David L. Halaney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David L. Halaney has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Thomas E. Milner
Laboratory of Guillermo Aguilar, Department of Mechanical Engineering, University of California, Riverside, Riverside, CA, United States
9 shared publications- Guillermo Aguilar
J. Mike Walker '66 Department of Mechanical Engineering Texas A&M University College Station TX 77840 USA
5 shared publications Marc D. Feldman
Division of Cardiology, University of Texas Health Science Center, 7703 Floyd Curl Drive, San Antonio, Texas
4 shared publications- Marc D. Feldman
Department of Biomedical Engineering, University of Texas at San Antonio, San Antonio, Texas, USA
4 shared publications Deborah Vela
Texas Heart Institute, Houston, Texas
3 shared publications- Nami Davoodzadeh
Univ. of California, Riverside
3 shared publications
Latest Publications
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-4
Variable Exposure Portable Perfusion Monitor Using Commercial Vision Processing System-on-Modules (SOMs)
Laser speckle imaging (LSI) has been widely used to image blood flow in biomedical/clinical research. Commercially available perfusion monitoring systems are bulky, expensive, and lack portability. Portable devices that perform LSI using custom digital signal processors (DSPs) and smartphones have been proposed to perform single-exposure LSI to monitor blood flow. While these can perform LSI, it is difficult to estimate flow rates using single exposure LSI. In this study, we use NVIDIA’s Xavier NX embedded vision processing platform to perform variable exposure LSI to evaluate flow rates in a 3-D printed flow phantom. A low-cost Raspberry Pi HQ camera was used to acquire LSI images and the increased sensitivity of the camera allowed images to be captured with exposure times 12 mm/s) flow rates were distinguished. Such a platform can extend the use of portable LSI devices in peri-operative, postoperative, and other point-of-care applications as this platform can be commercialized into a tablet-like form factor for convenient portable operation.
- 14 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-4
Variable Exposure Portable Perfusion Monitor Using Commercial Vision Processing System-on-Modules (SOMs)
Laser speckle imaging (LSI) has been widely used to image blood flow in biomedical/clinical research. Commercially available perfusion monitoring systems are bulky, expensive, and lack portability. Portable devices that perform LSI using custom digital signal processors (DSPs) and smartphones have been proposed to perform single-exposure LSI to monitor blood flow. While these can perform LSI, it is difficult to estimate flow rates using single exposure LSI. In this study, we use NVIDIA’s Xavier NX embedded vision processing platform to perform variable exposure LSI to evaluate flow rates in a 3-D printed flow phantom. A low-cost Raspberry Pi HQ camera was used to acquire LSI images and the increased sensitivity of the camera allowed images to be captured with exposure times 12 mm/s) flow rates were distinguished. Such a platform can extend the use of portable LSI devices in peri-operative, postoperative, and other point-of-care applications as this platform can be commercialized into a tablet-like form factor for convenient portable operation.
- 21 December 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. PM336, 357-406
Transparent Polycrystalline Ceramic Cranial Implant with Photonic Functionality in the SWIR
Short-wavelength infrared (SWIR)-based techniques for imaging, diagnosing, and treating the brain have become widespread clinical tools, but application of these techniques is limited by optical attenuation in the scalp and skull. In this chapter, we examine a strategy to provide optical access to the brain for SWIR delivery and collection. This strategy utilizes a transparent cranial implant termed the “window to the brain” (WttB); this implant is made from a tough, biocompatible, and transparent ceramic called nanocrystalline yttriastabilized zirconia (nc-YSZ). By pairing this cranial window with scalp optical clearing, light scattering by the skull and scalp can be mitigated, allowing for SWIR light delivery to and from the underlying brain tissue. Online access to SPIE eBooks is limited to subscribing institutions.
