Rossella Brancaccio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rossella Brancaccio has a total of 434 co-authors. Here are the top co-authors by number of shared publications:
- Maria Pia Morigi
Department of Physics and Astronomy, UNIBO, 40127 Bologna, Italy
42 shared publications - Matteo Bettuzzi
Department of Physics, Alma Mater Studiorum University of Bologna, 40126 Bologna, Italy
38 shared publications F. Casali
28 shared publications- Fauzia Albertin
National Research Council, Institute of Chemical Science and Technologies “G. Natta
12 shared publications A. Pasini
11 shared publicationsS. Cornacchia
11 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (10) , 6009904
DATG 2.0 Integrated Liquid Crystal Sensing Platform and Tissue-Equivalent Phantom for High-Resolution Thermovascular Imaging
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (10) , 6009904
Open AccessDATG 2.0 Integrated Liquid Crystal Sensing Platform and Tissue-Equivalent Phantom for High-Resolution Thermovascular Imaging
- Open Access
- 22 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0358226
Virtuality VS Reality: Testing a virtual approach for the exploratory analysis of Bronze Age urns from Northern Italy
Cremation is among the most destructive funerary practices. Over the past 30 years, radiographic imaging has increasingly been used to non-destructively extract information from cremation burials. Advances in scanners and imaging software have enhanced the quality of data retrievable through this method. However, scanning cremated remains, particularly when urned, presents challenges due to their fragility, size, material density overlaps, and the high cost of imaging equipment. These factors often result in low-quality images where distinguishing different materials becomes difficult and time-consuming. This exploratory research aims to provide and assess qualitative and quantitative information from tomographic images on burials’ taphonomy, biological profiles (sex and age at death), Minimum Number of Individuals (MNI) and thermal alterations to the bones and to evaluate a relatively simple segmentation strategy to analyse the spatial distribution of the remains in the vessels. For this purpose, 10 non-micro-excavated urns from the Middle-Late Bronze Age necropolis of Vicofertile (Parma, Italy) were scanned using Computerised Tomography (CT), subsequently micro-excavated, and the remains analysed to compare the information obtained from the two approaches. When extracted, data about the age classes, burial taphonomy, and heat-induced changes to the bones (e.g., fractures) were confirmed by the physical analysis, while the MNI, hypothesised to be 10 from the scans, was increased by one. Sex estimation was not possible from the scans. The vertical and horizontal distribution of the remains was estimated for cranial, long, spongy bones, upper, lower limbs, and trunk elements, with the vertical cranial distribution being the most accurately predicted category. Overall, the physical analysis proved essential to refine the results of virtual analysis and deal with the drawbacks of low-quality images. Despite the limitations discussed here, this research presents the largest systematic comparison of tomographic imaging and physical analysis of urned cremations to date, highlighting both the potential and the current limitations of CT-based investigation.
- 22 September 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (9) , e0358226
Open AccessVirtuality VS Reality: Testing a virtual approach for the exploratory analysis of Bronze Age urns from Northern Italy
Cremation is among the most destructive funerary practices. Over the past 30 years, radiographic imaging has increasingly been used to non-destructively extract information from cremation burials. Advances in scanners and imaging software have enhanced the quality of data retrievable through this method. However, scanning cremated remains, particularly when urned, presents challenges due to their fragility, size, material density overlaps, and the high cost of imaging equipment. These factors often result in low-quality images where distinguishing different materials becomes difficult and time-consuming. This exploratory research aims to provide and assess qualitative and quantitative information from tomographic images on burials’ taphonomy, biological profiles (sex and age at death), Minimum Number of Individuals (MNI) and thermal alterations to the bones and to evaluate a relatively simple segmentation strategy to analyse the spatial distribution of the remains in the vessels. For this purpose, 10 non-micro-excavated urns from the Middle-Late Bronze Age necropolis of Vicofertile (Parma, Italy) were scanned using Computerised Tomography (CT), subsequently micro-excavated, and the remains analysed to compare the information obtained from the two approaches. When extracted, data about the age classes, burial taphonomy, and heat-induced changes to the bones (e.g., fractures) were confirmed by the physical analysis, while the MNI, hypothesised to be 10 from the scans, was increased by one. Sex estimation was not possible from the scans. The vertical and horizontal distribution of the remains was estimated for cranial, long, spongy bones, upper, lower limbs, and trunk elements, with the vertical cranial distribution being the most accurately predicted category. Overall, the physical analysis proved essential to refine the results of virtual analysis and deal with the drawbacks of low-quality images. Despite the limitations discussed here, this research presents the largest systematic comparison of tomographic imaging and physical analysis of urned cremations to date, highlighting both the potential and the current limitations of CT-based investigation.
