Keitaro Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Keitaro Ito has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Fumihito Arai
Department of Micro-Nano System Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya
4 shared publications- Fumihito Arai
The University of Tokyo
2 shared publications Shinya Sakuma
Department of Micro-Nano System Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya
2 shared publications- Shinya Sakuma
Nagoya University
2 shared publications - Shinya Sakuma
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka, Fukuoka 819-0395, Japan
2 shared publications - Takanori Takebe
Graduate School of Medicine, and Premium Research Institute for Human Metaverse Medicine (WPI-PRIMe), the University of Osaka 1 Department of Genome Biology Suita, Osaka 565-0871
2 shared publications
Latest Publications
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Bend Stress Isolation Structure on the PCB: Fourfold Crab-Leg Stabilize Accelerometer Bias
Assembly-induced stresses such as printed circuit board (PCB) warpage and clamp loads propagate through the package to the MEMS die and perturb accelerometer bias. This letter presents a PCB-integrated stress-relief structure: a planar, fourfold-symmetric crab-leg (folded-beam) flexure that forms an “IMU island” via through-slots, attenuating stress transmission regardless of load direction while preserving four-sided routing. Finite-element analysis of a molded inertial measurement unit (IMU) package on a clamped–clamped PCB under mid-span deflection shows that the area-averaged von Mises stress at the MEMS anchor interface is reduced to 0.23× compared with a plain PCB. A clamped–clamped bending fixture with a recessed loading pin, load sensing, 3-D surface profiling, and a calibration–inference procedure maps measured displacements to a plain-PCB-equivalent surface stress, enabling fair comparison across layouts over an approximately ±40 MPa range. Measurements confirm that, relative to the plain PCB, accelerometer bias change decreases from 4.9 mG to 1.6 mG on X (0.32×) and from 48 mG to 8.4 mG on Z (0.18×), with no clear reduction on Y. These results demonstrate that board-level flexures reduce assembly-induced bias drift and provide a practical, user-implementable approach to stabilize MEMS IMU accelerometers without altering the device or package.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 10 (2) , 1-4
Bend Stress Isolation Structure on the PCB: Fourfold Crab-Leg Stabilize Accelerometer Bias
Assembly-induced stresses such as printed circuit board (PCB) warpage and clamp loads propagate through the package to the MEMS die and perturb accelerometer bias. This letter presents a PCB-integrated stress-relief structure: a planar, fourfold-symmetric crab-leg (folded-beam) flexure that forms an “IMU island” via through-slots, attenuating stress transmission regardless of load direction while preserving four-sided routing. Finite-element analysis of a molded inertial measurement unit (IMU) package on a clamped–clamped PCB under mid-span deflection shows that the area-averaged von Mises stress at the MEMS anchor interface is reduced to 0.23× compared with a plain PCB. A clamped–clamped bending fixture with a recessed loading pin, load sensing, 3-D surface profiling, and a calibration–inference procedure maps measured displacements to a plain-PCB-equivalent surface stress, enabling fair comparison across layouts over an approximately ±40 MPa range. Measurements confirm that, relative to the plain PCB, accelerometer bias change decreases from 4.9 mG to 1.6 mG on X (0.32×) and from 48 mG to 8.4 mG on Z (0.18×), with no clear reduction on Y. These results demonstrate that board-level flexures reduce assembly-induced bias drift and provide a practical, user-implementable approach to stabilize MEMS IMU accelerometers without altering the device or package.
- Open Access
- 5 December 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (12) , 221
Temporal Transition of Mechanical Characteristics of HUVEC/MSC Spheroids Using a Microfluidic Chip with Force Sensor Probes
In this paper, we focus on the mechanical characterization of co-cultured spheroids of human umbilical vein endothelial cells (HUVECs) and mesenchymal stem cells (MSC) (HUVEC/MSC spheroids). HUVEC/MSC spheroids aggregate during culture, thereby decreasing in size. Since this size decrease can be caused by the contractility generated by the actomyosin of MSCs, which are intracellular frames, we can expect that there is a temporal transition for the mechanical characteristics, such as stiffness, during culture. To measure the mechanical characteristics, we use a microfluidic chip that is integrated with force sensor probes. We show the details of the measurement configuration and the results of mechanical characterization of the HUVEC/MSC spheroids. To evaluate the stiffness of the spheroids, we introduce the stiffness index, which essentially shows a spring constant per unit size of the spheroid at a certain time during measurement. From the measurement results, we confirmed that the stiffness index firstly increased during the days of culture, although after four days of culture, the stiffness index decreased. We confirmed that the proposed system can measure the stiffness of HUVEC/MSC spheroids.
