DHDavid Hollis

David Hollis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


David Hollis has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reflection loss correction method for accurate absorbance spectrum analysis of coloured glasses

    by Tarja Volotinen, John M. Parker, David Hollis, Gunnar A. Niklasson

    Four reflection loss correction methods have been investigated, theoretically and by analysing the measured absorbance spectra for eight samples prepared from the same Cu-doped soda–lime–silica glass. Method A, based on the measured refractive indices, was found to be the most practical and accurate. The methods B (subtracting the absorbance of an undoped host glass) and C (subtracting a thinner sample's absorbance spectrum of the same glass) rely on additional measurements of a reference sample. Method A (that only removes the reflection loss from the absorbance) would show most clearly any additional loss due to the sample quality: polished surfaces and inhomogeneities, scattering by the glass structure, or absorption due to the impurities and host glass. Methods B and C would provide errors with similar wavelength dependence as the remaining attenuation coefficient spectrum, which would be very difficult to notice. Method C provides for the best quality samples the same median spectrum as Method A, but shows larger uncertainties than Method A, because the corrected spectrum needs to be multiplied by the inverse thickness difference of the two samples. Method D (subtracting a constant reflection loss) would cause errors due to the wavelength dependence of the glass refractive index.


  • Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis

    by K. Madi, G. Tozzi, Q.H. Zhang, J. Tong, A. Cossey, A. Au, D. Hollis, F. Hild

    Measurements of three-dimensional displacements in a scaffold implant under uniaxial compression have been obtained by two digital volume correlation (DVC) methods, and compared with those obtained from micro-finite element models. The DVC methods were based on two approaches, a local approach which registers independent small volumes and yields discontinuous displacement fields; and a global approach where the registration is performed on the whole volume of interest, leading to continuous displacement fields. A customised mini-compression device was used to perform in situ step-wise compression of the scaffold within a micro-computed tomography (μCT) chamber, and the data were collected at steps of interest. Displacement uncertainties, ranging from 0.006 to 0.02 voxel (i.e. 0.12-0.4 μm), with a strain uncertainty between 60 and 600 με, were obtained with a spatial resolution of 32 voxels using both approaches, although the global approach has lower systematic errors. Reduced displacement and strain uncertainties may be obtained using the global approach by increasing the element size; and using the local approach by increasing the number of intermediary sub-volumes. Good agreements between the results from the DVC measurements and the FE simulations were obtained in the primary loading direction as well as in the lateral directions. This study demonstrates that volumetric strain measurements can be obtained successfully using DVC, which may be a useful tool to investigate mechanical behaviour of porous implants.


  • Open Access

    Tomographic particle image velocimetry of desert locust wakes: instantaneous volumes combine to reveal hidden vortex elements and rapid wake deformation

    by Richard J. Bomphrey, Per Henningsson, Dirk Michaelis, David Hollis

    Aerodynamic structures generated by animals in flight are unstable and complex. Recent progress in quantitative flow visualization has advanced our understanding of animal aerodynamics, but measurements have hitherto been limited to flow velocities at a plane through the wake. We applied an emergent, high-speed, volumetric fluid imaging technique (tomographic particle image velocimetry) to examine segments of the wake of desert locusts, capturing fully three-dimensional instantaneous flow fields. We used those flow fields to characterize the aerodynamic footprint in unprecedented detail and revealed previously unseen wake elements that would have gone undetected by two-dimensional or stereo-imaging technology. Vortex iso-surface topographies show the spatio-temporal signature of aerodynamic force generation manifest in the wake of locusts, and expose the extent to which animal wakes can deform, potentially leading to unreliable calculations of lift and thrust when using conventional diagnostic methods. We discuss implications for experimental design and analysis as volumetric flow imaging becomes more widespread.


  • Assessment of the Deformation of Low Density Polymeric Auxetic Foams by X-Ray Tomography and Digital Volume Correlation

    by Fabrice Pierron, Sam A. McDonald, D. Hollis, Philip J. Withers, A. Alderson

    This paper deals with the use of X-ray tomography and Digital Volume Correlation in order to study the mechanical behaviour of a low density polymeric auxetic foam. First, the metrological performances of the procedure are assessed using rigid body translation. Then, tensile test results are analyzed for two load steps and comments on the deformation process of the foam are given with a specific view to Poisson’s effect.


