Jose Ponte
Research Subjects
Research Interests
Jose Ponte has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
M J Purves
9 shared publicationsJ Moxham
6 shared publications- Michael Simon Avidan
From the Department of Anesthesiology, Washington University School of Medicine, St. Louis, Missouri
5 shared publications M. J. Purves
University of Bristol
3 shared publicationsC L Sadler
Department of Anaesthetics, King's College School of Medicine and Dentistry, Denmark Hill, London
2 shared publicationsC Lanigan
Department of Anaesthesia, King's College Hospital, London
2 shared publications
Latest Publications
- Open Access
- 1 November 2008
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 101 (5) , 738-740
Memory and awareness during anaesthesia
Editor—I could not help noticing that not a single word can be found about the role of neuromuscular blockers in awareness under anaesthesia in either the editorial1 or in the abstracts of the 7th International Symposium on Memory and Awareness in Anaesthesia published in the June issue of the journal.2 Predictably, little progress has been made in the last 10 yr in tackling the problem of awareness under anaesthesia and skeletal muscle movement continues to be the ‘gold standard’ for detection of this embarrassing complication. However, it is apparent from what appears in the literature that the opinion formers and possibly those providing the specialist training have largely ignored many attempts, including mine in 1995,3 to alert the profession for the misuse of neuromuscular blockers. Perhaps, there is a positive side to the persistence in practice of this avoidable complication: it provides a powerful stimulus for the research into the mechanisms of anaesthesia and memory formation.
- 1 November 2008
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 101 (5) , 738-740
Open AccessMemory and awareness during anaesthesia
Editor—I could not help noticing that not a single word can be found about the role of neuromuscular blockers in awareness under anaesthesia in either the editorial1 or in the abstracts of the 7th International Symposium on Memory and Awareness in Anaesthesia published in the June issue of the journal.2 Predictably, little progress has been made in the last 10 yr in tackling the problem of awareness under anaesthesia and skeletal muscle movement continues to be the ‘gold standard’ for detection of this embarrassing complication. However, it is apparent from what appears in the literature that the opinion formers and possibly those providing the specialist training have largely ignored many attempts, including mine in 1995,3 to alert the profession for the misuse of neuromuscular blockers. Perhaps, there is a positive side to the persistence in practice of this avoidable complication: it provides a powerful stimulus for the research into the mechanisms of anaesthesia and memory formation.
- 1 February 2005
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 79 (2) , 696-698
Off-Pump Coronary Artery Bypass Grafting in a Heparin-Induced Thrombocytopenia Type II Patient Using Hirudin
- 1 February 2005
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 79 (2) , 696-698
Off-Pump Coronary Artery Bypass Grafting in a Heparin-Induced Thrombocytopenia Type II Patient Using Hirudin
- Top Cited Papers
- 1 February 2004
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 92 (2) , 178-186
Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery
Using algorithms based on point of care coagulation tests can decrease blood loss and blood component transfusion after cardiac surgery. We wished to test the hypothesis that a management algorithm based on near-patient tests would reduce blood loss and blood component use after routine coronary artery surgery with cardiopulmonary bypass when compared with an algorithm based on routine laboratory assays or with clinical judgement. Patients (n=102) undergoing elective coronary artery surgery with cardiac bypass were randomized into two groups. In the point of care group, the management algorithm was based on information provided by three devices, the Hepcon, thromboelastography and the PFA-100 platelet function analyser. Management in the laboratory test group depended on rapidly available laboratory clotting tests and transfusion of haemostatic blood components only if specific criteria were met. Blood loss and transfusion was compared between these two groups and with a retrospective case-control group (n=108), in which management of bleeding had been according to the clinician's discretion. All three groups had similar median blood losses. The transfusion of packed red blood cells (PRBCs) and blood components was greater in the clinician discretion group (P<0.05) but there was no difference in the transfusion of PRBCs and blood components between the two algorithm-guided groups. Following algorithms based on point of care tests or on structured clinical practice with standard laboratory tests does not decrease blood loss, but reduces the transfusion of PRBCs and blood components after routine cardiac surgery, when compared with clinician discretion. Cardiac surgery services should use transfusion guidelines based on laboratory-guided algorithms, and the possible benefits of point of care testing should be tested against this standard.
