Maoqi Chen
Research Subjects
Research Interests
Maoqi Chen has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Ping Zhou
School of Rehabilitation Sciences and Engineering, University of Health and Rehabilitation Sciences, Qingdao, China
13 shared publications - Xu Zhang
School of Microelectronics, University of Science and Technology of China, Hefei, China
6 shared publications - Chengjun Huang
Department of Neuroscience, Baylor College of Medicine, Houston, TX 77030, USA
4 shared publications - Haowen Zhao
School of Microelectronics, University of Science and Technology of China, Hefei, Anhui 230002, P. R. China
3 shared publications - Xiang Chen
School of Microelectronics, University of Science and Technology of China, Hefei, Anhui 230002, P. R. China
3 shared publications - Cliff S. Klein
Guangdong Work Injury Rehabilitation Center, Guangzhou, China
2 shared publications
Latest Publications
- 22 September 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056015
Motor unit number estimation based on convolutional neural network
Objective. The compound muscle action potential (CMAP) scan contains a muscle’s detailed stimulus-activation information and thereby can be used for motor unit number estimation (MUNE). Due to the challenges in accurately obtaining the motor unit numbers from experimental CMAP scans, most existing MUNE methods rely on data fitting, which is time-consuming and requires manual operations. This study explored the feasibility of a neural network-based MUNE approach and proposes an end-to-end model for rapid estimation. Approach. We developed NNEstimation, a novel supervised learning framework based on a convolutional neural network, to estimate motor unit numbers from both synthetic and experimental CMAP scans. A probabilistic model with varied parameters was used to generate CMAP scans with diverse characteristics for neural network training. NNEstimation trained on synthetic data was directly tested on both synthetic and experimental data. Main results. Evaluations on synthetic CMAP scans demonstrate that NNEstimation achieves lower estimation error and shorter execution time than the conventional data fitting method, MScanFit. The accuracy of NNEstimation is influenced by motor unit numbers of CMAP scans and remains unaffected by noise levels, recorded amplitudes, or motor unit activation thresholds. Moreover, NNEstimation’s estimates on experimental data are highly consistent with those of MScanFit. Significance. Although trained solely on synthetic CMAP scans, NNEstimation achieves estimation results comparable to those of the traditional algorithm on experimental data while significantly reducing execution time, demonstrating its potential for practical MUNE applications.
- 22 September 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (5) , 056015
Motor unit number estimation based on convolutional neural network
Objective. The compound muscle action potential (CMAP) scan contains a muscle’s detailed stimulus-activation information and thereby can be used for motor unit number estimation (MUNE). Due to the challenges in accurately obtaining the motor unit numbers from experimental CMAP scans, most existing MUNE methods rely on data fitting, which is time-consuming and requires manual operations. This study explored the feasibility of a neural network-based MUNE approach and proposes an end-to-end model for rapid estimation. Approach. We developed NNEstimation, a novel supervised learning framework based on a convolutional neural network, to estimate motor unit numbers from both synthetic and experimental CMAP scans. A probabilistic model with varied parameters was used to generate CMAP scans with diverse characteristics for neural network training. NNEstimation trained on synthetic data was directly tested on both synthetic and experimental data. Main results. Evaluations on synthetic CMAP scans demonstrate that NNEstimation achieves lower estimation error and shorter execution time than the conventional data fitting method, MScanFit. The accuracy of NNEstimation is influenced by motor unit numbers of CMAP scans and remains unaffected by noise levels, recorded amplitudes, or motor unit activation thresholds. Moreover, NNEstimation’s estimates on experimental data are highly consistent with those of MScanFit. Significance. Although trained solely on synthetic CMAP scans, NNEstimation achieves estimation results comparable to those of the traditional algorithm on experimental data while significantly reducing execution time, demonstrating its potential for practical MUNE applications.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2229-2236
Two-Source Validation of Online Surface EMG Decomposition Using Progressive FastICA Peel-Off
