Ian M. McAninch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ian M. McAninch has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
Giuseppe R. Palmese
Department of Chemical & Biological Engineering Drexel University 3141 Chestnut Street Philadelphia Pennsylvania 19104
4 shared publicationsJoseph L. Lenhart
US Army Research Laboratory, RDRL‐WMM‐G, Aberdeen Proving Ground Maryland 21005
4 shared publications- John J. La Scala
Combat Capabilities Development Command Army Research Laboratory, FCDD-RLW-MD, Aberdeen, MD 57401, USA
3 shared publications John J. La Scala
Army Research Laboratory, Aberdeen Proving Ground Weapons and Materials Research Directorate Maryland 21005
2 shared publicationsAdam D. Richardson
1 shared publication- Alice M. Savage
DEVCOM Army Research Laboratory, Aberdeen Proving Ground, MD 21005, USA
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Soft Matter
Mechanisms governing interlayer bonding in highly-filled thermally cured acrylate inks for direct ink writing
When 3D printing a particle filled thermosetting ink, particle migration and oxygen inhibition significantly influence both the printed microstructure and interlayer adhesion strength.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in Soft Matter
Open AccessMechanisms governing interlayer bonding in highly-filled thermally cured acrylate inks for direct ink writing
When 3D printing a particle filled thermosetting ink, particle migration and oxygen inhibition significantly influence both the printed microstructure and interlayer adhesion strength.
- 10 September 2016
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 134 (1)
Thin film initiation of cracks for fracture toughness measurements in epoxy resins
The first step in accurately measuring the fracture toughness of a polymeric material is to generate a sharp crack in the sample. Often this is accomplished by tapping a razor blade into the sample, allowing a natural crack to grow; however, it can be difficult to control the crack propagation. Alternate methods for initial crack generation are investigated, including scoring the sample with a razor blade and inserting thin films or foils into the samples during cure. Fluoropolymer films and aluminum and stainless steel foils of various thicknesses are examined in a number of epoxy‐amine resins with a range of toughness and glass transition values. None of the alternative methods replicate the results of starting with a natural crack. Furthermore, it is difficult to form satisfactory test samples using fluoropolymer films. For relative toughness comparisons, either the scoring method or thin, ≤25.4 μm, foils can be used to initiate cracks with similar results. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2016, 133, 44364.
- 10 September 2016
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 134 (1)
Thin film initiation of cracks for fracture toughness measurements in epoxy resins
The first step in accurately measuring the fracture toughness of a polymeric material is to generate a sharp crack in the sample. Often this is accomplished by tapping a razor blade into the sample, allowing a natural crack to grow; however, it can be difficult to control the crack propagation. Alternate methods for initial crack generation are investigated, including scoring the sample with a razor blade and inserting thin films or foils into the samples during cure. Fluoropolymer films and aluminum and stainless steel foils of various thicknesses are examined in a number of epoxy‐amine resins with a range of toughness and glass transition values. None of the alternative methods replicate the results of starting with a natural crack. Furthermore, it is difficult to form satisfactory test samples using fluoropolymer films. For relative toughness comparisons, either the scoring method or thin, ≤25.4 μm, foils can be used to initiate cracks with similar results. © 2016 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2016, 133, 44364.
