project was field and laboratory audits of the ongoing PAH and metal measurements. Other measurements were briefly evaluated through interviews and available literature. In addition, the national AQ database, the expertise of local measurement networks and related publications were utilised. In total, all theseven measurement networks performing PAH and metal measurements in 2019–2020took part in the audits. Eleven stations were audited while these measurements are performed at 22 AQ stations in Finland. For the large networks, one station was chosen to represent the performance of the network. The audits included also six laboratories performing the analysis of the collected samples. The audits revealed the compliance of the measurements with the AQ Decree 113/2017, Directive 2004/107/EC and Standards of the European Committee for Standardization(CEN). In addition, general information of the measurements, instruments and quality control procedures were gained. The results of the laboratory audits were confidential,but this report includes general findings, and the measurement networks were informed on the audit results with the permission of the participating laboratories. As a conclusion, the measurementmethodsusedwere mainly reference methods. Currently, all sampling methods were reference methods; however, before 2018 three networks used other methods that may have underestimated concentrations. Regarding these measurements, it should be noted the results are notcomparable with the reference method. Laboratory methods were reference methods excluding two cases, where the first was considered an acceptable equivalent method. For the other, a change to a reference method was strongly recommended and this realized in 2020. For some new measurements, the ongoing QC procedures were not yet fully established, and advice were given. Some networks used consultant for calibration and maintenance, and thus theywere not fully aware of the QC procedures. EN Standards were mostly followed. Main concerns were related to the checks of flow and calculation of measurement uncertainty, and suggestions for improvement were given. When the measurement networks implement the recommendations given inthe audits, it can be concluded that the EN Standards are adequately followed in the networks. In the ongoing sampling, clear factors risking the trueness of the result were not found. This applies also for the laboratory analyses in 2020. One network had concentrations above the target value, and theindicative measurementsshould be updated to fixed measurements.

  • Chemical composition and size of particles in emissions of a coal-fired power plant with flue gas desulfurization

    by Karri Saarnio, Anna Frey, Jarkko V. Niemi, Hilkka Timonen, Topi Rönkkö, Panu Karjalainen, Mika Vestenius, Kimmo Teinilä, Liisa Pirjola, Ville Niemelä, et al.


  • Correction to Optical and Chemical Characterization of Aerosols Emitted from Coal, Heavy and Light Fuel Oil and Small-Scale Wood Combustion

    by Anna K. Frey, Karri Saarnio, Heikki Lamberg, Fanni Mylläri, Panu Karjalainen, Kimmo Teinilä, Samara Carbone, Jarkko Tissari, Ville Niemelä, Anna Häyrinen, et al.

  • Open Access

    Wintertime Aerosol Chemistry in Sub-Arctic Urban Air

    by Samara Carbone, Minna Aurela, Karri Saarnio, Sanna Saarikoski, Hilkka Timonen, Anna Frey, Donna Sueper, Ingrid M. Ulbrich, Jose L. Jimenez, Markku Kulmala, et al.

    Measurements of submicron particulate matter (PM) were performed at an urban background station, in Helsinki, Finland during wintertime to investigate the chemical characteristics and sources of PM1. The PM1 was dominated by sulfate and organics. The source apportionment indicated that organic aerosol (OA) was a mixture from local sources (biomass burning (BBOA), traffic, coffee roaster (CROA)), secondary compounds formed in local wintertime conditions (nitrogen containing OA (NOA), semivolatile oxygenated OA (SV-OOA), and regional and long-range transported compounds (low volatile oxygenated OA, LV-OOA). BBOA was dominated by the fragments C2H4O2 + and C3H4O2 + (m/z 60.021 and 73.029) from levoglucosan, or other similar sugar components, comprising on average 32% of the BBOA mass concentration. The ratio between fragments C2H4O2 +/C3H4O2 + was significantly lower for CROA (=1.1) when compared to BBOA (=2.1), indicating that they consisted of different sugar compounds. In addition, a component containing substantial amount of nitrogen compounds (NOA) was observed in a sub-arctic region for the first time. The NOA contribution to OA ranged from 1% to 29% and elevated concentrations were observed when ambient relative humidity was high and the visibility low. Low solar radiation and temperature in wintertime were observed to influence the oxidation of compounds. A change in aerosol composition, with an increase of LV-OOA and decrease in BBOA, SV-OOA and NOA was noticed during the transition from wintertime to springtime. Size distribution measurements with high-time resolution enabled chemical characterization of externally mixed aerosol from different sources. Aged regional long-range transported aerosols were dominant at around 0.5 μm (vacuum aerodynamic diameter), whereas traffic and CROA emissions dominated at around 120 nm. Copyright 2014 American Association for Aerosol Research