- 21 December 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. PM336, 357-406
Transparent Polycrystalline Ceramic Cranial Implant with Photonic Functionality in the SWIR
Short-wavelength infrared (SWIR)-based techniques for imaging, diagnosing, and treating the brain have become widespread clinical tools, but application of these techniques is limited by optical attenuation in the scalp and skull. In this chapter, we examine a strategy to provide optical access to the brain for SWIR delivery and collection. This strategy utilizes a transparent cranial implant termed the “window to the brain” (WttB); this implant is made from a tough, biocompatible, and transparent ceramic called nanocrystalline yttriastabilized zirconia (nc-YSZ). By pairing this cranial window with scalp optical clearing, light scattering by the skull and scalp can be mitigated, allowing for SWIR light delivery to and from the underlying brain tissue. Online access to SPIE eBooks is limited to subscribing institutions.
- Open Access
- 19 March 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Group Refractive Index of Nanocrystalline Yttria-Stabilized Zirconia Transparent Cranial Implants
Transparent “Window to the Brain” (WttB) cranial implants made from a biocompatible ceramic, nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), were recently reported. These reports demonstrated chronic brain imaging across the implants in mice using optical coherence tomography (OCT) and laser speckle imaging. However, optical properties of these transparent cranial implants are neither completely characterized nor completely understood. In this study, we measure optical properties of the implant using a swept source OCT system with a spectral range of 136 nm centered at 1,300 nm to characterize the group refractive index of the nc-YSZ window, over a narrow range of temperatures at which the implant may be used during imaging or therapy (20–43°C). Group refractive index was found to be 2.1–2.2 for OCT imaging over this temperature range. Chromatic dispersion for this spectral range was observed to vary over the sample, sometimes flipping signs between normal and anomalous dispersion. These properties of nc-YSZ should be considered when designing optical systems and procedures that propagate light through the window, and when interpreting OCT brain images acquired across the window.
- 19 March 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Open AccessGroup Refractive Index of Nanocrystalline Yttria-Stabilized Zirconia Transparent Cranial Implants
Transparent “Window to the Brain” (WttB) cranial implants made from a biocompatible ceramic, nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), were recently reported. These reports demonstrated chronic brain imaging across the implants in mice using optical coherence tomography (OCT) and laser speckle imaging. However, optical properties of these transparent cranial implants are neither completely characterized nor completely understood. In this study, we measure optical properties of the implant using a swept source OCT system with a spectral range of 136 nm centered at 1,300 nm to characterize the group refractive index of the nc-YSZ window, over a narrow range of temperatures at which the implant may be used during imaging or therapy (20–43°C). Group refractive index was found to be 2.1–2.2 for OCT imaging over this temperature range. Chromatic dispersion for this spectral range was observed to vary over the sample, sometimes flipping signs between normal and anomalous dispersion. These properties of nc-YSZ should be considered when designing optical systems and procedures that propagate light through the window, and when interpreting OCT brain images acquired across the window.
- Open Access
- 30 June 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8, 659
Chronic Brain Imaging Across a Transparent Nanocrystalline Yttria-Stabilized-Zirconia Cranial Implant
Repeated non-diffuse optical imaging of the brain is difficult. This is due to the fact that the cranial bone is highly scattering and thus a strong optical barrier. Repeated craniotomies increase the risk of complications and may disrupt the biological systems being imaged. We previously introduced a potential solution in the form of a transparent ceramic cranial implant called the Window to the Brain (WttB) implant. This implant is made of nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), which possesses the requisite mechanical strength to serve as a permanent optical access window in human patients. In this present study, we demonstrate repeated brain imaging of n = 5 mice using both OCT and LSI across the WttB implant over 4 weeks. The main objectives are to determine if the WttB implant allows for chronic OCT imaging, and to shed further light on the question of whether optical access provided by the WttB implant remains stable over this duration in the body. The Window to the Brain implant allowed for stable repeated imaging of the mouse brain with Optical Coherence Tomography over 28 days, without loss of signal intensity. Repeated Laser Speckle Imaging was also possible over this timeframe, but signal to noise ratio and the sharpness of vessels in the images decreased with time. This can be partially explained by elevated blood flow during the first imaging session in response to trauma from the surgery, which was also detected by OCT flow imaging. These results are promising for long-term optical access through the WttB implant, making feasible chronic in vivo studies in multiple neurological models of brain disease.