- 5 December 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (12) , 221
Open AccessTemporal Transition of Mechanical Characteristics of HUVEC/MSC Spheroids Using a Microfluidic Chip with Force Sensor Probes
In this paper, we focus on the mechanical characterization of co-cultured spheroids of human umbilical vein endothelial cells (HUVECs) and mesenchymal stem cells (MSC) (HUVEC/MSC spheroids). HUVEC/MSC spheroids aggregate during culture, thereby decreasing in size. Since this size decrease can be caused by the contractility generated by the actomyosin of MSCs, which are intracellular frames, we can expect that there is a temporal transition for the mechanical characteristics, such as stiffness, during culture. To measure the mechanical characteristics, we use a microfluidic chip that is integrated with force sensor probes. We show the details of the measurement configuration and the results of mechanical characterization of the HUVEC/MSC spheroids. To evaluate the stiffness of the spheroids, we introduce the stiffness index, which essentially shows a spring constant per unit size of the spheroid at a certain time during measurement. From the measurement results, we confirmed that the stiffness index firstly increased during the days of culture, although after four days of culture, the stiffness index decreased. We confirmed that the proposed system can measure the stiffness of HUVEC/MSC spheroids.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical characterization system using on-chip probe with wide range actuation
In this paper, we focus on mechanical characterization of human umbilical vein endothelial cell (HUVEC) and mesenchymal stem cell (MSC) co-cultured spheroids. HUVEC/MSC co-cultured spheroid has a characteristic that the size becomes compact with culture day increase. In order to measure the mechanical characteristics of size changing spheroids, we apply whole chip deformation mechanism to the actuation method of on-chip probes for wide range actuation. Finally, we evaluate the stiffness of spheroids by using stiffness-index.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Mechanical characterization system using on-chip probe with wide range actuation
In this paper, we focus on mechanical characterization of human umbilical vein endothelial cell (HUVEC) and mesenchymal stem cell (MSC) co-cultured spheroids. HUVEC/MSC co-cultured spheroid has a characteristic that the size becomes compact with culture day increase. In order to measure the mechanical characteristics of size changing spheroids, we apply whole chip deformation mechanism to the actuation method of on-chip probes for wide range actuation. Finally, we evaluate the stiffness of spheroids by using stiffness-index.
- Open Access
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P2-W10_1
1P2-W10 Indexing of Cell Mechanical Characteristics using a Width Tunable Vibro-mirochannel
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2015, _1P2-W10_1
Open Access1P2-W10 Indexing of Cell Mechanical Characteristics using a Width Tunable Vibro-mirochannel
- Open Access
- 30 August 2014
- Published by Springer Nature in ROBOMECH Journal
- Vol. 1 (1) , 5
On-Chip Gel-Valve Using Photoprocessable Thermoresponsive Gel
- 30 August 2014
- Published by Springer Nature in ROBOMECH Journal
- Vol. 1 (1) , 5
Open AccessOn-Chip Gel-Valve Using Photoprocessable Thermoresponsive Gel
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A2-O05_1
1A2-O05 Functional microfluidic devices by using Bioresist(Nano/Micro Fluid System)
We present an innovative polymer actuator made of photoprocessible thermo-sensitive gel. The gel, which we call "Bioresist", is thermo responsible biocompatible photoresist. Novelties of this Bioresist are shown as follows. (1) It is possible to fabricate arbitrary 2D pattern using photolithography. (2) Its volume is controlled by only heating. Therefore, it can be applied to the thermally controllable functional microfluidic devices. Herein, we demonstrated this innovative gel as applications of microfluidic components controlled by microheaters. Its properties were evaluated. Firstly, the relationship between expansion rate of Bioresist and temperature was measured. Secondly, the normally closed microvalve was fabricated for the fluid control. Then, the performance of this gel actuator was evaluated. Finally, we applied this microcomponent to the sorter of cells flowing in the microchannel.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2013, _1A2-O05_1
1A2-O05 Functional microfluidic devices by using Bioresist(Nano/Micro Fluid System)
We present an innovative polymer actuator made of photoprocessible thermo-sensitive gel. The gel, which we call "Bioresist", is thermo responsible biocompatible photoresist. Novelties of this Bioresist are shown as follows. (1) It is possible to fabricate arbitrary 2D pattern using photolithography. (2) Its volume is controlled by only heating. Therefore, it can be applied to the thermally controllable functional microfluidic devices. Herein, we demonstrated this innovative gel as applications of microfluidic components controlled by microheaters. Its properties were evaluated. Firstly, the relationship between expansion rate of Bioresist and temperature was measured. Secondly, the normally closed microvalve was fabricated for the fluid control. Then, the performance of this gel actuator was evaluated. Finally, we applied this microcomponent to the sorter of cells flowing in the microchannel.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2A1-S02_1
2A1-S02 Ultrahigh Speed On-chip Force Measurement by Using Capacitive Force Sensor(Bio Assembler for 3D Cellular System Innovation)
In this paper, we propose the on-chip capacitive force sensor for ultrahigh speed cellular force measurement. In order to apply the capacitive force sensor to microfluidic chip, on-chip force sensor utilizes the air-liquid interface due to isolate liquid form comb electrodes. We have designed and fabricated the capacitive force sensor with cell culture chamber as a kind of microchannel to the several pm order cell. Air-liquid interface between the force sensor tip and comb electrodes have achieved. As a result, we have succeeded in measurement of capacitance of on-chip force sensor as a function of displacement of probe tip in wet condition.
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
- Vol. 2012, _2A1-S02_1
2A1-S02 Ultrahigh Speed On-chip Force Measurement by Using Capacitive Force Sensor(Bio Assembler for 3D Cellular System Innovation)
In this paper, we propose the on-chip capacitive force sensor for ultrahigh speed cellular force measurement. In order to apply the capacitive force sensor to microfluidic chip, on-chip force sensor utilizes the air-liquid interface due to isolate liquid form comb electrodes. We have designed and fabricated the capacitive force sensor with cell culture chamber as a kind of microchannel to the several pm order cell. Air-liquid interface between the force sensor tip and comb electrodes have achieved. As a result, we have succeeded in measurement of capacitance of on-chip force sensor as a function of displacement of probe tip in wet condition.