Recently, great interests have been attracted on the online decomposition of surface electromyogram (SEMG) but current studies mainly performed validation on simulated EMG signals due to the fact that real MU activities in experimental signals were unknown. For a more comprehensive assessment of online SEMG decomposition, a two-source validation was conducted by simultaneously collecting intramuscular EMG (IEMG) and high-density SEMG signals. The IEMG signal was decomposed using a simplified version of Progressive FastICA Peel-off (PFP) method with a combination of the peel-off strategy and the valley-seeking clustering, and the decomposed motor unit (MU) spike trains were used as the ground-truth reference. For SEMG recordings, the signals within initial 5 seconds were used to offline obtain MU separation vectors and these vectors were subsequently employed to extract MU spike trains in the online stage. The matching rate of the common firing events from the ground-truth reference and online SEMG decomposition were calculated and assessed. A total of 549 and 92 MUs were identified from the SEMG and IEMG signals from 5 healthy subjects’ first dorsal interosseous muscle. All the MUs decomposed from IEMG can be matched with MUs from online SEMG decomposition and the average matching rate in the online stage was (96 ± 1) %. The results highlighted the ability of separation vectors to continuously and precisely track the same MU in the experimental SEMG signals. Our study provides a more comprehensive validation perspective of online SEMG decomposition on the experimental data.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (7) , 2229-2236
Two-Source Validation of Online Surface EMG Decomposition Using Progressive FastICA Peel-Off
Recently, great interests have been attracted on the online decomposition of surface electromyogram (SEMG) but current studies mainly performed validation on simulated EMG signals due to the fact that real MU activities in experimental signals were unknown. For a more comprehensive assessment of online SEMG decomposition, a two-source validation was conducted by simultaneously collecting intramuscular EMG (IEMG) and high-density SEMG signals. The IEMG signal was decomposed using a simplified version of Progressive FastICA Peel-off (PFP) method with a combination of the peel-off strategy and the valley-seeking clustering, and the decomposed motor unit (MU) spike trains were used as the ground-truth reference. For SEMG recordings, the signals within initial 5 seconds were used to offline obtain MU separation vectors and these vectors were subsequently employed to extract MU spike trains in the online stage. The matching rate of the common firing events from the ground-truth reference and online SEMG decomposition were calculated and assessed. A total of 549 and 92 MUs were identified from the SEMG and IEMG signals from 5 healthy subjects’ first dorsal interosseous muscle. All the MUs decomposed from IEMG can be matched with MUs from online SEMG decomposition and the average matching rate in the online stage was (96 ± 1) %. The results highlighted the ability of separation vectors to continuously and precisely track the same MU in the experimental SEMG signals. Our study provides a more comprehensive validation perspective of online SEMG decomposition on the experimental data.
- 18 February 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 160, 111-112
StairFit MUNE: A free and open source MatLab program for CMAP scan processing
- 18 February 2024
- Published by Elsevier in Clinical Neurophysiology
- Vol. 160, 111-112
StairFit MUNE: A free and open source MatLab program for CMAP scan processing
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1257-1268
Adaptive Online Decomposition of Surface EMG Using Progressive FastICA Peel-Off
This study presents a method for adaptive online decomposition of high-density surface electromyogram (SEMG) signals to overcome the performance degradation during long-term recordings. The proposed method utilized the progressive FastICA peel-off (PFP) method and integrated a practical double-thread-parallel algorithm into the conventional two-stage calculation approach. During the offline initialization stage, a set of separation vectors was computed. In the subsequent online decomposition stage, a backend thread was implemented to periodically update the separation vectors using the constrained FastICA algorithm and the automatic PFP method. Concurrently, the frontend thread employed the newly updated separation vectors to accurately extract motor unit (MU) spike trains in real time. To assess the effectiveness of the proposed method, simulated and experimental SEMG signals from abductor pollicis brevis muscles of ten subjects were used for evaluation. The results demonstrated that the proposed method outperformed the conventional method, which relies on fixed separation vectors. Specifically, the proposed method showed an improved matching rate by 3.63% in simulated data and 1.98% in experimental data, along with an increased motor unit number by 2.39 in simulated data and 1.30 in experimental data. These findings illustrated the feasibility of the proposed method to enhance the performance of online SEMG decomposition. As a result, this work holds promise for various applications that require accurate MU firing activities in decoding neural commands and building neural-machine interfaces.