- 30 June 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8, 659
Open AccessChronic Brain Imaging Across a Transparent Nanocrystalline Yttria-Stabilized-Zirconia Cranial Implant
Repeated non-diffuse optical imaging of the brain is difficult. This is due to the fact that the cranial bone is highly scattering and thus a strong optical barrier. Repeated craniotomies increase the risk of complications and may disrupt the biological systems being imaged. We previously introduced a potential solution in the form of a transparent ceramic cranial implant called the Window to the Brain (WttB) implant. This implant is made of nanocrystalline Yttria-Stabilized Zirconia (nc-YSZ), which possesses the requisite mechanical strength to serve as a permanent optical access window in human patients. In this present study, we demonstrate repeated brain imaging of n = 5 mice using both OCT and LSI across the WttB implant over 4 weeks. The main objectives are to determine if the WttB implant allows for chronic OCT imaging, and to shed further light on the question of whether optical access provided by the WttB implant remains stable over this duration in the body. The Window to the Brain implant allowed for stable repeated imaging of the mouse brain with Optical Coherence Tomography over 28 days, without loss of signal intensity. Repeated Laser Speckle Imaging was also possible over this timeframe, but signal to noise ratio and the sharpness of vessels in the images decreased with time. This can be partially explained by elevated blood flow during the first imaging session in response to trauma from the surgery, which was also detected by OCT flow imaging. These results are promising for long-term optical access through the WttB implant, making feasible chronic in vivo studies in multiple neurological models of brain disease.
- Open Access
Theranostic cranial implant for hyperspectral light delivery and microcirculation imaging without scalp removal
Light based techniques for imaging, diagnosing and treating the brain have become widespread clinical tools, but application of these techniques is limited by optical attenuation in the scalp and skull. This optical attenuation reduces the achievable spatial resolution, precluding the visualization of small features such as brain microvessels. The goal of this study was to assess a strategy for providing ongoing optical access to the brain without the need for repeated craniectomy or retraction of the scalp. This strategy involves the use of a transparent cranial implant and skin optical clearing agents, and was tested in mice to assess improvements in optical access which could be achieved for laser speckle imaging of cerebral microvasculature. Combined transmittance of the optically cleared scalp overlying the transparent cranial implant was as high as 89% in the NIR range, 50% in red range, 24% in green range, and 20% in blue range. In vivo laser speckle imaging experiments of mouse cerebral blood vessels showed that the proposed optical access increased signal-to-noise ratio and image resolution, allowing for visualization of microvessels through the transparent implant, which was not possible through the uncleared scalp and intact skull.
Open AccessTheranostic cranial implant for hyperspectral light delivery and microcirculation imaging without scalp removal
Light based techniques for imaging, diagnosing and treating the brain have become widespread clinical tools, but application of these techniques is limited by optical attenuation in the scalp and skull. This optical attenuation reduces the achievable spatial resolution, precluding the visualization of small features such as brain microvessels. The goal of this study was to assess a strategy for providing ongoing optical access to the brain without the need for repeated craniectomy or retraction of the scalp. This strategy involves the use of a transparent cranial implant and skin optical clearing agents, and was tested in mice to assess improvements in optical access which could be achieved for laser speckle imaging of cerebral microvasculature. Combined transmittance of the optically cleared scalp overlying the transparent cranial implant was as high as 89% in the NIR range, 50% in red range, 24% in green range, and 20% in blue range. In vivo laser speckle imaging experiments of mouse cerebral blood vessels showed that the proposed optical access increased signal-to-noise ratio and image resolution, allowing for visualization of microvessels through the transparent implant, which was not possible through the uncleared scalp and intact skull.