  • Investigation of the Unsteady Aerodynamics of an Annular Combustor Using PIV and LES

    by Adrian Spencer, David Hollis, Sara Gashi

    Experimental measurements have been carried out which have been used for specifying both boundary conditions of CFD predictions and for validation of the results. Combustor aerodynamics were therefore investigated in the same geometry, using LDA, PIV and LES. Three different LES simulations were performed in order to assess the flow field sensitivity to different boundary conditions. In the first run steady state boundary conditions are specified; in the second run, unsteady conditions at the injector exit and steady conditions in the annuli entry are specified; and in the third run unsteady boundary conditions at both injector exit and annuli entry are specified. A standard RANS simulation is also performed for comparison. The different simulations gave considerably different results. LES results with white noise scaled to give correct inlet turbulence intensities agree reasonably well with experimental data. With steady inflow conditions incorrect prediction of combustor aerodynamics resulted. Introduction of unsteady inflow conditions at the fuel injector exit plane were shown to have a significant effect on the flow interaction between the injector and the primary ports. LES is thus shown to be a good predictive tool for unsteady combustor flow fields. It is still questioned what level of fidelity is required in representing the inlet conditions to best use the predictive ability of LES. It offers significant improvement over standard RANS techniques but LES is more costly and requires detailed experimental data, used carefully, to correctly specify the inflow conditions.


  • PIV Measurements of Combustor Turbulence Fields

    by Adrian Spencer, David Hollis, Jon Carrotte

    An experimental study has been conducted on a full-scale, three-sector, isothermal model of a gas turbine combustor. PIV has been used as the main instrumentation technique and this has been validated against LDA and hot-wire velocity measurements of the same geometry. These data combine to provide high quality boundary condition and validation data for CFD predictions. Substantial care has been taken in assuring the quality of the PIV data. In high turbulence intensity flow fields, low pass spatial filtering can artificially reduce the Reynolds stresses calculated from the PIV measured velocities. The level of this filtering depends upon the ratio of the integral lengthscales in the flow field to the size of the measurement volume of the PIV interrogation cell. Within the highly turbulent flow field of a combustor there exist a very wide range of turbulent length scales. Consideration should therefore be given to any measurements taken in a combustor, hot or cold, to take account of this sub-grid filtering effect. A method is described to overcome this problem and it is demonstrated to be successful by comparing with LDA and PIV data (at increased magnification) that does not suffer this problem. Sparse LDA and HWA data for the combustor is thus complemented by more dense planar PIV data to allow a more complete mapping of the velocity field. This has allowed better understanding of the processes occurring in the combustor such as the jet impingement process and the fuel injector swirler flow interaction with the primary jets. In addition detailed information on turbulence statistics, integral lengthscales, spatial correlation and energetic structure identification is available.


  • Unsteady Surface Pressures Due to Wake Induced Transition in a Laminar Separation Bubble on a LP Turbine Cascade

    by Rory Stieger, David Hollis, Howard Hodson

    This paper presents unsteady surface pressures measured on the suction surface of a LP turbine cascade that was subject to wake passing from a moving bar wake generator. The surface pressures measured under the laminar boundary layer upstream of the steady flow separation point were found to respond to the wake passing as expected from the kinematics of wake convection. In the region where a separation bubble formed in steady flow, the arrival of the convecting wake produced high frequency, short wavelength, fluctuations in the ensemble averaged blade surface pressure. The peak-to-peak magnitude was 30% of the exit dynamic head. The existence of fluctuations in the ensemble averaged pressure traces indicates that they are deterministic and that they are produced by coherent structures. The onset of the pressure fluctuations was found to lie beneath the convecting wake and the fluctuations were found to convect along the blade surface at half of the local freestream velocity. Measurements performed with the boundary layer tripped ahead of the separation point showed no oscillations in the ensemble average pressure traces indicating that a separating boundary layer is necessary for the generation of the pressure fluctuations. The coherent structures responsible for the large amplitude pressure fluctuations were identified using PIV to be vortices embedded in the boundary layer. It is proposed that these vortices form in the boundary layer as the wake passes over the inflexional velocity profiles of the separating boundary layer and that the rollup of the separated shear layer occurs by an inviscid Kelvin-Helmholtz mechanism.


  • Excited State Absorption in Tb Activated Phosphor Powders

    by R. Raue, D. A. Young, L. M. dos Santos, H. C. G. Verhaar, T. Monteiro, S. Albin, H. von Seggern, G. E. Giakoumakis, R. Chapoulie, K. C. Mishra, et al.