- 9 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1257-1268
Adaptive Online Decomposition of Surface EMG Using Progressive FastICA Peel-Off
This study presents a method for adaptive online decomposition of high-density surface electromyogram (SEMG) signals to overcome the performance degradation during long-term recordings. The proposed method utilized the progressive FastICA peel-off (PFP) method and integrated a practical double-thread-parallel algorithm into the conventional two-stage calculation approach. During the offline initialization stage, a set of separation vectors was computed. In the subsequent online decomposition stage, a backend thread was implemented to periodically update the separation vectors using the constrained FastICA algorithm and the automatic PFP method. Concurrently, the frontend thread employed the newly updated separation vectors to accurately extract motor unit (MU) spike trains in real time. To assess the effectiveness of the proposed method, simulated and experimental SEMG signals from abductor pollicis brevis muscles of ten subjects were used for evaluation. The results demonstrated that the proposed method outperformed the conventional method, which relies on fixed separation vectors. Specifically, the proposed method showed an improved matching rate by 3.63% in simulated data and 1.98% in experimental data, along with an increased motor unit number by 2.39 in simulated data and 1.30 in experimental data. These findings illustrated the feasibility of the proposed method to enhance the performance of online SEMG decomposition. As a result, this work holds promise for various applications that require accurate MU firing activities in decoding neural commands and building neural-machine interfaces.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 160-170
Online Decomposition of Surface Electromyogram Into Individual Motor Unit Activities Using Progressive FastICA Peel-Off
Surface electromyogram (SEMG) decomposition provides a promising tool for decoding and understanding neural drive information non-invasively. In contrast to previous SEMG decomposition methods mainly developed in offline conditions, there are few studies on online SEMG decomposition. A novel method for online decomposition of SEMG data is presented using the progressive FastICA peel-off (PFP) method. The proposed online method utilized a two-stage approach, consisting of an offline prework stage for initializing high-quality separation vectors through the offline PFP algorithm, and an online decomposition stage for estimating source signals of different motor units by applying these vectors to the input SEMG data stream. Specifically, a new successive multi-threshold Otsu algorithm was developed in the online stage for determining each motor unit spike train (MUST) precisely with fast and simple computations (to replace a time-consuming iterative threshold setting in the original PFP method). The performance of the proposed online SEMG decomposition method was evaluated by both simulation and experimental approaches. When processing simulated SEMG data, the online PFP method achieved a decomposition accuracy of 97.37%, superior to that (95.1%) of an online method with a traditional k-means clustering algorithm for MUST extraction. Our method was also found to achieve superior performance at higher noise levels. For decomposing experimental SEMG data, the online PFP method was able to extract an average of 12.00 ± 3.46 MUs per trial, with a matching rate of 90.38%, with respect to the expert-guided offline decomposition results. Our study provides a valuable way of online decomposition of SEMG data with advanced applications in movement control and health.
- 11 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (1) , 160-170
Online Decomposition of Surface Electromyogram Into Individual Motor Unit Activities Using Progressive FastICA Peel-Off
Surface electromyogram (SEMG) decomposition provides a promising tool for decoding and understanding neural drive information non-invasively. In contrast to previous SEMG decomposition methods mainly developed in offline conditions, there are few studies on online SEMG decomposition. A novel method for online decomposition of SEMG data is presented using the progressive FastICA peel-off (PFP) method. The proposed online method utilized a two-stage approach, consisting of an offline prework stage for initializing high-quality separation vectors through the offline PFP algorithm, and an online decomposition stage for estimating source signals of different motor units by applying these vectors to the input SEMG data stream. Specifically, a new successive multi-threshold Otsu algorithm was developed in the online stage for determining each motor unit spike train (MUST) precisely with fast and simple computations (to replace a time-consuming iterative threshold setting in the original PFP method). The performance of the proposed online SEMG decomposition method was evaluated by both simulation and experimental approaches. When processing simulated SEMG data, the online PFP method achieved a decomposition accuracy of 97.37%, superior to that (95.1%) of an online method with a traditional k-means clustering algorithm for MUST extraction. Our method was also found to achieve superior performance at higher noise levels. For decomposing experimental SEMG data, the online PFP method was able to extract an average of 12.00 ± 3.46 MUs per trial, with a matching rate of 90.38%, with respect to the expert-guided offline decomposition results. Our study provides a valuable way of online decomposition of SEMG data with advanced applications in movement control and health.