- 10 September 2015
- Published by Wiley in Polymer Engineering & Science
- Vol. 55 (12) , 2761-2774
DMA testing of epoxy resins: The importance of dimensions
Dynamic mechanical analysis is commonly used to characterize thermoset polymers at temperatures ranging from well below to well above their glass transition temperatures. Many sample fixtures are available; however, the best clamp and best sample dimensions for a given material are not often readily apparent. Five different epoxy amine networks with glass transitions spanning over 100°C were characterized on three‐point bending, dual cantilever, and single cantilever clamps with both constant thickness and constant span‐to‐thickness. Glassy modulus values were accurately measured on all clamps provided span‐to‐thickness ratios >10 were maintained. Thermal expansion and decreasing sample stiffness with increasing temperature greatly affect measurements in the rubbery region resulting in single cantilever clamps being best suited to measure rubbery data. POLYM. ENG. SCI., 55:2761–2774, 2015. © 2015 Society of Plastics Engineers
- 10 September 2015
- Published by Wiley in Polymer Engineering & Science
- Vol. 55 (12) , 2761-2774
DMA testing of epoxy resins: The importance of dimensions
Dynamic mechanical analysis is commonly used to characterize thermoset polymers at temperatures ranging from well below to well above their glass transition temperatures. Many sample fixtures are available; however, the best clamp and best sample dimensions for a given material are not often readily apparent. Five different epoxy amine networks with glass transitions spanning over 100°C were characterized on three‐point bending, dual cantilever, and single cantilever clamps with both constant thickness and constant span‐to‐thickness. Glassy modulus values were accurately measured on all clamps provided span‐to‐thickness ratios >10 were maintained. Thermal expansion and decreasing sample stiffness with increasing temperature greatly affect measurements in the rubbery region resulting in single cantilever clamps being best suited to measure rubbery data. POLYM. ENG. SCI., 55:2761–2774, 2015. © 2015 Society of Plastics Engineers
- 10 October 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 132 (8)
Epoxy‐amine networks with varying epoxy polydispersity
Solid, high molecular weight DGEBA‐based epoxies were blended with high purity liquid DGEBA to create several resins with equivalent epoxy equivalent weights, but with polydispersity indices (PDIs) ranging from 3 to over 10. The resins were cured with a stoichiometric amount of polyetheramine and compared to a nonblended epoxy with PDI of 1.8. Modulus, glass transition temperatures, and molecular weight between cross‐links were measured using dynamic mechanical analysis. Coefficients of thermal expansion (CTE) were measured and used to extend room temperature density measurements as a function of temperature. Fracture properties were also measured. Overall, the increased polydispersity has almost negligible effect, with the main difference occurring in the slope of the glassy CTE, with more polydisperse epoxies having a slower increase in CTE. In comparison to previous work where bimodal amines were blended with DGEBA, we conclude that epoxy resins are far more sensitive to distributions in the flexible portion, rather than the more rigid one. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41503.
- 10 October 2014
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 132 (8)
Epoxy‐amine networks with varying epoxy polydispersity
Solid, high molecular weight DGEBA‐based epoxies were blended with high purity liquid DGEBA to create several resins with equivalent epoxy equivalent weights, but with polydispersity indices (PDIs) ranging from 3 to over 10. The resins were cured with a stoichiometric amount of polyetheramine and compared to a nonblended epoxy with PDI of 1.8. Modulus, glass transition temperatures, and molecular weight between cross‐links were measured using dynamic mechanical analysis. Coefficients of thermal expansion (CTE) were measured and used to extend room temperature density measurements as a function of temperature. Fracture properties were also measured. Overall, the increased polydispersity has almost negligible effect, with the main difference occurring in the slope of the glassy CTE, with more polydisperse epoxies having a slower increase in CTE. In comparison to previous work where bimodal amines were blended with DGEBA, we conclude that epoxy resins are far more sensitive to distributions in the flexible portion, rather than the more rigid one. © 2014 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015, 132, 41503.
- 3 May 2013
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 130 (3) , 1621-1631
Characterization of epoxies cured with bimodal blends of polyetheramines
DGEBA was cured with bimodal blends of polyetheramines as well as with single molecular weight amines while maintaining stoichiometry. Glass transition temperatures (Tgs) and moduli were measured using dynamic mechanical analysis (DMA). Fracture properties were measured using the compact tension geometry and testing was performed at both ambient and non‐ambient temperatures, investigating toughness changes as a function of temperature. For constant amine average molecular weights, the addition of high molecular weight amines caused increased glassy moduli at a constant T − Tg and decreased densities while broadening the glass transition without changing the fracture toughness. The fracture behavior, specifically the slip‐stick to brittle transition, was affected by the broadened transitions. Tg, breadth of Tg, and total damping were found to be proportional to the volume fraction of amine in the system. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 1621–1631, 2013
- 3 May 2013
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 130 (3) , 1621-1631
Characterization of epoxies cured with bimodal blends of polyetheramines
DGEBA was cured with bimodal blends of polyetheramines as well as with single molecular weight amines while maintaining stoichiometry. Glass transition temperatures (Tgs) and moduli were measured using dynamic mechanical analysis (DMA). Fracture properties were measured using the compact tension geometry and testing was performed at both ambient and non‐ambient temperatures, investigating toughness changes as a function of temperature. For constant amine average molecular weights, the addition of high molecular weight amines caused increased glassy moduli at a constant T − Tg and decreased densities while broadening the glass transition without changing the fracture toughness. The fracture behavior, specifically the slip‐stick to brittle transition, was affected by the broadened transitions. Tg, breadth of Tg, and total damping were found to be proportional to the volume fraction of amine in the system. © 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 1621–1631, 2013
- Open Access
- 1 March 2011
- Published by Defense Technical Information Center (DTIC)
Materials Characterization of High-Temperature Epoxy Resins: SC-79 and SC-15/SC-79 Blend
The relatively low glass transition temperature (Tg) of the Army's SC-15 epoxy resin system necessitates study into suitable alternative resins capable of better low- and high-temperature performance. This work investigates two of those alternative resins, SC-79 and CCMFCS2, a blend of SC-15 and SC-79, both manufactured by Applied Poleramic Inc. (Benicia, CA). The viscosities and gel times of these resins are similar to SC-15's, thus substitution of the SC-15 with SC-79 or CCMFCS2 would cause no processing issues. Several different curing cycles were tested for each resin in an effort to find the best process for U.S. Army applications. Three slow cure cycles showed no meaningful advantages over faster, elevated temperature cures. Under all tested cure conditions, both SC-79 and CCMFCS2 are able to achieve higher Tg's and similar or greater flexural properties than SC-15; however, SC-15's fracture and impact properties were superior.
