Aamer Saleem
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aamer Saleem has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- David Arthur Hutchins
School of Engineering, University of Warwick, Coventry, U.K.
7 shared publications Roger J. Green
The Univ. of Warwick (United Kingdom)
5 shared publications- Lee Andrew John Davis
School of Engineering, University of Warwick, Coventry CV4 7AL, UK
4 shared publications Céline Canal
School of Engineering, University of Warwick, Coventry, UK
2 shared publicationsCéline M. Canal
School of Engineering, University of Warwick, Coventry, UK
2 shared publicationsAkram Rashid
Department of Electrical Engineering, Air University Sector E-9 Islamabad, Pakistan
1 shared publication
Latest Publications
- 30 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8546, 85460C
Combined optics and ultrasound for security screening
It has been shown that both optical and acoustic signals can be transmitted through clothing. This means that, in principle, both types of signal could be used for personal screening. In this paper, a description of how each of these signals interacts with clothing, and the information that can be obtained, will be presented. The wavelengths are very different - by three orders of magnitude. In fact, the wavelength of ultrasound is of a similar order of magnitude to that used by THz systems (≤ 1 mm), whereas the optical signals that could be used are typically in the micron or so range. This means that their use for screening relies on totally different mechanisms. In this paper, results will be shown for both types of measurements, where the location of hidden objects can be demonstrated. The imaging resolution that can be obtained will be described, together with a discussion of how both types of energy could be used for improved identification of objects hidden beneath layers of clothing.
- 30 October 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8546, 85460C
Combined optics and ultrasound for security screening
It has been shown that both optical and acoustic signals can be transmitted through clothing. This means that, in principle, both types of signal could be used for personal screening. In this paper, a description of how each of these signals interacts with clothing, and the information that can be obtained, will be presented. The wavelengths are very different - by three orders of magnitude. In fact, the wavelength of ultrasound is of a similar order of magnitude to that used by THz systems (≤ 1 mm), whereas the optical signals that could be used are typically in the micron or so range. This means that their use for screening relies on totally different mechanisms. In this paper, results will be shown for both types of measurements, where the location of hidden objects can be demonstrated. The imaging resolution that can be obtained will be described, together with a discussion of how both types of energy could be used for improved identification of objects hidden beneath layers of clothing.
- Open Access
- 1 January 2012
- Published by QIRT Council
Concurrent near infrared imaging and spectroscopy
- 1 January 2012
- Published by QIRT Council
Open AccessConcurrent near infrared imaging and spectroscopy
- 6 October 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8189, 81890K
Near infrared transmission through clothing: applications in sensing and screening
Experiments have been performed to demonstrate that near infrared (NIR) transmission through a wide range of clothing materials is possible. Studies have shown that the characteristics of NIR transmission are affected by both the type of fibre used, and the weave pattern. A series of experiments has indicated that NIR transmission is also dependent on other variables such as fabric porosity and dye colour. It is shown that, in many cases, transmission coefficients are sufficiently high that imaging and spectroscopy of objects hidden behind clothing samples should be possible. However, while transmission through clothing at NIR wavelengths in the 750-1,700 nm range is often more effective than in the visible or IR regions, the fabrics themselves will modify the transmitted signal in terms of spatial effects, intensity and spectral content. The paper also describes the possible use of near infrared signals to identify objects that are hidden behind clothing layers. This can be done using spectroscopy. It is important, however, to distinguish the various contributions that exist within the backscattered signal. A set of careful laboratory experiments have demonstrated that transmission through a set of different clothing fabrics does modify the spectral content of signals, but that the spectrum of a particular chemical can still be identified, provided certain steps are taken. These involve a set of careful calibration measurements, and the use of processing techniques for the retrieval of data. It will be shown that this is possible for both granular solids and selected liquids.