- Open Access
- 7 August 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 127
Jugular venous pulse analysis: software and statistical assessment in healthy patients using a non-invasive plethysmography system
- 7 August 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 127
Open AccessJugular venous pulse analysis: software and statistical assessment in healthy patients using a non-invasive plethysmography system
- Open Access
- 26 February 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta (0 ν β β ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0 ν β β decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0 ν β β decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.
- 26 February 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Open AccessThe detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta (0 ν β β ) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here, we report the detection of marine microseismic vibrations using mK-scale calorimeters. This study employs a multi-device analysis correlating data from CUORE, the leading experiment in the search for 0 ν β β decay with mK-scale calorimeters, and the Copernicus Earth Observation program, revealing the seasonal impact of Mediterranean Sea activity on CUORE’s energy thresholds, resolution, and sensitivity over four years. The detection of marine microseisms underscores the need to address faint environmental noise in ultra-sensitive experiments. Understanding how such noise couples to the detector and developing mitigation strategies is essential for next-generation experiments. We demonstrate one such strategy: a noise decorrelation algorithm implemented in CUORE using auxiliary sensors, which reduces vibrational noise and improves detector performance. Enhancing sensitivity to 0 ν β β decay and to rare events with low-energy signatures requires identifying unresolved noise sources, advancing noise reduction methods, and improving vibration suppression systems, all of which inform the design of next-generation rare event experiments.
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 216-220
Preliminary Evaluation of Piezoelectric Thin Film Sensors for Arterial and Venous Pulse Detection Using an Epidermal Neck Patch
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 216-220
Open AccessPreliminary Evaluation of Piezoelectric Thin Film Sensors for Arterial and Venous Pulse Detection Using an Epidermal Neck Patch
- Open Access
- 30 July 2024
- Published by PAGEPress Publications in Veins and Lymphatics
- Vol. 13
Extraction of the Jugular Venous Pulse and carotid profile using a cervical contact plethysmography system
The Jugular Venous Pulse (JVP) is considered a reliable parameter for the assessment of Central Venous Pressure (CVP). Here, the functionality of a cervical contact plethysmography system designed for non-invasive and operator-independent acquisition of the JVP signal, is shown. To validate the signal, it was recorded in supine and sitting positions, together with the reference Electrocardiography (ECG), on 26 healthy subjects. In the supine acquired signal, the characteristic JVP waves (a, c, v) and the negative deflections (x, y) are well recognizable. In the sitting recorded signal, the systolic peak b and the d incisura of the Common Carotid Artery (CCA) waveform are recognized. For each signal, we calculated the Fraction of the Cardiac Cycle (ccf) represented by the time intervals between the JVP peaks and the ECG peaks, in the form: ΔtaP, ΔtcR, ΔtxP, ΔtvT, Δtyv, Δtvx, and Δtxa. The same was done for the CCA waveform, in the form: ΔtbS, ΔtbT, Δtdb, ΔtdS, and ΔtdT. This system could mitigate risks and costs associated with central venous catheterization and its potential extends to applications in telemedicine, sports medicine, and space medicine.
- 30 July 2024
- Published by PAGEPress Publications in Veins and Lymphatics
- Vol. 13
Open AccessExtraction of the Jugular Venous Pulse and carotid profile using a cervical contact plethysmography system
The Jugular Venous Pulse (JVP) is considered a reliable parameter for the assessment of Central Venous Pressure (CVP). Here, the functionality of a cervical contact plethysmography system designed for non-invasive and operator-independent acquisition of the JVP signal, is shown. To validate the signal, it was recorded in supine and sitting positions, together with the reference Electrocardiography (ECG), on 26 healthy subjects. In the supine acquired signal, the characteristic JVP waves (a, c, v) and the negative deflections (x, y) are well recognizable. In the sitting recorded signal, the systolic peak b and the d incisura of the Common Carotid Artery (CCA) waveform are recognized. For each signal, we calculated the Fraction of the Cardiac Cycle (ccf) represented by the time intervals between the JVP peaks and the ECG peaks, in the form: ΔtaP, ΔtcR, ΔtxP, ΔtvT, Δtyv, Δtvx, and Δtxa. The same was done for the CCA waveform, in the form: ΔtbS, ΔtbT, Δtdb, ΔtdS, and ΔtdT. This system could mitigate risks and costs associated with central venous catheterization and its potential extends to applications in telemedicine, sports medicine, and space medicine.
