Niklas Marklund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Niklas Marklund has a total of 737 co-authors. Here are the top co-authors by number of shared publications:
- Fredrik Clausen
Department of Neuroscience, Neurosurgery, Uppsala University Hospital, Uppsala, Sweden
21 shared publications Lars Hillered
Uppsala University
18 shared publicationsPer Enblad
Department of Neuroscience, Neurosurgery, Uppsala University , Uppsala, Sweden
16 shared publications- Lars Hillered
Department of Neuroscience, section of Neurosurgery, Uppsala University, Uppsala, Sweden
14 shared publications Parmenion P. Tsitsopoulos
12 shared publications- Anders Hånell
Department of Medical Sciences, Section of Neurosurgery, Uppsala University, Uppsala, Sweden
11 shared publications
Latest Publications
- Open Access
- 10 August 2026
- Published by Elsevier in Brain and Spine
A paradigm shift in traumatic brain injury: what does the CBI-M classification offer?
- 10 August 2026
- Published by Elsevier in Brain and Spine
Open AccessA paradigm shift in traumatic brain injury: what does the CBI-M classification offer?
- Open Access
- 14 July 2026
- Published by Elsevier in Brain and Spine
- Vol. 6, 106173
Different predictors of neurosurgical intervention and mortality in moderate traumatic brain injury: a nationwide cohort study
- 14 July 2026
- Published by Elsevier in Brain and Spine
- Vol. 6, 106173
Open AccessDifferent predictors of neurosurgical intervention and mortality in moderate traumatic brain injury: a nationwide cohort study
- Open Access
- 26 June 2026
- Published by Springer Nature in Inflammation
- Vol. 49 (1) , 156
A Dynamic and Complex Early Inflammatory Response in Blood and Cerebrospinal Fluid of Severe Traumatic Brain Injury Patients: A Dual Platform Analysis
Severe traumatic brain injury (TBI) is associated with high mortality and long-term disability. Inflammation is central to TBI pathophysiology, yet early dynamics of inflammatory mediators in blood and cerebrospinal fluid (CSF) remain incompletely understood, and commonly used assay platforms have rarely been directly compared. We aimed to characterize the inflammatory response in blood and CSF during the first week after severe TBI and to assess agreement between electrochemiluminescence (ECL) and proximity extension assay (PEA). In this prospective observational study, adults with severe TBI ( n = 21) were recruited. Plasma and CSF samples were collected at two time points: days 1–3 and days 4–8. Orthopedic patients with minor extremity fractures ( n = 11) served as controls. Inflammatory mediator levels were quantified using ECL (11 mediators) and PEA (45 mediators). Group differences, temporal changes, and inter-platform agreement were analyzed. In plasma, 13 mediators were increased and 3 decreased, while in CSF, 19 were increased and 3 decreased during the first week post-injury. Key mediators (IL-6, IL-8, IL-10) were consistently elevated in both compartments. When comparing analytic methods, ECL and PEA showed strong cross-platform correlations for IL-8 and IL-10 in both plasma and CSF, whereas IL-13 showed weak, non-significant correlation. However, limited interchangeability between platforms and platform-related differences across compartments and time points were also observed. Severe TBI is associated with marked, temporal and compartmentalized inflammatory response during first post-injury, particularly in CSF. Comparison of ECL and PEA showed limited interchangeability, underscoring the importance of platform awareness and interpretation in TBI biomarker studies. Clinical trial number: Not applicable.
- 26 June 2026
- Published by Springer Nature in Inflammation
- Vol. 49 (1) , 156
Open AccessA Dynamic and Complex Early Inflammatory Response in Blood and Cerebrospinal Fluid of Severe Traumatic Brain Injury Patients: A Dual Platform Analysis
Severe traumatic brain injury (TBI) is associated with high mortality and long-term disability. Inflammation is central to TBI pathophysiology, yet early dynamics of inflammatory mediators in blood and cerebrospinal fluid (CSF) remain incompletely understood, and commonly used assay platforms have rarely been directly compared. We aimed to characterize the inflammatory response in blood and CSF during the first week after severe TBI and to assess agreement between electrochemiluminescence (ECL) and proximity extension assay (PEA). In this prospective observational study, adults with severe TBI ( n = 21) were recruited. Plasma and CSF samples were collected at two time points: days 1–3 and days 4–8. Orthopedic patients with minor extremity fractures ( n = 11) served as controls. Inflammatory mediator levels were quantified using ECL (11 mediators) and PEA (45 mediators). Group differences, temporal changes, and inter-platform agreement were analyzed. In plasma, 13 mediators were increased and 3 decreased, while in CSF, 19 were increased and 3 decreased during the first week post-injury. Key mediators (IL-6, IL-8, IL-10) were consistently elevated in both compartments. When comparing analytic methods, ECL and PEA showed strong cross-platform correlations for IL-8 and IL-10 in both plasma and CSF, whereas IL-13 showed weak, non-significant correlation. However, limited interchangeability between platforms and platform-related differences across compartments and time points were also observed. Severe TBI is associated with marked, temporal and compartmentalized inflammatory response during first post-injury, particularly in CSF. Comparison of ECL and PEA showed limited interchangeability, underscoring the importance of platform awareness and interpretation in TBI biomarker studies. Clinical trial number: Not applicable.