- 8 July 2016
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 48 (8) , 782-789
Evaluation of laser bacterial anti‐fouling of transparent nanocrystalline yttria‐stabilized‐zirconia cranial implant
Background and Objective: The development and feasibility of a novel nanocrystalline yttria‐stabilized‐zirconia (nc‐YSZ) cranial implant has been recently established. The purpose of what we now call “window to the brain (WttB)” implant (or platform), is to improve patient care by providing a technique for delivery and/or collection of light into/from the brain, on demand, over large areas, and on a chronically recurring basis without the need for repeated craniotomies. WttB holds the transformative potential for enhancing light‐based diagnosis and treatment of a wide variety of brain pathologies including cerebral edema, traumatic brain injury, stroke, glioma, and neurodegenerative diseases. However, bacterial adhesion to the cranial implant is the leading factor for biofilm formation (fouling), infection, and treatment failure. Escherichia coli (E. coli), in particular, is the most common isolate in gram‐negative bacillary meningitis after cranial surgery or trauma. The transparency of our WttB implant may provide a unique opportunity for non‐invasive treatment of bacterial infection under the implant using medical lasers.Study Design/Materials and Methods: A drop of a diluted overnight culture of BL21‐293 E. coli expressing luciferase was seeded between the nc‐YSZ implant and the agar plate. This was followed by immediate irradiation with selected laser. After each laser treatment the nc‐YSZ was removed, and cultures were incubated for 24 hours at 37 °C. The study examined continuous wave (CW) and pulsed wave (PW) modes of near‐infrared (NIR) 810 nm laser wavelength with a power output ranging from 1 to 3 W. During irradiation, the temperature distribution of nc‐YSZ surface was monitored using an infrared thermal camera. Relative luminescence unit (RLU) was used to evaluate the viability of bacteria after the NIR laser treatment.Results: Analysis of RLU suggests that the viability of E. coli biofilm formation was reduced with NIR laser treatment when compared to the control group (P < 0.01) and loss of viability depends on both laser fluence and operation mode (CW or PW). The results demonstrate that while CW laser reduces the biofilm formation more than PW laser with the same power, the higher surface temperature of the implant generated by CW laser limits its medical efficacy. In contrast, with the right parameters, PW laser produces a more moderate photothermal effect which can be equally effective at controlling bacterial growth.Conclusions: Our results show that E. coli biofilm formation across the thickness of the nc‐YSZ implant can be disrupted using NIR laser treatment. The results of this in vitro study suggest that using nc‐YSZ as a cranial implant in vivo may also allow for locally selective, non‐invasive, chronic treatment of bacterial layers (fouling) that might form under cranial implants, without causing adverse thermal damage to the underlying host tissue when appropriate laser parameters are used. Lasers Surg. Med. 48:782–789, 2016.
- 8 July 2016
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 48 (8) , 782-789
Evaluation of laser bacterial anti‐fouling of transparent nanocrystalline yttria‐stabilized‐zirconia cranial implant
Background and Objective: The development and feasibility of a novel nanocrystalline yttria‐stabilized‐zirconia (nc‐YSZ) cranial implant has been recently established. The purpose of what we now call “window to the brain (WttB)” implant (or platform), is to improve patient care by providing a technique for delivery and/or collection of light into/from the brain, on demand, over large areas, and on a chronically recurring basis without the need for repeated craniotomies. WttB holds the transformative potential for enhancing light‐based diagnosis and treatment of a wide variety of brain pathologies including cerebral edema, traumatic brain injury, stroke, glioma, and neurodegenerative diseases. However, bacterial adhesion to the cranial implant is the leading factor for biofilm formation (fouling), infection, and treatment failure. Escherichia coli (E. coli), in particular, is the most common isolate in gram‐negative bacillary meningitis after cranial surgery or trauma. The transparency of our WttB implant may provide a unique opportunity for non‐invasive treatment of bacterial infection