- Open Access
- 19 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 873
Hygroscopicity and Morphology of Bio-Based Boards—The Influence of the Formulation
The internal structures and the hygroscopicity of bio-based boards consisting of giant reed (Arundo donax L.) and hazelnut shells as bio-aggregates, and a sodium silicate solution as the adhesive, were investigated. The aim was to evaluate the influence of each material (the bio-aggregates and adhesive) and their distributions in the boards on the final performance. By carrying out X-ray computed tomography, the internal structures and the porosities of the boards were determined, allowing important considerations of their hygroscopicity. The voids’ percentages were between 26% and 36% of the total volume of the composites. Both the materials and the composites demonstrated high hygroscopicity. In particular, the mixtures of the bio-aggregates and the sodium silicate allowed reaching a moisture buffering value of 7.44 g/(m2%RH) for the A. donax-based composite, 3.86 g/(m2%RH) for the hazelnut-shell-based composite, and 4.65 g/(m2%RH) for the mixture-based composite. Besides the identification of the contributions of the materials, a detailed discussion of the assessed properties was carried out to use these bio-based boards in vernacular historic construction. The results show how the aggregate type and the adhesive content affected the final behavior, demonstrating the importance of a conscious material choice. Furthermore, helpful information for the future development of these types of bio-based boards and their possible optimization was provided.
- 19 January 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (2) , 873
Open AccessHygroscopicity and Morphology of Bio-Based Boards—The Influence of the Formulation
The internal structures and the hygroscopicity of bio-based boards consisting of giant reed (Arundo donax L.) and hazelnut shells as bio-aggregates, and a sodium silicate solution as the adhesive, were investigated. The aim was to evaluate the influence of each material (the bio-aggregates and adhesive) and their distributions in the boards on the final performance. By carrying out X-ray computed tomography, the internal structures and the porosities of the boards were determined, allowing important considerations of their hygroscopicity. The voids’ percentages were between 26% and 36% of the total volume of the composites. Both the materials and the composites demonstrated high hygroscopicity. In particular, the mixtures of the bio-aggregates and the sodium silicate allowed reaching a moisture buffering value of 7.44 g/(m2%RH) for the A. donax-based composite, 3.86 g/(m2%RH) for the hazelnut-shell-based composite, and 4.65 g/(m2%RH) for the mixture-based composite. Besides the identification of the contributions of the materials, a detailed discussion of the assessed properties was carried out to use these bio-based boards in vernacular historic construction. The results show how the aggregate type and the adhesive content affected the final behavior, demonstrating the importance of a conscious material choice. Furthermore, helpful information for the future development of these types of bio-based boards and their possible optimization was provided.
- Open Access
- 10 January 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 66, 436-443
X-ray computed microtomography: A non-invasive and time-efficient method for identifying and screening Roman copper-based coins
- 10 January 2024
- Published by Elsevier in Journal of Cultural Heritage
- Vol. 66, 436-443
Open AccessX-ray computed microtomography: A non-invasive and time-efficient method for identifying and screening Roman copper-based coins
- Open Access
- 20 October 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (10) , 230
A Geometric Feature-Based Algorithm for the Virtual Reading of Closed Historical Manuscripts
X-ray Computed Tomography (CT), a commonly used technique in a wide variety of research fields, nowadays represents a unique and powerful procedure to discover, reveal and preserve a fundamental part of our patrimony: ancient handwritten documents. For modern and well-preserved ones, traditional document scanning systems are suitable for their correct digitization, and, consequently, for their preservation; however, the digitization of ancient, fragile and damaged manuscripts is still a formidable challenge for conservators. The X-ray tomographic approach has already proven its effectiveness in data acquisition, but the algorithmic steps from tomographic images to real page-by-page extraction and reading are still a difficult undertaking. In this work, we propose a new procedure for the segmentation of single pages from the 3D tomographic data of closed historical manuscripts, based on geometric features and flood fill methods. The achieved results prove the capability of the methodology in segmenting the different pages recorded starting from the whole CT acquired volume.
- 20 October 2023
- Published by MDPI AG in Journal of Imaging
- Vol. 9 (10) , 230
Open AccessA Geometric Feature-Based Algorithm for the Virtual Reading of Closed Historical Manuscripts
X-ray Computed Tomography (CT), a commonly used technique in a wide variety of research fields, nowadays represents a unique and powerful procedure to discover, reveal and preserve a fundamental part of our patrimony: ancient handwritten documents. For modern and well-preserved ones, traditional document scanning systems are suitable for their correct digitization, and, consequently, for their preservation; however, the digitization of ancient, fragile and damaged manuscripts is still a formidable challenge for conservators. The X-ray tomographic approach has already proven its effectiveness in data acquisition, but the algorithmic steps from tomographic images to real page-by-page extraction and reading are still a difficult undertaking. In this work, we propose a new procedure for the segmentation of single pages from the 3D tomographic data of closed historical manuscripts, based on geometric features and flood fill methods. The achieved results prove the capability of the methodology in segmenting the different pages recorded starting from the whole CT acquired volume.