- 6 October 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8189, 81890K
Near infrared transmission through clothing: applications in sensing and screening
Experiments have been performed to demonstrate that near infrared (NIR) transmission through a wide range of clothing materials is possible. Studies have shown that the characteristics of NIR transmission are affected by both the type of fibre used, and the weave pattern. A series of experiments has indicated that NIR transmission is also dependent on other variables such as fabric porosity and dye colour. It is shown that, in many cases, transmission coefficients are sufficiently high that imaging and spectroscopy of objects hidden behind clothing samples should be possible. However, while transmission through clothing at NIR wavelengths in the 750-1,700 nm range is often more effective than in the visible or IR regions, the fabrics themselves will modify the transmitted signal in terms of spatial effects, intensity and spectral content. The paper also describes the possible use of near infrared signals to identify objects that are hidden behind clothing layers. This can be done using spectroscopy. It is important, however, to distinguish the various contributions that exist within the backscattered signal. A set of careful laboratory experiments have demonstrated that transmission through a set of different clothing fabrics does modify the spectral content of signals, but that the spectrum of a particular chemical can still be identified, provided certain steps are taken. These involve a set of careful calibration measurements, and the use of processing techniques for the retrieval of data. It will be shown that this is possible for both granular solids and selected liquids.
- 16 August 2011
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (10) , 2298-2306
Techniques for quantifying chemicals concealed behind clothing using near infrared spectroscopy
The detection of specific chemicals when concealed behind a layer of clothing is reported using near infrared (NIR) spectroscopy. It is found that concealment modifies the spectrum of a particular chemical when recorded at stand-off ranges of three meters in a diffuse reflection experiment. Chemometric analysis of the spectra has been performed with neural network-based pattern recognition/classification to deal with this problem. Neural networks help to overcome nonlinearities within the calibration/training dataset, affording more robust modelling. The work has been shown to both allow detection of specific chemicals concealed behind a single intervening layer of fabric material, and to estimate the concentration of hydrogen peroxide using partial least squares regression (PLSR).
- 16 August 2011
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (10) , 2298-2306
Techniques for quantifying chemicals concealed behind clothing using near infrared spectroscopy
The detection of specific chemicals when concealed behind a layer of clothing is reported using near infrared (NIR) spectroscopy. It is found that concealment modifies the spectrum of a particular chemical when recorded at stand-off ranges of three meters in a diffuse reflection experiment. Chemometric analysis of the spectra has been performed with neural network-based pattern recognition/classification to deal with this problem. Neural networks help to overcome nonlinearities within the calibration/training dataset, affording more robust modelling. The work has been shown to both allow detection of specific chemicals concealed behind a single intervening layer of fabric material, and to estimate the concentration of hydrogen peroxide using partial least squares regression (PLSR).
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (2160133X) , 1756-1761
Electrocardiogram signal processing for baseline noise removal using blind source separation techniques: A comparative analysis
Efficient processing of Electrocardiogram (ECG) signal is a major goal of this paper. ECG signal measured from the surface of human body is badly effected by different noises like power line noise, muscle noise, lung noise baseline noise. The main causes of baseline noise are breathing, lose sensor contact and body movements. Baseline noise is a low frequency signal. Baseline will disturb the whole cycle of ECG signal but mainly the low frequency part. T-wave is a part of ECG signal related to a phenomenon associated with increased risk of death and baseline wandering may prevent its correct detection. Different algorithm were applied for removal of this noise by different researchers like Kalman filter, Cubic spline, Moving average. We apply projection pursuit gradient ascent algorithm in a previous paper and observe the results in term of standard deviation of the error signal for different types of baseline noises. In this paper I am comparing the results of projection pursuit gradient ascent algorithm (PPGAA) and Independent Component Analysis (ICA) FASTICA algorithm for removing this noise. Results of FASTICA were also analyzed in the presence of 32db additive Gaussian noise. Then a comparative study of these algorithms was done and results were compared for baseline noise removal.