- 1 February 2004
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 92 (2) , 178-186
Top Cited PapersComparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery
Using algorithms based on point of care coagulation tests can decrease blood loss and blood component transfusion after cardiac surgery. We wished to test the hypothesis that a management algorithm based on near-patient tests would reduce blood loss and blood component use after routine coronary artery surgery with cardiopulmonary bypass when compared with an algorithm based on routine laboratory assays or with clinical judgement. Patients (n=102) undergoing elective coronary artery surgery with cardiac bypass were randomized into two groups. In the point of care group, the management algorithm was based on information provided by three devices, the Hepcon, thromboelastography and the PFA-100 platelet function analyser. Management in the laboratory test group depended on rapidly available laboratory clotting tests and transfusion of haemostatic blood components only if specific criteria were met. Blood loss and transfusion was compared between these two groups and with a retrospective case-control group (n=108), in which management of bleeding had been according to the clinician's discretion. All three groups had similar median blood losses. The transfusion of packed red blood cells (PRBCs) and blood components was greater in the clinician discretion group (P<0.05) but there was no difference in the transfusion of PRBCs and blood components between the two algorithm-guided groups. Following algorithms based on point of care tests or on structured clinical practice with standard laboratory tests does not decrease blood loss, but reduces the transfusion of PRBCs and blood components after routine cardiac surgery, when compared with clinician discretion. Cardiac surgery services should use transfusion guidelines based on laboratory-guided algorithms, and the possible benefits of point of care testing should be tested against this standard.
- 1 April 2002
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 88 (4) , 489-495
Glucose, insulin and potassium for heart protection during cardiac surgery
Coronary artery bypass grafting with hypothermic cardiac arrest and cardiopulmonary bypass (CPB) is associated with myocardial injury. Our study investigated whether an infusion of glucose, insulin and potassium (GIK) during elective coronary artery bypass surgery decreases myocardial cell death. We measured cardiac troponin I (cTnI), a myofibrillar structural protein, which is a sensitive and specific indicator of myocytic injury. With ethics committee approval, 42 patients were enrolled into a randomized, prospective, double-blinded study. In the GIK group, 500 ml of 50% dextrose solution containing 100 IU insulin and potassium 80 mmol was infused at the rate of 0.75 ml kg(-1) h(-1). Patients in the non-GIK group received 5% dextrose solution at the same rate. Arterial blood samples were taken before induction of anaesthesia, after removal of the aortic clamp and 6 and 12 h after CPB. In both groups there was an increase in cTnI concentration (P<0.05), which was greatest about 6 h after CPB. At no time did the cTnI concentration differ between the two groups. The results suggest that GIK does not decrease the irreversible myocardial damage associated with routine coronary artery bypass surgery.
- 1 April 2002
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 88 (4) , 489-495
Glucose, insulin and potassium for heart protection during cardiac surgery
Coronary artery bypass grafting with hypothermic cardiac arrest and cardiopulmonary bypass (CPB) is associated with myocardial injury. Our study investigated whether an infusion of glucose, insulin and potassium (GIK) during elective coronary artery bypass surgery decreases myocardial cell death. We measured cardiac troponin I (cTnI), a myofibrillar structural protein, which is a sensitive and specific indicator of myocytic injury. With ethics committee approval, 42 patients were enrolled into a randomized, prospective, double-blinded study. In the GIK group, 500 ml of 50% dextrose solution containing 100 IU insulin and potassium 80 mmol was infused at the rate of 0.75 ml kg(-1) h(-1). Patients in the non-GIK group received 5% dextrose solution at the same rate. Arterial blood samples were taken before induction of anaesthesia, after removal of the aortic clamp and 6 and 12 h after CPB. In both groups there was an increase in cTnI concentration (P<0.05), which was greatest about 6 h after CPB. At no time did the cTnI concentration differ between the two groups. The results suggest that GIK does not decrease the irreversible myocardial damage associated with routine coronary artery bypass surgery.
