Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Minoru Shinohara has a total of 186 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhancing Visuomotor Reaction during Dark Transition via Model-Optimized Transcutaneous Vagus Nerve Stimulation

    by Shintaro Nakatani, Wuyuqing Yang, Joshua N Posen, Jun Ueda, Minoru Shinohara

    Sudden reductions in ambient illuminance temporarily impair visuomotor performance due to the inherent latency of dark adaptation, posing significant risks in operational environments such as tunnel entry. To mitigate this degradation, we propose a model-based neuromodulation framework using transcutaneous vagus nerve stimulation (tVNS), which is known to accelerate and augment pupil dilation and potentially enhance sensorimotor processing by activating the locus coeruleus-norepinephrine (LC-NE) system. First, we characterized the temporal dynamics of the tVNS-induced pupillary response and developed a predictive model using a long short-term memory (LSTM) network in standard lighting. The model demonstrated efficacy in reproducing nonlinear physiological characteristics even under sudden dark exposure. Second, we derived optimized stimulation sequences using a genetic algorithm to maximize pupil dilation during immediate adaptation to darkness. Pupillary evaluations during bright-to-dark transitions revealed that the optimized tVNS additively increased pupil diameter. The improvement in visuomotor choice-reaction performance was highly correlated with the amount of tVNS-induced increase in pupil diameter during dark transition across healthy young adults. These findings suggest that the model-optimized tVNS approach may effectively mitigate the degradation of visuomotor performance during dark transitions via LC-NE activation as well as subsequent sensorimotor enhancement. Furthermore, the experimental results demonstrate the potential of the transient pupil response to tVNS to serve as a robust physiological indicator for predicting behavioral improvement.

  • Bioimpedance meets biomechanics: Wearable electrical impedance myography encodes fascicle and activation dynamics

    by Christopher J. Nichols, Nicholas Harris, H. Trask Crane, Autumn Routt, Milki D. Haile, Quentin Goossens, Minoru Shinohara, Gregory S. Sawicki, Kristen L. Jakubowski, Omer T. Inan

    Modern assistive robotic control demands parallel advancements in wearable, noninvasive sensing. Electrical impedance myography (EIM)—a noninvasive, wearable technology for dynamically measuring tissue electrical impedance properties—is a promising but poorly established solution for quantifying muscle force and fatigue, given that prior approaches have relied on black-box algorithms when attempting to relate EIM to muscle physiology or have extrapolated relationships between EIM and muscle force from singular, isolated movements. Here, we elucidate direct relationships between EIM and muscle kinematics and kinetics during functional movement using biomechanical principles and traditional measures of joint torque, muscle architecture, and activation. Dual-frequency EIM measurements of the medial gastrocnemius of 10 participants were collected and compared against dynamometer, B-mode ultrasound, and electromyography measurements. Participants performed multiple categories of dynamic movements spanning constrained isometric, self-selected isometric, concentric, and eccentric contractions at multiple force levels, joint angles, and angular velocities. EIM correlated to joint torque only for specific conditions, whereas EIM correlated with muscle length change dynamics across all movements. Mixed-effects modeling and sequential feature analysis showed fascicle length and muscle activation as primary drivers of EIM variance. Last, dual-frequency EIM combined with principal components analysis reliably captured changes in fascicle length and activation during walking. These findings validate EIM as a robust, real-time biomechanical tool for sensing muscle kinematics and neuromuscular activity during functional movement, expanding its use in assistive robotic control and injury prevention.

  • Association between correlated effective neural drive and electromechanical fluctuations during co-contraction: Insights from MU discharges and interference EMG

    by Moeka Samoto, Minoru Shinohara, Kohei Watanabe, Yasuhide Yoshitake

    This study investigated the correlation between the strength of correlated effective neural drive (END) to the antagonistic muscles and the fluctuations in neural/electrical and mechanical output around the joint during steady co-contraction, and whether the correlated END strength estimated from conventional surface EMG is correlated with that determined from motor unit (MU) discharges. Fourteen young male participants performed isometric steady co-contractions with their medial gastrocnemius and tibialis anterior muscles at 10% of maximal EMG while sitting. Correlated END strength was quantified as the maximum value of the cross-correlation function between the conventional surface EMG signals and between MU discharges decomposed from high-density surface EMG of each muscle. Correlated END strength quantified from each signal was both negatively correlated with the fluctuations in net force (MU-based: r = −0.78; EMG-based: r = −0.63, P < 0.025) but positively correlated with the fluctuations in the corresponding neural/electrical signal (MU-based: r = 0.54; EMG-based: r = 0.73, P < 0.05). Additionally, the fluctuations in MU discharge frequency was negatively correlated with the fluctuations in net ankle extension-flexion force recorded as the mechanical output (r = −0.57, P < 0.05). Furthermore, correlated END strength was highly correlated between the MU-based and EMG-estimated measures (r = 0.83, P < 0.05). These results suggest that individuals with a greater correlated END to the antagonistic muscles exhibit greater neural/electrical fluctuations yet steadier mechanical output at the joint level during co-contraction, and the strength of correlated END can be observed in conventional surface EMG in such conditions.