- Open Access
- 12 April 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (4) , 469
Spatial Dependence of Log-Transformed Electromyography–Force Relation: Model-Based Sensitivity Analysis and Experimental Study of Biceps Brachii
This study investigated electromyography (EMG)–force relations using both simulated and experimental approaches. A motor neuron pool model was first implemented to simulate EMG–force signals, focusing on three different conditions that test the effects of small or large motor units located more or less superficially in the muscle. It was found that the patterns of the EMG–force relations varied significantly across the simulated conditions, quantified by the slope (b) of the log-transformed EMG-force relation. b was significantly higher for large motor units, which were preferentially located superficially rather than for random depth or deep depth conditions (p < 0.001). The log-transformed EMG–force relations in the biceps brachii muscles of nine healthy subjects were examined using a high-density surface EMG. The slope (b) distribution of the relation across the electrode array showed a spatial dependence; b in the proximal region was significantly larger than the distal region, whereas b was not different between the lateral and medial regions. The findings of this study provide evidence that the log-transformed EMG–force relations are sensitive to different motor unit spatial distributions. The slope (b) of this relation may prove to be a useful adjunct measure in the investigation of muscle or motor unit changes associated with disease, injury, or aging.
- 12 April 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (4) , 469
Open AccessSpatial Dependence of Log-Transformed Electromyography–Force Relation: Model-Based Sensitivity Analysis and Experimental Study of Biceps Brachii
This study investigated electromyography (EMG)–force relations using both simulated and experimental approaches. A motor neuron pool model was first implemented to simulate EMG–force signals, focusing on three different conditions that test the effects of small or large motor units located more or less superficially in the muscle. It was found that the patterns of the EMG–force relations varied significantly across the simulated conditions, quantified by the slope (b) of the log-transformed EMG-force relation. b was significantly higher for large motor units, which were preferentially located superficially rather than for random depth or deep depth conditions (p < 0.001). The log-transformed EMG–force relations in the biceps brachii muscles of nine healthy subjects were examined using a high-density surface EMG. The slope (b) distribution of the relation across the electrode array showed a spatial dependence; b in the proximal region was significantly larger than the distal region, whereas b was not different between the lateral and medial regions. The findings of this study provide evidence that the log-transformed EMG–force relations are sensitive to different motor unit spatial distributions. The slope (b) of this relation may prove to be a useful adjunct measure in the investigation of muscle or motor unit changes associated with disease, injury, or aging.
- 11 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (10) , 2834-2840
Sensitivity Analysis of CMAP Scan Step Index to Different Stimulation Parameters and Examination of Muscles Affected by Spinal Cord Injury
Step index (STEPIX) is a recently developed compound muscle action potential (CMAP) scan method for evaluating motor unit loss and remodeling changes. This study investigates the influence of different stimulation parameters during CMAP scan on STEPIX and its examination of muscles affected by spinal cord injury (SCI). CMAP scan of the first dorsal interosseous (FDI) muscle was performed using different stimulus pulse widths (0.1 ms, 0.2 ms) and different numbers of stimuli (500, 1000) in 12 neurologically intact subjects. STEPIX was derived from each CMAP scan of all subjects. A significantly higher STEPIX was obtained using 1000 stimuli than 500 stimuli, while no significant difference in STEPIX was observed using 0.1 and 0.2 ms stimulus pulse widths. STEPIX was further applied to process CMAP scans of the FDI muscle from 13 tetraplegia and 13 healthy control subjects using the same stimulation parameter setting (0.1 ms, 500 stimuli), along with other methods including MScanFit motor unit number estimation (MUNE) and D50. STEPIX was significantly lower for the SCI subjects compared with the healthy control subjects. STEPIX was significantly correlated with MscanFit MUNE and D50, but had a smaller relative width of the overlapping zone (WOZ%) between tetraplegic and healthy control groups compared with MScanFit MUNE and D50. The findings of the study highlight the importance of maintaining a consistent stimulation parameter setting in CMAP scan studies and confirm the usefulness of STEPIX as a convenient CMAP scan parameter for examination of motor unit number changes.