- 1 December 2001
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 87 (6) , 876-884
Tracheal tube pressure change during magnetic stimulation of the phrenic nerves as an indicator of diaphragm strength on the intensive care unit
Diaphragm strength can be assessed from twitch gastric (TwPgas), twitch oesophageal (TwPoes), and twitch transdiaphragmatic pressure (TwPdi) in response to phrenic nerve stimulation. This requires the passage of balloon catheters, which may be difficult. Changes in pressure measured at the mouth during phrenic nerve stimulation avoid the need for balloon catheters. We hypothesized that pressures measured at the tracheal tube during phrenic stimulation, could also reflect oesophageal pressure change as a result of isolated diaphragmatic contraction and, therefore, reflect diaphragm strength. We aimed to establish the relationship between twitch tracheal tube pressure (TwPet), TwPoes, and TwPdi in patients in the supine and sitting positions. The phrenic nerves were stimulated magnetically bilaterally, in 14 ICU patients while supine and on another occasion while sitting up at 45 degrees. In the sitting position mean TwPoes was 9.1 cm H2O and TwPet 11.3 cm H2O (mean(SD) difference -2.2 (SD 1.5)). In the supine position mean TwPoes was 8.1 cm H2O and TwPet 9.9 cm H2O (mean difference -1.8 (2.2)). The difference between TwPoes and TwPet was less at low twitch amplitude; less than +/- 1 cm H2O below a mean twitch height of 8 cm H2O supine and 10 cm H2O sitting. Sitting TwPet was related to TwPoes r2=0.93 and TwPdi r2=0.65 (P<0.01). Supine TwPet was related to TwPoes r2=0.84 and TwPdi r2=0.83 (P<0.01). The mean within occasion coefficient of variation while sitting was TwPet=13.3%, TwPoes=13.9%, TwPdi=11.2%, and supine TwPet=11.6%, TwPoes=14.6%, TwPdi=11.8%. We conclude that TwPet reflects TwPoes during diaphragmatic stimulation and is worthy of further study to establish its place as a guide to the presence of respiratory muscle strength and fatigue.
- 1 December 2001
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 87 (6) , 876-884
Tracheal tube pressure change during magnetic stimulation of the phrenic nerves as an indicator of diaphragm strength on the intensive care unit
Diaphragm strength can be assessed from twitch gastric (TwPgas), twitch oesophageal (TwPoes), and twitch transdiaphragmatic pressure (TwPdi) in response to phrenic nerve stimulation. This requires the passage of balloon catheters, which may be difficult. Changes in pressure measured at the mouth during phrenic nerve stimulation avoid the need for balloon catheters. We hypothesized that pressures measured at the tracheal tube during phrenic stimulation, could also reflect oesophageal pressure change as a result of isolated diaphragmatic contraction and, therefore, reflect diaphragm strength. We aimed to establish the relationship between twitch tracheal tube pressure (TwPet), TwPoes, and TwPdi in patients in the supine and sitting positions. The phrenic nerves were stimulated magnetically bilaterally, in 14 ICU patients while supine and on another occasion while sitting up at 45 degrees. In the sitting position mean TwPoes was 9.1 cm H2O and TwPet 11.3 cm H2O (mean(SD) difference -2.2 (SD 1.5)). In the supine position mean TwPoes was 8.1 cm H2O and TwPet 9.9 cm H2O (mean difference -1.8 (2.2)). The difference between TwPoes and TwPet was less at low twitch amplitude; less than +/- 1 cm H2O below a mean twitch height of 8 cm H2O supine and 10 cm H2O sitting. Sitting TwPet was related to TwPoes r2=0.93 and TwPdi r2=0.65 (P<0.01). Supine TwPet was related to TwPoes r2=0.84 and TwPdi r2=0.83 (P<0.01). The mean within occasion coefficient of variation while sitting was TwPet=13.3%, TwPoes=13.9%, TwPdi=11.2%, and supine TwPet=11.6%, TwPoes=14.6%, TwPdi=11.8%. We conclude that TwPet reflects TwPoes during diaphragmatic stimulation and is worthy of further study to establish its place as a guide to the presence of respiratory muscle strength and fatigue.
