Joseph I. Pacold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Joseph I. Pacold has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
Alex Berndt
3 shared publicationsBenjamin T Houseman
3 shared publicationsBrian A. Mattern
Department of Physics, University of Washington, Seattle, Washington 98195, United States
3 shared publicationsChristian Rommel
3 shared publicationsDaniel D Le
3 shared publicationsFabrice Gorrec
3 shared publications
Latest Publications
- 24 April 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (3)
Chemical speciation correlated with microstructural heterogeneity of interdicted uranium materials
Two uranium powders seized by law enforcement in Victoria, Australia, have been characterized by established nuclear forensic methods in a previously published study. Here, the results of further characterization by a scanning transmission x-ray microscope (STXM) operating in the soft x-ray regime are reported. STXM images are used to estimate the elemental distribution in micrometer-scale particles of each powder, and oxygen K-edge absorption spectra are used to determine the chemical state of uranium. The results of the current study are consistent with the previous analysis; the first powder is found to be a potassium-uranium hydrate, while the second powder is determined to be a mixture of uranium oxides primarily consisting of UO3.
- 24 April 2025
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 43 (3)
Chemical speciation correlated with microstructural heterogeneity of interdicted uranium materials
Two uranium powders seized by law enforcement in Victoria, Australia, have been characterized by established nuclear forensic methods in a previously published study. Here, the results of further characterization by a scanning transmission x-ray microscope (STXM) operating in the soft x-ray regime are reported. STXM images are used to estimate the elemental distribution in micrometer-scale particles of each powder, and oxygen K-edge absorption spectra are used to determine the chemical state of uranium. The results of the current study are consistent with the previous analysis; the first powder is found to be a potassium-uranium hydrate, while the second powder is determined to be a mixture of uranium oxides primarily consisting of UO3.
- Open Access
- 16 May 2022
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 40 (4)
Submicrometer spectromicroscopy of UO2 aged under high humidity conditions
The oxidation of uranium dioxide is a complicated process, depending on factors including humidity, temperature, and microstructure. To further determine the characteristics of this process, UO2 particles were allowed to age and agglomerate under 98% relative humidity at room temperature for 378 days. A focused ion beam (FIB) section of this agglomeration was then measured at the O K-edge, U N5-edge, and C K-edge using the scanning transmission x-ray microscope (STXM) at the Advanced Light Source. O K-edge and U N5-edge x-ray absorption measurements allowed for the elemental and chemical species mapping of the agglomerates and indicated the formation of schoepite at the submicrometer scale in specific locations. Non-negative matrix factorization was employed to elucidate the main components at the O K-edge, which were uranyl (schoepite) formed primarily at the interface of the sample with controlled atmosphere, a UO2-like bulk component present in the majority of the sample, and an oxygen species present at the surface of the FIB section, which is likely adsorbed water. STXM spectromicroscopy measurements at the U N5-edge measurements also confirmed the location of oxidized uranium. This analysis is a valuable insight into the formation of schoepite on UO2 and shows the sensitivity to and utility of STXM spectromicroscopy for uranium speciation.
- 16 May 2022
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 40 (4)
Open AccessSubmicrometer spectromicroscopy of UO2 aged under high humidity conditions
The oxidation of uranium dioxide is a complicated process, depending on factors including humidity, temperature, and microstructure. To further determine the characteristics of this process, UO2 particles were allowed to age and agglomerate under 98% relative humidity at room temperature for 378 days. A focused ion beam (FIB) section of this agglomeration was then measured at the O K-edge, U N5-edge, and C K-edge using the scanning transmission x-ray microscope (STXM) at the Advanced Light Source. O K-edge and U N5-edge x-ray absorption measurements allowed for the elemental and chemical species mapping of the agglomerates and indicated the formation of schoepite at the submicrometer scale in specific locations. Non-negative matrix factorization was employed to elucidate the main components at the O K-edge, which were uranyl (schoepite) formed primarily at the interface of the sample with controlled atmosphere, a UO2-like bulk component present in the majority of the sample, and an oxygen species present at the surface of the FIB section, which is likely adsorbed water. STXM spectromicroscopy measurements at the U N5-edge measurements also confirmed the location of oxidized uranium. This analysis is a valuable insight into the formation of schoepite on UO2 and shows the sensitivity to and utility of STXM spectromicroscopy for uranium speciation.