- Open Access
- 17 April 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
Favourable outcome in a subset of ultra-severe traumatic brain injury patients - a single-centre retrospective study
- 17 April 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
Open AccessFavourable outcome in a subset of ultra-severe traumatic brain injury patients - a single-centre retrospective study
- Open Access
- 13 April 2026
- Published by Springer Nature in Critical Care
- Vol. 30 (1)
Consensus statement from the 2025 Delphi panel on cerebral microdialysis in critical care
Purpose: Secondary brain injury is a common cause of poor outcome after trauma, subarachnoid hemorrhage, and intracerebral hemorrhage, and optimizing treatment requires real-time insight into cerebral metabolism. Cerebral microdialysis (CMD) uniquely provides key related information, yet consensus on its use has not been updated since publication of the consensus statement from the 2014 International Microdialysis Forum. We aimed to assess expert consensus on the use of CMD in critical care and provide contemporary guidance to standardize practice and advance clinical implementation. Methods: We conducted a 3-round modified Delphi study with international experts in CMD and neurocritical care. Consensus was defined as ≥ 75% agreement among non-abstaining respondents, with a minimum of 30 non-abstaining respondents required per statement. Statements not reaching consensus were iteratively revised based on panelist feedback. Results: Forty of 67 invited experts (60%) from 9 countries participated. Sixty of 62 individual items achieved consensus (97%) across 9 domains: indications and patient selection, technical and procedural considerations, detecting deterioration and secondary injury, metabolic interpretation, treatment algorithms, glucose management, sampling frequency, core reporting items, and barriers to clinical implementation. Conclusion: This consensus statement provides updated, evidence-informed recommendations for the use of CMD in critical care. The panel reaffirmed many core recommendations from the 2014 consensus while making targeted advances: cautious extension of guidance to intracerebral hemorrhage, comprehensive reporting guidance addressing frequently omitted elements (19 items vs. 6 in 2014), and identification of 10 key barriers to routine clinical adoption.
- 13 April 2026
- Published by Springer Nature in Critical Care
- Vol. 30 (1)
Open AccessConsensus statement from the 2025 Delphi panel on cerebral microdialysis in critical care
Purpose: Secondary brain injury is a common cause of poor outcome after trauma, subarachnoid hemorrhage, and intracerebral hemorrhage, and optimizing treatment requires real-time insight into cerebral metabolism. Cerebral microdialysis (CMD) uniquely provides key related information, yet consensus on its use has not been updated since publication of the consensus statement from the 2014 International Microdialysis Forum. We aimed to assess expert consensus on the use of CMD in critical care and provide contemporary guidance to standardize practice and advance clinical implementation. Methods: We conducted a 3-round modified Delphi study with international experts in CMD and neurocritical care. Consensus was defined as ≥ 75% agreement among non-abstaining respondents, with a minimum of 30 non-abstaining respondents required per statement. Statements not reaching consensus were iteratively revised based on panelist feedback. Results: Forty of 67 invited experts (60%) from 9 countries participated. Sixty of 62 individual items achieved consensus (97%) across 9 domains: indications and patient selection, technical and procedural considerations, detecting deterioration and secondary injury, metabolic interpretation, treatment algorithms, glucose management, sampling frequency, core reporting items, and barriers to clinical implementation. Conclusion: This consensus statement provides updated, evidence-informed recommendations for the use of CMD in critical care. The panel reaffirmed many core recommendations from the 2014 consensus while making targeted advances: cautious extension of guidance to intracerebral hemorrhage, comprehensive reporting guidance addressing frequently omitted elements (19 items vs. 6 in 2014), and identification of 10 key barriers to routine clinical adoption.