- 11 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (10) , 2834-2840
Sensitivity Analysis of CMAP Scan Step Index to Different Stimulation Parameters and Examination of Muscles Affected by Spinal Cord Injury
Step index (STEPIX) is a recently developed compound muscle action potential (CMAP) scan method for evaluating motor unit loss and remodeling changes. This study investigates the influence of different stimulation parameters during CMAP scan on STEPIX and its examination of muscles affected by spinal cord injury (SCI). CMAP scan of the first dorsal interosseous (FDI) muscle was performed using different stimulus pulse widths (0.1 ms, 0.2 ms) and different numbers of stimuli (500, 1000) in 12 neurologically intact subjects. STEPIX was derived from each CMAP scan of all subjects. A significantly higher STEPIX was obtained using 1000 stimuli than 500 stimuli, while no significant difference in STEPIX was observed using 0.1 and 0.2 ms stimulus pulse widths. STEPIX was further applied to process CMAP scans of the FDI muscle from 13 tetraplegia and 13 healthy control subjects using the same stimulation parameter setting (0.1 ms, 500 stimuli), along with other methods including MScanFit motor unit number estimation (MUNE) and D50. STEPIX was significantly lower for the SCI subjects compared with the healthy control subjects. STEPIX was significantly correlated with MscanFit MUNE and D50, but had a smaller relative width of the overlapping zone (WOZ%) between tetraplegic and healthy control groups compared with MScanFit MUNE and D50. The findings of the study highlight the importance of maintaining a consistent stimulation parameter setting in CMAP scan studies and confirm the usefulness of STEPIX as a convenient CMAP scan parameter for examination of motor unit number changes.
- Open Access
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 22-30
A Novel Muscle Innervation Zone Estimation Method Using Monopolar High Density Surface Electromyography
This study presents a novel method to estimate a muscle’s innervation zone (IZ) location from monopolar high density surface electromyography (EMG) signals. Based on the fact that 2 nd principal component coefficients derived from principal component analysis (PCA) are linearly related with the time delay of different channels, the channels located near the IZ should have the shortest time delays. Accordingly, we applied a novel method to estimate a muscle’s IZ based on PCA. The performance of the developed method was evaluated by both simulation and experimental approaches. The method based on 2 nd principal component of monopolar high density surface EMG achieved a comparable performance to cross-correlation analysis of bipolar signals when noise was simulated to be independently distributed across all channels. However, in simulated conditions of specific channel contamination, the PCA based method achieved superior performance than the cross-correlation method. Experimental high density surface EMG was recorded from the biceps brachii of 9 healthy subjects during maximum voluntary contractions. The PCA and cross-correlation based methods achieved high agreement, with a difference in IZ location of 0.47 ± 0.4 IED (inter-electrode distance = 8 mm). The results indicate that analysis of 2 nd principal component coefficients provides a useful approach for IZ estimation using monopolar high density surface EMG.