under the implant using medical lasers.Study Design/Materials and Methods: A drop of a diluted overnight culture of BL21‐293 E. coli expressing luciferase was seeded between the nc‐YSZ implant and the agar plate. This was followed by immediate irradiation with selected laser. After each laser treatment the nc‐YSZ was removed, and cultures were incubated for 24 hours at 37 °C. The study examined continuous wave (CW) and pulsed wave (PW) modes of near‐infrared (NIR) 810 nm laser wavelength with a power output ranging from 1 to 3 W. During irradiation, the temperature distribution of nc‐YSZ surface was monitored using an infrared thermal camera. Relative luminescence unit (RLU) was used to evaluate the viability of bacteria after the NIR laser treatment.Results: Analysis of RLU suggests that the viability of E. coli biofilm formation was reduced with NIR laser treatment when compared to the control group (P < 0.01) and loss of viability depends on both laser fluence and operation mode (CW or PW). The results demonstrate that while CW laser reduces the biofilm formation more than PW laser with the same power, the higher surface temperature of the implant generated by CW laser limits its medical efficacy. In contrast, with the right parameters, PW laser produces a more moderate photothermal effect which can be equally effective at controlling bacterial growth.Conclusions: Our results show that E. coli biofilm formation across the thickness of the nc‐YSZ implant can be disrupted using NIR laser treatment. The results of this in vitro study suggest that using nc‐YSZ as a cranial implant in vivo may also allow for locally selective, non‐invasive, chronic treatment of bacterial layers (fouling) that might form under cranial implants, without causing adverse thermal damage to the underlying host tissue when appropriate laser parameters are used. Lasers Surg. Med. 48:782–789, 2016.
- Open Access
- 1 November 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (11) , 115002
Differences in forward angular light scattering distributions between M1 and M2 macrophages
The ability to distinguish macrophage subtypes noninvasively could have diagnostic potential in cancer, atherosclerosis, and diabetes, where polarized M1 and M2 macrophages play critical and often opposing roles. Current methods to distinguish macrophage subtypes rely on tissue biopsy. Optical imaging techniques based on light scattering are of interest as they can be translated into biopsy-free strategies. Because mitochondria are relatively strong subcellular light scattering centers, and M2 macrophages are known to have enhanced mitochondrial biogenesis compared to M1, we hypothesized that M1 and M2 macrophages may have different angular light scattering profiles. To test this, we developed an in vitro angle-resolved forward light scattering measurement system. We found that M1 and M2 macrophage monolayers scatter relatively unequal amounts of light in the forward direction between 1.6 deg and 3.2 deg with M2 forward scattering significantly more light than M1 at increasing angles. The ratio of forward scattering can be used to identify the polarization state of macrophage populations in culture.
- 1 November 2015
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 20 (11) , 115002
Open AccessDifferences in forward angular light scattering distributions between M1 and M2 macrophages
The ability to distinguish macrophage subtypes noninvasively could have diagnostic potential in cancer, atherosclerosis, and diabetes, where polarized M1 and M2 macrophages play critical and often opposing roles. Current methods to distinguish macrophage subtypes rely on tissue biopsy. Optical imaging techniques based on light scattering are of interest as they can be translated into biopsy-free strategies. Because mitochondria are relatively strong subcellular light scattering centers, and M2 macrophages are known to have enhanced mitochondrial biogenesis compared to M1, we hypothesized that M1 and M2 macrophages may have different angular light scattering profiles. To test this, we developed an in vitro angle-resolved forward light scattering measurement system. We found that M1 and M2 macrophage monolayers scatter relatively unequal amounts of light in the forward direction between 1.6 deg and 3.2 deg with M2 forward scattering significantly more light than M1 at increasing angles. The ratio of forward scattering can be used to identify the polarization state of macrophage populations in culture.
