Christopher John Davey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christopher John Davey has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ewan James McAdam
Cranfield Water Science Institute, Cranfield University, MK43 0AL, UK
11 shared publications S. Tyrrel
Cranfield Water Science Institute, Cranfield University, Bedfordshire MK43 0AL, UK
6 shared publications- Alison Parker
Affiliation School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
5 shared publications L. Williams
Centre for Creative and Competitive Design, Cranfield University, Bedfordshire MK43 0AL, UK
5 shared publications- Marc Pidou
Cranfield University, College Road, Cranfield, Bedfordshire MK43 0AL, UK
4 shared publications - Athanasios Kolios
DTU Wind and Energy Systems, Technical University of Denmark, 4000 Roskilde, Denmark
3 shared publications
Latest Publications
- Open Access
- 15 April 2022
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 12 (2) , 191-205
Downscaling reverse osmosis for single-household wastewater reuse: towards low-cost decentralised sanitation through a batch open-loop configuration
There is a significant demand for water recycling in low-income countries. However, wastewater infrastructure is primarily decentralised, necessitating the development of affordable household-scale reclamation technology. In this study, a batch open-loop reverse osmosis (RO) system is therefore investigated as a low-cost clean water reclamation route from highly saline concentrated blackwater. In a single-stage configuration, increasing feed pressure from 10 to 30 bars improved selective separation at water recovery exceeding 85%, whereas lower cross-flow velocity improved product recovery, reducing specific permeate energy demand from 21 to 4.8 kWh m−3. Rejection achieved for total phosphorous (99%), chemical oxygen demand (COD, 96%), and final pH (8.7) of the RO permeate was compliant with the ISO30500 reuse standard for discharge. However, the rejection of total nitrogen in the RO permeate was non-compliant with the reuse standard due to the transmission of low-molecular weight (MW) uncharged organic compounds. It is suggested that rejection may be improved by increasing feed pressure to rebalance selectivity but may also be controlled by reducing fluid residence time (storage) to constrain the hydrolysis of urea. The economic analysis identified that a high-pressure 1812 element cost of ∼US$30 meets the sanitation affordability index of US$0.05 capita−1 day−1. However, the unit cost of a high-pressure feed pump must be reduced to ∼US$500 to obtain an affordable system cost. These unit costs can be achieved by manufacturing 1812 elements at economies of scale, and by adopting pumping solutions that have been developed for other applications requiring high pressures and low flows. Overall, our findings suggest that RO in the batch open-loop configuration has the potential to deliver affordable and safe water production from blackwater in a decentralised (single-household) context.
- 15 April 2022
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 12 (2) , 191-205
Open AccessDownscaling reverse osmosis for single-household wastewater reuse: towards low-cost decentralised sanitation through a batch open-loop configuration
There is a significant demand for water recycling in low-income countries. However, wastewater infrastructure is primarily decentralised, necessitating the development of affordable household-scale reclamation technology. In this study, a batch open-loop reverse osmosis (RO) system is therefore investigated as a low-cost clean water reclamation route from highly saline concentrated blackwater. In a single-stage configuration, increasing feed pressure from 10 to 30 bars improved selective separation at water recovery exceeding 85%, whereas lower cross-flow velocity improved product recovery, reducing specific permeate energy demand from 21 to 4.8 kWh m−3. Rejection achieved for total phosphorous (99%), chemical oxygen demand (COD, 96%), and final pH (8.7) of the RO permeate was compliant with the ISO30500 reuse standard for discharge. However, the rejection of total nitrogen in the RO permeate was non-compliant with the reuse standard due to the transmission of low-molecular weight (MW) uncharged organic compounds. It is suggested that rejection may be improved by increasing feed pressure to rebalance selectivity but may also be controlled by reducing fluid residence time (storage) to constrain the hydrolysis of urea. The economic analysis identified that a high-pressure 1812 element cost of ∼US$30 meets the sanitation affordability index of US$0.05 capita−1 day−1. However, the unit cost of a high-pressure feed pump must be reduced to ∼US$500 to obtain an affordable system cost. These unit costs can be achieved by manufacturing 1812 elements at economies of scale, and by adopting pumping solutions that have been developed for other applications requiring high pressures and low flows. Overall, our findings suggest that RO in the batch open-loop configuration has the potential to deliver affordable and safe water production from blackwater in a decentralised (single-household) context.