- 1 July 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4 (2160133X) , 1756-1761
Electrocardiogram signal processing for baseline noise removal using blind source separation techniques: A comparative analysis
Efficient processing of Electrocardiogram (ECG) signal is a major goal of this paper. ECG signal measured from the surface of human body is badly effected by different noises like power line noise, muscle noise, lung noise baseline noise. The main causes of baseline noise are breathing, lose sensor contact and body movements. Baseline noise is a low frequency signal. Baseline will disturb the whole cycle of ECG signal but mainly the low frequency part. T-wave is a part of ECG signal related to a phenomenon associated with increased risk of death and baseline wandering may prevent its correct detection. Different algorithm were applied for removal of this noise by different researchers like Kalman filter, Cubic spline, Moving average. We apply projection pursuit gradient ascent algorithm in a previous paper and observe the results in term of standard deviation of the error signal for different types of baseline noises. In this paper I am comparing the results of projection pursuit gradient ascent algorithm (PPGAA) and Independent Component Analysis (ICA) FASTICA algorithm for removing this noise. Results of FASTICA were also analyzed in the presence of 32db additive Gaussian noise. Then a comparative study of these algorithms was done and results were compared for baseline noise removal.
- 12 November 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 84-91
Remote identification of chemicals concealed behind clothing using near infrared spectroscopy
Measurements are presented which demonstrate that near infrared (NIR) spectroscopy can be used to identify chemicals concealed behind clothing. This has been achieved for detector stand-off distances of 3 m. The optical properties of a range of clothing materials have been investigated, and the transmission of NIR signals found to be sufficient for spectroscopy. The study has shown that granular solid materials can be identified when hidden behind a layer of clothing. Examples of chemicals used in this study include ammonium nitrate and other ammonium salts. Details of the current measurements and results are given, together with suggestions for increasing detection sensitivity.
- 12 November 2010
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 3 (1) , 84-91
Remote identification of chemicals concealed behind clothing using near infrared spectroscopy
Measurements are presented which demonstrate that near infrared (NIR) spectroscopy can be used to identify chemicals concealed behind clothing. This has been achieved for detector stand-off distances of 3 m. The optical properties of a range of clothing materials have been investigated, and the transmission of NIR signals found to be sufficient for spectroscopy. The study has shown that granular solid materials can be identified when hidden behind a layer of clothing. Examples of chemicals used in this study include ammonium nitrate and other ammonium salts. Details of the current measurements and results are given, together with suggestions for increasing detection sensitivity.
- 7 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7838, 78380G
Near-infrared spectroscopy for personal screening
This paper will demonstrate that near infrared (NIR) signals at wavelengths in the range 0.9 to 2.5 microns can be used for personal screening applications. At these wavelengths, there is sufficient spectral information to provide chemical identification, while still providing transmission through many types of common clothing materials. Thus, chemical identification in diffuse reflection is possible. Initial measurements on selected clothing materials have indicated that there is sufficient transmission to allow NIR spectra from concealed chemicals to be collected. The effect of the clothing material on the observed spectra has also been quantified. The clothing materials ranged from cotton to man-made fibres. Spectra have been collected at stand-off distances of several metres or more, using a suitable lens system and an NIR spectrometer. The optics required to achieve this will be described, and some spectra from chemicals hidden behind clothing will be presented. The further steps necessary to provide correct identification of chemicals such as ammonium nitrate in granular form will also be given, involving signal analysis methods. A set of spectra will be shown that have been collected and analysed, for a wide range of clothing fabric materials, indicating that the technique could have wide application to personal screening situations.
- 7 October 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7838, 78380G
Near-infrared spectroscopy for personal screening
This paper will demonstrate that near infrared (NIR) signals at wavelengths in the range 0.9 to 2.5 microns can be used for personal screening applications. At these wavelengths, there is sufficient spectral information to provide chemical identification, while still providing transmission through many types of common clothing materials. Thus, chemical identification in diffuse reflection is possible. Initial measurements on selected clothing materials have indicated that there is sufficient transmission to allow NIR spectra from concealed chemicals to be collected. The effect of the clothing material on the observed spectra has also been quantified. The clothing materials ranged from cotton to man-made fibres. Spectra have been collected at stand-off distances of several metres or more, using a suitable lens system and an NIR spectrometer. The optics required to achieve this will be described, and some spectra from chemicals hidden behind clothing will be presented. The further steps necessary to provide correct identification of chemicals such as ammonium nitrate in granular form will also be given, involving signal analysis methods. A set of spectra will be shown that have been collected and analysed, for a wide range of clothing fabric materials, indicating that the technique could have wide application to personal screening situations.