- 1 December 2001
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 164 (11) , 2092-2097
Noninvasive Ventilator Triggering in Chronic Obstructive Pulmonary Disease
To be most effective, noninvasive ventilation (NIV) ventilators should synchronize well with patients' breathing. However, the speed with which different ventilators can respond to the transitions between inspiration and expiration may vary, and abnormal respiratory mechanics and mask leaks may exacerbate this problem. This study explored synchronization using a new test lung model designed to simulate acute exacerbations of chronic obstructive pulmonary disease (COPD). Thirteen ventilators were tested against different combinations of tidal volume (Vt), airways resistance (Raw), FRC, and mask leak. These combinations ranged from those of a severe exacerbation of COPD, to a mild condition reflecting the optimal triggering conditions a ventilator is likely to encounter. The triggering delays from the beginning and end of “inspiration” of the test lung, to the appropriate responses from the ventilators were measured. Three of the ventilators had trigger delays less than approximately 120 ms at both the beginning and end of expiration under all conditions. Trigger delays of other ventilators were mainly in the range of 120 to 300 ms, although exceptionally as long as 500 ms. Varying the conditions had a variable but generally small effect on triggering times, suggesting that there is a largely unavoidable element to the triggering delays intrinsic to the design of the ventilators.
- 1 December 2001
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 164 (11) , 2092-2097
Noninvasive Ventilator Triggering in Chronic Obstructive Pulmonary Disease
To be most effective, noninvasive ventilation (NIV) ventilators should synchronize well with patients' breathing. However, the speed with which different ventilators can respond to the transitions between inspiration and expiration may vary, and abnormal respiratory mechanics and mask leaks may exacerbate this problem. This study explored synchronization using a new test lung model designed to simulate acute exacerbations of chronic obstructive pulmonary disease (COPD). Thirteen ventilators were tested against different combinations of tidal volume (Vt), airways resistance (Raw), FRC, and mask leak. These combinations ranged from those of a severe exacerbation of COPD, to a mild condition reflecting the optimal triggering conditions a ventilator is likely to encounter. The triggering delays from the beginning and end of “inspiration” of the test lung, to the appropriate responses from the ventilators were measured. Three of the ventilators had trigger delays less than approximately 120 ms at both the beginning and end of expiration under all conditions. Trigger delays of other ventilators were mainly in the range of 120 to 300 ms, although exceptionally as long as 500 ms. Varying the conditions had a variable but generally small effect on triggering times, suggesting that there is a largely unavoidable element to the triggering delays intrinsic to the design of the ventilators.
- 1 November 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 95 (5) , 1169-1174
The Effects of Aprotinin on Thromboelastography with Three Different Activators
Background: Thromboelastography is used for assessment of hemostasis. Adherence to thromboelastography-guided algorithms and aprotinin administration each decrease bleeding and blood product usage after cardiac surgery. Aprotinin, through inhibition of kallikrein, causes prolongation of the celite-activated clotting time and the activated partial thromboplastin ratio. The aim of this study was to assess the effects of aprotinin on the thromboelastography trace. Methods: Three activators were used in the thromboelastography: celite (which is widely established), kaolin, and tissue factor. Assessment was performed on blood from volunteers and from patients before and after cardiac surgery. Results: The tissue factor-activated thromboelastography trace was unaffected by the addition of aprotinin. When celite and kaolin were used as activators in the presence of aprotinin, the reaction time (time to clot formation) of the thromboelastography trace was prolonged (P < 0.0001) and the maximum amplitude (clot strength) was decreased (P < 0.05). With celite as an activator, the addition of aprotinin decreased (P < 0.05) the thromboelastography alpha angle (rate of clot extension). The reaction time of the celite-activated trace correlated with the activated partial thromboplastin ratio (P < 0.01). The reaction time of the tissue factor-activated trace correlated with the international normalized ratio (P < 0.01). Conclusion: The thromboelastography trace is altered in the presence of aprotinin when celite and kaolin are used as activators but not when tissue factor is the activator.