- 27 May 2015
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 47 (6) , 485-494
Detection of plaque structure and composition using OCT combined with two‐photon luminescence (TPL) imaging
Background and Objectives: Atherosclerosis and plaque rupture leads to myocardial infarction and stroke. A novel hybrid optical coherence tomography (OCT) and two‐photon luminescence (TPL) fiber‐based imaging system was developed to characterize tissue constituents in the context of plaque morphology.Study Design/Materials and Methods: Ex vivo coronary arteries (34 regions of interest) from three human hearts with atherosclerotic plaques were examined by OCT–TPL imaging. Histological sections (4 μm in thickness) were stained with Oil Red O for lipid, Von Kossa for calcium, and Verhoeff–Masson Tri‐Elastic for collagen/elastin fibers and compared with imaging results.Results: Biochemical components in plaques including lipid, oxidized‐LDL, and calcium, as well as a non‐tissue component (metal) are distinguished by multi‐channel TPL images with statistical significance (P < 0.001). TPL imaging provides complementary optical contrast to OCT (two‐photon absorption/emission vs scattering). Merged OCT–TPL images demonstrate the distribution of lipid deposits in registration with detailed plaque surface profile.Conclusions: Results suggest that multi‐channel TPL imaging can effectively identify lipid sub‐types and different plaque components. Furthermore, fiber‐based hybrid OCT–TPL imaging simultaneously detects plaque structure and composition, improving the efficacy of vulnerable plaque detection and characterization. Lasers Surg. Med. 47:485–494, 2015.
- 27 May 2015
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 47 (6) , 485-494
Detection of plaque structure and composition using OCT combined with two‐photon luminescence (TPL) imaging
Background and Objectives: Atherosclerosis and plaque rupture leads to myocardial infarction and stroke. A novel hybrid optical coherence tomography (OCT) and two‐photon luminescence (TPL) fiber‐based imaging system was developed to characterize tissue constituents in the context of plaque morphology.Study Design/Materials and Methods: Ex vivo coronary arteries (34 regions of interest) from three human hearts with atherosclerotic plaques were examined by OCT–TPL imaging. Histological sections (4 μm in thickness) were stained with Oil Red O for lipid, Von Kossa for calcium, and Verhoeff–Masson Tri‐Elastic for collagen/elastin fibers and compared with imaging results.Results: Biochemical components in plaques including lipid, oxidized‐LDL, and calcium, as well as a non‐tissue component (metal) are distinguished by multi‐channel TPL images with statistical significance (P < 0.001). TPL imaging provides complementary optical contrast to OCT (two‐photon absorption/emission vs scattering). Merged OCT–TPL images demonstrate the distribution of lipid deposits in registration with detailed plaque surface profile.Conclusions: Results suggest that multi‐channel TPL imaging can effectively identify lipid sub‐types and different plaque components. Furthermore, fiber‐based hybrid OCT–TPL imaging simultaneously detects plaque structure and composition, improving the efficacy of vulnerable plaque detection and characterization. Lasers Surg. Med. 47:485–494, 2015.
- Open Access
- 10 April 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (5) , 1665-1678
Dual-modality fiber-based OCT-TPL imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques
New optical imaging techniques that provide contrast to study both the anatomy and composition of atherosclerotic plaques can be utilized to better understand the formation, progression and clinical complications of human coronary artery disease. We present a dual-modality fiber-based optical imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques that combines optical coherence tomography (OCT) and two-photon luminescence (TPL) imaging. Experimental results from ex vivo human coronary arteries show that OCT and TPL optical contrast in recorded OCT-TPL images is complimentary and in agreement with histological analysis. Molecular composition (e.g., lipid and oxidized-LDL) detected by TPL imaging can be overlaid onto plaque microstructure depicted by OCT, providing new opportunities for atherosclerotic plaque identification and characterization.
- 10 April 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (5) , 1665-1678
Open AccessDual-modality fiber-based OCT-TPL imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques
New optical imaging techniques that provide contrast to study both the anatomy and composition of atherosclerotic plaques can be utilized to better understand the formation, progression and clinical complications of human coronary artery disease. We present a dual-modality fiber-based optical imaging system for simultaneous microstructural and molecular analysis of atherosclerotic plaques that combines optical coherence tomography (OCT) and two-photon luminescence (TPL) imaging. Experimental results from ex vivo human coronary arteries show that OCT and TPL optical contrast in recorded OCT-TPL images is complimentary and in agreement with histological analysis. Molecular composition (e.g., lipid and oxidized-LDL) detected by TPL imaging can be overlaid onto plaque microstructure depicted by OCT, providing new opportunities for atherosclerotic plaque identification and characterization.