- Open Access
- 1 September 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 244
Transitioning from electrodialysis to reverse electrodialysis stack design for energy generation from high concentration salinity gradients
- 1 September 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 244
Open AccessTransitioning from electrodialysis to reverse electrodialysis stack design for energy generation from high concentration salinity gradients
- Open Access
- 1 June 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 627, 119245
Scale-up of reverse electrodialysis for energy generation from high concentration salinity gradients
- 1 June 2021
- Published by Elsevier in Journal of Membrane Science
- Vol. 627, 119245
Open AccessScale-up of reverse electrodialysis for energy generation from high concentration salinity gradients
- Open Access
- 1 December 2020
- Published by Elsevier in Desalination
- Vol. 496, 114711
Managing power dissipation in closed-loop reverse electrodialysis to maximise energy recovery during thermal-to-electric conversion
- 1 December 2020
- Published by Elsevier in Desalination
- Vol. 496, 114711
Open AccessManaging power dissipation in closed-loop reverse electrodialysis to maximise energy recovery during thermal-to-electric conversion
- Open Access
- 1 December 2020
- Published by Elsevier in Separation and Purification Technology
- Vol. 253, 117547
Ultrafiltration pretreatment enhances membrane distillation flux, resilience and permeate quality during water recovery from concentrated blackwater (urine/faeces)
- 1 December 2020
- Published by Elsevier in Separation and Purification Technology
- Vol. 253, 117547
Open AccessUltrafiltration pretreatment enhances membrane distillation flux, resilience and permeate quality during water recovery from concentrated blackwater (urine/faeces)
- 2 January 2020
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 56 (1) , 129-140
Reconciliation of gas to liquid mass transfer in parallel and transverse flow (cross-flow) hollow fiber membrane contactors (HFMC) for CO2 absorption
Previous studies have found difficulties in reconciling mass transfer between membrane contactors of different geometries, which has been attributed to differences in fluid mixing. In this study, we compare the two most commonly adopted geometries (parallel and transverse flow) and use residence time distribution (RTD) analysis to verify the influence of geometry on fluid mixing in addition to developing a generalized correlation that can collectively describe mass transfer for both geometries. Lumen-side mass transfer was well described by the Lévêque solution in well-developed laminar conditions for both parallel and transverse flow modules. However, considerably lower mass transfer was identified for shell-side flow in the parallel fiber configuration, with RTD analysis providing confirmation that this was due to shell-side bypass which reduced mean fluid residence time in the contactor to below that of the theoretical residence time. The mean residence time calculated from RTD analysis enabled reconciliation of mass transfer data between both geometries, such that mass transfer could be adequately described for both configurations using: . The Reynolds number exponent indicated transitional mass transfer despite operation firmly within the laminar regime, which would indicate an enhancement in mass transfer provided by secondary flow effects within tightly packed fiber bundles. Whilst previously observed, for example in heat transfer analogies, such dependencies are generally more closely associated with parallel flow rather than ‘classical’ cross-flow modules in which fluid flow is explicitly perpendicular to the fiber bundle, and indicates that mass transfer in transverse flow may be better described as parallel flow, which confirms previous assumptions. Importantly, this study demonstrates the capability to reconcile mass transfer between modules of different geometries and permits the opportunity to project process design and scale-up between the two most commonly applied membrane contactor module geometries.- 2 January 2020
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 56 (1) , 129-140
Reconciliation of gas to liquid mass transfer in parallel and transverse flow (cross-flow) hollow fiber membrane contactors (HFMC) for CO2 absorption
Previous studies have found difficulties in reconciling mass transfer between membrane contactors of different geometries, which has been attributed to differences in fluid mixing. In this study, we compare the two most commonly adopted geometries (parallel and transverse flow) and use residence time distribution (RTD) analysis to verify the influence of geometry on fluid mixing in addition to developing a generalized correlation that can collectively describe mass transfer for both geometries. Lumen-side mass transfer was well described by the Lévêque solution in well-developed laminar conditions for both parallel and transverse flow modules. However, considerably lower mass transfer was identified for shell-side flow in the parallel fiber configuration, with RTD analysis providing confirmation that this was due to shell-side bypass which reduced mean fluid residence time in the contactor to below that of the theoretical residence time. The mean residence time calculated from RTD analysis enabled reconciliation of mass transfer data between both geometries, such that mass transfer could be adequately described for both configurations using: . The Reynolds number exponent indicated transitional mass transfer despite operation firmly within the laminar regime, which would indicate an enhancement in mass transfer provided by secondary flow effects within tightly packed fiber bundles. Whilst previously observed, for example in heat transfer analogies, such dependencies are generally more closely associated with parallel flow rather than ‘classical’ cross-flow modules in which fluid flow is explicitly perpendicular to the fiber bundle, and indicates that mass transfer in transverse flow may be better described as parallel flow, which confirms previous assumptions. Importantly, this study demonstrates the capability to reconcile mass transfer between modules of different geometries and permits the opportunity to project process design and scale-up between the two most commonly applied membrane contactor module geometries.- Open Access
- 1 August 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 584, 343-352
Hybrid membrane distillation reverse electrodialysis configuration for water and energy recovery from human urine: An opportunity for off-grid decentralised sanitation
- 1 August 2019
- Published by Elsevier in Journal of Membrane Science
- Vol. 584, 343-352
Open AccessHybrid membrane distillation reverse electrodialysis configuration for water and energy recovery from human urine: An opportunity for off-grid decentralised sanitation
- Open Access
- 23 January 2019
- Published by F1000 Research Ltd in Gates Open Research
- Vol. 2, 50
Improving energy efficiency of electrochemical blackwater disinfection through sequential reduction of suspended solids and chemical oxygen demand
Onsite reuse of blackwater requires removal of considerable amounts of suspended solids and organic material in addition to inactivation of pathogens. Previously, we showed that electrochemical treatment could be used for effective pathogen inactivation in blackwater, but was inadequate to remove solids and organics to emerging industry standards. Further, we found that as solids and organics accumulate with repeated recycling, electrochemical treatment becomes less energetically sustainable. Here, we describe a pilot study in which concentrated blackwater is pretreated with ultrafiltration and granular activated carbon prior to electrochemical disinfection, and show that this combination of treatments removes 75-99% of chemical oxygen demand, 92-100% of total suspended solids, and improves the energy efficiency of electrochemical blackwater treatment by an order of magnitude.