  • Open Access

    Closed-loop Neuromotor Training System Pairing Transcutaneous Vagus Nerve Stimulation with Video-based Real-time Movement Classification

    by Minoru Shinohara, Arya Mohan, Nathaniel Green, Joshua N. Posen, Milka Trajkova, Woon-Hong Yeo, Hyeokhyen Kwon

    As an emerging neurostimulation for improving motor rehabilitation, applying vagus nerve stimulation (VNS) after successful movement during training facilitates motor recovery in animals with neuromotor impairment. To translate this procedure to human rehabilitation in a non-invasive, objective, and automated manner, real-time classification of movement quality on a trial-by-trial basis in a minimally constrained state is required. In this work, we developed an integrated closed-loop system using video-based real-time movement classification that can automatically trigger transcutaneous VNS (tVNS) wirelessly as soon as successful movement is detected. We also created a film-like conformable tVNS electrode to be attached over the outer ear. For movement training, we focused on the use case of dance therapy (backward walking), which is widely used for people with Parkinson’s disease and older adults. Our markerless video analysis model could detect steps with 0.91 precision and 0.72 recall and classify successful backward steps with a 0.93 F1 score. The classification triggers tVNS through Bluetooth Low Energy communications with a trigger relay device we created. The integrated system enabled real-time automated classification and stimulation, triggering tVNS with 71.3% of the successful movements and taking 2.24 s from video capture to tVNS. We consider our work to be an important step toward patient-driven rehabilitation at home showcasing non-invasive, low-cost, and automated closed-loop neurostimulation technologies.


  • Open Access

    Synergistic Torso-Muscle-Controlled Detached Robotic Hand: A Novel Approach for Post-Stroke Hand Rehabilitation

    by Joshua N. Posen, Joshua Lee, Frank L. Hammond, Stephen N. Housley, Andrew J. Butler, Minoru Shinohara

    This study aimed to develop a novel rehabilitative approach for post-stroke hand movement using a simple detached robotic hand and synergistic torso muscle activities for reaching and to perform a pilot test on its functionality and feasibility. In reference to a mental practice that does not activate hand muscles, enhanced cognitive engagement would be achieved without hand activation using the externally present, visible, and audible robotic hand by activating the non-hand muscles associated with hand function. A simple and low-cost robotic hand was developed and placed distal to the hidden resting hand as if it were a functional extended hand. The opening and closing motions of the detached robotic hand were controlled by electromyogram of the anterior and posterior torso muscles associated with reaching and retrieving while providing visual and auditory feedback. The functionality of the developed system was confirmed on the repeatability of the range of duration, excursion, and response time with low variability within an acceptable range. An able-bodied adult and five mildly impaired stroke survivors embodied the detached robotic hand by successfully controlling it with or without concurrent testing of their biological finger. In the concurrent finger tests, increased reactive force and hand muscle activity were observed in most participants. These observations confirmed that the developed approach that controls a detached robotic hand with reaching-associated torso muscles is functional and applicable to stroke survivors with and without involving the biological human hand. The robotic hand system detached from the user and controlled by the voluntary effort of their reaching-associated torso muscles has enabled future studies to examine the efficacy of synergistic muscle-robot interaction as a potential rehabilitation tool.

  • Open Access

    ‘StreamPoseML’ An End-to-End Open-Source Web Application and Python Toolkit for Real-Time Video Pose Classification and Machine Learning

    by Milka Trajkova, Nathaniel Green, Minoru Shinohara

    With the ubiquity of video content in various sectors, from surveillance to entertainment to education, the demand for effective video analytics has never been greater-video data are being produced and consumed at an unprecedented rate, leading to an increased need for end-to-end research tools to integrate, manage, and utilize this massive influx of information. Classifying videos using machine learning often involves a series of data processing steps-data collection, annotation, pre-processing, model training, and deployment. These tasks require different tools and skill sets, making the process fragmented, time-consuming, and complex. Currently, many open-source machine learning pipelines require users to manually integrate different tools and libraries, which can be time-consuming and error-prone. There is a significant need for tools that can automatically develop an end-to-end machine learning pipeline, especially for human motion classification. A unified platform that can handle multiple stages in the machine learning pipeline will greatly streamline the workflow, saving time, reducing complexity, and lowering the barrier to entry for practitioners without extensive machine learning expertise. Our proposed web application and Python toolkit, "StreamPoseML" is an open-source, end-to-end toolkit for creating real-time, video-based classification experiments based on labeled data and body keypoint/pose estimation of human movements. It provides the capability of dataset generation, pre-processing, model building and training, as well as deployment in a real-time environment. Users will be able to monitor and adjust their models on the fly in the backend and test their models using a front-end UI. To illustrate its use, we provide an examples of ongoing research on designing a real-time trial-to-trial movement classification for older adults undergoing Adapted Tango dance therapy.