- 1 March 2011
- Published by Defense Technical Information Center (DTIC)
Open AccessMaterials Characterization of High-Temperature Epoxy Resins: SC-79 and SC-15/SC-79 Blend
The relatively low glass transition temperature (Tg) of the Army's SC-15 epoxy resin system necessitates study into suitable alternative resins capable of better low- and high-temperature performance. This work investigates two of those alternative resins, SC-79 and CCMFCS2, a blend of SC-15 and SC-79, both manufactured by Applied Poleramic Inc. (Benicia, CA). The viscosities and gel times of these resins are similar to SC-15's, thus substitution of the SC-15 with SC-79 or CCMFCS2 would cause no processing issues. Several different curing cycles were tested for each resin in an effort to find the best process for U.S. Army applications. Three slow cure cycles showed no meaningful advantages over faster, elevated temperature cures. Under all tested cure conditions, both SC-79 and CCMFCS2 are able to achieve higher Tg's and similar or greater flexural properties than SC-15; however, SC-15's fracture and impact properties were superior.
- 1 November 2008
- Published by Elsevier in Composites Science and Technology
- Vol. 68 (14) , 2994-3001
Properties and performance of fire resistant eco-composites using polyhedral oligomeric silsesquioxane (POSS) fire retardants
- 1 November 2008
- Published by Elsevier in Composites Science and Technology
- Vol. 68 (14) , 2994-3001
Properties and performance of fire resistant eco-composites using polyhedral oligomeric silsesquioxane (POSS) fire retardants
- 12 August 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 98 (3) , 1325-1338
Impure carbon nanotubes as reinforcements for acrylated epoxidized soy oil composites
- 12 August 2005
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 98 (3) , 1325-1338
Impure carbon nanotubes as reinforcements for acrylated epoxidized soy oil composites
- 1 May 2002
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 91 (9) , 6027-6033
Growth of multiwall carbon nanotubes in an inductively coupled plasma reactor
A high density plasma from a methane–hydrogen mixture is generated in an inductively coupled plasma reactor, and multiwalled carbon nanotubes (MWNTs) are grown on silicon substrates with multilayered Al/Fe catalysts. The nanotubes are vertically aligned, and the alignment is better than the orientation commonly seen in thermally grown samples. A detailed parametric study varying inductive power, pressure, temperature, gas composition, catalyst thickness, and power to the substrate is undertaken. Transmission electron microscopy and Raman spectroscopy are used to characterize the nanotubes. Emission spectroscopy and a global model are used to characterize the plasma. The power in the lower electrode holding the substrate influences the morphology and results in a transition from MWNTs to nanofibers as the power is increased.
- 1 May 2002
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 91 (9) , 6027-6033
Growth of multiwall carbon nanotubes in an inductively coupled plasma reactor
A high density plasma from a methane–hydrogen mixture is generated in an inductively coupled plasma reactor, and multiwalled carbon nanotubes (MWNTs) are grown on silicon substrates with multilayered Al/Fe catalysts. The nanotubes are vertically aligned, and the alignment is better than the orientation commonly seen in thermally grown samples. A detailed parametric study varying inductive power, pressure, temperature, gas composition, catalyst thickness, and power to the substrate is undertaken. Transmission electron microscopy and Raman spectroscopy are used to characterize the nanotubes. Emission spectroscopy and a global model are used to characterize the plasma. The power in the lower electrode holding the substrate influences the morphology and results in a transition from MWNTs to nanofibers as the power is increased.