- 19 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 22-30
Open AccessA Novel Muscle Innervation Zone Estimation Method Using Monopolar High Density Surface Electromyography
This study presents a novel method to estimate a muscle’s innervation zone (IZ) location from monopolar high density surface electromyography (EMG) signals. Based on the fact that 2 nd principal component coefficients derived from principal component analysis (PCA) are linearly related with the time delay of different channels, the channels located near the IZ should have the shortest time delays. Accordingly, we applied a novel method to estimate a muscle’s IZ based on PCA. The performance of the developed method was evaluated by both simulation and experimental approaches. The method based on 2 nd principal component of monopolar high density surface EMG achieved a comparable performance to cross-correlation analysis of bipolar signals when noise was simulated to be independently distributed across all channels. However, in simulated conditions of specific channel contamination, the PCA based method achieved superior performance than the cross-correlation method. Experimental high density surface EMG was recorded from the biceps brachii of 9 healthy subjects during maximum voluntary contractions. The PCA and cross-correlation based methods achieved high agreement, with a difference in IZ location of 0.47 ± 0.4 IED (inter-electrode distance = 8 mm). The results indicate that analysis of 2 nd principal component coefficients provides a useful approach for IZ estimation using monopolar high density surface EMG.
- Open Access
- 1 December 2021
- Published by Elsevier in Medicine in Novel Technology and Devices
- Vol. 12, 100094
Automatic decomposition of pediatric high density surface EMG: A pilot study
- 1 December 2021
- Published by Elsevier in Medicine in Novel Technology and Devices
- Vol. 12, 100094
Open AccessAutomatic decomposition of pediatric high density surface EMG: A pilot study
- Open Access
- 27 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (10) , 356
Neurophysiological Factors Affecting Muscle Innervation Zone Estimation Using Surface EMG: A Simulation Study
Surface electromyography (EMG) recorded by a linear or 2-dimensional electrode array can be used to estimate the location of muscle innervation zones (IZ). There are various neurophysiological factors that may influence surface EMG and thus potentially compromise muscle IZ estimation. The objective of this study was to evaluate how surface-EMG-based IZ estimation might be affected by different factors, including varying degrees of motor unit (MU) synchronization in the case of single or double IZs. The study was performed by implementing a model simulating surface EMG activity. Three different MU synchronization conditions were simulated, namely no synchronization, medium level synchronization, and complete synchronization analog to M wave. Surface EMG signals recorded by a 2-dimensional electrode array were simulated from a muscle with single and double IZs, respectively. For each situation, the IZ was estimated from surface EMG and compared with the one used in the model for performance evaluation. For the muscle with only one IZ, the estimated IZ location from surface EMG was consistent with the one used in the model for all the three MU synchronization conditions. For the muscle with double IZs, at least one IZ was appropriately estimated from interference surface EMG when there was no MU synchronization. However, the estimated IZ was different from either of the two IZ locations used in the model for the other two MU synchronization conditions. For muscles with a single IZ, MU synchronization has little effect on IZ estimation from electrode array surface EMG. However, caution is required for multiple IZ muscles since MU synchronization might lead to false IZ estimation.
- 27 September 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (10) , 356
Open AccessNeurophysiological Factors Affecting Muscle Innervation Zone Estimation Using Surface EMG: A Simulation Study
Surface electromyography (EMG) recorded by a linear or 2-dimensional electrode array can be used to estimate the location of muscle innervation zones (IZ). There are various neurophysiological factors that may influence surface EMG and thus potentially compromise muscle IZ estimation. The objective of this study was to evaluate how surface-EMG-based IZ estimation might be affected by different factors, including varying degrees of motor unit (MU) synchronization in the case of single or double IZs. The study was performed by implementing a model simulating surface EMG activity. Three different MU synchronization conditions were simulated, namely no synchronization, medium level synchronization, and complete synchronization analog to M wave. Surface EMG signals recorded by a 2-dimensional electrode array were simulated from a muscle with single and double IZs, respectively. For each situation, the IZ was estimated from surface EMG and compared with the one used in the model for performance evaluation. For the muscle with only one IZ, the estimated IZ location from surface EMG was consistent with the one used in the model for all the three MU synchronization conditions. For the muscle with double IZs, at least one IZ was appropriately estimated from interference surface EMG when there was no MU synchronization. However, the estimated IZ was different from either of the two IZ locations used in the model for the other two MU synchronization conditions. For muscles with a single IZ, MU synchronization has little effect on IZ estimation from electrode array surface EMG. However, caution is required for multiple IZ muscles since MU synchronization might lead to false IZ estimation.