- Open Access
- 18 May 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (19) , 195102
Chemical speciation of U, Fe, and Pu in melt glass from nuclear weapons testing
Nuclear weapons testing generates large volumes of glassy materials that influence the transport of dispersed actinides in the environment and may carry information on the composition of the detonated device. We determine the oxidation state of U and Fe (which is known to buffer the oxidation state of actinide elements and to affect the redox state of groundwater) in samples of melt glass collected from three U.S. nuclear weapons tests. For selected samples, we also determine the coordination geometry of U and Fe, and we report the oxidation state of Pu from one melt glass sample. We find significant variations among the melt glass samples and, in particular, find a clear deviation in one sample from the expected buffering effect of Fe(II)/Fe(III) on the oxidation state of uranium. In the first direct measurement of Pu oxidation state in a nuclear test melt glass, we obtain a result consistent with existing literature that proposes Pu is primarily present as Pu(IV) in post-detonation material. In addition, our measurements imply that highly mobile U(VI) may be produced in significant quantities when melt glass is quenched rapidly following a nuclear detonation, though these products may remain immobile in the vitrified matrices. The observed differences in chemical state among the three samples show that redox conditions can vary dramatically across different nuclear test conditions. The local soil composition, associated device materials, and the rate of quenching are all likely to affect the final redox state of the glass. The resulting variations in glass chemistry are significant for understanding and interpreting debris chemistry and the later environmental mobility of dispersed material.
- 18 May 2016
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 119 (19) , 195102
Open AccessChemical speciation of U, Fe, and Pu in melt glass from nuclear weapons testing
Nuclear weapons testing generates large volumes of glassy materials that influence the transport of dispersed actinides in the environment and may carry information on the composition of the detonated device. We determine the oxidation state of U and Fe (which is known to buffer the oxidation state of actinide elements and to affect the redox state of groundwater) in samples of melt glass collected from three U.S. nuclear weapons tests. For selected samples, we also determine the coordination geometry of U and Fe, and we report the oxidation state of Pu from one melt glass sample. We find significant variations among the melt glass samples and, in particular, find a clear deviation in one sample from the expected buffering effect of Fe(II)/Fe(III) on the oxidation state of uranium. In the first direct measurement of Pu oxidation state in a nuclear test melt glass, we obtain a result consistent with existing literature that proposes Pu is primarily present as Pu(IV) in post-detonation material. In addition, our measurements imply that highly mobile U(VI) may be produced in significant quantities when melt glass is quenched rapidly following a nuclear detonation, though these products may remain immobile in the vitrified matrices. The observed differences in chemical state among the three samples show that redox conditions can vary dramatically across different nuclear test conditions. The local soil composition, associated device materials, and the rate of quenching are all likely to affect the final redox state of the glass. The resulting variations in glass chemistry are significant for understanding and interpreting debris chemistry and the later environmental mobility of dispersed material.
- 16 March 2016
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 45 (24) , 9948-9961
Evidence for 5d-σ and 5d-π covalency in lanthanide sesquioxides from oxygen K-edge X-ray absorption spectroscopy
The electronic structure in the complete series of stable lanthanide sesquioxides, Ln2O3 (Ln = La to Lu, except radioactive Pm), has been evaluated using oxygen K-edge X-ray absorption spectroscopy with a scanning transmission X-ray microscope (STXM).
- 16 March 2016
- Published by Royal Society of Chemistry (RSC) in Dalton Transactions
- Vol. 45 (24) , 9948-9961
Evidence for 5d-σ and 5d-π covalency in lanthanide sesquioxides from oxygen K-edge X-ray absorption spectroscopy
The electronic structure in the complete series of stable lanthanide sesquioxides, Ln2O3 (Ln = La to Lu, except radioactive Pm), has been evaluated using oxygen K-edge X-ray absorption spectroscopy with a scanning transmission X-ray microscope (STXM).
- 17 December 2015
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 55 (1) , 114-124
Effects of Ligand Geometry on the Photophysical Properties of Photoluminescent Eu(III) and Sm(III) 1-Hydroxypyridin-2-one Complexes in Aqueous Solution
A series of 10 tetradentate 1-hydroxy-pyridin-2-one (1,2-HOPO) ligands and corresponding eight-coordinated photoluminescent Eu(III) and Sm(III) complexes were prepared. Generally, the ligands differ by the linear (nLI) aliphatic linker length, from 2 to 8 methylene units between the bidentate 1,2-HOPO chelator units. The photoluminescent quantum yields (Φtot) were found to vary with the linker length, and the same trend was observed for the Eu(III) and Sm(III) complexes. The 2LI and 5LI bridged complexes are the brightest (Φtotxε). The change in ligand wrapping pattern between 2LI and 5LI complexes observed by X-ray diffraction (XRD) is further supported by density functional theory (DFT) calculations. The bimodal Φtot trends of the Eu(III) and Sm(III) complexes are rationalized by the change in ligand wrapping pattern as the bridge (nLI) is increased in length.