- 1 November 2001
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 95 (5) , 1169-1174
The Effects of Aprotinin on Thromboelastography with Three Different Activators
Background: Thromboelastography is used for assessment of hemostasis. Adherence to thromboelastography-guided algorithms and aprotinin administration each decrease bleeding and blood product usage after cardiac surgery. Aprotinin, through inhibition of kallikrein, causes prolongation of the celite-activated clotting time and the activated partial thromboplastin ratio. The aim of this study was to assess the effects of aprotinin on the thromboelastography trace. Methods: Three activators were used in the thromboelastography: celite (which is widely established), kaolin, and tissue factor. Assessment was performed on blood from volunteers and from patients before and after cardiac surgery. Results: The tissue factor-activated thromboelastography trace was unaffected by the addition of aprotinin. When celite and kaolin were used as activators in the presence of aprotinin, the reaction time (time to clot formation) of the thromboelastography trace was prolonged (P < 0.0001) and the maximum amplitude (clot strength) was decreased (P < 0.05). With celite as an activator, the addition of aprotinin decreased (P < 0.05) the thromboelastography alpha angle (rate of clot extension). The reaction time of the celite-activated trace correlated with the activated partial thromboplastin ratio (P < 0.01). The reaction time of the tissue factor-activated trace correlated with the international normalized ratio (P < 0.01). Conclusion: The thromboelastography trace is altered in the presence of aprotinin when celite and kaolin are used as activators but not when tissue factor is the activator.
- 1 October 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (4) , 1081-2
Neuromuscular Blockers and Awareness
- 1 October 2001
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 93 (4) , 1081-2
Neuromuscular Blockers and Awareness
- 1 January 2001
- Published by Elsevier in Clinica Chimica Acta
- Vol. 303 (1-2) , 127-132
Changes in brain natriuretic peptide concentrations following open cardiac surgery with cardioplegic cardiac arrest
- 1 January 2001
- Published by Elsevier in Clinica Chimica Acta
- Vol. 303 (1-2) , 127-132
Changes in brain natriuretic peptide concentrations following open cardiac surgery with cardioplegic cardiac arrest
- 1 August 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (2) , 480-485
Isoflurane Does Not Depress the Hypoxic Response of Rabbit Carotid Body Chemoreceptors
Whether volatile anesthetics have an effect on the peripheral chemoreceptors is controversial, possibly because of differences in end-tidal CO2 concentrations. We studied the effect of isoflurane on the hypoxic chemosensitivity of carotid body chemoreceptors at three different Paco2 levels before and during the administration of 1.0% isoflurane (0.5 minimum alveolar anesthetic concentration) in six normothermic New Zealand white rabbits anesthetized with thiopental. The response of the chemoreceptors was fitted to the equation:Frequency (Hz) = a + b ×Paco2+ c ×(1/Pao2) + d ×(1/Pao2)2. Mean values for the coefficients a, b, c and d for the control state were −4.5, 0.13, 771, and 6332, respectively. This relationship was not changed by addition of isoflurane at 1.0% end-tidal concentration (P = 0.40, analysis of variance). We conclude that isoflurane at 1.0% end-tidal concentration does not depress the hypoxic response of rabbit carotid body chemoreceptors during either hypo-, normo-, or hypercapnia. Implications By measuring single-fiber chemoreceptor activity in anesthetized rabbits, we showed that isoflurane at 1.0% end-tidal concentration does not depress the hypoxic chemosensitivity of peripheral chemoreceptors during either hypo-, normo-, or hypercapnia in this species.
- 1 August 2000
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 91 (2) , 480-485
Isoflurane Does Not Depress the Hypoxic Response of Rabbit Carotid Body Chemoreceptors
Whether volatile anesthetics have an effect on the peripheral chemoreceptors is controversial, possibly because of differences in end-tidal CO2 concentrations. We studied the effect of isoflurane on the hypoxic chemosensitivity of carotid body chemoreceptors at three different Paco2 levels before and during the administration of 1.0% isoflurane (0.5 minimum alveolar anesthetic concentration) in six normothermic New Zealand white rabbits anesthetized with thiopental. The response of the chemoreceptors was fitted to the equation:Frequency (Hz) = a + b ×Paco2+ c ×(1/Pao2) + d ×(1/Pao2)2. Mean values for the coefficients a, b, c and d for the control state were −4.5, 0.13, 771, and 6332, respectively. This relationship was not changed by addition of isoflurane at 1.0% end-tidal concentration (P = 0.40, analysis of variance). We conclude that isoflurane at 1.0% end-tidal concentration does not depress the hypoxic response of rabbit carotid body chemoreceptors during either hypo-, normo-, or hypercapnia. Implications By measuring single-fiber chemoreceptor activity in anesthetized rabbits, we showed that isoflurane at 1.0% end-tidal concentration does not depress the hypoxic chemosensitivity of peripheral chemoreceptors during either hypo-, normo-, or hypercapnia in this species.