Matthew J. Kennedy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthew J. Kennedy has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Carl A. Batt
Department of Food Science, Cornell University, Ithaca, New York 14853, USA
2 shared publicationsScott J. Stelick
Department of Food Science, Cornell University, Ithaca, NY, 14853, USA
2 shared publicationsA. C. Gossard
Department of Electrical and Computer Engineering University of California Santa Barbara California 93106 USA
1 shared publicationAndrew Yen
Cornell Biomedical Sciences Flow Cytometry Core Laboratory, College of Veterinary Medicine, Cornell University, Ithaca, NY, 14853, USA
1 shared publication- Carl A. Batt
Department of Food Science, Cornell University, Ithaca, NY, 14853, USA
1 shared publication - Daehwan Jung
Korea Institute of Science and Technology
1 shared publication
Latest Publications
- Open Access
- 1 April 2018
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 54 (7) , 432-433
490 fs pulse generation from passively mode‐locked single section quantum dot laser directly grown on on‐axis GaP/Si
We demonstrate, for the first time, a single section passively mode‐locked InAs/InGaAs quantum dot laser directly grown on on‐axis (001) GaP/Si substrate. The laser has a continuous‐wave threshold current of 34 mA at 20°C. By forward biasing the laser gain section current at 470 mA, 490 fs pulse generation with 31 GHz repetition rate can be obtained. This simple femtosecond pulse generation structure with CMOS fabrication compatibility makes the laser a promising light source candidate in future large‐scale silicon photonic applications.
- 1 April 2018
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 54 (7) , 432-433
Open Access490 fs pulse generation from passively mode‐locked single section quantum dot laser directly grown on on‐axis GaP/Si
We demonstrate, for the first time, a single section passively mode‐locked InAs/InGaAs quantum dot laser directly grown on on‐axis (001) GaP/Si substrate. The laser has a continuous‐wave threshold current of 34 mA at 20°C. By forward biasing the laser gain section current at 470 mA, 490 fs pulse generation with 31 GHz repetition rate can be obtained. This simple femtosecond pulse generation structure with CMOS fabrication compatibility makes the laser a promising light source candidate in future large‐scale silicon photonic applications.
- 1 December 2012
- Published by AIP Publishing in Biomicrofluidics
- Vol. 6 (4) , 44119
Analysis of a laminar-flow diffusional mixer for directed self-assembly of liposomes
The present work describes the operation and simulation of a microfluidic laminar-flow mixer. Diffusive mixing takes place between a core solution containing lipids in ethanol and a sheath solution containing aqueous buffer, leading to self assembly of liposomes. Present device architecture hydrodynamically focuses the lipid solution into a cylindrical core positioned at the center of a microfluidic channel of 125 × 125-μm2 cross-section. Use of the device produces liposomes in the size range of 100–300 nm, with larger liposomes forming at greater ionic strength in the sheath solution and at lower lipid concentration in the core solution. Finite element simulations compute the concentration distributions of solutes at axial distances of greater than 100 channel widths. These simulations reduce computation time and enable computation at long axial distances by utilizing long hexahedral elements in the axial flow region and fine tetrahedral elements in the hydrodynamic focusing region. Present meshing technique is generally useful for simulation of long microfluidic channels and is fully implementable using comsol Multiphysics. Confocal microscopy provides experimental validation of the simulations using fluorescent solutions containing fluorescein or enhanced green fluorescent protein.
- 1 December 2012
- Published by AIP Publishing in Biomicrofluidics
- Vol. 6 (4) , 44119
Analysis of a laminar-flow diffusional mixer for directed self-assembly of liposomes
The present work describes the operation and simulation of a microfluidic laminar-flow mixer. Diffusive mixing takes place between a core solution containing lipids in ethanol and a sheath solution containing aqueous buffer, leading to self assembly of liposomes. Present device architecture hydrodynamically focuses the lipid solution into a cylindrical core positioned at the center of a microfluidic channel of 125 × 125-μm2 cross-section. Use of the device produces liposomes in the size range of 100–300 nm, with larger liposomes forming at greater ionic strength in the sheath solution and at lower lipid concentration in the core solution. Finite element simulations compute the concentration distributions of solutes at axial distances of greater than 100 channel widths. These simulations reduce computation time and enable computation at long axial distances by utilizing long hexahedral elements in the axial flow region and fine tetrahedral elements in the hydrodynamic focusing region. Present meshing technique is generally useful for simulation of long microfluidic channels and is fully implementable using comsol Multiphysics. Confocal microscopy provides experimental validation of the simulations using fluorescent solutions containing fluorescein or enhanced green fluorescent protein.
- 19 February 2011
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 11 (2) , 119-128
Parameters affecting the shape of a hydrodynamically focused stream
- 19 February 2011
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 11 (2) , 119-128
Parameters affecting the shape of a hydrodynamically focused stream
- 1 January 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (6) , 1138-43
Hydrodynamic optical alignment for microflow cytometry
A microfabricated flow cytometer has been developed that is capable of detecting nearly all of the microparticles in an aqueous suspension. Current design allows for integrated coupling between an optical fiber-based detection system and the particle stream via hydrodynamic focusing. By adjusting the relative flow-rates at the auxiliary inputs of the focusing manifold, the particle stream can be steered out-of-plane relative to the illuminating laser, and similarly the particle stream can be squeezed or expanded. The microfabricated device was constructed in polydimethylsiloxane with cross-sectional microfluidic dimensions of 125 µm×125 µm. Using the present device and method, fluorescent microparticles in aqueous solution were counted at an absolute counting efficiency of 91±4%. The coefficient of variation of the fluorescence pulse-heights for far-red fluorescent microparticles was 15%. The device exhibited a linear response to fluorescence intensity calibration microparticles as shown by comparison with a commercial cytometer instrument.
- 1 January 2011
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 11 (6) , 1138-43
Hydrodynamic optical alignment for microflow cytometry
A microfabricated flow cytometer has been developed that is capable of detecting nearly all of the microparticles in an aqueous suspension. Current design allows for integrated coupling between an optical fiber-based detection system and the particle stream via hydrodynamic focusing. By adjusting the relative flow-rates at the auxiliary inputs of the focusing manifold, the particle stream can be steered out-of-plane relative to the illuminating laser, and similarly the particle stream can be squeezed or expanded. The microfabricated device was constructed in polydimethylsiloxane with cross-sectional microfluidic dimensions of 125 µm×125 µm. Using the present device and method, fluorescent microparticles in aqueous solution were counted at an absolute counting efficiency of 91±4%. The coefficient of variation of the fluorescence pulse-heights for far-red fluorescent microparticles was 15%. The device exhibited a linear response to fluorescence intensity calibration microparticles as shown by comparison with a commercial cytometer instrument.
- 17 February 2009
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 7 (4) , 569-578
Hydrodynamic focusing with a microlithographic manifold: controlling the vertical position of a focused sample
- 17 February 2009
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 7 (4) , 569-578
Hydrodynamic focusing with a microlithographic manifold: controlling the vertical position of a focused sample