- 17 December 2015
- Published by American Chemical Society (ACS) in Inorganic Chemistry
- Vol. 55 (1) , 114-124
Effects of Ligand Geometry on the Photophysical Properties of Photoluminescent Eu(III) and Sm(III) 1-Hydroxypyridin-2-one Complexes in Aqueous Solution
A series of 10 tetradentate 1-hydroxy-pyridin-2-one (1,2-HOPO) ligands and corresponding eight-coordinated photoluminescent Eu(III) and Sm(III) complexes were prepared. Generally, the ligands differ by the linear (nLI) aliphatic linker length, from 2 to 8 methylene units between the bidentate 1,2-HOPO chelator units. The photoluminescent quantum yields (Φtot) were found to vary with the linker length, and the same trend was observed for the Eu(III) and Sm(III) complexes. The 2LI and 5LI bridged complexes are the brightest (Φtotxε). The change in ligand wrapping pattern between 2LI and 5LI complexes observed by X-ray diffraction (XRD) is further supported by density functional theory (DFT) calculations. The bimodal Φtot trends of the Eu(III) and Sm(III) complexes are rationalized by the change in ligand wrapping pattern as the bridge (nLI) is increased in length.
- 1 November 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 113906
A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements
We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 106–107 photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.
- 1 November 2014
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (11) , 113906
A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements
We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 106–107 photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.
- 5 August 2014
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 70 (a1) , C222
A Rebirth of Laboratory XANES and XES
We have recently launched a reinvestigation of laboratory-based measurement of x-ray absorption near edge structure (XANES) and high-resolution x-ray emission spectroscopy (XES). Driven by the roughly one-hundred-fold improvement in the efficiency of high resolution x-ray optics compared to the 1970's, we have demonstrated that surprisingly impressive performance is now possible with laboratory XES instruments and that quite useful performance is possible for laboratory XANES. For applications in the 5 keV- 10 keV energy range, i.e., appropriate for 3d transition metal K edges and lanthanide L edges, we find XES performance that is intermediate between what can be achieved at bending-magnet and insertion-device beamlines at third generation synchrotron light sources. In the same energy range, we find that high quality XANES measurements can be performed in transmission mode on concentrated samples with the present instrument and should be possible, in many cases, in fluorescence mode after a planned upgrade brings the monochromatic beam flux up to approximately 10M/sec.
- 5 August 2014
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations and Advances
- Vol. 70 (a1) , C222
A Rebirth of Laboratory XANES and XES
We have recently launched a reinvestigation of laboratory-based measurement of x-ray absorption near edge structure (XANES) and high-resolution x-ray emission spectroscopy (XES). Driven by the roughly one-hundred-fold improvement in the efficiency of high resolution x-ray optics compared to the 1970's, we have demonstrated that surprisingly impressive performance is now possible with laboratory XES instruments and that quite useful performance is possible for laboratory XANES. For applications in the 5 keV- 10 keV energy range, i.e., appropriate for 3d transition metal K edges and lanthanide L edges, we find XES performance that is intermediate between what can be achieved at bending-magnet and insertion-device beamlines at third generation synchrotron light sources. In the same energy range, we find that high quality XANES measurements can be performed in transmission mode on concentrated samples with the present instrument and should be possible, in many cases, in fluorescence mode after a planned upgrade brings the monochromatic beam flux up to approximately 10M/sec.
- 7 March 2014
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 136 (11) , 4186-4191
Direct Observation of 4f Intrashell Excitation in Luminescent Eu Complexes by Time-Resolved X-ray Absorption Near Edge Spectroscopy
We report time-resolved X-ray absorption near edge structure (TR-XANES) measurements at the Eu L3 edge upon photoexcitation of several EuIII-based luminescent lanthanide complexes. We find an unambiguous signature of the 4f intrashell excitation that occurs upon energy transfer from the photoactive organic antennas to the lanthanide species. Phenomenologically, this observation provides the basis for direct investigation of a crucial step in the energy transfer pathways that lead to sensitized luminescence in lanthanide-based dyes. Interestingly, the details of the TR-XANES feature suggest that the degree of 4f–5d hybridization may itself vary depending on the excited state of the EuIII ion.
