Mariya A. Pindrus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mariya A. Pindrus has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Devendra S. Kalonia
Department of Pharmaceutical Sciences , University of Connecticut , U-3092, Storrs , Connecticut 06269 , United States
2 shared publicationsSandeep Yadav
Late Stage Pharmaceutical Development , Genentech, Inc ., 1 DNA Way , South San Francisco , California 94080 , United States
2 shared publicationsSteven J. Shire
Late Stage Pharmaceutical Development , Genentech, Inc ., 1 DNA Way , South San Francisco , California 94080 , United States
2 shared publications- Devendra S. Kalonia
Department of Pharmaceutical Sciences, University of Connecticut , Storrs, Connecticut 06269, United States
1 shared publication James L. Cole
Department of Molecular and Cell Biology and Department of Chemistry, University of Connecticut, Storrs, CT, 06269, USA
1 shared publicationJapneet Kaur
Department of Pharmaceutical Sciences, University of Connecticut, U-3092, Storrs, CT, 06269, USA
1 shared publication
Latest Publications
- 11 July 2018
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 15 (8) , 3133-3142
The Effect of Low Ionic Strength on Diffusion and Viscosity of Monoclonal Antibodies
Purpose: To determine the effect of solution conditions, especially low ionic strength, on the dynamics of molecular diffusion and protein-protein interactions in monoclonal antibody solutions. Methods: The interaction parameter, kD, was calculated from diffusion data obtained from Dynamic Light Scattering (DLS) measurements performed using a Zetasizer®. Theoretical considerations were utilized to evaluate the hard sphere and electrostatic contribution to molecular interactions. Results: At low ionic strengths repulsions were the dominant forces governing behavior of both mAbs. As ionic strength increased, attractions contributed to the behavior of mAb1, while repulsions remained the dominant factor affecting mAb3 behavior. Repulsions alone were not sufficient to affect mAb3 viscosity in water, while presence of repulsions as well as specific attractions was suggested to cause an increase in viscosity of mAb1 in water compared to 15 mM ionic strength. Conclusions: Solution physical properties varied for the mAbs investigated. Our findings highlighted the importance of developing a fundamental understanding of interplay of forces governing solution properties of each individual mAb under low ionic strength conditions. Such understanding is critical in enabling successful development of self-buffered formulations.
- 11 July 2018
- Published by American Chemical Society (ACS) in Molecular Pharmaceutics
- Vol. 15 (8) , 3133-3142
The Effect of Low Ionic Strength on Diffusion and Viscosity of Monoclonal Antibodies
Purpose: To determine the effect of solution conditions, especially low ionic strength, on the dynamics of molecular diffusion and protein-protein interactions in monoclonal antibody solutions. Methods: The interaction parameter, kD, was calculated from diffusion data obtained from Dynamic Light Scattering (DLS) measurements performed using a Zetasizer®. Theoretical considerations were utilized to evaluate the hard sphere and electrostatic contribution to molecular interactions. Results: At low ionic strengths repulsions were the dominant forces governing behavior of both mAbs. As ionic strength increased, attractions contributed to the behavior of mAb1, while repulsions remained the dominant factor affecting mAb3 behavior. Repulsions alone were not sufficient to affect mAb3 viscosity in water, while presence of repulsions as well as specific attractions was suggested to cause an increase in viscosity of mAb1 in water compared to 15 mM ionic strength. Conclusions: Solution physical properties varied for the mAbs investigated. Our findings highlighted the importance of developing a fundamental understanding of interplay of forces governing solution properties of each individual mAb under low ionic strength conditions. Such understanding is critical in enabling successful development of self-buffered formulations.
- 27 July 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (11) , 2250-2259
Effect of Aggregation on the Hydrodynamic Properties of Bovine Serum Albumin
- 27 July 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (11) , 2250-2259
Effect of Aggregation on the Hydrodynamic Properties of Bovine Serum Albumin
- 2 February 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (4) , 836-846
Challenges in Determining Intrinsic Viscosity Under Low Ionic Strength Solution Conditions
To determine the intrinsic viscosity of several monoclonal antibodies (mAbs) under varying pH and ionic strength solution conditions. An online viscosity detector attached to HPLC (Viscotek®) was used to determine the intrinsic viscosity of mAbs. The Ross and Minton equation was used for viscosity prediction at high protein concentrations. Bulk viscosity was determined by a Cambridge viscometer. At 15 mM ionic strength, intrinsic viscosity of the mAbs determined by the single-point approach varied from 5.6 to 6.4 mL/g with changes in pH. High ionic strength did not significantly alter intrinsic viscosity, while a significant increase (up to 24.0 mL/g) was observed near zero mM. No difference in bulk viscosity of mAb3 was observed around pH 6 as a function of ionic strength. Data analysis revealed that near zero mM ionic strength limitations of the single-point technique result in erroneously high intrinsic viscosity. Intrinsic viscosity is a valuable tool that can be used to model baseline viscosity at higher protein concentrations. However, it is not predictive of solution non-ideality at higher protein concentrations. Furthermore, breakdown of numerous assumptions limits the applicability of experimental techniques near zero mM ionic strength conditions. For molecules and conditions studied, the single-point approach produced reliable intrinsic viscosity results at 15 mM. However, this approach must be used with caution near zero mM ionic strength. Data analysis can be used to reveal whether determined intrinsic viscosity is reliable or erroneously high.
- 2 February 2017
- Published by Springer Nature in Pharmaceutical Research
- Vol. 34 (4) , 836-846
Challenges in Determining Intrinsic Viscosity Under Low Ionic Strength Solution Conditions
To determine the intrinsic viscosity of several monoclonal antibodies (mAbs) under varying pH and ionic strength solution conditions. An online viscosity detector attached to HPLC (Viscotek®) was used to determine the intrinsic viscosity of mAbs. The Ross and Minton equation was used for viscosity prediction at high protein concentrations. Bulk viscosity was determined by a Cambridge viscometer. At 15 mM ionic strength, intrinsic viscosity of the mAbs determined by the single-point approach varied from 5.6 to 6.4 mL/g with changes in pH. High ionic strength did not significantly alter intrinsic viscosity, while a significant increase (up to 24.0 mL/g) was observed near zero mM. No difference in bulk viscosity of mAb3 was observed around pH 6 as a function of ionic strength. Data analysis revealed that near zero mM ionic strength limitations of the single-point technique result in erroneously high intrinsic viscosity. Intrinsic viscosity is a valuable tool that can be used to model baseline viscosity at higher protein concentrations. However, it is not predictive of solution non-ideality at higher protein concentrations. Furthermore, breakdown of numerous assumptions limits the applicability of experimental techniques near zero mM ionic strength conditions. For molecules and conditions studied, the single-point approach produced reliable intrinsic viscosity results at 15 mM. However, this approach must be used with caution near zero mM ionic strength. Data analysis can be used to reveal whether determined intrinsic viscosity is reliable or erroneously high.