- Open Access
- 5 April 2026
- Published by Elsevier in Experimental Neurology
- Vol. 402, 115761
Age- and sex-dependent differences in white matter pathology in the chronic phase of diffuse traumatic brain injury in the mouse
- 5 April 2026
- Published by Elsevier in Experimental Neurology
- Vol. 402, 115761
Open AccessAge- and sex-dependent differences in white matter pathology in the chronic phase of diffuse traumatic brain injury in the mouse
- Open Access
- 23 March 2026
- Published by Springer Nature in Neurocritical Care
- Vol. 45 (1) , 1-14
Evaluation of a Novel Automated Cerebral Ventricular Drainage System for Intracranial Pressure Monitoring and Cerebrospinal Fluid Drainage in Neurocritical Care Patients: A Prospective, Randomized Clinical Study
Background: Neurointensive care is moving toward more automated patient management. This study aimed to evaluate a novel external ventricular drainage (EVD) system, the VGuard® system, as a tool for intracranial pressure (ICP) monitoring and automating ventricular drainage of cerebrospinal fluid (CSF), focusing on its safety and potential to reduce complications associated with manual EVD management. Methods: This prospective, randomized clinical study was conducted in the Department of Neurosurgery at Skåne University Hospital, Lund, Sweden. Patients (aged > 18 years) with different acute brain pathologies requiring an EVD were enrolled and randomized (1:1) to receive the VGuard® system or a manual EVD. Both systems employed a ventricular probe for simultaneous intraventricular and intraparenchymal ICP monitoring. Measurement accuracy was determined by comparing the median of absolute difference in ICP, using the Mann–Whitney U test. To further investigate the accuracy of ICP measuring, a post hoc Spearman correlation test was applied. In addition, as part of a post hoc analysis, we evaluated patient outcomes. Results: A total of 30 patients were included in the study. The VGuard® system demonstrated significantly better accuracy in ICP measurements compared with the manual EVD; median absolute difference: 1.07 versus 2.88, p < 0.001; median Spearman correlation coefficients: 0.81 versus 0.48, p < 0.05. There were no statistically significant differences in patient outcomes [mortality, Glasgow Outcome Scale-Extended (GOSE), modified Rankin Scale (mRS), median time with the EVD, and length of intensive care unit (ICU) stay], or adverse events (AE). No serious adverse events were noted. Conclusions: This is the first study to evaluate the VGuard® system, showing results of increased accuracy in measured ICP compared with the manual EVD. The VGuard® system offers an automated EVD solution, representing a step toward increased neurointensive care automation.
- 23 March 2026
- Published by Springer Nature in Neurocritical Care
- Vol. 45 (1) , 1-14
Open AccessEvaluation of a Novel Automated Cerebral Ventricular Drainage System for Intracranial Pressure Monitoring and Cerebrospinal Fluid Drainage in Neurocritical Care Patients: A Prospective, Randomized Clinical Study
Background: Neurointensive care is moving toward more automated patient management. This study aimed to evaluate a novel external ventricular drainage (EVD) system, the VGuard® system, as a tool for intracranial pressure (ICP) monitoring and automating ventricular drainage of cerebrospinal fluid (CSF), focusing on its safety and potential to reduce complications associated with manual EVD management. Methods: This prospective, randomized clinical study was conducted in the Department of Neurosurgery at Skåne University Hospital, Lund, Sweden. Patients (aged > 18 years) with different acute brain pathologies requiring an EVD were enrolled and randomized (1:1) to receive the VGuard® system or a manual EVD. Both systems employed a ventricular probe for simultaneous intraventricular and intraparenchymal ICP monitoring. Measurement accuracy was determined by comparing the median of absolute difference in ICP, using the Mann–Whitney U test. To further investigate the accuracy of ICP measuring, a post hoc Spearman correlation test was applied. In addition, as part of a post hoc analysis, we evaluated patient outcomes. Results: A total of 30 patients were included in the study. The VGuard® system demonstrated significantly better accuracy in ICP measurements compared with the manual EVD; median absolute difference: 1.07 versus 2.88, p < 0.001; median Spearman correlation coefficients: 0.81 versus 0.48, p < 0.05. There were no statistically significant differences in patient outcomes [mortality, Glasgow Outcome Scale-Extended (GOSE), modified Rankin Scale (mRS), median time with the EVD, and length of intensive care unit (ICU) stay], or adverse events (AE). No serious adverse events were noted. Conclusions: This is the first study to evaluate the VGuard® system, showing results of increased accuracy in measured ICP compared with the manual EVD. The VGuard® system offers an automated EVD solution, representing a step toward increased neurointensive care automation.
- Open Access
- 20 January 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
Increased intracranial pressure in severe traumatic axonal injury patients - A retrospective single-center study
- 20 January 2026
- Published by Elsevier in Brain and Spine
- Vol. 6
Open AccessIncreased intracranial pressure in severe traumatic axonal injury patients - A retrospective single-center study
- Open Access
- 19 December 2025
- Published by Elsevier in World Neurosurgery
- Vol. 205, 124748
Anterior Cord Herniation—Surgical Video
- 19 December 2025
- Published by Elsevier in World Neurosurgery
- Vol. 205, 124748
Open AccessAnterior Cord Herniation—Surgical Video