- 7 March 2014
- Published by American Chemical Society (ACS) in Journal of the American Chemical Society
- Vol. 136 (11) , 4186-4191
Direct Observation of 4f Intrashell Excitation in Luminescent Eu Complexes by Time-Resolved X-ray Absorption Near Edge Spectroscopy
We report time-resolved X-ray absorption near edge structure (TR-XANES) measurements at the Eu L3 edge upon photoexcitation of several EuIII-based luminescent lanthanide complexes. We find an unambiguous signature of the 4f intrashell excitation that occurs upon energy transfer from the photoactive organic antennas to the lanthanide species. Phenomenologically, this observation provides the basis for direct investigation of a crucial step in the energy transfer pathways that lead to sensitized luminescence in lanthanide-based dyes. Interestingly, the details of the TR-XANES feature suggest that the degree of 4f–5d hybridization may itself vary depending on the excited state of the EuIII ion.
- 26 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 3 (14) , 1858-1864
Fast Detection Allowing Analysis of Metalloprotein Electronic Structure by X-ray Emission Spectroscopy at Room Temperature
The paradigm of “detection-before-destruction” was tested for a metalloprotein complex exposed at room temperature to the high X-ray flux typical of third-generation synchrotron sources. Following the progression of the X-ray-induced damage by Mn Kβ X-ray emission spectroscopy, we demonstrated the feasibility of collecting room-temperature data on the electronic structure of native Photosystem II, a trans-membrane metalloprotein complex containing a Mn4Ca cluster. The determined nondamaging observation time frame (about 100 ms using a continuous monochromatic beam, with a deposited dose of 1 × 107 photons/μm2 or 1.3 × 104 Gy, and about 66 μs in pulsed mode using a pink beam, with a deposited dose of 4 × 107 photons/μm2 or 4.2 × 104 Gy) is sufficient for the analysis of this protein’s electron dynamics and catalytic mechanism at room-temperature. Reported time frames are expected to be representative for other metalloproteins. The described instrumentation, based on the short working distance dispersive spectrometer, and experimental methodology are broadly applicable to time-resolved X-ray emission analysis at synchrotron and X-ray free-electron laser light sources.
- 26 June 2012
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 3 (14) , 1858-1864
Fast Detection Allowing Analysis of Metalloprotein Electronic Structure by X-ray Emission Spectroscopy at Room Temperature
The paradigm of “detection-before-destruction” was tested for a metalloprotein complex exposed at room temperature to the high X-ray flux typical of third-generation synchrotron sources. Following the progression of the X-ray-induced damage by Mn Kβ X-ray emission spectroscopy, we demonstrated the feasibility of collecting room-temperature data on the electronic structure of native Photosystem II, a trans-membrane metalloprotein complex containing a Mn4Ca cluster. The determined nondamaging observation time frame (about 100 ms using a continuous monochromatic beam, with a deposited dose of 1 × 107 photons/μm2 or 1.3 × 104 Gy, and about 66 μs in pulsed mode using a pink beam, with a deposited dose of 4 × 107 photons/μm2 or 4.2 × 104 Gy) is sufficient for the analysis of this protein’s electron dynamics and catalytic mechanism at room-temperature. Reported time frames are expected to be representative for other metalloproteins. The described instrumentation, based on the short working distance dispersive spectrometer, and experimental methodology are broadly applicable to time-resolved X-ray emission analysis at synchrotron and X-ray free-electron laser light sources.
- 30 March 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 85 (10)
electron delocalization and volume collapse in praseodymium metalWe study the pressure evolution of the 4f electrons in elemental praseodymium metal compressed through several crystallographic phases, including the large volume-collapse transition at 20 GPa. Using resonant x-ray emission, we directly and quantitatively measure the development of multiple electronic configurations with differing 4f occupation numbers, the key quantum observable related to the delocalization of the strongly correlated 4f electrons. These results provide a high-fidelity test of prior predictions by dynamical mean-field theory, and support the hypothesis of a strong connection between electronic and structural degrees of freedom at the volume-collapse transition.
- 30 March 2012
- Published by American Physical Society (APS) in Physical Review B
- Vol. 85 (10)
electron delocalization and volume collapse in praseodymium metalWe study the pressure evolution of the 4f electrons in elemental praseodymium metal compressed through several crystallographic phases, including the large volume-collapse transition at 20 GPa. Using resonant x-ray emission, we directly and quantitatively measure the development of multiple electronic configurations with differing 4f occupation numbers, the key quantum observable related to the delocalization of the strongly correlated 4f electrons. These results provide a high-fidelity test of prior predictions by dynamical mean-field theory, and support the hypothesis of a strong connection between electronic and structural degrees of freedom at the volume-collapse transition.