- 23 January 2019
- Published by F1000 Research Ltd in Gates Open Research
- Vol. 2, 50
Open AccessImproving energy efficiency of electrochemical blackwater disinfection through sequential reduction of suspended solids and chemical oxygen demand
Onsite reuse of blackwater requires removal of considerable amounts of suspended solids and organic material in addition to inactivation of pathogens. Previously, we showed that electrochemical treatment could be used for effective pathogen inactivation in blackwater, but was inadequate to remove solids and organics to emerging industry standards. Further, we found that as solids and organics accumulate with repeated recycling, electrochemical treatment becomes less energetically sustainable. Here, we describe a pilot study in which concentrated blackwater is pretreated with ultrafiltration and granular activated carbon prior to electrochemical disinfection, and show that this combination of treatments removes 75-99% of chemical oxygen demand, 92-100% of total suspended solids, and improves the energy efficiency of electrochemical blackwater treatment by an order of magnitude.
- Open Access
- 29 November 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 5 (1) , 161-171
Quantification of liquid phase faecal odourants to evaluate membrane technology for wastewater reuse from decentralised sanitation facilities
Public willingness to use decentralised sanitation facilities or arising water products is discouraged due to malodour, preventing improved sanitation practices or water reuse opportunities in low income countries. Whilst odour is characterised in the gas phase, it originates in the liquid phase. Consequently, controlling odour at source could prevent gas-phase partitioning and limit produced water contamination. This study therefore developed an analytical method for the quantitation of a range of liquid phase volatile organic compounds (VOCs) classified into eight chemical groups, known to be primary indicators of faecal odour, to provide characterisation of real fluids and to permit evaluation of several potential membrane separation technologies for liquid phase odourant separation. The gas chromatography mass spectrometry method provided quantitation in the range of 0.005 mg L−1 to 100 mg L−1 with instrument detection limits ranging from 0.005 mg L−1 to 0.124 mg L−1. Linear calibration curves were achieved (r2 > 0.99) with acceptable accuracy (77–115%) and precision (−1, and good accuracy (98–104%) and precision (−1. Pre-concentration of real samples was facilitated via solid phase extraction. Subsequent application of the method to the evaluation of two thermally driven membranes based on hydrophilic (polyvinyl alcohol) and hydrophobic (polydimethylsiloxane) polymers evidenced contrasting separation profiles. Importantly, this study demonstrates the method's utility for liquid phase VOC determination which is of use to a range of disciplines, including healthcare professionals, taste and odour specialists and public health engineers.
- 29 November 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 5 (1) , 161-171
Open AccessQuantification of liquid phase faecal odourants to evaluate membrane technology for wastewater reuse from decentralised sanitation facilities
Public willingness to use decentralised sanitation facilities or arising water products is discouraged due to malodour, preventing improved sanitation practices or water reuse opportunities in low income countries. Whilst odour is characterised in the gas phase, it originates in the liquid phase. Consequently, controlling odour at source could prevent gas-phase partitioning and limit produced water contamination. This study therefore developed an analytical method for the quantitation of a range of liquid phase volatile organic compounds (VOCs) classified into eight chemical groups, known to be primary indicators of faecal odour, to provide characterisation of real fluids and to permit evaluation of several potential membrane separation technologies for liquid phase odourant separation. The gas chromatography mass spectrometry method provided quantitation in the range of 0.005 mg L−1 to 100 mg L−1 with instrument detection limits ranging from 0.005 mg L−1 to 0.124 mg L−1. Linear calibration curves were achieved (r2 > 0.99) with acceptable accuracy (77–115%) and precision (−1, and good accuracy (98–104%) and precision (−1. Pre-concentration of real samples was facilitated via solid phase extraction. Subsequent application of the method to the evaluation of two thermally driven membranes based on hydrophilic (polyvinyl alcohol) and hydrophobic (polydimethylsiloxane) polymers evidenced contrasting separation profiles. Importantly, this study demonstrates the method's utility for liquid phase VOC determination which is of use to a range of disciplines, including healthcare professionals, taste and odour specialists and public health engineers.