  • Manual Interstructural Release Procedure Can Alter Muscle Shear Modulus

    by Tomoko Yamashita, Yasuhide Yoshitake, Hironori Watanabe, Sohei Washino, Kazuyoshi Gamada, Minoru Shinohara

    Purpose: Interstructural release (ISR) procedure to skeletal muscles is believed to attenuate adhesion between neighboring muscles and alleviate subjective symptoms, including perceived stiffness and associated pain. However, objective evidence about the effect of ISR on the mechanical properties of the muscles is limited. The purpose of this study was to test the acute effect of ISR on the shear modulus of adjacent muscles. It was hypothesized that ISR applied to the border between synergistic muscles would acutely reduce the resting shear modulus of the involved muscle. Methods: To assess the effect of ISR, the shear modulus of the resting peroneus longus (PL) and soleus (SOL) muscles was measured at various ankle joint positions (inversion/eversion) before and after interventions in nine nonsymptomatic male individuals (age: 21.9 ± 1.4 yr, height: 170 ± 6.6 cm, body mass: 64.3 ± 4.0 kg). Potential muscle activity during the measurement was assessed by recording surface electromyogram from these muscles. The interventions were ISR to the lower leg between the deep fascia of the PL and SOL and sham (massage). Results: As the ankle joint position was passively varied toward inversion, the shear modulus increased substantially in PL and decreased moderately in SOL. Shear modulus of the proximal PL in the most inverted position increased acutely after ISR (by 11.4 ± 5.8%, P <0.001), but not after the sham, without any change in the amplitude of electromyogram. Conclusions: These results provide objective evidence that the ISR procedure can acutely alter shear modulus, at least in a specific site in a resting muscle.

  • Top Cited Papers
    Open Access

    Intelligent upper-limb exoskeleton integrated with soft bioelectronics and deep learning for intention-driven augmentation

    by Jinwoo Lee, Kangkyu Kwon, Ira Soltis, Jared Matthews, Yoon Jae Lee, Hojoong Kim, Lissette Romero, Nathan Zavanelli, Youngjin Kwon, Shinjae Kwon, et al.

    The age and stroke-associated decline in musculoskeletal strength degrades the ability to perform daily human tasks using the upper extremities. Here, we introduce an intelligent upper-limb exoskeleton system that utilizes deep learning to predict human intention for strength augmentation. The embedded soft wearable sensors provide sensory feedback by collecting real-time muscle activities, which are simultaneously computed to determine the user’s intended movement. Cloud-based deep learning predicts four upper-limb joint motions with an average accuracy of 96.2% at a 500–550 ms response rate, suggesting that the exoskeleton operates just by human intention. In addition, an array of soft pneumatics assists the intended movements by providing 897 newtons of force while generating a displacement of 87 mm at maximum. The intent-driven exoskeleton can reduce human muscle activities by 3.7 times on average compared to the unassisted exoskeleton.


  • Transcutaneous vagus nerve stimulation at nonspecific timings during training can compromise motor adaptation in healthy humans

    by Mitchell Adrien St. Pierre, Minoru Shinohara

    Adding vagus nerve stimulation via implanted electrodes during motor training can facilitate motor recovery in disabled animals and humans. No study examined the effect of transcutaneous vagus nerve stimulation (tVNS) during training on neuromotor adaptation in healthy humans. We have found that adding tVNS at nonspecific timings during motor skill training can compromise motor adaptation but not transfer in healthy humans.


  • Open Access

    Design and Preliminary Evaluation of a Tongue-Operated Exoskeleton System for Upper Limb Rehabilitation

    by Zhenxuan Zhang, Boris I. Prilutsky, Andrew J. Butler, Minoru Shinohara, Maysam Ghovanloo

    Stroke is a devastating condition that may cause upper limb paralysis. Robotic rehabilitation with self-initiated and assisted movements is a promising technology that could help restore upper limb function. Previous studies have established that the tongue motion can be used to communicate human intent and control a rehabilitation robot/assistive device. The goal of this study was to evaluate a tongue-operated exoskeleton system (TDS-KA), which we have developed for upper limb rehabilitation. We adopted a tongue-operated assistive technology, called the tongue drive system (TDS), and interfaced it with the exoskeleton KINARM. We also developed arm reaching and tracking tasks, controlled by different tongue operation modes, for training and evaluation of arm motor function. Arm reaching and tracking tasks were tested in 10 healthy participants (seven males and three females, 23–60 years) and two female stroke survivors with upper extremity impairment (32 and 58 years). All healthy and two stroke participants successfully performed the tasks. One stroke subject demonstrated a clinically significant improvement in Fugl-Meyer upper extremity score after practicing the tasks in six 3-h sessions. We conclude that the TDS-KA system can accurately translate tongue commands to exoskeleton arm movements, quantify the function of the arm, and perform rehabilitation training.